Amends 20 & 20 to Licenses NPF-37 & NPF-66,respectively, Approving Change to Tech Spec Action Statement Re UHS
ML20151M726
Person / Time
Site: Byron  
Issue date: 07/21/1988
From: Holahan G
Office of Nuclear Reactor Regulation
To:
Commonwealth Edison Co
Shared Package
ML20151M730 List:
References
NPF-37-A-020, NPF-66-A-020 NUDOCS 8808050311
Download: ML20151M726 (6)


Text

-

guarug'o UNITED STATES g

NUCLEAR REGULATORY COMMISSION e

o 3

p WASHINGTON, D. C. 20555

%,.....,o COMMONWEALTH EDIS0N COMPANY DOCKET NO. 50-454 BYRON STATION, UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 20 License No. NPF-37 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Comonwealth Edison Company (the licensee) dated June 22, 1988, supplemented July 14, 1988 and July 18, 1988, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifi-cations as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-37 is hereby amended to read as follows:

l kk O&OCK 311 080721 05000454 P

PNu

. (2) Technical Specifications The Technical Specifications contained in Appendix A as revised through Amendment No. 20 and the Environment Protection Plan contained in Appendix B, both of which are attached hereto, are hereby incorpo-rated into this license. The licensee shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

l 3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION b}W n

Gary Holahan, Acting Director Division of Reactor Projects - III, IV, V and Special Projects

Attachment:

Changes to the Technical Specifications Date of Issuance:

July 21, 1988

)

m..

kQCfog e

cf o,*

UNITED STATES NUCLEAR REGULATORY COMMISSION n

(

WASHINGTON, D. C. 20555 COMMONWEALTH EDIS0N COMPANY DOCKET N0. 50-455 BYRON STATION, UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 20 License No. NPF-66 1.

The Nuclear Regulatory Comission (the Commission) has found that:

A.

The application for amendment by Comonwealth Edison Company (the licensee) dated June 22, 1988, supplemented July la, 1988 and July 18, 1988, complies with the standards and requirements of: the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter 1; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuaace of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifi-cations as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-66 is hereby amended to read as follows:

(2) Technical Specifications The Technical Specifications contained in Appendix A (NUREG-1113), as revised through Amendment No. 20 and revised by Attachment 2 to NPF-60, and the Environmental Protection Plan contained in Appendix B, both of which were attached to License No. NPF-37, dated February 14, 1985, are hereby incorporated into this license. Attachment 2 con-tains a revision to Appendix A which is hereby incorporated into this license. The licensee shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

><l V

Gary aban, Acting Director Division of Reactor Projects - III, IV, Y and Special Projects

Attachment:

Changes to the Technical Specifications Date of Issuance: July 21, 1988

1 ATTACHMENT TO LICENSE AMENDMENT NOS. 20 AND 20 FACILITY OPERATING LICENSE NOS. NPF-37 AND NPF-66 DOCKET NOS. 50-454 AND 50-455 Revise Appendix A as follows:

Remove Pages Insert Pager.,

3/4 7-14 3/4 7-14

,---,----,,a,,

e

..n n-,,,

.-c,.

.-.----,,..e

-r

,a

.c-

PLANT SYSTEMS LIMITING CONDITION FOR OPERATION (Continued) l

~

ACTION (Continued) c.

With one essential service water makeup pump inoperable, restore the essential service water makeup pump to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDSY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

d.

With the essential service water pump discharge water temperature not meeting the above requirement, be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

With the minimum Rock River water level not meeting the above require-e.

ment, notify the NRC within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> in accordance with the procedure of 10 CFR 50.72 of actions or contingencies to ensure an adequate supply of cooling water to the Byron Station for a minimum of 30 days, verify the Rock River flow within I hour, and:

(1) If Rock River flow is less than 700 cubic feet per second (cfs) be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and COLD SHUT-DOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />, or (2) If Rock River flow is equal to or greater than 700 cfs continue verification procedure every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> or until Rock River water level exceeds 670.6 feet MSL (the provisions of Specification 3.0.4 are not applicable), or (3) If Rock River level is equal to or less than 664.7 feet MSL be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> f.

With one deep well inoperable and:

(1) The Rock River water level predicted, through National Weather Service flood forecasts, to exceed 702 feet MSL, or (2) The Rock River water level at or below 670.6 feet MSL, or (3) A tornado watch issued by the NWS that includes the area for the Byron Station.

l Notify the NRC within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> in accordance with the procedure of 10 CFR 50.72 of actions or contingencies to ensure an adequate supply of cooling water to the Byron Station for a minimum of 30 days and restore both wells to OPERABLE status before the Rock River water I

level exceeds 702 feet MSL or the minimum Rock River level or flow falls below 664.7 feet MSL or 700 cfs, respectively, or within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, whichever occurs first, or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREMENTS 4.7.5 The UHS shall be determined OPERABLE at 1aast once per:

a.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> by verifying the water level in each UHS cooling tower basin to be greater than or equal to 873.75 feet MSL (50%),

BYRON - UNITS 1 & 2 3/4 7-14 AMENDMENT NO. 20 s