- _ - - _ _ _. -
8 4
1 1
'Af Telephone (412) 333-6000 x4 Shippingport. PA 11077-0004 July 26, 1988 U. S. Nuclear Regulatory Commission Attn:
Document Control Desk Washington, DC 20555
Reference:
Beaver Valley Power Station, Unit No. 1 and No. 2 BV-1 Docket No. 50-334, License No. DPR-66 BV-2 Docket No. 50-412, License No. NPF-73 NRC Compliance Bulletin 87-02, Supplements 1 & 2 Gentlemen:
In response to supplements 1
and 2
of NRC Bulletin 87-02 "Fastener Testing to Determine Conformance with Applicable Material Specifications", enclosed is the information requested.
If there are any questions concerning this response, please contact my office.
s very truly yours, J. D.
Sieber Vice President Nuclear Group Enclosure cc:
Mr. J. E. Beall, Sr. Resident Inspector Mr. W. T. Russell, NRC Region I Administrator Mr. P. Tam, Project Manager Director, Safety Evaluation & Control (VEPCO)
ADOb Ob334 DR Q
1 Q
COMMONWEALTH OF PENNSYLVANIA)
)
SS:
COUNTY OF BEAVER
)
On this
_ M '[I,
day of N4/"
, 1988, Mbh4///,Y M t/
No#taryhublicinandforsaid before me, a
Commonwealth and County, personally appeared'J. D. Sieber, who being duly
- sworn, deposed, and said that (1) he is Vice President of Duquesne
- Light, (2) he is duly authorized to execute and file the foregoing submittal on behalf of said Company, and (3) the statements set forth in the submittal are true and correct to the best of his knowledge, information and belief.
1//f J
}.
IbbC%
/
=== an.
MPFitW 8090. MAYER CDUNff M MNX1 EXPIM3 OCT. 23,1900
- w. %,d
- f*v
- t % d eventse i
DUQUESNE LIGHT COMPANY s
Nuclear Group i-Baavor Valley Power Station, Unit 1 and 2 Response To NRC Bulletin 87-02, supplements 1 & 2 l
ACTION REQUIRED Provide the following information concerning the procurement of fasteners:
1.
A list of the suppliers and manufacturers from which safety-related ferrous fasteners 1/4 inch in diameter or greater may have been purchased, within the past 10 years, including addresses.
For those fasteners purchased from fastener suppliers and/or original equipment manufacturers, any available information that identifies the manufacturer or sub-tier supplier of the fasteners also should be provided.
Approved Vendor List or Qualified Supplier Lists are the intended sources for this information.
Addressees are not required to search purchase order files, contact subcontractors to obtain the information, or submit data on fasteners supplied as part of an original component.
2.
For non-safety-related fasteners the same information as requested in the first two sentences of item 1, above, except that a) the time of interest is for fasteners procured in the last 5 years, and b) the search of available records in this case should include purchase orders unless the licensee utilizes approved vendor lists or qualified supplier lists in procuring nonsafety-related fasteners.
This information collection is understood to be on a best-effort basis.
Further, addressees are not required to contact subcontractors to obtain the information or to submit data on fasteners supplied as part of an original component.
RESPONSE
Enclosed tre listings of suppliers and manufacturers who have supplied fasteners for use at Beaver Valley Units 1 and 2.
For items l
purchased directly by Duquesne Light Co.,
a computer sort was performed of the existing data base for purchase orders.
In
- addition, we have included lists of vendors who have supplied site contractors.
Attachment 1
includes suppliers for safety related systems and includes suppliers of non-safety related material.
I
s Page No.
1 07/22/88 ATTACIIMENT 1 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATICN VENDORS WHO HAVE SUPPLIED SAFETY RELATED FASTENERS (CAT. 1)
ALLEGHENY PIPE & GUPPLY CO.
P. O. BOX 9340 PITTSBURGH PA 15225 ALLEGHENY PUMP & EQUIPMENT 353 PITTSBURGH ROAD BUTLER PA 16001 AMOT CONTROLS CORP.
P.O.
BOX 1312 RICHMOND CA 94802 At1CHOR DARLING VALVE CO.
P.
O.
BOX 3428 WILLIAMSF.'/P PA 17701 ASEA BROWN BOVERI
% VERHILL ASSOC.
3550 LAKETON RD.
PITTSBURGH PA 15235 ATLAS It1DUSTRIAL MANUFACTURIt1G CO.
80 SOMERSET PLACE CLIFTON NJ 07012 BAKER PROCESS EQUIPMEt1T CO.,
INC.
P.
O.
BOX 898 308 MOOT 1 CLIllTON ROAD CORA0 POLIS PA 15108 BBC-BROWN BOVERI, (USE#0726)
ELECTRIC SYSTEMS GROUP (I-T-E) 1081 GREENTREE ROAD PITTSBURGH PA 15220 BERGEN-PATTERSOt1 PIPE SUPPORT 74 COMMERCE WAY WOBUR11 MA 01888 l
BINGHAM INTERt1ATIONAL EASTERN SERVICE CENTER 621 HERON DRIVE, P.
O.
BOX 487 BRIDGEPORT 11J 08014 BINGHAM IllTERNATIONAL, INC.
22 MULLER PLACE LITTLE FALLS NJ 07424
s Pege No.
2 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED SAFETY RELATED FASTENERS (CAT. 1)
BORG WARNER P.
O.
BOX 463 BRIDGEPORT NJ 08014 BW/IP INTERNATIONAL, INC. PUMP DIV.
740 EAST LANCASTER AVE.
SUITE 155 EXTON PA 19341 BW/IP, FLUID CONTROLS DIV.
ATT:
SHARON HODGE 7500 TYRONE AVE.
VAN NUYS CA 91409 BYRON JACKSON PUMP (USE 1008P)
BORG-WARNER CORPORATION 1105 SCHROCK ROAD, SUITE 231 COLUMBUS OH 43229 CAPITOL PIPE & STEEL PRODUCTS CO.
1029 CONSH0HOCKEN RD.
CONSH0HOCKEN PA 19428 CARRIER BUILDING SERVICES 135 SOUTHPOINTE DRIVE BRIDGEVILLE PA 15017 CONAX BUFFALO CORP.
% M.S.
JACOBS 810 NOBELSTOWN RD.
PITTSBURGH PA 15205 CRANE-ALOYCO, INC.
12 EAST DEVONWOOD DRIVE ROME 0VILLE IL 60441 l
CUNNINGHAM COMPANY. INC.
269 MEADOWLANDS BOULEVARD WASHINGTON PA 15301 l
CYBEREX, INC.
7171 INDUSTRIAL BLVD.
MENTOR OH 44060 DECKER REICHERT 3611 HENDRICKS RD.
P.O.
BOX C YOUNGSTOWN OH 44515
Page No.
3 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED SAFETY RELATED FASTENERS (CAT. 1)
DRESSER INDUSTRIES, INC.
AVON OPERATIONS, MASONEILAN DIV.
P.O. BOX 85765 DALLAS TX 75285 DRESSER RAND COMPANY STEAM TURBINE MOTOR & GENERATOR DIV 37 COATS STREET WELLSVILLE NY 14895 ELECTRO-MOTIVE P. O. BOX 430 LA GRANGE IL 60525 EQUIPMENT & CONTROLS INC.
MAYVIEW RD. AT PARK DR.
LAWRENCE PA 15055 EXCIDE CORP.
2635 HAMILTON AVE.
CLEVELAND OH 44114 FAIRBANKS MORSE ENGINE DIV.
COLT INDUSTRIES, INC.
701 LAWTON AVE.
BELOIT WI 53511 FARWELL & HENDRICKS INC.
PARK 50 TECHCENTER 1000 FORD CIRCLE SUITE G MILFORD OH 45150 FISHER CONTROLS INTERNATIONAL, INC.
C/0 EQUIPMENT CONTROLS, INC.
P. O. BOX 12895 PITTSBURGH PA 15211 FRICK & LINDSAY COMPANY 3499 GRAND AVENUE PITTSBURGH PA 15225 GIPSON BEARING & SUPPLY COMPANY 980 FOREST AVENUE WEST HOMESTEAD PA 15120 GOULDS PUMPS, INC.
TWO PARKWAY CENTER SUITE 117 PITTSBURGH PA 15220
Page lio.
4 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER JTATION VENDORS WHO HAVE SUPPLIED SAFETY RELATED FASTENERS (CAT. 1)
GRAYBAR ELECTRIC COMPANY, INC.
900 RIDGE AVENUE PITTSBURGH PA 15212 GRINNELL CORPORATION 1321 RIDGE AVENUE PITTSBURGH PA 15233 HARMON/KEYST0t1E CORP.
P.O.
BOX 791 BUTLER PA 16001 HOKE, INC.
1 TENAKILL PARK CRESSKILL NJ 07626 INGERSOL-RAND CO.
% PARTS OhuER SERVICE P.O.
BOX 3565 SCRAllTON PA 18505 INTERNATIONAL POWER MACHINES CORP P.O.
BOX 724 MESQUITE TX 75149 ITT BARTON C/0 M. S. JACOBS & ASSOCIATES, INC.
810 NOBLESTOWN ROAD PITTSBURGH PA 15205 JOHN CRANE-HOUDAILLE COMPANY 111 INDUSTRY DRIVE RIDC WEST PITTSBURGH PA 15275 JOSEPH OAT COMPANY 2500 BROADWAY DRAWER 10 CAMDEN NJ 01804 KER0 TEST MANUFACTURING COMPANY DEPARTMENT L236P 2525 LIBERTY AVENUE PITTSBURGH PA 15264 KOP-FLEX, INC.
POWER TRANSMISSION PRODUCTS P.O.
BOX 1384 BOSTON MA 02205
Page No.
6 o
07/22/88 s
DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED SAFETY RELATED FASTENERS (CAT. 1)
KRANCO, INC.
ATTN:
SAM MORGAN 1365 CHARDON ROAD CLEVELAND OH 44117 LEEDS & NORTHRUP COMPANY SUITE 600, MANOR OAK #1 1910 COCHRAN ROAD PITTSBURGH PA 15220 LENZ COMPANY P. O.
BOX 1044 DAYTON OH 45401 LIMITORQUE CORPORATION WEXFORD PROFESSIONAL BUILDING SUITE 109, 11876 PERRY HIGHWAY WEXFORD PA 15090 LOUIS ALLIS CO.
300 CEDAD BLVD. SUITE 202 PITTSBURGH PA 15228 MASONEILAN DIVISION, DRESSER INDUSTRIES,C/O DAVIS CONTROLS CORP.
108 PARKWAY VIEW DRIVE PITTSBURGH PA 15205 MASONEILAN-N. AMERICAN OPERATIONS DRESSER VALVES & CONTROLS DIV.
85 BODWELL ST.
AVON MA 02322 MASONEILAN-NORTH AMERICAN OPERATION DRESSER VALVE & CONTROLS DIV.
85 BODWELL ST.
AVO!1 MA 02322 MCCULLOUGH ELECTRIC COMPANY 419 FORT PITT BOULEVARD PITTSBURGH PA 15219 MCJUNKIN CORPORATION BUNCHER DIST.
LEETSDALE PA 15066 MOSEBACH ELECTRIC & SUPPLY COMPANY 1115 ARLINGTON AVENUE PITTSBURGH PA 15203
o Page No.
6 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED SAFETY RELATED FASTENERS (CAT. 1)
MOSLER, INC.
720 TRUMBULL DR.
PITTSBURGH PA 15204 NUTTALL GEAR CORP.
2221 NIAGARA FALLS BLVD.
P.O.
BOX 1032 NIAGARA FALLS NY 14302 PACIFIC PUMP DIV.
DRESSER INDUSTRIES INC.
5715 BICKETT ST.
HUNTINGTON PARK CA 90255 PACIFIC PUMPS DIVISION DRESSER INDUSTRIES 6250 HALLE DRIVE CLEVELAND OH 44125 PACIFIC SCIENTIFIC COMPANY KIN-TECH DIVISION 1346 S. STATE COLLEGE BLVD.
ANAHEIM CA 92803 PACIFIC VALVES, INC.
3201 WALNUT STREET LONG BEACH CA 90807 PAUL-MUNROE ENERTECH 2950 BIRCH ST.
BREA CA 92621 PBI INDUSTRIES, INC.
P.O. BOX 229 ROCHESTER PA 15074 PITTSBURGH DESIGN SERVICE HAMMOND & GREGG STS.
P.O. BOX 469 CARNEGIE PA 15106 PITTSBURGH VALVE & FITTING COMPANY 49 MEADE AVENUE PITTSBURGH PA 15202 PLOTKIN BROTHERS, INC.
1050 OHIO AVE GLASSPORT PA 15045
Pega No.
7 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED SAFETY RELATED FASTENERS (CAT. 1)
POWER CONVERSION PRODUCTS INC.
42 EAST ST.
P.O. BOX 380 CRYSTAL LAKE IL 60014 ROCKWELL INTERNATIONAL CORP.
P. O. BOX 1981 RALEIGH NC 27602 SEALING SPECIALISTS & SERVICE CO.
969 WILLIAM FLYNN HIGHWAY ROUT 8 GLENSilAW PA 15116 SEIMANS-ALLIS, INC.
SUITE 101 BOYCE PLAZA 1035 BOYCE ROAD PITTSBURGH PA 15241 STANDARD AIR & LITE CORP.
33RD ST. & LIBERTY AVE.
PITTSBURGH PA 15201 STOW MANUFACTURING CO.
P.O.
BOX 490 BINGHAMTON NY 13902 STOW MANUFACTURING COMPANY P. O. BOX 490 BINGHAMTON NY 13902 TARGET ROCK CORPORATION POWER PRODUCTS DEPARTMENT P. O.
BOX V EAST FARMINGDALE NY 11735 TECH SYN CORP.
225 EAST PROSPECT AVE.
MT. PROSPECT IL 60056 TELEMECANIQUE 2002 BETHEL RD.
WESTMINSTER MD 21157 THE CYPHER COMPANY 4790 OLD FRANKSTOWN ROAD MONROEVILLE PA 15146
o.
Page No.
8 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED SAFETY RELATED FASTENERS (CAT. 1) i THE FAULK CORP.
300 MT. LEBANON BLVD.
PITTSBURGH PA 15234 THE GAGE COMPANY P. O.
BOX 1168 PITTSBURGH PA 15230 THERMON MANUFACTURING
% MULLER HARPER, INC.
2406 NICHOLSON ROAD SEWICKLEY PA 15143 TRACOR WESTRONICS C/0 GILSON ENEGINEERING SALES, INC.
978 PERRY HIGHWAY PITTSBbRGH PA 15237 TRANSAMERICA DELAVAL INC.
250 MT. LEBANON BLVD.
PITTSBURGH PA 15234 TRANSMISSION EQUIPMENT CO.
1700 JANE ST.
PITTSBURGH PA 15203 VALQUIP CORP.
2275 SWALLON HILL RD.
BLDG 100 PITTSBURGH PA 15220 WALLACE & TIERNAN PENNWALT CORPORATION BOX 178 NEWARK NJ 07101 WEINMAN PUMP & SUPPLY COMPANY 110 DELTA DRIVE RIDC INDUSTRIAL PARK PITTSBURGH PA 15238 WESTBURNE SUPPLY, INC.
5800 OAKBROOK PARKWAY NORCROSS GA 30093 WESTINGHOUSE ELECTRIC CORPORATION 1
P. O. BOX 1017 PITTSBURGH PA 15230
Page No.
9 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED SAFETY RELATED FASTENERS (CAT. 1)
WESTINGHOUSE ELECTRIC SUPPLY CO.
209 W. GEN. ROBINSON STREET PITTSBURGH PA 15212 XOMOX CORPORATION TUFLINE DIVISION 4444 COOPER ROAD CINCINNATI OH 45242
'ATTACHMEPff 1-Duquasne Light Company 1
-Beaver Valley Power Station Safety-related Fastener Supplies PURCHASED BY SCHNEIDER-NAME & ADDRESS TYPE OF FASTENER MCJUNKIN CORP.
A194 GR 7 AVE. B. BUNCHER IND. DIST.
A194 GR 2H LEETSDALE, PA 15056 A193 GR B7 PEPCO ASME SA-193 GR B8 151 HELEN STREET ASHE SA-194 GR Bd S. PLAINFIELD, NJ 07080 POVER PIPING CO.
ALL THRD. ROD & H NUTS 829 BEAVER AVE.
A193 GR B8 PITTSBURGH, PA 15230 A194 GR B ALL THRD R0D ASTM A307-78 GRAA GENERAL MFG. CO.
ASTM A193-81 GR B7 2986 INDUSTRIAL BLVD.
BETHEL PARK, PA 15102 IRVIN AUTOMOTIVE ASTM A540 715 CLEVELAND ST.
4340 GR B23 GREENBURG, PA 15601 HCMASTER-CARR FLANGE NUTS P.O. BOX 440 BOLTS NEV BRUNSVICK, NJ 08903 PITTSBURGH VALVE & FITTING SS-602-1 P.O. B0X 4155 BELLEVUE, PA 15302 i
PLOTKIN BROS. SUPPLY, INC.
ASTM A307-80 GR B 1050 OHIO AVE.
ASTM A307-80 GALV.
GLASSPORT, PA 15045 ASTM A307-80 GR B GALV.
i R.E.L.
A193-78 GR B7 CEDAR & SPRING STREET A194-78 GR 2H NEV ROCHELLE, NY 10802 ASME SA194 GR 8 ASME SA-193 GR BQ SCHNEIDER SHEET METAL ASTM A307
[
1840 PENNSYLVANIA & PREBLE AVE.
PITTSBURGH, PA 15233 VILLIAMS & CO.
18-8 SS 901 PENNSYLVANIA AVE.
PITTSBURGH, PA 15233 AUTOMATIC SPRINKLER CORP.
NUTS & BOLTS 930 THIRD STREET OAKMOUNT, PA 15139
.~
ATTACHMENT 1 Duqu;an: Light Comprny Beaver Valley Pover Station Safety-related Fastener Supplies PURCHASED BY SCHNEIDER NAME & ADDRESS TYPE OF FASTENER BADEN STEEL BAR & BOLT ALL THRD. R0D ASTM A193 GR D7 ROUTE 3 ALL THRD. R0D ASTM A307 SEVICKLEY, PA 15143 A194 2H ASTM A193 B7 ASTM A194 GR 2H ASTM A194 GR 2H ASTM A325 Type I ASTM A193 77A B7 ASTM A307 GR A 18-8 SS ASTM A193 A194 GR B ALL THRD. R0D A193-78 GRB7 ASTM A193-81 GR B7 ASTM A194-81 GR H2 ASTM A193-78 GR B7 ASTM A194-78 GR 2H ALL THRD R00 ASTM A307-83A ASTM A194-82A GR 2H ALL THRD R0D ASTM A193-82 GR B7 ASTM A325-81 ASTM A963-83A ASTM A307 GR A ASTM SA-193-83 GR B7 D-BOLT
'MPANY A307 1005 Ec..HTH AVE.
ASTM A194 2H GLENSH6%, PA ASTM A193 B7 ASTM A193 B8 ASTM A194 GR8 ALL THRD R0D A193 GR8 ASTM A325 TYPE I ASTM 449 ASTM A307B ASTM A307 GRB ASTM A563 GR A ASTM A307 GR A ASTM A563 GR 8 ASTM A325 ASTM A193-79 GR B7 ASTM A194-79 GR 2H ASTM A193-62 GR B7 ASTM A194-82A GR 2H ASTM A193 GR B7 ASTM A194-82 GR 2H ASTM A193-82 GR B7 ASTM A193-81 GR B7 ASTM A194-81 GR 2H -
ATTACHMENT 1 Duqu:sne Light Company Beaver Valley Power Station Safety-related Fastener Supplies PURCHASED BY SCHNEIDER NAME & ADDRESS TYPE OF FASTENER DELL FASTENER ALL THRD R0D A193-78 GR B7 91 SOUTHPOINTE DR.
ASTM A194-78 GR 2H BRIDGEVILLE, PA 15017 ALL THRD ROD ASTM A193-78 GRB7 ASTM A307-78 GRB ASTM A563-80B ASTM A574 ASTM A36-81A ASTM A193-81A ASTM A193-82 GR B7 ASTM A194-81 GR 2H ASTM A449-83A ASTM A563-83A GR B ASTM A374-83 ASTM A36-81A ASTM A449-83 ASTM A193-81 GR B7 FASTENER HOUSE A193 GR B7 405 PARKVIEV DR.
A194 GR 2H PITTSBURGH, PA 15205 316 SS CLASS 2 ASTM A193 GR B8H A194 GR B8M A194 18-8 S/S 18-8 A193-GR B6 A194 GR B6 GR 5 A325 310 SS A307 GR B A563 GR B A325 TYPE 1 ASTM A276 TP 410SS ASME SA193 83 B7 SA194-83 GR 2H ASTM A193-81A GR B7 ASTM A194-81 GR 2H ASTM A193-78 ASTM A194-78 GR B8 s
ATTACHMENT 1 y
Duqu:sn2 Light Company l
Beaver Valley Pover Station Safety-related Fastener Supplies PURCHASED BY SCHNEIDER NAME & ADDRESS TYPE OF FASTENER FASTENERS UNLIMITED ASTM A307-80 GR A 117 MONT0UR V.
IND. PARK ASTM A194-80 GR 2H CORA0 POLIS, PA 15108 ASTM A194-82A GR 2H ASTM A193-82 GR B7 ALL THRD ROD A36 81A ASTM SA193-83 ASTM A194 GR 2H ASTM A325-81 ASTM A193 B7 ASTM A194 GR 7B ASTM A325-81 ALL THRD. R0D A193-82 GR B7 ASTM A325 TYPE 1 A194 GR 2H A307 GR A V/A 563 ASTM A363 ASTM A194-84A GR 2H rm.
ATTACHMENT 1 y
Duquasne Light'Coapany Beaver Valley Power Station Safety-related Fastener Supplies PURCHASED BY SARGENT ELECTRIC NAME & ADDRESS TYPE OF FASTENER THE FASTENER HOUSE SIL-ZINC PLTD.
4
~405 PARKVAY VIEV DRIVE A-307 PITTSBURGH, PA 15205-STEEL SIL. BRONZE A193 GR B7 A194 GR 2H
-300 SERIES STAINLESS A325 A325 TYPE I A563 SAE J429 GR 2 A36 A193 GR B8 A194 GR 8 SAE J-429-ZINC PLTD.
18/8 STAINLESS STEEL SAE GR 5 SERVICE SUPPLY CO. INC SIL. BRONZE 11 SHINGISS STREET SIL.-ZINC PLTD.
MCKEES ROCKS, PA 15136 A307 A194 GR 2R A325 TYPE I 18/8 STAINLESS A193 GR B7 A325 FASTENERS UNLIMITED A307 117 MONT0UR EST IND. BLVD.
A193 GR B7 CORA0 POLIS, PA 15108 SIL.-ZINC PLTD.
A194 GR 2H A449 GR 5 SIL. BRONZE-DELL FASTENER CORP.
A325 91 SOUTH POINTE DRIVE A194 GR 2H BRIDGEVILLE, PA 15017 A193 GR B7 STL.-ZINC PLTD.
A307 A325 TYPE I SIL. BRONZE 300 SERIES STAINLESS A307 GR A VILLIAMS & COMPANY SIL. BRONZE 901 PENNA. AVE.
PITTSBURGH, PA 15233 ATTACHMEfff 1 '
3
.Duquesna Light Company Beaver Valley Power Station
-Safe'.y-related Fastener Supplies PURCHASED BY SARGEffr ELECTRIC NAME & ADDRESS TYPE OF FASTENER UNISTRUT-PITTSBURGH A307 711 PARKVAY VIEV DRIVE-STEEL PITTSBURGH, PA 15205 SAE J429 GR 2 BARBARA NUT & BOLT H.H. BOLTS & FLATVASHERS -
208 PARKVAY VIEV DRIVE CAD. PLTD.
PITTSBURGH, PA 15205 MILLER'S HARDVARE & SUPPLY LOCKVASHERS 739 MIDLAND AVE.
H.H BOLTS HIDLAND, PA 15059 OUALITY PRODUCTS, INC.
A307 GR. A 803 CAMP HORNE ROAD PITTSBURGH, PA 15237 D-BOLT COMPANY OF PA A325 TYPE I 1005 EIGHTH AVE.
A194 GR 2H GLENSHAV. PA 15116 STL.-ZINC PLTD.
BADEN STEELBAR & BOLT A194 GR 2H BIG SEVICKLEY ROAD A325 TYPE I SEVICKLEY, PA 15143 STL.-ZINC PLTD.
A307 SOUTHERN BOLT & FASTENER A325 TYPE I 301 MONTGOMERY SHREVEPORT, LA 71107 MID-STATE BOLT & NUT SAE J429-ZINC PLTD.
2350 ELDO ROAD STL.-ZINC PLTD.
MONROEVILLE, PA 15146 AMBRIDGE ELECTRIC COMPANY A307 1320 MERCHANT STREET AMBRIDGE, PA 15003 DUQUESNE LIGHT COMPANY A325 TYPE I C/0 STONE & VEBSTER ENGR. AGENT A325 P.O. BOX 186 A194 GR 2H SHIPPINGPORT, PA 15077 A193 GR B7 SIL. BRONZE SIL.-ZINC PLTD.
A307 ATTACHMENT 1 g
Duqu sn2 Light Company Beaver Valley Power Station Safety-related Fastener Supplies PURCilASED BY DICK CORPORATION NANE & ADDRESS TYPE OF FASTENER BARBARA BOLT & NUT CO.
BOLTS 208 PARKVAY DRIVE NUTS ROBINSON T0VNSHIP, PA H&S MACHINE & SUPPLY CO.,
INC.
NUTS A-325 FLAUGHERTY RUN RD.
CORA0 POLIS PA D-BOLT COMPANY OF PA BOLT GLENSHAV, PA 37600 NUT BADEN STEELBAR & BOLT BOLTS, NUTS BIG SEVICKLEY CREED RD.
3/4 X l'-7" ALTHD.
SEVICKLEY, PA A-307 ALTHD. NUTS 5/8 X l'-2" GALV. BOLTS 3/8 GALV. NUTS A194 1/2 X 3/4 A325
_7_
ATTACilMENT 1 3
Duqu:sn2 Light Company Beaver Valley Power Station Safety-related Fastener Supplies PURCilASED BY STONE & VEBSTER NAME & ADDRESS TYPE OF FASTENER CTS INC.
VASHERS & NUTS 3616 LIBERTY AVE.
SILICONE BRONZE PITTSBURGH, PA VILLIAMS & COMPANY BOLTS, NUTS, VASHERS 901 PENNSYLVANIA AVE.
SILICONE BRONZE PITTSBURGH, PA 15233 B.F. GOODRICH CO.
- S50-385 RIVNUTS C/0 RAY SIMON & ASSOC.
- S50-265 RIVNUTS 117 MAIN ST.
P.O. BOX V IRVIN, PA 15642 GEORGE L. VILSON & COMPANY LAGS 220 E. GENERAL ROBINSON ST.
INSERTS EC-2V PITTSBURGH, PA 15212 INSERTS EC-2FV INSERTS INSERTS EC-4F INSERTS LTL4F INSERTS LCB-1 STUDS LSLS ANCHORS SCA BOLTS SAE B INSERTS LTL-2F ANCHORS SCA BOLTS SAE B INSERTS LTL-2F INSERTS EC-2V INSERTS EC-2FV SLEEVES INSERTS LF SYM0NS CORPORATION INSERT 3 TL4F 7603 OLL ROCKSLIDE ROAD INSERTS LEL-SH CLEVELAND, OHIO 44131 STUDS LSLS LAGS LLAG INSERTS LTL LAGS INSETS LTL48 BOLTS BERGEN-PATERSON PIPE SUPPORT CORP D-BOLTS NO. 222 74 COMMERCE VAY EYENUTS NO. 274 V0 BURN, MA 01801
~'-
- ~
ATTACHMEfff - 1 Duquesna Light Company.
. Beaver Valley Pover Station Safety-related Fastener Supplies PURCHASED BY STONE & VEBSTER TYPE OF FASTENER NAME,A ADDRESS PBI INDUSTRIES ASTM A-193 GR B7 P.O. B0X 229 ASTM A-194 GR 2H ROCHESTER, PA 15074 FLAT HEAD CAP SCREVS ASTM A-193 GR B8 ASTM A-325 BOLTS ASTM A-325 NUTS ASTM A-194 GR 2H ASTM A-194 GR 8 ASTM A-36 ANCEOR BOLTS ASTM A-194 NUTS ITT GRINNELL FIG. NO. 207 U-BOLTS 1321 RIDGE AVE.
PITTSBURGH, PA 15233 MCJUNKIN CORP.
STUD BOLT - V0GT N0. 4.0402-017 P.O. BOX 513 HEX NUT - V0GT NO. 40616 CHARLESTON. VV 25322 BBC BROVN B0 VERI, INC.
NO. 54390-D28 BOLTS 1081 GREENTREE ROAD NO. 811878-T1 BOLT ASSEMBLIES PITTSBURGH, PA 15220 No. 54357F7 BOLTS No. 650141-AS1 SCREVS NO. 54343C-8 SCREVS NO. 54400C NUTS NO. 811878-T1 BOLT ASSEMBLIES b
LONE STAR SCREV CO.
ASME SA-193 GR B6 P.O. BOX 15221-(T)
ASME SA-193 GR B8 HOUSTON, TX 77020 ASME SA-325 TYPE 1 ASME SA-194 GR 2H
.ASME A-193 GR B7 ASME A-36 (VASHERS)
ASME SA-325 TYPE 1 ASME SA-194 GR 6 TYPE 410 l
ASTM A-326 (VASHER)
ASME SA-193 GR B7 ASME SA-194 GR 8 i
i BORG VARNER INDUSTRIAL PRODUCTS NO. 7000000-003 BOLTS FLUID CONTROLS DIVISION NO. 7000030-000 NUTS 7500 TYRONE NO. 7000030-000 LOCKVASHERS VAN NUYS, CA 91409 ATV00D & MORRILL CO., INC.
ASTM A-193 GR B8 285 CANAL STREET ASTM A-194 GR 8 SALEM, MA 01970 '
ATTACUMENT 1 Duquesnt Light Company Beaver Valley Power Station Safety-related Fastener Supplies PURCIIASED BY STONE & VEBSTER NAME & ADDRESS TYPE OF FASTENER T. J. COPE, INC.
No. H3 HEX NUTS 305 SECOND AVENUE NO. H4 MACHINE SCREVS COLLEGEVILLE, PA 19426 NO. H6 MACHINE SCREVS NO. H7 HEX NUTS NO. H1 MACHINE SCREVS COLT INDUSTRIES, INC.
No. 81-301-866 CAP SCREVS FAIRBANKS MORSE ENGINE DIV.
NO. 81-301-796 CAP SCREVS 701 LAVTON AVENlIE NO. 1260815 STUDS BELOTT, VI 53511 NO. 1260818 NUTS N0. 81340270N BOLTS No. 81334628N NUTS NO. 0000112.075.8 CAP SCREVS NO. P431805 SET SCREVS No. 11870994 U-BOLTS No.11908135 NUTS ITT BARTON NO. 1116.1007.J HEX HD BOLTS P.O. BOX 1882 NO. 0220.1009.J CP SCREVS NPS INDUSTRIES, INC.
ASME SA-193 GR B7 P.O. BOX 1535 ASME SA-325 TYPE I SECAUCUS, NJ 07094 ASME SA-194 GR 8 CORNER & LADA CO., INC.
FIG. No. 172 U-BOLTS 1341 ELHV00D AVENUE FIG. NO. 171 U-BOLTS CRANSTON, RI 02910 FIG. NO. 381 HEX NUT HARDVARE SPECIALTY CO., INC.
ASTM A-490 BOLTS 48-75 36TH STREET STAINLESS STEEL LOCKVASHERS LONG ISLAND CITY, NY 11101 ASTM A-194 GR 2H ASTM A-325 BOLTS PAN HEAD MACHINE SCREVS HEX NUTS TINNERMAN NUTS ASTM A-574 CAP SCREVS ASTM A-193 GR B7 SOUTHERN BOLT & FASTENER CORP.
ASME SA-193 GR B6 P.O. BOX 7196 ASME SA-194 GR B6 SHREVEPORT, LA 71107 ASME SA-193 GR B7 ASME SA-194 GR 2H ASTM A-194 GR B6 ASTM A-193 GR B7 ASTM A-194 GR 2H ASME SA-307 GR B ASME SA-194 GR 6 TYPE 410 ASME SA-194 GR 6 ASME SA-325 TYPE I ASTM A-490 ASTM A-325 (VASHERS)
ASME SA-193 B8
ATTACHMENT 1 Duquesn: Light Company in Beaver Valley "oa o
'ies Safety-related F.r r~
PURCHASED BY S _
(r JER NAME & ADDRESS TYPE OF FASTENER POVER & ENGINEERED PRODUCTS, INC.
ASME SA-325 TYPE I P.O. BOX 382 ASTM A-304 S.S. HEX HEAD BOLTS SOUTH PLAINFIELD, NJ 07080 ASTM A-304 S.S. LUCK VASHERS ASTM A-304 S.S. FLAT VASHERS ASTM A-304 S.S. U-BOLTS V/ NUTS ASTM A-540 GR B24 C.S. HIGH COLLAR LOCKVASHERS ASME SA-193 GR B6 ASME SA-193 GR B7 ASME SA-193 GR B8 ASME SA-194 GR 2H ASME SA-194 GR 8M ASTM A-490 ASME SA-194 GR 4 ASTM A-193 GR B7 R.E.C. CORPORATION ASME SA-193 GR B7 (0RIGINAL ADDRESS)
ASME SA-325 TYPE 7 2 SHERATON PLAZA ASME SA-194 GR 2H NEV ROCHELLE, NY 10081 ASME SA-193 GR B6 ASME SA-194 GR 6 TYPE 410 (CHANGE TO)
ASME SA-193 GR B8 10 BEACH STREET ASME SA-194 GR 8 HT. VERN0N, NY 10550 AFME SA-194 GR 8M ASTM A-193 CLASS 2A ASTM A-36 PLATE VASHERS ASTM A-193 GR B7 SA-540 GR 823 FITTED BOLTS TYPE B STANDARD WASHERS HIGH COLLAR LOCKVASHERS, C.S.
A-563 GR DH NUTS A-574 CAP SCREVS CARDINAL INDUSTRIAL PRODUCTS ASME SA-193 GR 88 3873 VEST 000END0 ROAD ASME SA-193 GR B6 LAS VEGAS, NV 89118 ASME SA-194 GR 6, ASME SA-193 GR B7 ASME SA-194 GR 2H ASME SA-320 GR B8 ASTM A-194 GR 8 ASTM A 490 ASTM A-194 GR 2H ASTM F-436 HARD VASHERS -.
ATTACHMENT 1 Duqu:sn2 Light Comp;ny Beaver Valley Povar Station Safety-related Fastener Supplies PURCHASED BY STONE & VEBSTER NAME & ADDRESS TYPE OF FASTENER HOB. INC.
ASME SA-193 GR B7 2146 FLINTSTONE DRIVE ASME SA-193 GR B8 TUCKER, GA 30084 ASME SA-193 GR B8 ASME SA-194 GR 6 ASME A-193 GR B6 ASME SA-453 GR 660 CL. 8 ASME SA-194 GR 2H ASME SA-193 GR B6 ASTM A-490 ASME SA-193 GR B16 ASME SA-194 GR 6 TYPE 410 ASME SA-325 TYPE I ASTM A-193 GR B7 ASTM AS/4 CAP SCREVS ASTM AS40 NUTS ASME SA-194 GR 7 AMERICAN FASTENER TECHNOLOGIES CORP SILICON BRONZE VASHERS, BOLTS (FORMERLY D.V. HANKEY FASTENER CO.) NUTS 2012 BABC0CK BLVD.
818.22.1 STEEL VASHERS PITTSBURGH, PA 15209 818.21.1 VASHERS ALLOY BOLTS SILICON BRONZE VASHERS, NUTS STAINLESS STEEL NUTS & VASHERS STAINLESS STEEL VASHERS B18.22.1 VASHERS CARBON STEEL VASHERS NUTSERT A36 OR A193-B7 NUTS SILICON VASHERS STAINLESS STEEL BOLTS, NUTS A193 BOLTS GR 10.9 NUT A325 TYPE 1 BOLTS A1SI-300 NUTS & BOLTS A193 B8. CL 1 BOLTS POVER PIPING COMPANY HEX NUT 829 BEAVER AVE.
NUT. ASTM A194 GR 2H PITTSBURGH, PA 15233 BOLT JAM NUTS A914-2H NUTS, FIG. 61 LOCKING NUT FIG. 61 A194-2H NUTS, FIG. 61 A194-2H NUTS -
i ATTACHNENT 1
[
-s:
Duquesne Lignt-Company Beaver Valley Power Station Safety-related Fastener Supplies
-l t
r PURCHASED BY STONE & VEBSTER NAME & ADDRESS TYPE OF FASTENER i
A&G ENGINEERING CO. II, INC.
ASME SA-193 GR B7 t
4640 E. LAPALMA AVE.
ASME SA-193 GR-B8 ANAHEIM, CA 92806 ASME SA-325 TYPE 1 l
ASME SA-194 GR 2H ASHE SA-194 GR 6 TYPE 410 ASME SA-194 GR 8 ASME SA-193 GR 88 TYPE 304 ASTM A-490 ASME SA-194 GR 8/8H ASME SA-193 GR B6 ASTM A-36 FLAT VASHERS ASME SA-194 GR 6 ASME SA-194 GR 7 ASME SA-540 GR 23 CL 5 ASME SA-320 GR B8 TYPE 304 STAINLESS STEEL PLAIN VASHERS i
ASME SA-320 GR B8 CL 1 l
ASME SA-193 GR B6 TYPE 410 BADEN STEELBAR & BOLT CO., INC.
CARBON STEEL, HARDENED VASHERS RT. #3 BIG SEVICKLEY CREEK RD.
818.3 BOLTS SEVICKLEY, PA 15143 CARBON STEEL GR 5 BOLT A193 GR B-7 BOLT t
STAINLESS STEEL STUDS A193 GR 8 OR 8H NUTS A193 GR B7 BOLTS A193 CR B8 BOLTS r
A193 GR B6 BOLTS STAINLESS STEEL VASHERS A913 GR B6, B16.5 ~i]D l
FASTENER HOUSS STEEL VASHERS BLDG. NO. 4 SAE J429 GR 8 BOLTS & NUTS 405 PARKVAY VIEV DRIVE B18.22.1 VASHERS PITTSBURGH, PA 15205 B18.21.1 VASHERS SILICON BRONZE BOLTS SILICON BRONZE VASHERS SILICON BRONZE NUTS STAINLESS STEEL VASHERS B18.2.1 BOLTS ATTACUMENT 1 t
Duqu;sns Light Company Beaver Valley Power Station Safety-related Fastener Supplies PURCHASED BY STONE & VEBSTER NAME & ADDRESS TYPE OF FASTENER D-EOLT COMPANY OF PENNSYLVANIA BOLTS, A307 GR B 1005 EIGHTH AVENUE SILICON BRONZE VASHERS, NUTS GLENEMAV, PA 15116 VASHERS STAINLESS STEEL NUTS CARBON STEEL VASHERS STEEL A325 BOLTS NUTS A194 GR 2H VASHERS B18.22.1 VASHERS STAINLESS STEEL BOLTS SILICON BRONZE VASHERS & NUTS SILICON BRONZE VASHERS A325 VASHERS 316 SS VASHERS B27.4 NUTS A307 BOLTS, VASHERS BRONZE PLATED VASHERS CARBON STEEL VASHERS 304 BOLTS, VASHERS, NUTS, S/S BOLTS, 18.8 S.S.
BOLTS FORGED OR BENT DUQUESNE LIGHT COMPANY ASTM A193 GR B7 C/0 STONE & VEBSTER ENGR., AGENT ASTM A194 GR 2H P.O. B0X 186 ASTM A325 TYPE 1 SHIPPINGPORT, PA 15077 Paco tio.
1 07/22/88 ATTACilMENT 2 DUQUESt1E LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED Nor1 SAFETY RELATED FASTENERS A.
B. CHANCE COMPANY 30-40 NORTHFIELD AVEt10E P.
O. BOX 6314 EDISO!1 NJ 08818 A.
B. DICK COMPANY OF PITTSBURGH 800 TRUMBULL DRIVE PITTSBURGH PA 16205 A. R. LHAMBERS & SON, INC.
111 35TH STREET PITTSBURGH PA 15201 AIRTEK, I t10.
RDn 3 ARONA ROAD P.O.
BOX 466 IRWIN PA 15642 AIRTEK, INC.
R.
D.
- 3, ARollA ROAD P.
O.
BOX 466 IRWIN PA 15642 ALBANY PRODUCTS CO.
145 WOODWARD AVEt1UE SOUTH NORWALK CT 06854 ALEXAt1 DER-PEN!1 (USE#89501) 945 PENN AVENUE PITTSBURGH PA 15222 ALFA-LAVAL, I tic.
350 DUTCHESS TUR11 PIKE POUGHKEEPSIE NY 12602 ALLEN-SHERMAN-HOFF COMPA!1Y C/O CESSCO CHATHAM TOWER, SUITE 11-C PITTSBURGH PA 15219 ALLIS CHALMERS CORP.
VALVE OPERATIONS 21010 CEt1TER RIDGE ROAD CLEVELAND OH 44116 ALLIS CHALMERS CORPORATION 1340 OLD FREEPORT ROAD P.
O.
BOX 11338 PITTSBURGH PA 15238
ige No.
2 s//22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS ALLIS CHALMERS HYDRO,(USE#1207)
F. O.
BOX M93 YORK PA 17405 AMERICAN FASTENER TECHNOLOGIES CORP 2012 BABCOCK BLVD.
PITTSBURGH PA 15209 AMERICAN PULVERIZER COMPANY 5540 WEST PARK AVENUE ST. LOUIS MO 63110 AMETEK/SCHUTTE & KOERTING DIV.
C/O BAKER PROCESS EQUIP.
CO.,
INC.
308 MOON CLINTON RD.,P. O.
BOX 898 CORAOPOLIS PA 15108 ANDERSON GREENWOOL, INC.
/0 ICE P. O. BOX 12895 PITTSBURGH PA 15241 ANIXTER DISTRIBUTION 700 TRUMBULL DRIVE PITTSBURGH PA 15220 APPARATUS ENGINEERING CO.,
INC.
BOX 53 TIRE HILL PA 15959 ATKOMATIC VALVE CO.,
INC.
141 S.
SHERMAN DR.
INDIANAPOLIS IN 46201
(
ATOMIC PRODUCTS CORPORATION 49 NATCON DRIVE P. O.
BOX R SHIRLEY NY 11967 ATWOOD & MORRILL CO.
285 CANAL ST.
SALEM MA 019/0 AURORA PUMP C/O RAMSAY PUMP & SUPPLY 1000 CALIFORNIA AVE.
PITTSBURGH PA 15233
i Page No-3 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS AUTOMATIC SPRINKLER CORP OF AMERICA P. O.
BOX 71 OAKMO; PA 15139 B & G MANUFACTURING COMPANY P. O.
BOX 269 HATFIELD PA 19440 B-G INDUSTRIAL SUPPLY COMPANY P. O.
BOX 472 IRWIN PA 15642 BADEN STEELBAR & BOLT COMPANY BIG SEWICKLEY CREEK ROAD R.
D. NO. 3 SEWICKLEY PA 15143 BADGER METER CO.
C/O FLOW MEDIA, INC.
P. O.
BOX 401 CARNEGIE PA 15106 BAILEY CONTROLS COMPANY 2020 ARDMORE BLVD., SUITE 205 ATTN:
WILLIAM T. FARRELL PITTSBURGH PA 15221 BAKER EQUIP. ENGINEERING CO. OF PA P.
O.
BOX 758 POTTSTOWN PA 19464 BARRETT,HAENTJENS & CO. OF PGH.
P. O.
BOX 12873 PITTSBURGH PA 15241 BARRON-BETHEA COMPANY C/O D.B.H. COMPANY P. O.
BOX 8287 PITTSBURGH PA 15218 BEACH-RUSS COMPANY 544 UNION AVENUE BROOKLYN NY 11211 BEARING DISTRIBUTORS, INC.
120 PUTNAM STREET PITTSBURGH PA 15206
e Page No.
4 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS BEARINGS & TRANSMISSION (USE#11F 1061 FORREST AVE.
WEST HOMESTEAD PA 15120 BEARINGS, INC.
615 PENNSYLVANIA AVE.
P. O. BOX 470 ROCHESTER PA 15074 BEARINGS, INC.
5536 BAUM BOULEVARD PITTSBURGH PA 15232 BECKMAN INDUSTRIAL CORP.
PROCESS INSTRUMENTS & CONTROLS DIV.
200 HIGHTOWER BLVD., SUITE 205 PITTSBURGH PA 15205 BECKWITH MACHINERY COMPANY P. O. BOX 8718 PITTSBURGH PA 15221 BERRY BEARING CO.
1103 PARKWAY VUE DR.
PITTSBURGH PA 15205 BERTRAND P. TRACY COMPANY DIV-OF WASHINGTON MOULD COMPANY P. O. BOX 518, GREEN & MADISON STS.
l WASHINGTON PA 15301 l
l BILTMORE PRODUCTS CO.,
INC.
3180 INDUSTRIAL BLVD.
l BETHEL PARK PA 15102 l
BIOMARINE, INC.
45 GREAT VALLEY PARKWAY l
MALVERN PA 19355 1
BRADLEY LIFTING CORP.
P. O.
BOX 28 l
EAST PROSPECT PA 17317 BRAUNLICH ROESSLE P.
O.
BOX 2831 PITTSBURGH PA 15230 BREATHING AIR SYSTEMS 3855 E. BROAD ST.
REYNOLDSBURG OH 43068
Page No.
5 07/22/88 i
DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS BRINKMANN INSTRUMENTS, INC.
CANTIAGUE ROAD WESTBURY NY 11590 BROOKS INSTRUMENT DIVISION C/O JOHN F.
KRAUS & CO.
801 W. MAIN STREET PITTSBURGH PA 15106 3UFFALO FORGE COMPANY 1115 ARCH STREET PITTSBURGH PA 15212 BUNKER RAMO CORPORATION 20 VALLEY STREET ENDICOTT NY 13760 BUSCH COMPANY 904 MOUNT ROYAL BOULEVARD PITTSBURGH PA 15223 BUTLER SERVICE GROUP TELECOMM. INC.
3300 BUCKEYE RD., SUITE 500 ATLANTA GA 30341 C & N PARTS, INC.
P.
O.
BOX 2008 MORGANTOWN WV 26505 C-E AIR PREHEATER, COMBUSTION ENG.
PITTSBURGH OFFICE & RESEARCH PARK BLDG.#1, SUITE 221,5500 CORPORATE DR PITTSBURGH PA 15237 C.
A. TURNER, INC.
P.
O.
BOX 77060 PITTSBURGH PA 15215 CARDINAL INDUSTRIAL PRODUCTS 3873 WEST OQUENDO LAS VEGAS NV 89118 CARMICHAELS MINING MACHINE REPAIR P. O.
BOX 373 CARMICHAELS PA 15320 CARRIER AIR CONDITIONING CO.
135 SOUTHPOINTE DR.
BRIDGEVILLE PA 15017
Page No.
6 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS CASHCO, INC.
C/O M. S: JACOBS & ASSOCIATES, INC.
810 NOBLESTOWN ROAD PITTSBURGH PA 15205 CENTRAL STATES INDUS (OUT OF BUSINESS) 29425 CHAGRIB BLVD.
PEPPER PIKE OH 44122 CHARLES TOOL & SUPPLY CO.
R. D.
- 2 SHIPPINVILLE PA 16254 CHARLES TOOL & SUPPLY COMPANY R.
D.
- 2 SHIPPINVILLE PA 16254 CHEMCON, INC.
30 MANN STREET SO. ATTLEBORO MA 02703 CHROMALLOY CORPORATION STURM MACHINE CO. DIV.
P. O.
BOX 277 BARBOURSVILLE WV 25504 CLARK-RELIANCE CORP.
C/O SEPCO CORP., BLDG. 100, SUITE 108 THOMPSON PARK DRIVE MARS PA 16046 CLIMET INSTRUMENTS 1320 W. COLTON AVENUE P. O.
BOX 151 REDLANDS sA 92373 CLOW CORP.
WATER SYSTEM GROUP 22255 CENTER RIDGE RD., SUITE 304 ROCKY RIVER OH 44116 CLOW CORPORATION CASTLE VILLAGE MALL SUITE 124 PITTSBURGH PA 15236 COLONIAL SUPPLY COMPANY P. O. BOX 44128 PITTSBURGH PA 15205
Page No.
7 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS COMBUSTION ENGINEERING, INC.
500 PENN CENTER BOULEVARD SUITE 125 PITTSBURGH PA 15235 COMMERCIAL FILTERS DIV.,
KENNECOTT CORP.
C/O V.
L. TOWNER Co., P.O. BOX 11193 PITTSBURGH PA 15237 COMPAIR MAKO COMPRESSORS, INC.
P.
O.
DRWER 1630 OCALA FL 32678 CONDON BROTHERS CO, INC.
1912 BRIGHTON ROAD PITTSBURGH PA 15212 CON 0 FLOW CORP.
C/O BILTMORE PRODUCTS CO.,
INC.
3180 INDUSTRIAL BLVD.
BETHEL PARK PA 15102 CONTINENTAL ELECTRIC COMPANY C/0 BURNS ELECTRIC COMPANY 3486 WILLIAM PENN HIGHWAY PITTSBURGH PA 15235 CONTROLMATICS 222 ROBERTS ST.
P. O. BOX 306 EAST HARTFORD CT 06108 COOKE-WILSON ELECTRIC SUPPLY CO.
131 FIRST STREET WAYNESBURG PA 15370 COPES VULCAN C/0 SEPCO CORPORATION BLDG. 100, SUITE 108, THOMSON PARK DR MARS PA 16046 CORNELL IRON WORKS, INC.
I CRESTWOOD INDUSTRIAL PARK MOUNTAIN TOP PA 18707 i
CRANE COMPANY l
VALVE SERVICING & REPAIR DIVISION 1120 OHIOVIEW AVE.,
P.
O.
BOX 246 AMBRIDGE PA 15003
Page No.
8 a
07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS CRANE COMPANY CHAPMAN DIVISION 203 HAMPIRE STREET INDIAN ORCHARD MA 01501 CRANE COMPANY VALVE DIV.
800 THIRD AVENUE, P. O. BOX 191 KING OF PRUSSIA PA 19406 CROSBY VALVE & GAGE COMPANY C/O A.
BLAIR POWELL CO.,
INC.
3849 WILLOW AVENUE PITTSBURGH PA 15234 CROSBY VALVE CO.
43 KENDRICK ST.
P. O. BOX 308 WRENTHAM MA 02093 CROWN AUGER MANUFACTURING, INC.
HIGHWAYS 12 & 137 CGKATA MN 56321 D-BOLT COMPANY OF PENNSYLVANIA 999 EIGHTH AVENUE GLENSHAW PA 15116 DAVIS CONTROLS CORP.
108 PARKWAY VIEW DRIVE PITTSBURGH PA 15205 DELL FASTENER CORPORATION 91 SOUTHPOINTE DRIVE BRIDGEVILLE PA 15017 t
DIAMOND POWER SPECIALTY CORPORATION 2020 ARDMORE BOULEVARD SUITE 205 PITTSBURGH PA 15221 i
DIGITAL EQUIPMENT CORP.
l 1500 ARDMORE BOULEVARD PITTSBURGH PA 15221 DRESSER INDUSTRIES DRESSER VALVE DIV.
l P. O. BOX 1430 l
ALEXANDRIA LA 71301 t
Page No.
9 07/22/88 DUQUESNE LIGHT CO.
i BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS DUQUESNE MINE SUPPLY COMPANY 2 CROSS STREET PITTSBURGH PA 15209 DURAMETALLIC CORP.
4866 DUFF DRIVE CINCINNATI OH 45246 DURAMETALLIC CORPORATION 4866 DUFF DRIVE CINCINNATI OH 45246 DYFOAM CORPORATION 202 EAST CHERRY STREET NEW CASTLE PA 16102 EATON CORPORATION P. O. BOX 6033N CLEVELAND OH 44193 EBERLINE INSTRUMENTS CORPORATION AIRPORT ROAD P. O.
BOX 2108 SANTE FE NM 87504 EDISON ELECTRIC INSTITUTE 1111 19TH STREET, NW WASHINGTON DC 20036 ELASTIMOLD DIVISION AMERACE CORPORATION P.O.
BOX 9149, CHURCH STREET STATION NEW YORK NY 10249 ELECTRO DEVICES (USE 3484)
C/0 JACK T. DOYLE COMPANY BOX X WEXFORD PA 15090 ELECTROFACT DIV. CONTROL DATA CORPORATION 2300 BERKSHIRE LANE NORTH PLYMOUTH MN 55441 ENERGY STEEL & SUPPLY 2715 PALDAN DRIVE AUBURN HILLS MI 48057
Pago No.
10 07/22/88 DUQUESNE LIGHT CC BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS ERIEZ MAGNETICS 454 MONTGOMERY AVENUE SUITE #1 BRIDGEVILLE PA 15017 ERWIN SUPPLY COMPANY P. O. BOX 5 SHINNSTON WV 26431 F & D SUPPLY COMPANY (USE 1085) 360 HELEN STREET MCKEES ROCKS PA 15136 FAIRMONT SUPPLY COMPANY P. O.
BOX 501 WASHINGTON PA 15301 FARWELL & HENDRICKS, INC.
PARK 50 TECHECENTER 1000 FORD CIRCLE, SUITE G MILFORD OH 45150 FELCO HYDRAULICS ARBOR INTERNATIONAL, INC.
143 ENTERPRISE DRIVE ANN ARBOR MI 48103 FISCHER & PORTER CO.
3 PARKWAY CENTER 875 GREENTREE ROAD PITTSBURGH PA 15220 FLOW MEDIA, INC.
AGM ELECTRONICS P. O. BOX 401 CARNEGIE PA 15106 FMC CORPORATZON (USE 0581)
MINING EQUIPMENT DIVISION P. O. BOX 2188 MORGANTOWN WV 26505 FOGLEMAN COMPANY, INC.
3849 WILLOW AVENUE P. O. BOX 10428 PITTSBURGH PA 15234 FORNEY ENGINEERING COMPANY P. O. BOX 189 ADDISON TX 75001
Page No.
11
-07/22/88-DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION.
VENDORS WHO HAVE' SUPPLIED NONSAFETY RELATED FASTENERS FORT PITT-PAINT & WELDERS SUPPLY CO 820 CHESTNUT STREET PITTSBURGH PA-15212 FOSTER WHEELER ENERGY CORPORATION 300 CORPORATE CENTER DRIVE SUITE 130 CORAOPOLIS PA 15108 FULLER COMPANY C/O MANN ENGINEERING' 3730 POPLAR AVENUE PITTSBURGH PA 15234 GARDNER DENVER COOPER INDUSTRIES 4499 CAMPBELLS RUN ROAD PITTSBURGH
-PA 15205
' GATEWAY INDUSTRIAL SUPPLY, INC.
ATTN:
BOB BROWN P. O. BOX 13171 PITTSBURGH PA 15243 GAULEY SALES COMPANY P. O. BOX 822 WASHINGTON PA 15301 GENERAL ELECTRIC COMPANY TWO GATEWAY CENTER PITTSBURGH PA 15222 GENERAL ELECTRIC COMPANY 200 HIGHTOWER BOULEVARD PITTSBURGH PA 15205 GENERAL ENVIRONMENTAL SCIENCE
.P. O. BOX 22294 BEACHWOOD OH 44122 GILLING ENGINEERING COMPANY 401 MOUNT NEBO ROAD PITTSBURGH PA 15237 GLOBE ELECTRIC COMPANY 23RD STREET PITTCBURGH PA 15215 GLOSSER EQUIPMENT 72 MESSENGER STREET JOHNSTOWN PA 15902
Pago No.
12 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS GOODING RUBBER COMPANY P. O. BOX 895 PITTSBUROH PA 15230 Gi:ECO WELDING SUPPLIES, INC.
P. O. BOX 349 TARENTUM PA 15084 GRINNELL FIRE PROTECTION SYSTEMS 201 COMMONWEALTH DRIVE WARRENDALE PA 15086 HANDLING PRODUCTS, INC.
1125 NORTH AVENUE PITTSBURGH PA 15221 HARDWARE SPECIALTY CO.,
INC.
48-75 36TH STREET LONG ISLAND CITY NY 11101 HARMONY INDUSTRIES R.
D.
- 1 GOULDS ROAD MINGO JUNCTION OH 43938 HARRIS CALORIFIC DIV. EMERSON ELECTRIC COMPANY 201 PARKWAY VIEW DRIVE PITTSBURGH PA 15205 HARRIS PUMP & SUPPLY COMPANY 5501 CAMPBELLS RUN ROAD PITTSBURGH PA 15205 HEATREX COMPANY WESCON INDUSTRIES,INC.
1272 S. MAIN STREET MEADVILLE PA 16335 HELICOPTER SYSTEMS, INC.
P. O.
BOX 221 SCOTTDALE PA 15683 HENRY PRATT COMPANY 401 S. HIGHLAND AURORA IL 60507 HENRY V0GT MACHINE COMPANY P. O.
BOX 1918 LOUISVILLE KY 40201
Pago No.
13 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS HEWIIT-ROBINS, INC.
DIVISION OF LITTON INDUSTRIES P.
O. BOX 299 PASSAIC NJ 070J5 HEYL & PATTERSON, INC.
250 PARK WEST DRIVE P.
O.
BOX 36 PITTSBURGH PA 15230 HILLS-MCCANNA COMPANY (USE 5937)
C/O PCF SALES CORPORATION 450 PORTER BUILDING PITTSBURGH PA 15219 HOFFMAN-KANE DISTRIBUTORS, INC.
5635 HORNING ROAD PITTSBURGH PA 15236 HONEYWELL INC.
1100 VIRGINIA DRIVE FORT WASHINGTON PA 19034 HUB, INC.
ENERGY PROCESS DIV.
2146 FLINTSTONE DRIVE TUCKER GA 30084 HUBBARD PUMP COMPANY BOX 10892 85 TERRENCE DRIVE PITTSBURGH PA 15236 HUGHES BROTHERS, INC.
C/O JUNG-LINDSAY ASSOCIATES P.
O.
BOX 477 CHAGRIN FALLS OH 44022 IDRECO-USA LIMITED 200 RITTEN HOUSE CIRCLE UNIT 5 EAST BRISTOL PA 19007 INDUSTRIAL RUBBER PRODUCTS COMPANY 294 CORLISS STREET PITTSBURGH PA 15220 ITT ENGINEERED VALVE UNIT OF ITT FLUID TECHNOLOGY CORP.
33 CENTERVILLE RD., P. O.
BOX 6164 LANCASTER PA 17603
Page No.
14 07/22/88 DUQUEONE LIGHT CO.
BEAVER VALL.IY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS J. A. SEXAUER P. O. BOX 1000 WHITE PLAINS NY 10602 J. E.
LONERGAN CO.
C/O. CHARLES W. STANGER 2316 CLARK BLDG, PITTSBURGH PA 15222 JAY INSTRUMENT & SPECIALTY CO.
1201 BANKSVILLE ROAD PITTSBURGH PA 15216 JENNER SALES P.
O.
BOX 86 PITTSBURGH PA 15547 JENNMAR CORPORATION 600 ARCH STREET CRESSON PA 16630 JERGUSON GAGE & VALVE CO.
C/O D. D.
FOSTER CO.
335 FIRST STREET PITTSBURGH PA 15215 JOSLYN CORPORATION P.
O.
BOX 368 9200 WEST FULLERTON AVENUE FRANKLIN PARK IL 60131 JOY TECHNOLOGIES, INC., MINING MACHINERY DIV., MEADOWN LANDS FACILITY, P. O. BOX 717, ROOM 91Q CANONSBURG PA 15317 LAPP INSULATOR COMPANY C/O MULLER HARPER, INC.
2406 NICHOLSON ROAD SEWICKLEY PA 15143 LAWRENCE PUMP & ENGINE COMPANY C/O JOHN PLACE, INC.
90 CLAIRTON BLVD.,
P. O.
BOX 10926 PITTSBURGH PA 15236 LEE-NORSE COMPANY P.
O.
BOX 230 WAYNESBURG PA 15370
Pago No.
15 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS LOJGE & SHIPLEY COMPANY 3055 COLERAN AVENUE CINCINNATI OH 45225 M. D. PNEUMATICS P. O. BOX 2877 4840 W. KEARNEY STREET SPRINGFIELD MO 65803 M. S. JACOBS & ASSOCIATES, INC.
810 NOBLESTOWN ROAD PITTSBURGH PA 15205 MAC-C0 SERVICE P. O. BOX 10396 PITTSBURGH PA 15234 MAHAFFEY EQUIPMENT COMPANY 650 ALPHA DRIVE PITTSBURGH PA 15238 MAPCO, INC.
PROCESS & POLLUTION CONTROL DIV.
1800 S.
BALTIMORE AVENUE TULSA OK 74119 MARAThuN INDUSTRIES, INC.
P. O. BOX 204 KIMBERLY WV 25118 MATIN SUPPLY COMPANY, INC.
36 TERMINAL WAY PITTSBURGH PA 15219 MCGINNES/ROYCE CORPORATION BOX 34543 HOUSTON TX 77034 MCGRAW--EDISON POWER SYSTEMS DIVISION 374 MILBURN AVENUE, P. O.
BOX 788 MILLBURN NJ 07041 MCMASTER-CARR SUPPLY COMPANY P. O. BOX 440 NEW BRUNSWICK NJ 08903 MD PNEUMATICS, INC.
C/0 BENNEY TECHNICAL SALES, INC.
207 PINE CREEK RD.,
SUITE 202 WEXFORD PA 15090
Page No.
16 e
07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS MECHANICAL TRANSMISSI (USE 0585)
P. O. BOX 18057 275 CURRY HOLLOW ROAD PITT6 BURGH PA 15236 MID STATE BOLT & NUT COMPANY, INC.
2350 ELDO ROAD MONROEVILLE PA 15146 MINE SAFETY APPLIANCES COMPANY P.
O. BOX 460 GLENSHAW PA 15116 MINING MACHINE PARTS (USE 5950F)
BOX 235 ROUT 286 N INDIANA PA 15701 MOONEY PROCESSING EQUIPMENT 7777 WALL STREET CLEVELAND OH 44125 MOORE PRODUCTS COMPANY 300 MOUNT LEBANON BOULEVARD PITTSBURGH PA 15234 MORRIS PUMPS, INC. (USE 3580R)
C/O RAMSEY PUMP & SUPPLY COMPANY P.
O.
BOX 5113 PITTSBURGH PA 15206 MORRISON-KNUDSEN COMPANY, INC.
POWER SYSTEMS DIVISION 101 GELO ROAD, P. O. BOX 1928 ROCKY MOUNT.
NC 27801 MULTIPLEX MANUFACTUi(ING COMPANY 600 F0WLER AVENUE BERWICK PA 18603 NATIONAL MINE SERVICE COMPANY MOUNTAINEER DIVISION 696 FAIRMONT ROAD (W. 0.)
MORGANTOWN WV 26505 NEWLAND ASSOCIATES, INC.
100 UNION STREET BRIDGEVILLE PA 15017 t
Page No.
17 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS NUS CORPORATION 910 CLOPPER ROAD GAITHERSBURG MD 20878 OLANDER & BROPHY, INC.
2300 ELDO ROAD P. O.
BOX 73 MONROEVILLE PA 15146 P. C. MCKENZIE COMPANY P. O. BOX 10396 PITTSBURGH PA 15234 PA & WVA SUPPLY CORP.
4075 WINDGAP AVENUE, BUILDING 10 KUTZ INDUSTRIAL PARK PITTSBURGH PA 15204 PALL-TRINITY-MICRO CORPORATION C/O BILTMORE PRDOUCTS COMPANY, INC.
3180 INDUSTRIAL BOULEVARD BETHEL PARK PA 15102 PENN GENERAL SUPPLY DIV.. PATTERSON INDUSTRIAL SUPPLY CO.,
P. O.
BOX 6 HEMPFIELD IND. PARK, P. O.
BOX 989 GREENSBURG PA 15601 PENN MACHINE COMPANY (USE 6724) 270 MEADOWLANDS BOULEVARD WASHINGTON PA 15301 PENN-BIRMINGHAM BOLT COMPANY P. O.
BOX 23 SCENERY HILL PA 15360 PENNSYLVANIA CRUSHER CORPORATION P. O.
BOX 100 BROOMALL PA 19008 PETERSON FILTERS CORPORATION P. O.
BOX 606 SALT LAKE CITY UT 84110 PI ENTERPRISES, INC.
3144 FIFTH AVENUE PITTSBURGH PA 15219
Pege No.
18 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS PI'rTSBURGH BOLT & SUPPLY COMPANY 114 V.I.P. DRIVE WEXFORD PA 15090 PITTSBURGH PROCESS EQUIPMENT CO.
640 LONG ROAD PITTSBURGH PA 15235 PLANT SERVICE COMPANY BINGHAM & SOUTH 6TH STREET PITTSBURGH PA 15203 PLUMBERS EQUIPMENT INC.
6260 BROAD STREET PITTSBURGH PA 15209 PORTERSVILLE VALVE COMPANY F. O. BOX 89 PORTERSVILLE PA 16051 POWER DISTRIBUTION PRODUCTS, INC.
C/O NATIONAL MINE SERVICE P. O. BOX 310 INDIANA PA 15701 PRECISION CONTROL PRODUCTS P. O.
BOX 9540 MADISON WI 53715 PROCESS SYSTEMS, INC.
C/0 T. H. SCHNEIDER INC.
P.
O.
BOX 522 FT. WASHINGTON PA 19034 PUTNAM, HAYS & BARTLETT, INC.
124 MOUNT AUBURN STREET CAMBRIDGE MA 02138 R.P.
ADAMS CO.
P.O.
BOX 963 BUFFALO NY 14240 RALPH A.
HILLER COMPANY 951 KILLARNEY DRIVE PITTSBURGH PA 15234 RAMSAY PUMP & SUPPLY COMPANY P. O. BOX 99775 PITTSBURGH PA 15233
Pago No.
19 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS RENOLD PTD 300 LARID STREET WILKES-BARRE PA 18702 RESEARCH COTTRELL, INC.
C/0 CENTRI DYNE EQUIPMENT COMPANY P. O.
BOX 186 MONROEVILLE PA 15146 RICHARDS-WILCOX MANUFACTURING CO.
316 WEST THIRD STREET AURORA IL 60507 RICOH CORPORATION CUSTOMER SERVICE GROUP BIN #14, 5 DEDRICK PL WEST CALDWELL NJ 07006 RITTER ENGINEERING COMPANY 540 DELWAR ROAD PITTSBURGH PA 15236 ROBBINS & MYERS INC. (USE 9377)
ATTN:
T. J. BLAKE 615 IRON CITY DRIVE PITTSBURGH PA 15205 ROBERT ANTHONY CASEY & ASSOCIATES 401 WOOD STREET SUITE 1600 PITTSBURGH PA 15222 ROCKWELL INTERNATIONAL FLOW CONTROL DIVISION 390 NORTH LEXINGTON AVENUE PITTSBURGH PA 15208 RUGGLES-KLINGEMANN MFG. CO.
C/O BOBAR INSTRUMENTS INC.
2491 GREENSBURG ROAD NEW KENSINGTON PA 15068 S & S CORPORATION P. O. BOX 230 WAYNESBURG PA 15370 SANGAM0 WESTON C/0 RUMSEY ELECTRIC COMPANY 55 GREAT VALLEY PARKWAY MALVERN PA 19355
r-Page No.
20 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS SCHINDLER ELEVATOR CORPORATION 360 VISTA PARK DRIVE VISTA INDUSTRIAL PARK PITTSBURGH PA 15205 SEPCO CORP. AGENT IOR WESTINGHOUSE ELECTRIC CO.,
BLDG. 100, SUITE 108 THOMPSON PARK DRIVE MARS PA 16046 SERVI-SEL, INC.
P.
O.
BOX 155 3210 INDUSTRIAL BOULEVARD BETHEL PARK PA 15102 SERVICE SUPPLY COMPANY, INC.
P. O. BOX 34 MCKEES ROCKS PA 15136 SKIL CORPORATION 3221-23 LIBERTY AVENUE PITTSBURGH PA 15201 SQUARE D COMPANY ANDERSON ELECTRIC DIVISION 300 MOUNT LEBANON EOULEVARD PITTSBURGH PA 15234 STANDARD MACHINISTS SUPPLY COMPANY 129 MCKEAN STREET PITTSBURGH PA 15219 STANLEY G. FLAGG & COMPANY, INC.
1020 WEST HIGH STREET STOWE PA 19464 STATE EQUIPMENT CORPORATION 400 SECO ROAD MONROEVILLE PA 15146 STATHAM DIV. SOLARTRON TRANSDUCERS C/O GILSON ENGINEERING SALES, INC.
978 PERRY HIGHWAY PITTSBURGH PA 15237 STATON INDUSTRIAL ELECTRIC SUPPLY 521 PENN AVENUE PITTSBURGH PA 15221
W Page No.
21 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS STEPHENSON ADAMSON DIVISION ALLIS'CHALMERS P.
O.
BOX 11338 PITTSBURGH PA 15238 STOCK EQUIPMENT COMPANY C/O SEPCO CORPORATION, BUILDING 100 SUITE 108, THOMSON PARK DRIVE MARS PA 16046 SUB-AQUATICS, INC.
1428 BANSVILLE ROAD PITTSBURGH PA 15216 SUPERIOR SPECIALTY COMPANY 256 KAPPA DRIVE PITTSBURGH PA 15238 SUPERIOR VALVE COMPANY 2200 N. MAIN STREET WASHINGTON PA 15301 T. J. COPE C/O RANSFORD 5400 CLAIRTON BOULEVARD PITTSBURGH PA 15236 T. J. HAYS ASSOCIATES 1106 REEDSDALE STREET PITTSBURGH PA 15233 TELEDYNE FARRIS ENGINEERING C/O FOGLEMAN CO.,
INC.
P. O.
BOX 10428 PITTSBURGH PA 15234 THE BABCOCK & WILCOX (USE #0554)
CUSTOM PRODUCTS SALES l
SUITE 320, 3340 WEST MARKET STREET AKTRON OH 44313 THE DEMPLER COMPANY 79 NORTH INDUSTRIAL PARK SEWICKLEY PA 15143 THE DURIRON COMPANY, INC.
PPI LOCK BOX 92426-N CLEVELAND OH 44193 l
l
'Pago yo, gg 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VEND 0RS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS THE FASTENER HOUSE INC.
405 PARKWAY VIEW DR. - BLDG'. 4 PITTSBURGH PA 15205 THE FASTENER HOUSE INC.
405 PARKWAY VIEW DRIVE BUILDING #4 PITTSBURGH PA 15205 THE FOXBORO COMPANY SUITE 415 2550 MOSSIDE BOULEVARD MONROEVILLE PA 15146 THE NASH ENGINEERING COMPANY 25850 FIRST STREET WESTLAKE OH 44145 THE STAHURA COMPANY, INC.
536 PITTSBURGH STREET P. O.
BOX 122 SPRINGDALE PA 15144 THE WILLIAM POWELL COMPANY 2503 SPRING GROVE ROAD P. O. BOX 145434 CINCINNATI OH 45214 TUG MANUFACTURING COMPANY DEPARTMENT TR P. O.
BOX 6421 MARIETTA GA 30065 TURBINE SERVICES, LTD.
R.
D.
- 2 ROUTE 50 BALLSTON SPA NY 12020 TYMSHARE, INC.
31355 WEST AGOURA ROAD WEST LAKE VILLAGE CA 91361 UNISTRUT PITTSBURGH SERVICE CO.
711 PARKWAY VIEW DRIVE P. O.
BOX 44103 PITTSBURGH PA 15205 UNITED CONVEYOR CORPORATION C/O CRAIG EQUIPMENT COMPANY P.
O.
BOX 10600 - 670 RODI ROAD PITTSBURGH PA 15235
Page No.
23 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS UNITED TECHNOLOGIES ELLIOTT P.
O.
BOX 186 MONROEVILLE PA 15146 UTILITIES SERVICE COMPANY C/O BURNS ELECTRIC COMPANY 3486 WILLIAM PENN HIGHWAY PITTSBURGH PA 15235 V.
L. TCWNER COMPANY C/O KOCH FILTER COMPANY P. O.
BOX 11193 PITTSBURGH PA 15237 VALCOR ENGINEERING CORP.
2 LAWRENCE ROAD SPRINGFIELD NJ 07081 VELAN STEAM TRAP (USE 6742)
BEEKMANTOWN ROAD P.
O.
BOX 220 PLATTSBURG NY 12901 VELAN VALVE CORPORATION 2125 WARD AVENUE MONTREAL, QUEBEC H4M-1TC VELAN VALVE CORPORATION 2125 WARD AVENUE j
MONTREAL, QUEBEC H4M-1T6 W.
F. STUCKEMAN COMPANY 18 RUTH STREET PITTSBURGH PA 15211 W.
H. SALISBURY C/O BURNS ELECTRIC COMPANY 3486 WILLIAM PENN HIGHWAY PITTSBURGH PA 15235 WALWORTH COMPANY P.
O.
BOX 873 VALLEY FORGE PA 19481 WARMAN INTERNATIONAL, INC.
C/O KISSICK CORPORATION 108 BENSON EAST JENKINTOWN PA 19046
Page No.
24 07/22/88 DUQUESNE LIGHT CO.
BEAVER VALLEY POWER STATION VENDORS WHO HAVE SUPPLIED NONSAFETY RELATED FASTENERS WEBER WELDING SUPPLY COMPANY 3220 SMALLMAN STREET PITTSBURGH PA 15201 WEMCO DIVISION 4200 FIRST AVENUE SUITE 206 NITRO WV 25143 WEST PENN OIL EQUIPMENT COMPANY 3025 BRIGHTON ROAD PITTSBURGH PA 15212 WESTRONICS, INC.
C/O GILSON ENGINEERING SALES 978 PERRY HIGHWAY PITTSBURGH PA 15229 WHEEL & RIM SALES COMPANY 39TH AT BUTLER ST.,
19D PITTSBURGH PA 15201 WILLIAMS & COMPANY, INC.
901 PENNSYLVANIA AVENUE PITTSBURGH PA 15233 WILSON-SNYDER PUMPS OILWELL DIVISION 4991 WILLIAM FLYNN HIGHWAY GIBSONIA PA 15044 WM. W.
MEYER & SONS, INC.
P. O. BOX 105 SMOKIE IL 60076 YARWAY CORPORATION BLUE BELL PA 19422 ZENITH SUPPLY CO.,
INC.
50 32ND STREET PITTSBURGH PA 15201 ZURN INDUSTRIES, INC.
MECHANICAL DRIVES DIV.
600 N. BELL AVE., SUITE 221, BOX 452 CARNEGIE PA 15106
ATTACHMENT 2 Duquesne Light Company Beaver Valley Power Station-Non-safety related Fastener Supplies 1
PURCHASED BY SCHNEIDER NAME & ADDRESS TYPE OF FASTENER THE FASTENER HOUSE TOGGLE BOLTS 405 PARKVAY VIEV DRIVE DROP FORGED-GALV. EYE BOLTS PITTSBURGH, PA 15205 STL.-ZINC PLTD.
A307 SIL. BRONZE HARDENED SIL.
A563 18/8 STAINLESS GR 2 STL.-ZINC PLTD.
SERVICE SUPPLY-CO., INC.
A325 11 SHINGISS STREET DROP FORGED-GALV.
MCKEES ROCKS, PA 15136 TOGGLE BOLTS BRASS STL.-ZINC PLTD.
A307 18/8 STAINLESS ALUMINUM FASTENERS UNLIMITED STL.-ZINC PLTD.
117 MONT0UR VEST IND. BLVD.
TOGGLE BOLTS CORA0 POLIS, PA 15108 DELL FASTENER CORP.
TOGGLE BOLTS 91 SOUTH POINTE DRIVE STAINLESS STEEL BRIDGEVILLE, PA 15017 VILLIAMS & COMPANY 18/8 STAINLESS 901 PENNA. AVE.
PITTSBURGH, PA 15233 CONSTRUCTION TOOL SERVICE, INC.
STL.-ZINC PLTD.
3616 LIBERTY AVENUE EYE COLTS PITTSBURGH, PA 15201 MID-STATE BOLT & NUT STL.-ZINC PLTD.
2350 ELD 0 ROAD MONROEVILLE, PA 15146 AMBRIDGE ELECTRIC SUPPLY STL.-ZINC PLTD.
1320 MERCHANT STREET AMBRIDGE, PA 15003 STEINFIELD'S HARDVARE TOGGLE BOLTS 345 MAIN AVENUE V. ALIQUIPPA, PA 15001 VESTINGHOUSE ELECTRIC SUPPLY STL.-ZINC PLTD.
STH AVENUE & 14TH ST.
NEV BRIGHTON, PA 15066 1,
ATTACHMENT 2 Duquesna Light Company Beaver Valley Power Station Non-safety related Fastener Supplies PURCHASED BY SCHNEIDER NAME & ADDRESS TYPE OF FASTENER BADEN STEELBAR.& BOLT
.18/8 STAINLESS BIG.SEVICKLEY ROAD A193 GR B7 SEVICKLEY, PA 15143 CITY HARDVARE CO.
STL. -ZINC ' PLTD.
726 MIDLAND AVE.
TOGGLE BOLTS HIDLAND, PA 15059 MILLER'S HARDVARE & SUPPLY STL.-ZINC PLTD.
739 MIDLAND AVE.
TOGGLE BOLTS MIDLAND, PA 15059 STEEL NUTS FLATVASHERS' LOCKVASHERS H. H. BOLTS -
3RASS SHENANGO IND. SUPPLY, INC.
TOGGLE BOLTS 110 N. HERCER AVENUE STL.-ZINC PLTD.
SHARPSVILLE, PA 16150 i
i I
l l
(
$ t
.1
' ATTACHMENT 2 q
Duquesne Light company-Beaver Valley Power. Station Non-safety.related Fastener Supplies PURCHASED BY SARGENT ELECTRIC NAME & ADDRESS TYPE OF FASTENER BASIC ENGINEERS FIG. 60 BOLTS 701 ALPHA DR.
PITTSBURGH, PA 15238 BADEN STEELBAR & BOLT ALL THRD. R0D ASTM A307 ROUTE-3 ASTM A193-78 GR B7 SEVICKLEY, PA 15143 ASTM A194-78 2H ALL THRD. R0D B7 NUTS ASTM A325 ASTM A194 GR 2H ALL THRD. R0D A307 GR A ALL THRD. ROD A563 GR A ASTM A193-82 GR B ASTM A194-82 GR 2H A193 GR B7 A325 BOLTS GR 5 ALL THRD. R0D ASTM A36 ASTM A563-83A GR A ALL THRD. R0D ASTM A193-81 GRB7 ASTM A194-81 GR 2H ALL THRD. ROD ASTM A193-82 GRB7 ASTM A194-82A GR 2H ALL THRD. R0D ASTM A193 GR B7 1P 304SS 18-8 ASTM A307-83A A563-83A ASTM A307-GR2 ASTM A194-82A GR 2H CODY ASSOCIATES HCC 5037 125EG 711 PARK VIEV DR.
HCC 5025 150EG PITTSBURGH, PA 15205 ASTM A194 G8 CORNER & LADA ASTM A193 GR 2M 1341 ELMV00D AVE.
CRANSTON, RI 02910 i
D-BOLT CO.
18-8 SS 1005 EIGHTH AVE.
A193 B7 GLENSHAV, PA 15116 A194 GR 2H A325 A307 GR B ASTM A563 ASTM A193-81 GR B7 ASTM A194-81A GR 2H ASTM 00-B-626-268 ASTM A307-81 GR B ASTM A563-81 GR A f
V l-ATTACHNENT 2 Duquesne Light Company 3
Beaver' Valley Pover Station Non-safety related Fastener Supplies PURCHASED BY SARGENT ELECTRIC NAME &' ADDRESS TYPE OF FASTENER DELL FASTENER A325-74 91 SOUTHPOINTE DR.
A194-78 GR 2H BRIDGEVILLE, PA 15017 A193 GR 8 ASTM A194 GR 2H ASTM A307 ALL THRD. ROD ASTM A36 ASTM A194 GR 2H ASTM A193-81 GR B ASTM A194-81 GR 2H ASTM A193-81 GR B7 ASTM A193-81A GR B7 ASTM A194-81A GR 2H ASTM A307-80 GR A ASTM A563-80 GR A ALL'THRD. R0D ASTM A307 20 ASTM 194-81 GR 2H ASTM A193-81A B7 ASTM A307-83A ASTM A563-83A ASTM A194-82A GR 2H ASTM A193-82 GR B7 ASTM A193 GR B7 THE GAGE CO.
CAP SCREVS B0X 1168 PITTSBURGH. PA 15230 FASTENER HOUSE A193 GR B7 s
405 PARKVIEV DR.
A194 GR 2H PITTSBURGH, PA 15205 A325 FASTENERS UNLIMITED ASTM A307 GR S 117 MONT0UR V. IND. PARK ASTM A194 GR 2H CORA0 POLIS, PA 15108 ASTM A193 GR B7 ASTM A193 GR B8 ASTM A325 SS BOLTS & NUTS SAE GR 5 ASTM A194-24 ASTM A325-81 BOLTS SAE GR 5 A307 GR A V/A563 ALL THRD. ROD A-193 B7 BRASS M S 10-24 H S r
ASTM A-307 A563 ASTM A193-83 GR B7
. i l
hk i
'9
+
C '
I' '
ATTACHMENT:2 Duquesne Light Company Beaver Valley Power Station Non-safety related Fastener Supplies PURCHASED BY SARGEPTP ELECTRIC '
- NAME & ADDRESS TYPE OF FASTENER.
MCHASTER-CARR BOLTS #92436A548 1P.O. BOX 440 NEV BRUNSVICK, NJ 08903 HENDEL STEEL A325-86A TYPE I 3017 SOUTH PARK RD.
A193 GR B7 BETHEL FARK, PA 15102 A194 GR 2H ROBOT INDUSTRIES NON-HARDENED H-BOLT 7043 ORCHARD DEARBORN, MI 48216 SUPPLY GROUP INC.
HEX NUTS 6260 BROAD ST.
HEX NUTS PITTSBURGH, PA 15206 ALL THRD. R0D FIG. 146 VEST PENN SUPPLY CO.
A193 GR BY CL-151 4800 GRAND AVE.
PITTSBURGH, PA 15225 VILLIAMS & CO.
ASTM A240 TP304 SS 901 PENNSYLVANIA AVE.
PITTSBURGH, PA 15233 ZENITH SUPPLY NUTS & BOLTS 50 32ND ST.
PITTSBURGH, PA 15201 POVER PIPING CO.
BOLTS FIG. 60 829 BEAVER AVE.
NUT FIG. 61 PITTSBURGH, PA 15233 R0D FIG. 81 ROD FIG. 81L ALL THRD. ROD A36 R0D FIG. 81RL i'
a
_S.
i.
y o
d s
ATTACHKENT 2 i
Duquesne Light Company Beaver Valley Power Station Non-safety-related Fastener Supplies 1
PURCHASED BY DICK CORPORATION NAME & ADDRESS TYPE OF-FASTENER BARBARA BOLT & NUT CO.
BOLT
' 208 PARKVAY DRIVE NUT ROBINSON TOVNSHIP, PA GALV. NUTS CITY H/RDWARE CO.
NUTS 726 MIDLAND AVE.
BOLTS MIDLAND, PA 15059 MILLER HARDWARE NUTS 838 BEAVER GRADE RD.
BOLTS CORA0 POLIS, PA TOGGLE BOLTS IRVIN INDUSTRIAL $ MINE SUPPLY CO.
A325
. 15051 RTE. 30 NORTH HUNTINGTON, PA BADEN STEELBAR & BOLT A-325 BOLTS, NUTS BIG SEVICKLEY CREEK RD.
BOLTS SEVICKLEY, P.-
A307 BOLT, NUT l
i.
t s - -
qi; N cp o ;
ATTACHMENT.2
,e%f' Duquesne Light Company
' Beaver Valley Power Station-Non-safety related Fastener Supplies PURCHASED BY STONE'&'VERSTER v.c NAh8 & ADDRESS TYPE OF FASTENER BARBARA BOLT & NUT CO.
-NUTS & VASHERS 208 PARKVAY VTEV DR.
B188.6.3 BOLTS PAR"VAY VEST INDUSTRIAL PARK '
PITISBURGH, PA 15205 CEORGE L. VILSON & COMPANY BOLTS 220 E. GENERAL ROBINSON ST.
PITTSBURGH, PA 15212 BBC BROVN B0 VERI, INC.
NO. 54390-A6 BOLTS 1081 GREENTREE ROAD NO. 54390-A3 BOLTS PITTSBURGH, PA 15220 NO. 650434-A3 NUTS NO. 650439-A NUTS No. 54390-Al BOLTS NO. 54396D04 BOLTS CORNER &~LADA CO., INC.
FIG. N0. 172 U-BOLTS 1341 ELMV00D AVENUE CARNSTON,-RI 02910 HARDVARE SPECIALTY CO., INC.
A1SS 18-8 BOLTS 48-75 36TH STREET A1S1 18-8 NUTS LONG ISLAND CITY, NY 11101 A151 18-8 FLAT VASHERS ASTM A-563 GR DH NUTS CARBON STEEL HIGH COLLAR LOCKVASHERS ASTM A-307 NUTS ASTM-A-194 GR 2H ASTM A-193 GR B8 ASTM A-194 GR 8 ASTM A-193 GR B7 ASTM A-194 GR 6 ASTM A-3 M S.S. NUTS SOUTHERN BOLT & FASTENER CORP.
ASTM A-19 GR B7 P.O. B0X 7196 ASTM A-194 'R 2H SHREVEPORT, LA 71107 POVER & ENGINEERED PRODUCT, INC.
ASTM A-194 GR 8 P.O. BOX 382 ASTM A-193 GR B8 SOUTH PL.iINFIELD, NJ 07080 A&G ENGINEERING CO. II, INC.
ASTM A-193,R B7 4640 E. LAPALMA AVE.
ASTM A-194 R 2H ANAHEIM, CA 92806
- V ATTACHME!E 2 Duquesne Light. Company Beaver Valley Pover Station Non-safety related Fastener Supplies PURCHASED BY STONE & VEBSTER NAME & ADDRESS TYPE OF FASTENER
.BADEN STEELBAR & BOLT CO. INC.
A307 COUPLINGS RT. #3 BIG SEVICKLEY CREEK RD.
A193 GR B8 BOLT SEVICKLEY, PA 15143 A194 GR-8H' NUTS A913 GR B7 BOLTS A307 NUTS A193 GR B8 BOLTS-GRADE 5 BOLTS CARBON STEEL BOLT CARBON STEEL LOCKVASHERS A194 GR 2H NUT FASTENER HOUSE B18.22.1 VASHERS BLDG. NO. 4 STEEL BOLTS 405 PARKVAY VIEV DRIVE GRADE 1035 - ASTM A29 NUTS PITTSBURGH, PA 15205 TYPE G291 BOLT A325 VASHERS A307, GR 8 BOLTS A307 NUTS A563 GR C-3 NUTS BOLTS & NUTS LOV ALLOY STEEL BOLTS & NUTS B18.2.2 NUTS B18.21.1 VASHERS B18.2.1 BOLTS i
B27.4 TYPE A OR B VASHERS GR 5 COUPLINGS B18.6.3 BOLTS 304 S.S. BOLTS, NUTS, STUDS, VASHERS AMERICAN FASTENER TECHNOLOGIES CORP 18-8 STAINLESS STEEL BOLTS (FORMERLY D.V. HANKEY FASTENER CO. ) BOLTS 2012 BABC0CK BLVD.
A325 VASHERS PITTSBURGH, PA 15209 TYPE 304 STNLS STEEL VASHERS B18.17 NUT A276 TYPE 304 BOLT SILICON BRONZE NUTS STAINLESS STEEL 18-8 OR 304 NUTS, BOLTS, VASHERS STAINLESS STEEL NUTS BOLTS, NUTS, VASHERS, S.S.
304 SS BOLTS 18-8 OR 300 SERIES STAINLESS STEEL NUTS A325 BOLTS 302 VASHERS NUTS A325 VASHERS STAINLESS STEEL RINGS BOLTS CARBON STEEL NUTS 304 R0D
's v!C ATTACHMENT 2 E
s' Duquesne Light Company R
Beaver Valley _ Power Station Non-safety.related Fastener Supplies s.
PURCHASED BY STONE & VEBSTER NAME & ADDRESS TYPE OF FASTENER D-BOLT COMPANY OF PENNSYLVANIA BOLTS & NUTS A307 GR B
- 1005 EIGHTH AVENUE NUTS A307 GLENSHAV, PA ~15116 BOLTS A307 GR A EYENUTS VASHERS B18.22.1 VASHER A307 GR B NUTS B18.2.2 BOLTS B18.2.1 NUTS B18.2.2 BOLTS B18-6-3 BOLT CARBON STEEL BOLT & VASHER A36 VASHERS A325 BOLTS B18.6.3 BOLTS A325 NUTS 194 GR 8-VASHERS 304 SS NUTS A563 GR C-3 NUTS & VASHERS GR 18-8 VASHERS B18.22.1 BOLTS & NUTS SILICON BRONZE BOLTS STAINLESS STEEL NUTS SILICON BRONZE NUTS DROP FORGED SCREVS VASHERS CARBON STEEL VASHERS STAINLESS STEEL BOLTS CARBON STEEL BOLTS & VASHERS A304 VASHERS 316 i
BOLTS, NUTS VASHERS 302 NUTS, VASHERS STEEL VASHERS SCREVS STAINLESS STEEL VASHERS STAINLESS STEEL POVER PIPING COMPANY HEX NUT FIG. 61 819 BEAVER AVE.
NUT FIG. 162 PITTSBURGH, PA 15233 NUTS FIG. 61 ASTM A307B EYENUT FIG. 162 ASTM A36 NUTS & STUDS BOLTS A193. G4 B7 NUTS A194 GR 2H DUQUESNE LIGHT COMPANY SA1193 GR B7 C/0 STONE & VEBSTER ENGR., AGENT SA194 GR 2H P.O. BOX 186 A325 SHIPPINGPORT, PA 15077