_ _ _ _ _ _ _ _ _

84 Northern States Power Company 414 Nice!!et P.8M Mnneapoks Mnnesota 55401 Tetephone (612) 330 5500 April 12, 1988 NRC Sulletin 88-02 Director of Nuclear Reactor Regulation U S Nuclear Regulatory Commission Attn:

Document Control Desk 1

Washington, DC 20555 l

PRAIRIE ISIRiD NUCLEAR CENERATING PIRIT Docket Nos. 50-282 License Nos. DPR-42 50 306 DPR-60 Additional Resnonse to NRC Compliance Bulletin 88-02 Ref:

Letter dated March 24, 1988, from C E Larson, USP, to Direct,.

of NRR, "Response to NRC Compliance Bulletin 88-02" The purpose of this letter is to provide information to supplement our March 24, 1988 response to NRC Compliance Bulletin 88 02.

Att. ached is a copy of Westinghouse report WCAP-ll788, ' Prairie Island Units 1 and 2 Evaluation for Tube Vibration Induced Fatigue," March, 1988.

This report documents the evaluation of steam generator tubing at Prairie Island Units 1 and 2 for susceptibility to fatigue-induced cracking of the type experienced at North Anna Unit 1.

For both Unit 1 and Unit 2 at Prairie Island, the results of the Westinghouse evaluation indicate that all tubes have acceptable fa-tigue usage and no corrective actions are required.

Five copies of the Westinghouse Proprietary Class 2 version of this report, WCAP-ll787, are also attached for NRC Staff review. Also attached is a Westinghouse authori::ation letter, CAW-88-125, "Applica-tion for Withholding Proprietary Information from Public Disclosure,"

March 25, 1988.

As WCAP-ll787 contains information proprietary to Westinghouse Elec-tric Corporation, it is supported by an affidavit signed by Westing-house, the owner of the information.

The affidavit sets forth the basis ot. which the information may be withheld from public disclosure

'{3 gtf ATTACHMENT CONTAINS 10 CFR SECTION 2.790 PROPRIETARY INFORMATION 3(V TO BE WITHHELD FROM PUBLIC DISCLOSURE l gPA i

6804210327 080412 PDR ADOCK 050 2

c g sM 31!L g-ch pss e l

l NP pp.t.PPR i

iNY Lf9R t

, I ff )

Director of NRR Nodhem States Power Company April 12, 1988 Page 2 by the Commission and addresses with specificity the considerations listed in paragraph (b)(4) of Section 2.790 of the Commissions regula-tions.

Correspondence with respect to the proprietary aspects of the Applica-tion for Withholding or the supporting Westinghouse Affidavit should reference CAW 88-025 and should be addressed to R A Viesemann Manager of Regulatory & Legislative Affairs, Westinghouse Electric Corpora-tion, PO Box 355, Pittsburgh, Pennsylvania 15239-0355.

CELarsh I

Vice Pres 14 erg,,Iuclear Generation c:

Regicnal Administrator, Region III, NRC*

Sr Resident Inspector, NRC NRR Proj ect Manager, NRC G Charnoff

  • Includes one copy of WCAP ll787 (Proprietary)

Attachments ATTACllMENT CONTAINS 10 CFR SECTION 2.790 PROPRIETARY INFORMATION TO BE WITilHELD FROM PUBLIC DISCLOSURE i

]

UNITED STATES NUCLEAR REGULATORY COMMISSION NORTHERN STATES POWER COMPANY PRAIRIE ISLAND NUCLEAR GENERATING PLANT DOCKET NO. 50-282 50-306 ADDITIONAL RESPONSE TO NRC COMPLIANCE BULLETIN 88-02 Northern States Power Company, a Minnesota corporation, with this letter is submitting information requested by NRC Compliance Bulletin 88-02.

This letter contains no restricted or other defense information.

NORTHERN STATES POWER COMPANY By C E La son Vice P eside Nuclear Generation On this day of

/>[/ b,$88 before me a notary public in and for said County, persdnally appeared C E Larson, Vice President Nuc-lear Generation, and being first duly sworn acknowledged that he is authorized to execute this document on behalf of Northern States Power Company, that he knows the contents thereof, and that to the best of his knowledge, information, and belief the statements made in it are true and that it is not interposed for delay.

)/L 1 e t tL)

(

U

\\

I"NNWWWwMmwmmas MARQA A tsCOnt

l l

NOTARY PUBUC--MINNESOTA l

HINNEPIN COUhTY l l l

My Commese tigres sept 24 1993 r..^^::::::::^..:^:.:::::.:.::.:.l

_-