n.n cu -
^w"~'n
- c v
inu n: ':. u '
Donidi S hneII ryg 1 1BLucruic E
July 22, 1988 U.S.
Nuclear Regulatory Commission Attn Document Control Desk Mail Station P1-137 Washington, D.C.
20555 Gentlemen:
ULNRC-1811 DOCKET NO. 50-483 CALLAWAY PLANT FASTENER TESTING TO DETERMINE CONFORMANCE WITH APPLICABLE MATERIAL SPECIFICATIONS
References:
- 1) NRC Bulletin No. 87-02, Supplement 1, dated April 22, 1988
- 2) NRC Bulletin No. 87-02, Supplement 2, dated June 10, 1988 NRC Bulletin 87-02, Eupplements 1 and 2 required licensees to provids a list of suppliers and manufacturers of fasteners for each facility.
This information was to be provided to the NRC within 90 days of receipt of Supplement 1 (July 22, 1988).
Attached are Union Ele:tric's listings of suppliers and manufacturers.
Attachments 1 and 2 consist of the direct and indirect supplicrs of safety-related fasteners to Union Electric.
Attachments 3 and 4 are listings of direct and indirect suppliers of non-safety-related fasteners.
The information provided in these attachments is essentially complete.
Some information for fasteners that were purchased on Bechtel or Daniel purchase orders and received after plant startup in 1984, was unavailable.
Union Electric considers that this is a negligible quantity (less than 1%) and that the intent j
of Bulletin 87-02, Supplements 1 and 2 has been met, i
j esoso20160 080722
'/
gDR ADOCK0$00$$@3 f
I o
If you have any questions concerning this information, please contact me.
Very truly yours, n
Donald F.
Schnell WEK/ dis Attachments t
i l
I
STATE OF MISSOURI )
)
Donald P.
Schnell, of lawful age, being first duly sworn upon oath says that he is Senior Vice President-11uclear and ar.
officer of Union Electric Company; that he has read the foregoing document and knows the content thereof; that he has executed the satte for and on bthalf of said company with full power and authority to do so; and that the facts therein stated are true and correct to the best of his knowledge, information and belief.
By
( Ota
. et J
Donald P.
Schnell Senior Vice President fluelear SUBSCRIDED and sworn to before me this M 4/ day of al.
198[.
A tb Ltd -
h/k/
t Eu n M R A'I. 'F F # [f b hm Arr tvMr. $tAtt tr uts!cun WY (Cvu #sta (th6Li hR4 ;l li4J ST. LOUI5 COLNTt
cc Gerald Charnoff, Esq.
Shaw, Pittman, Potts & Trowbridge 2300 N. Street, N.W.
Washington, D.C.
20037 Dr. J. O. Cermah CTA, Inc.
4 Professional Drive (Suite 110)
Gaithersburg, MD 20879 R. C. Knop Chief, Reactor Project Dranch 1 U.S. Nuclear Regulatory Commission Region III 799 Roocevelt Road Glen Ellyn, Illinois 60137 Bruce Little Callaway Resident Office U.S.
Nuclear Regulatory Commission RRi1 Steedman, Missouri 65077 Tom Alexion (2)
Office of Nuclear Reactor Regulation U.S.
Nuclear Regulatory Commission Mail Stop 316
]
7920 Norfolk Avenue t
Bethesda, MD 20014 I
Manager, Electric Department i
Missouri Public Service Commission l
3 P.O.
Box 360 i
Jefferson City, MO 65102 1
U.S.
Nuclear Regulatory Commission i
ATTN Document Control Desk
)
Washington, D.C.
20555 i
t i
J l
i i
4 i
1 i
4 Attcchment 1 to ULNRC-1811 Page 1 of 4 l
j Direct Suppliers of Safety-Related Fasteners 3
i f
A & G Engineering Co.
Crosby Valve & Gage 4640 E. La Palma Ave.
43 Kendrick St.
I Anaheim, CA 92807 Wrentham, MA 02093 I
I t
i ANCO Engineers. Inc.
Donley Geigher. Inc.
l 9937 Jefferson Blvd.
P.O. Box $515 i
Culver City CA 902323591 3401 North Broadway I
l 213-204-5050 St. Louir MO 63147 B D R Engineering. Corp.
Dresser Industries. Inc.
l i
l 1307 N. Seventh St.
Industrial Valve l
Columbia. MO 65201 P.O. Box 1430 l
Alexandria. LA 71301 2
318-640-2250 Brusco-Rich Inc.
l 213 chesterfield i
Industrial Blvd.
Farwell & Hendricks. Inc.
i Chesterfield, MO 63017 1000 Ford Circle
]
Suite C Milford. OH 45150 l
Cariinal Industrial Products. Inc.
l 3873 West Oquendo Rd.
I Las Vegas, NV 89118 International Inc.
Don H. Munger & Co.
1150 Hanley Ind. Ct.
Colt Industries St. Louis, MO 63144 i
Tairbanks Horse Engine Div.
314-961-8100 701 Lawton Ave.
I l
Beloit. WI 53511 i
j Flygt Corporation Van Devanter Engineering Co. Inc.
I 4
l Consip. Inc.
1617 Manufacturers Dr.
Customiine Division Tenton, MO 63025
[
1418 E. Linden Ave.
314-343-8880 Linden. NJ 07036 b
1 Foxboro Co.
{
Crane Company 38 Neponset Aven.
f 3:41 Industrial Dr.
Foxboro MA 02035 Signal Hill, CA 90806 l
4 1
General Electric Co.
I Crane Company 1015 Locust St.
Industrial Prod. Group St. Louis, MO 63101 i
Valve Serv. & Repair Div.
I i
1120 Ohioview Ave.
l Ambridge. PA 15003 General Electric Co.
I Mobile Co=: unications 744 Office Parkway St. Louis, MO 63141 i
j l
i
i Attachrent 1 I
l Gimpel Corporation Ingersoll Ra,d Company
[
250 N. Woodbourne Road Parts Order Entry i
P.O. Box 188 125 Tubeway Langhorne PA 19047018 Carol Stream. IL 60188 i
821-575-7514 Inventory Sales Graybar Electric Co.
3140 Park Ave.
1 P.O. Box 1467 St. Louis, MO 63104 r
{
2708 Industrial Dr.
f l
Jefferson City, MO 65102 Limitorque Corporation l
5114 Woodall Road i
j Graybar Electric Co. Inc.
Lynchburg, VA 24506 l
l P.O. Box 376 I
Main Post Office l
dt. Louis, MO 63166 J E Lonergan Co.
j 10050 Sandmeyer Lane j
2 Philadelphia, PA 19116 i
Grinnell Corp.
L 155 Weste.inster St.
f j
Providence, RI 02903 Lone Star Screw Company
[
5826 Armour Drive i
P.O. Box 15211 l
Grinnell Corp.
Houston TX 77020 L
I 1615 S. Kingshighway l
l St. Louis, MO 63110
[
1 Masoneilan i
A. D. Mid.'1 Co.
I I
Melville B Hall. Inc.
2505 Metro 21*.d.
1 3001 Spruce Street Suite C l
St. Louis MO 63103 Maryland Heights, MO 63043 j
314-567-5670 i
t Hammel Dahl & Jamesbury j
Controls Co.
McMaster-Carr Supply Co.
1 175 Post Rd.
P.O. Box 4355 i
1 Warwick. RI 02888 Chicago, IL 60680 l
i House of Tool & Er.gineering Inc.
Mosler Inc.
436 Anglum Rd.
445 Sovereign Ct.
]
Hazelwood, MO 63042 Manchester, MO 63011 1
ITT Barton Don H. Muager & Co. Inc.
i C. M. Tilley Co. Inc.
1150 Hanley Ind. Ct.
l 742 Goddard Ave.
St. Louis. MO 63144 Chesterfield, MO 63017 i
314-537-2800 d
1 i
Ingersoll Rand Company l
P.O. Box 1916 Piscataway NJ 09854 i
1.
i
I At tcchant 1
[
l I
l i
National Auto Supply Co.
1120 H. L. King Dr.
Carl F. Cast Co.
[
]
E. St. Louis IL 62201 930 N. McNight Rd.
St. Louis, MO 63132 l
I 314-993-2870 1
National Elec. Serv. Co.
j 321 Lombard Street Ru'nimann-Lucas Inc.
St. Louis, MO 63102 10800 Midwest Ind. Blvd.
{
St. Louis, MO 63132 l
O'Brien Equipment Co.
l 1919 Hampton Avo.
St. Louis Valve & Fitting Co.
)
St. Louis, MO 63139 P.O. Box AB i
j Fenton, NO 63026
[
t Pacific Pumps I
Dresser Industries Inc.
Service Supply Co.
t 3201 Volf Road 3715 Pennridge Dr.
i Franklin Park, IL 60131 Bridgeton, MO 63044 l
t i
)
Pacific Scientific Shipping Utilities Inc.
i 1346 So. State College Blvd.
10519 Liberty Ave.
l Anaheim, CA 92803 St. Louis, MO 63132
[
i Paul Munroe SLIGO. Inc.
Enertech P.O. Box 171 2950 Birch St. Louis, MO 63166 i
Brea CA 92621 3
l Special T Metals Co. Inc.
i i
Pereutit Company 8425 Mid County Ind. Dr.
)
P.O. Box 355 St. Louis, MO 63114
[
j E 49 Midisnd Ave.
j Paramus, NJ 07652 Target Rock Corp.
j 1
P.O. Box V 1966E Broad Hollow Rd.
Phillips Drill Company East Pariningdale, NY 11735 231 Blaine Avenue Michigan City, IN 46360 l
l tiemann Ind. Howe l
l Process Chemical Equip. Co.
P.O. Box 14406 l
P.O. Box 132s St. Louis, MO 63178 l
42-A Worthington Dr.
}
Maryland Heights, MO 63043
)
I i
R E C Corporation Ten Beach St.
]
Mt. Vernon, NY 10550 I
J i
3 4
l Attcchtent 1 i
I Union Pump Compay 4600 West Dickmann Rd.
i Battle Creek, MI 49015109
[
l Unistrut Service Co.
i 2722 Mercantile Dr.
l St. Louis, MO 63144 Valcor Engineering Corp.
2 Lawrence Road Springfield. NJ 07081 v
i Velan Valve Corp.
1 2125 Ward Avenue
[
Montreal, Quebec Canada H4M IT6 I
I i
Vincent Metals l
2150 S. 59th St.
St. Louis, MO 63110 l
Waterman & Waterman
[
Creve Coeur Executive j
Office Park 745 Craig Rd. Suite 300 St. Louis, MO 63141 l
l i
WESCO 2820 Market St.
St. Louis, MO 63103 Westinghouse Electric Corp.
t P.O. Box 28540 1
2060 Craigshire Rd.
St. Louis. MO 63146 i
Yarway Corporation j
Blue Bell. PA 19422 i
Zurn Industries A. L. McMin & Co. Inc.
P.O. Box 1467 i
Belleville. IL 62223 618-569-7075 j
e l
i
)
j Atlas Industrial Soap Bottis Corporation u
f I
2930 Market 18703 GH - Circle Drive l
St. Louis, MO 63103 P.O. Box 508 j
314-241-6363 Waller. TX 77484 713-463-5100 1
I
{
i Atwood & Morrill l
285 Canal Street Borg Warner l
Salem. MA 01970 5005 Interstate Drive N 617-744-5690 Mornan. OK 73069 l
405-364-4040 t
I j
Atwood & Morrill Co.
t j
Rhodes Equipment Co.
Borg Warner Air Cond. Inc.
[
1 8704 Manchester Road P.O. Box 2069 i
St. Louis, MO 63144 Columbia MD 20045-1069 j
314-962-8820 l
Borg Warner Air Cond. Inc.
l 1
ITT Barton 11645 N0rthline Ind.
}
Industrial Sales Maryland Heights HO 63043 i
349 W. 195th Street 314-567-5684 i
)
Glenvood. IL 60425 i
312-756-1472 f
Borg Warner l
i P.O. Bcx 2185 i
ITT Barton van Nuys CA 91409
)
C M Tilley Co., Inc.
818-781-4000 1
742 Goddard Avenue i
Chesterfield, MO 63017 1
314-537-2800 Borg Warner Industrial Products. Inc.
j 6475 Joliet Rd.
Larange. IL 60525
]
ITT Barton Instruments 618-465-5005 P.O. f:ox lid 2 i
900 S. **:n. bull Canyon J
City of Industry. CA 91749 Borg Warner i
3 818-961-2547 Mechanical Seal Div.
I 6001 Vollmer Ln.
I Godfrey. IL 62035 i
Bechtel Pet e: Corp.
618-466-3007 I
(
15740 Shady Grove Road i
j Gaithersburg. MD 20760 301-258-3000 Borg Warner Industrial Byron Jackson Products l
4 1
Bergen Paterson Nuclear Valve Group i
1 Pipe Support 2300 East Vernon c/o The Hesler Co.
Vernon. CA 90058-0017 l
P.O. Box 2807 213-587-6171 Prairie Village. KS 66208 314-454-0215 1
Cardinal Industrial, Products. Inc.
l 3873 West Oquendo Road Las Vegas. NY 69118 l
1 702-739-1966 i.
- - _ _. ~ -
. ~
l Attachasnt 2 l
l f
1 i
Cardinal Industrial Ser.
Cooper Electric Sales. Inc.
100 Sun Valley Circle 70 D Grasso Plaza 4
i Fenton, MO 63026 P.O. Box 6927 l
l 314-349-1599 St. Louis, MO 63123 l
]
314-638-3434
[
t Cleco Industrial i
Fastener Co.
Cooper Industries l
i 16701 Lathrop Avenue Energy Services Group i
I Harvey. IL 60426 West Chestnut Street 312-339-3600 Mt. Vernon OH 43050 1
614-393-8200 l
l Colt Industries
[
]
Fairbanks Horse Engine Div.
Cooperheat Inc, j
l 701 Lawton Avenue Chicage District Beloit WI 53511 10010 N. Express Drive j
608-364-4411 Highland, IN 46322 l
I l
800-435-9455 C M Tilley Co., Inc.
f 742 Coddard Avenue Corley Hfg. Co.
j chesterfield, MO 63017 6555 Hunnicut Road i
314-537-2800 Dallas, TX 75227 l
4 214-388-7437 I
I Combustion Engineering 6362 College Blvd.
Corner & Lada Co., Inc.
overland KS 66211 1341 Elmwood Avenue 913-491-6511 Cranston, RI 02910 401-785-8000 i
Consip Inc.
Customline Division Crane Co.
j 1418 E. Linden Ave.
Valve Serv. & Repair Div, l
4 Linden, NJ 07036 12 East Devonwood j
201-486-1272 Romeov111e, IL 60441 i
Consip Inc.
Crane Company i
Delphi Systems Div.
3241 Industrial Drive
]
3030 Red Hat Lane Signal Hill, CA 90806 Whittier, CA 90601 213-498-3321 l
l 213-692-9021 j
Crane Company Cooper Turner Industrial Prod Group Keystone Ind. Park Valve Service & Repair Div.
200 Rittenhouse Circle 1120 Ohio View Ave.
3 I
E Bldg. 8 Ambridge, PA 15003
{
3ristol, PA 19007 412-266-8350 l
}
4 d i'
j l
l
)
l
)
I Crane Company Anchor Darling Valve Company l
Valve Service i Repair Div.
P.O. Boa 3428 i
3602 W. 12th 701 First Street l
Houston. TX 77008 Williamsport. PA 17701-0428 I
3 713-862-8821 717-327-4800 Crane Company Daniel International Corp.
f Cheepump Division P.O. Box 146 i
175 Titus Avenue Strawn. KS 66839 Warrington. PA 18976 l
215-343-6000
(
Donley Geigher. Inc.
P.O. Box 5515 l
4 Crane Company 3401 North Broadway I
Midwest Machinery Company St. Louis HO 63147 413 Hanley Ind. Ct.
314-421-1758 St. Louis MO 63144 l
}
314-647-3250 l
Door Service. Inc.
I 11159 Suite E Crane Company South Town Square Valve Service Div.
St. Louis, MO 63123 203 Hampshire Street 314-487-0800 Indian Orchard. MA 01151 i
413-543-3331 Dragon Valves. Inc.
P.O. Box 489 Crane Conrany Norwalk. CA 90650 3241 Industrial Drive 213-921-6605 Signalmill. CA 90806 213 '.98-3321 Dresser Industries. !ac.
Construction Equipment l
Crane Company 755 S. Milwaukee Asenue Clynes-Theismann. Inc.
Libertyville. IL 60048 i
]
11858 Dorsett 312-?67-2829 Maryland Heights. M0 63043 314-298-8544 Masovellan Div.
Dresser Industries. Inc.
Crosby Valve and Cage Central Controls Co., Inc.
l 43 Kendrick Street 11723 Northline Ind.
j Wrenthan. MA 02093 P.O. Box 24 q
617-384-3121 Maryland Heights. HO 63043 314-991-1440 j
4 I
Crosby Valve and Cage
)
Randon Company Dresser Industries 1027 So. Vandoventer Carlton Company St. Louis, MO 63110 9291 Watson Road 314-652-5950 St. Louis, MO 63126
)
314-968-3850 1
i j,
lE
_. =. - -
l Dresser Industriee Elkhart Brass Mfg. Co.
k Heise Plant Department TR j
j P.O. Box 515 P.O. Box 1127
{
153 So. Main Street Elkhart. IN 46515 i
Newtown CT 06470 219-295-8330 203-426-3115 l
I Fisher Controls International. Inc.
f Dresser Industries Don H. Munser & Co., Inc.
Dresser Instruments Div.
1150 Hanley Ind. Ct.
l 250 E. Main Street St. Louis MO 63144 Stratford, CT 06497 314-961-8100 203-378-8281 1
Toxboro Co.
[
Dresser Mfg.
1901 S. Busse Rd.
1 41 Tisher Avenue Mt. Prospect. IL 60056 Bradford. PA 16701 617-549-5225 814-368-3131 4
Toxboro Co.
Dresser Mfg. Division Attnt Dept. 747 Dresser Ind. Inc.
600 North Bedford St.
3205 North Wolf Road East Bridgewater. MA 02333 4
P.O. Box 336 617-549-5225 i
I Franklin Park. IL 60131 l
312-451-3965 l
1 Toxboro Co.
i Analytical Div.
Dresser Industries. Inc.
P.O. Box 5449 Industrial Valve 151 Woodward Ave.
P.O. Box 1430 South Norwalk CT 06856-5449 Alexandria. LA 71301 203-853-1616 318-6'0-2250 Foxboro Co.
I Dresser Industries. Inc.
11715 Administration Dr.
Jeffrey Mig. Division Suite 102 P.O. Box 387 St. Louis. NO 63146 Woodruff. SC 29388 314-567-4377 803-476-7523 l
Toxboro Co.
Dresser Rand 38 Neponset Avenue l
39 Worthirston Drive Toxboro. MA 02035 j
Naryland Heights. MO 63043 800-343-1198 l
Pacific Pumps Foxboro Co.
i Dresser Industries. Inc.
Armstrong Rd.
i 3201 Wolf Road Plynouth Ind. Pk.
Tranklin Park. IL 60131 Plynouth MA 02360 I
312-455-8210 617-747-1100
, 1 4 -
J
. - - =.- - _
l Attachasnt 2 d
l Toxboro Company General Electric Company Analytical Div.
Install & Serv. Eng. Div.
140 Water Street 1015 Locust Street l
P.O. Box 5449 St. Louis, MO 63101 l
So. Norwalk. GT 06856-5449 314-342-7741 203-853-1616
(
i General Electric Company General Eastern Railroad Parts Center l
Instruments Corp.
230! South 3rd Street 50 Hunt St.
St. Louis, MO 63104 t
Waterton, MA 02172 314-342-7849 800-225-3208 l
General Electric Company l
l General Eastern Instrumentation and Computer d
i Instruments Corp.
Sales & Service Adelphi. Inc.
1353 North Warson Road 12015 Manchester St. Louis. MO 63132 St. Louis, MO 63131 314 993 0537
)
314-821-1232 i
General Electric Company i
General Electric Apparatus Service l'
National Supply Sales 1115 Tast Road 2825C Pacific Dr.
St. Louis, Mo 63110 t
Norcross. GA 30071 314-644-1990 800-437-2537 General Electric Company i
4 General Electric Apparatus & Engineering Services l
Electronics Park P.O. Box 10506A l
Building 6 Room 205 Atlanta. GA 30348 l
Syracuse Nf 13221 314 342-7701 1
l 315-456-2998 j
i l
l General Electric Company i
General Electric Apparatus & Engineering 175 Curtner Avenue 6157 South Cass Avenue San Jose, CA 95125 Darlen. IL 60559 408-925-7253 404-447-7241 l
i General Electric Company General Electric Company Service Shop Nuclear Plant Serv. Dept.
2455 Cassens Dr.
2311 W. 22nd Street Tenton No 63026 Suite 201 1
314-343-1777 Oakbrook. IL 60521 1
312-573-3929 General Electric Ccapany Service Center General Electric Coupany 2355 Naepton Avenue P.O. Box 44375 i
St. Louis, MO 63139 San Francisco. CA 94144 314-342-7884
- (
i i
i l
I General Electric Company General Electric Company Sales & Service Co.
Sales & Service Co.
l 1355 Watson Road North 1355 Warson Road North i
St-Louis MO 63132 St. Louis, MO 63132 l
31t-993-0537 314-993-9537 General Electric Company General Electric Rental Apparatus & Engineering Services General Electric Company l
1015 Locust St.
730 West 45th Avenue l
St. Louis, MO 63101 Suite B 314 342-7701 Munster. IN 46321 I
800-437-3687 l
I General Electric Company Sales & Service Co.
General Electric Supply Co.
1355 Warson Road North General Electric Company St. Louis. No 63132 1015 Locust Street 314-993-0537 St. Louis, MO 63101 i
314-342-7741 i
1 General Electric Company 1015 Locust Street GinPel Corporation St. Louis. Ho 63101 250 N Woodbourne Road i
314-342-7741 P.O. B3x 188 Langhorne. PA 19047-0188 215-757-7658 General Electric Company l
Mobile Communications 744 Office Parkway Gould. Inc.
St. Leuts. MO 63141 Computer Systems Div.
314 432-1336 P.O. Box 409148 j
6901 W. Sunrise Blvd.
Tt. Lauderdale. FL 33313-409148 Ceneral Electric Company 305-486-8606 730 West 45th Avenue Suite B Munster. IN 46321 Could. Inc.
800-437-3687 Computer Systens Div.
30 Gould Center Rol!!ng Meadows. IL 60008 General Electric Supply 1620 Headland Dr.
Tenton. M0 63026 Gould. Inc.
314-349-0600 Recording Systens Div.
244 Cross Keye Shopping Center T!orissant. 00 63033 General Electric Company 314-921-3444 Lamp Division 1530 Tairview St. Louis. MO 63132 Gould. Inc.
314-429-6930-Measurenent Systems Div.
File 9699 Los Angeles. CA 90074.
I l
Gould, Inc.
ITT Engineered Valves TMSD 33 Centerville Road 432 Windsor Park Dr.
P.O. Box 6164 Dayton, OH 45459 Lancaster, PA 17603-2064 314-921-3444 314-567-1220 Gould, Inc.
Harlo Corporation
]
Computer Systems Div.
Control Panel Div.
P.O. Box 9148 4210 Ferry St.
Ft. Lauderdale, FL 33310-9148 Grandville, MI 49418 305-587-2900 616-538-0550 Goulds Pumps, Inc.
18.arvey's Standard Service 1034 S. Brentwood Blvd.
1407 Avtaue H Suite 376 Ft. Hadison, IA 52627 St. Louis, MO 63117-1203 616-538-0550 314-862-7867 Hills-McCanna Co.
Graybar Electric Company Corva Corporation P.O. Box 1467 149 Weldon Parkway 2708 Industrial Drive Maryland Heights, MO 63043 Jefferson City, MO 65102 314-567-1220 314-636-5135 HUB, Inc.
Graybar Electric Co., Inc.
2146 Flinstone Dr.
P.O. Box 376 Tucker, GA 30084 Fbin Post Office 404-934-3101 St. Louis, MO 63166 314-531-0847 Ingersoll Rand Company Pump and Compression Service Div.
Grinnell Corp.
20602 E. 81st Street 155 Westminster St.
Broken Arrow, OK 74014 Providence, RI 02903 800-346-8100 401-831-7000 Ingersoll Rand Company Grinnell Corp.
P.O. Box 1916 1615 S. Kingshighway Piscataway, NJ 09854 St. Louis, MO 63110 201-981-9100 314-771-4925 Ingersoll Rand Company Grinnell Fire Protect Parts Order Entry Systems, Co., Inc.
125 Tubeway 1
8200 Exchange Way Carol Stream, IL 60188 Brentwood, MO 63144 800-526-3569 314-968-4950 l,
i
Attachmant 2
?
Ingersoll Rand Repair Center Marco Screw Products 1515 Page Ind. Blvd.
1978 Congressional Dr.
St. Louis, MO 63132 St.' Louis, MO 63141 314-427-2593 314-432-6505 J. E. Lonergan Company Maseneilan Dresser 10050 Sandmeyer Lane Dresser Valve and Controls Philadelphia, PA 19116 North American Oper.
215-677-1710 Dresser Industries 85 Bodwell St.
Avon, MA 02322 Combustion Engineering, Inc.
617-584-7478 Jamesbury Corporation 640 Lincoln Street P.O. Box 664 Masoneilan Worchester, MA 01613-0664 A D Michel Co.
617-852-0200 2505 Metro Blvd. Ste. C Maryland Heights, MO 63043 314-567-5670 John Crane Houdaille 9409 East 55th Place Tulsa, OK 74145 McMaster Carr Supply Co.
918-664-5156 P.O. Box 4355 Chicago, IL 60680 John Crane Houdaille, Inc.
6400 Oak Street Morton Grove, IL 60053 Mosler, Inc.
312-967-2400 1401 Wilson Blvd.
i Arlington, VA 22209 Leslie Company Engineered Process Equip. Inc.
Nash Engineering Company 11993 Borman Driva 97 Progress Parkway i
St. Louis, MO 63146 Maryland Heights, MO 63043 314-378-0850 314-878-8383 i
Limitorque Corporation NPS Industries, Inc.
8700 Monroevia 10420 Metric Blvd.
Suite 320 Austin, TX 78758-4999 Lenexa, KS 66215 512-836-4161 913-492-7800 Pacific Pumps Limitorque Corporation Dresser Industries, Inc.
5114 Woodall Road 3201 Wolf Road Lynchburg, VA 24506 Franklin Park, IL 60131 804-528-4400 312-455-8210 Pacific Scientific 1346 So. State College Blvd.
Anaheim, CA 92803 ;}4 774-5217
Attachmant 2 Pacific Scientific Phillips Aluminum Mfg.
Suite E Route 3, Box 9 555 To11 gate Memphis, MO 63555 Elgin, IL 60123 312-888-3600 Phillips Cable, Inc.
P.O. Box 12 Pacific Scientific Company Watertown, NY 13601 Belfab Division P.O. Box 9370 Daytona Beach, FL 32020 Phillips Drill Co.
904-253-0628 231 Blaine Ave.
Michigan City, IN 46360
.19-874-4217 Pall Trinity Micro Corp.
P.O. Box 2030 Cortland, NY 13045 Phillips Driscopipe Inc.
607-753-6041 P.O. Box 83-3866 Richardson, TX 75234 800-52'-0662 Paul Munroe Enertech 2950 Birch Phillips Welding & Machine Brea, CA 92621 1015 W. Liberty St.
714-528-0128 Mexico, MO 65265 Peerless Punp Company REC Corporation Ulmer Equipment Company Ten Beach Street 1554 Fenpark Drive Mt. Vernon, NY 10550 Fenton, MO 63026 914-699-6000 314-343-4606 Service Supply Co.
Peerless Mfg. Company 3715 Pennridge Drive Flo Con Bridgeton, MO 63044 321 Hanley Ind. Ct.
314-739-7769 St. Louis, MO 63144 314-645-1316 SLIGO Inc.
P.O. Box 171 Peerless Pump Company St. Louis, MO 63166 8050 Watson Road 314-231-3050 St. Louis, MO 63119 314-842-4424 1
Southern Bolt & Fastener Corp.
P.O. Box 7196 Perkins Constracting Shreveport, LA 71107 1901 Bender Lane 318-221-4251 Arnold, MO 63010 314-296-1100 -.
Attachmant 2 s
Spec-Tech Electric Co.
Tcledyne Firth Sterling Mocker & Assoc.
Building One 245 Old Mermac Sta. Rd.
470 Street Rund Road Manchester, MO 63021 Pittsburgh, PA 15236 314-227-4777 412-464-5200 Target Rock Corp.
Teledyne Landis Machine Co.
P.O. Box V 5th & Church St.
1966E Broad Hollow Road Waynesboro, PA 17268 East Farmingdale, NY 11735 717-762-3151 516-293-3800 Teledyne Penn Union Taledyne Analytical Electric R L Weisheimer & Assoc.
Re Kennedy Co., Inc.
132 S. Rapp 225 Old Meramec Sta. Rd.
P.O. Box 127 Manchester,!!0 63011 Columbia, IL 62236 314-391-8840 Teledyne Teledyne Penn Union Hastings Raydist Electric Adelphi Inc.
Re Kennedy Co., Inc.
12015 Manchester 225 Old Meramec Sta. Rd.
St. Louis, MO 63131 Manchester, MO 63011 314-821-1232 Teledyne Republic Mfg.
Teledyne Analytical 15657 Brookpark Road Instruments Clevelend, OH 44142 Adelphi Inc.
216-267-2700 12015 Manchester St. Louis, MO 63131 314-821-1232 Terry Corp Dresser Rand Co.
I.
Steam Turbine Motor &
Teledyne Crittenden Generator Division Transformer Company 37 Coats St.
711 West Knox Street Wellsville. NY 14895 Gardena, CA 90248 716-593-1234 213-321-4355 Test & Heasureuent Teledyne Engineerir.g ' services 3M 130 Se:ond Avenue Dynatel Systems Div.
Waltham, MA 02254 P.O. Box 2963 617-890-3350 Austin, TX 78769 800-426-8688 Teledyne Farris Engineering Don H. Munger i Co., Inc.
1150 Hanley Ind. Ct.
St. Louis, MO 63144 314-961-8100 11
o Attachmsnt 2 b
Test & Measursment Velan Valve Corp.
Systems 3M Griswold Industrial Park P.O. Box 510 Williston, VT 05495 I
St. Louis, MO 63166 Viking Fire Protection Company 3M 499 Northgate Test & M:asurement Systems E,eeling, IL 60090 1941 Las Plumas Ave.
312-459-6800 San Jose, CA 95133 i
408-926-3535 Viking Steel & Aluminum i
1111 Chase Avenue l
Texas Bolt Company Elk Grove, IL 60007 P.O. Box 1211 800-323-8892
)
Heuston, TX 77001 713-869-7111 Walworth Corp.
P.O. Box 873 Union Pump Valley Forge, PA 19481 55 West 22nd St.
800-523-0260 Suite 302 i
Lombard, IL 60148 312-932-7227 Westinghouse Engineering Services 2060 Craigshire Road Union Pump Co.
St. Louis, MO 63146 4600 West Dickmann Road 314-776-2344 Battle Creek, MI 49015-1098 616-966-4600 Westinghouse s'gineering Services Unistrut Midwest 2060 Craigshire Road 1545 Atlantic St.
St. Louis, MO 63146 North Kansas City, MO 64116 314-776-2344 816-842-2043 Westinghouse Air Brake Company Unistrut Service Co.
500 Northwest Plaza 2722 Mercantile Drive St. Ann, MO 63074 St. Louis, MO 63144 i
314-647-4344 Westinghouse Electric Corp.
Sturtevant Division P.O. Box 28540 Valcor Engineering Corp.
2060 Craigshire Road 2 Lawrence Road St. Louis, MO 63146 Springfield, NJ 07081 314-85!-9534 201-467-8400 Velan Valve Corp.
2125 Ward Avenue Montreal Quebec, Canada H4M IT6 514-748-7743
'l s
Westinghouse Electric Corporation Westinghouse Electric Corporation Industry Electronic Division Instrument Service i
P.O. Box 2958 18418 S. Wentworth Shawnee Mission, KS 66201 Lansing, IL 60438 i
913-451-6544 312-895-4111 i
i Westinghouse Electric Corporation Westinghouse Electric Corporation d
Combustion Control Div.
1905 Bernics Road l
1201 North Main Street Lansing, MI,60438 1
P.O. Box 901 312-454-7125 4
Orrville, OH 44667
)
216-682-9010 i
Westinghouse Hittean Nuclear Incorporated Westinghouse NSID 1256 N. Church St.
5 Spartanburg Service Ctr.
Moorestown, NJ 08057 P.O. Box 2110 609-722-5700 i
Spartanburg, SC 29304 803-599-0110 Westinghouse Engineering Services Westinghouse Electric 2060 Craigshire Road Instrument Service Company St. Louis, MO 63146 750 Trumbull Drive 314-776-2344 a
Pittsburgh, PA 15205-4399 t
412-276-0650 j
Yarway Corporation Blue Bell, PA 19422 1
1l Westinghouse Electric Corporation 215-825-2100 Productos Westinghouse Inc.
i GPO Box 71455 San Juan, Puerto Rico 00936 Zurn Industries i
Mechanical Drives Div.
1801 Pittsburgh Ave.
Westinghouse Electric Corporation Erie, PA 16512 i
Elevator Division 814-455-0921 9475 Dielman Rock Island Drive l
l.
St. Louis, MO 63132 I
314-991-5232 Zurn Industries A L Martin & Co. Inc.
l P.O. Fox 1467 I
Westinghouse Electric Corporation Belleville, IL 62223 i
P.O. Box 28540 314-569-1075 l
2060 Craigshire Road l
St. Louis, MO 63146 i
412-851-9534 Zurn Industries. Inc.
Marland Clutch Div.
l P.O. Box 308 l
Westinghouse Electric Larange IL 60525 j
Semiconductor Division 312-352-3330 t
Youngwood, PA 15697 l
412-925-7272 13 -
to ULNRC-1811 Indirect Suppliers of Safety-related Fasteners Anelor Darling Valve Company Ametek, Inc, P.O. Box 3428 Thermox Division 701 Jirst Street 150 Freeport Reid i
W111Camsport, PA 17701-0428 Pittsburgh, PA t5238 717-327-4805 412-828-9040 l
A & G Engineering Company Ametek, Inc.
4640 It. LaPalma Avenue Thermox Div.
Anaheim, CA 92807 David Sales Company i
800-242-6587 12015 Manchester St. Louis, MO 63131 j
A D Michel Co.
2505 hetro Blvd. Ste. C Ametek, Inc.
Maryland Heights, MO 63043 S & K Division 314-567-5670 Hagedorn and Cannon Co., Inc.
l 456A Sovereign Ct.
Manchester, MO 63011 Aeroquip Corporation 314-227-6800 Tomkins Johnson Div.
Lucas Fluid Power Inc.
l Moehlenpah Engr. Div.
Ametek, Inc.
11999 Borman Panalarm Division St. Louis, MO 63146 Carl F. Gast Company 314-469-9100 930 N. McKnight Road St. Louis, MO 63132 314-993-2870 Ametek
}
S & K Division 2233 State Road Ametek, Inc.
Ben Salem, PA 19020 Controls Division 215-639-0900 R A Behrmann & Assoc.
4173 Hoffmeister Avenue St. Louis, MO 63125 Ametek 314-631-4400 l
Southern Cross Corporation l
P.O. Box 2168 l
Norcross, CA 30091-2168 Amstek, Inc.
I 800-241-5057 Combustion Kinetics 10420 Old Olive St. Road l
St. Louis, MO 63141 Ametek Inc.
314-997-7395 1hermox Div.
150 Freeport Road Pittsburgh, PA 15238 Ametek Power Instrument Division l
412-828-9040 7352 N. Lawn Dale Skokie, IL 60076
]
800-323-0764 Ametek P.O. Box 1047 I
$02 Indiana Applied Engineering Company Sheboygan, WI 53082 P.O. Box 1327 414-457-9435 Orangeburg, SC 29116-1327 1
)
Attachmsnt 3 to ULNRC-1811 Page 1 of 17 Direct Suppliers of Non-Safety-Related Fasteners A C Compressor Corp.
Allis Chalmers 600 Enterprise Drive Environmental 6 Energy Suite 105 Systems, Inc.
Oak Brook, IL G 2.%21 546 McBride Point Dr.
Ballwin MO 63011 314 256-6800 A & G Engineering La.
4640 E. La Palma Ave.
Anaheim, CA 92807 A C Valve, Inc.
P.O. Box M93 York, PA 17405 R. P. Adams Company, Inc.
Carl F. Gast Co.
930 N. McNight Rd.
Allis Chalmers Corp.
St. Louis, MO 63132 10965 Granado Lane 314-993-2870 Felte 200 Gverland Park, KS 66211 Air Hydraulics Co.
6074 Baumgartner Ind. Dr.
Altec Industries, Inc.
St. Louis, MO 63129 2106 South Riverside Rd.
St. Joseph, MO 64503 Air Products & Chemical Incorporated American Bristol Allenton, PA 18195 Industries, Inc.
1600 W. 240th St.
Harbor City, CA 90710 Air Specialists, Inc.
10647 Liberty Ave.
St. Louis, MO 63132 Alcoa Aluminum Co.
American Foundry & Mfg.
8301 Maryland Ave.
P.O. Box 5544 St. Louis, MO 63105 St. Louis, MO 63147 Allen Sherman Hoff Co.
American Iron-Steel Mfg.
c/o Rhodes Equipment Co.
5601 Manchester Ave.
1401 South Brentwood St. Louis, MO 63110 St. Louis, MO 63144 Allied Const. Equip. Co.
4015 Forest Park Blvd.
St. Louis, MO 63108
Attachmsnt 3 i
American Meter Co.
Bailey Controls Co.
2801 S. Fairfield A. D. Michael Co.
Suite E 2505 Metro Blvd. Suite C Lombard, IL 60148 Maryland Heights, M0 63043 314-567-5670 American Standard Ind.
Industrial Prod. Div.
Bailey Controls Co.
10100 Santa Fe 12963 Maurer Ind. Dr.
Overland Park, KS 66212 St. Louis, MO 63127 ANCO Engineers, Inc.
Barrett Electrical Supply Co.
9937 Jefferson Blvd.
45 Worthington Drive Culver City, CA 902323591 Maryland Heights, MO 63043 213-204-5050 Beavco Inc.
ARMCO Incorporated P.O. Box 95 Construction Prod. Div.
Somers Point, NJ 08244 10877 Watson Rd.
609-653-1012 Suite 203 St. Louis, MO 63122 Bethlehem Steel Corp.
7701 Forsyth Blvd.
Atlas Copco Inc.
St. Louis, MO 63105 4255 Parker Rd.
Florissant, MO 63033 314-839-4142 Bi-State Machinery Co.
4303 Bistate Ind. Dr.
St. Louis, MO 63128 Authecized Motor Parts Corp.
Nappa Auto Parts 525 S. Jefferron Ave.
Bi-State Fastenar Co.
St. Louis, MO 63103 8595 St. Charles Rock Rd.
St. Louis, MO 63114 Automatic Sprinkler 2445 Rock Island Blvd.
Blackwell Ind. Sales thryland Heights, MO 63043 1003 Ormond Drive Kirkwood, MO 63122 B B C Brown Boveri, Inc.
11715 Administration Dr.
Blalock Power Products St. Louis, MO 63141 6572 I-85 Court Norcross, CA 30093 B D R Engineering, Corp.
1307 N. Seventh St.
Blaw Knox Equipment Columbia, MO 65201 P.O. Box 1140 St. Charles, MO 63301 The Babcock & Wilcox Co.
13600 Wyandotie Street Bolt Industries Kansas City, M0 64145 P.O. Box 4968 Ocala, FL 32678.
Attachmant 3 Borg Warner Budget Buddy Co.
P.O. Box 2185 Div. of CANDO Inc.
Van Nuys, Cl 91409 1141 Orchard Road P.O. Box 9809 Kansas City, MO 64134 BW/IP International Inc.
Butler Supply Inc.
Byron Jackson Products 5715 Elizabeth Ave.
695 Church St.
St. Louis, MO 63110 Interstate 90 & Rte. 21 Elgin, IL 60123 Cardinal Industrial Products Inc.
Borg Warner Industrial 3873 West Oquendo Rd.
Producte Inc.
Las Vegas, NV 89118 6475 Joliet Rd.
LaGrange, IL 60525 Carr Lane Manufacturing Co.
4200 Carr Lane Court Borg Warner P.O. Box 13149 Mechanical Seal Div.
St. Louis, M0 63119 6001 Vollmer Ln.
Godfrey, IL 62035 Case Power & Equip.
2300 Cassens Rd.
Branson Indus Products Fenton, MO 63026 2363 59th St.
St. Louis, MO 63110 The CECO Corp.
12073 Mereview Braun Automotive Inc.
St. Louis, MO 63146 720 King Drive E. St. Louis, IL 62201 Central Controls Co. Inc.
11723 Northline Ind.
Brooks Hardware & Security P.O. Box 24 245 M111well Dr.
Maryland Heights, MO 63043 Maryland Heights, M0 63043 Bruening Bearings Inc.
P.O. Box 1011 Jefferson City, MO 65102 l
Bruening Bearings Inc.
2727 Washington Ave.
St. Louis, MO 63103 Brusco-Rich Inc.
A B Chance Co.
213 Chesterfield 210 North Allen Street Industrial Blvd.
Centralia, MO 65240 Chesterfield, MO 63017 i
f 1
Attachmsnt 3 Chelsea Industries Combustion Engineering, Inc.
2555 Metro Blvd.
P.O. Box 910047 Maryland Heights, MO 63043 Dallas, TX 75391 Chemical Piping Sys. Inc.
Combustion Engineering 10836 Galt Ind. Dr.
4400 College Blvd.
St. Louis, ho 63132 Suite 100 Overland Park, KS 66211 Chicago Heater Co. Inc.
1900T Johnson Drive Commercial Auto Mission Woods, KS 66205 Electric Co.
2301 Olive St.
St. Louis, MO 63103 Chicago Pneumatic Tool 2200 Bleecker St.
Utica, NY 13501 Comparts Inc.
16550 Racho Road P.O. Box 788 Clark Reliance Corp.
Taylor, MI 48180 Rhodes Equipment Co.
8704 Manchester Rd.
St. Louis, MO 63144 Complete Reading Elec.
314-962-8820 58-C Weldon Parkway Maryland Heights, Ho 63043 Claypool Pump & Mach, Co.
2615 So. Tenth St.
Compressor Eng. Co.
St. Louis, MO 63118 5440 Alder Houston, TX 77081 Clynes-Theismann, Inc.
11858 Dorsett Compton Electric & Machinery Co.
Maryland Heights, MO 63043 1525 N. Broadway St. Louis, MO 63102 Colcord Wright Machinery and Supply Co.
Comsip Inc.
1632 Headland Dr.
Custom 11ne Division P.O. 2ox 8033 1418 E. Linden Ave.
Fenton, MO 63026124 Linden NJ 07036 831-343-3700 Control Components 22591 Avenidi Empressa Rancho Santa Margarita, CA 92688 Contractors Supply Co.
620 East 18th St.
Combustion Engineering Kansas City, MO 64108 Air Preheater Company 850 Warrenville Road Suite 302 Conveyor & Drive Equipment Co.
Lisle, IL 60532 P.O. Box 10740 St. Louis, Mo 63129 Attachsent 3 Cope Plastics, Inc.
6340 Knox Industrial Dr.
St. Louis, MO 63139 Copes-Vulcan. Inc.
Crosby Valve & Gage Hesler Company Randon Co.
P.O. Box 8207 1027 So. Vandeventer Prairie Village, KS 66208 St. Louis, MO 314-454-0215 314-652-5950 Corva Corp.
Cuppies Products Div.
149 Weldon Parkway H. H. Robertson Co.
Maryland Heights, MO 63043 2650 S. Hanley Rd.
St. Louis, MO 63144 J.P.B. Interprises Courier Industries G. W. Dahl Company, Inc.
P.O. Box 7389 Val-Quip Co. Inc.
St. Louis, MO 63177 P.O. Box 10970A 314-533-5700 St. Louis, MO 63135 314-524-3300 Crane Company 3241 Industrial Dr.
Paul Demay & Associates Signal Hill, CA 90806 17536 Chesterfield Airport Road Chesterfield, M0 63017 Crane Company Industrial Prod Group Valve Serv & Repair Div.
Diamond Power Specialty 1120 Ohioview Ave.
4640 Western Ave.
Ambridge, PA 15003 Lisle, IL 60532 1
Crane Co. - Valve Serv.
H. M. Dinzler Equipment Co.
& Repair Div.
1320 S. Vandeventer 3602 W.
12th St. Louis, MO 63110 Hoeston, TX 77008 Ditch Witch Sales Crane Company 107 Troy Rd.
Chicago Heater Div.
Collinsville, IL 62234 P.O. Box 191 King of Prussia, PA 19406 Dixie Electrical Mfg. Co.
Ken Way Co.
Crescent Parts & Equip. Co. Inc.
Suite A 2100 South 59th Street 8 The Pines Ct.
St. Louis, MO 63110 St. Louis, MO 63141 314-469-9998 Crest Mid West Inc.
10888 Indian Head Industrial Blvd.
St. Louis, MO 63132 -
Attachmsnt 3 j
Donley Geigher, Inc.
East Alton Supply Co.
P.O. Box 5515 328 Shamrock Rd.
3401 North Broadway East Alton, IL 62024 St. Louis, MO 63147 Electro Mative Div.
Donovan Industrial Supply Corp.
General Motors Corp.
917 Hodiamont Ave.
130 Brook Hollow St. Louis, M0 63112 Harrahan, LA 70123 Draco Mechanical Supply, Inc.
Elek Tek, Inc.
F.0. Box 20054 6557 N. Lincoln Ave.
8029 Litzsinger Rd.
Chicago, IL 60645 St. Louis, MO 63144 Dresser Mft. Division Energy Products, Inc.
Dresser Ind. Inc.
Electrorep Inc.
3205 North Wolf Road 83 Waldon Parkuay P.O. Box 336 Maryland Heights, MO 63043 Franklin Park, IL 60131 314-991-2600 Envirex, Inc.
Dresser Industries, Inc.
Pohlkotte Ressler Company Inc.
Industrial Valve P.O. Box 458 P.O. Box 1430 Ballwir, MO 630220458 Alexandria, LA 71301 314-391-8992 318-640-2250 F M C Corporation Dresser Pump Division 125 Windsor Dr.
Dresser Industries, Inc.
Suite 128 6901 W. 63rd Street Oak Brook, IL 60521 Overland Park, KS 66202 i
Pacific Pumps John Fabick Tractor Co.
Dresser Industries, Inc.
1 Fabick Dr.
3201 Wolf Rd.
Fenton, MO 63026 Franklin Park, IL 60131 312-455-8210 f
Farrar Pump 6 Machinery Dresser Rand 1701 S. Big Bend Blvd.
39 Worthington Drive St. Louis, MO 63117 Maryland Heighta, MO 63043 i
I - -
1 Attachm: int 3 e
Fischer Equipment Co.
Foster Wheeler Energy Corp.
2512 Sutton Ave.
Perryville Corporate Park St. Louis, MO 63143 Clinton, NJ 088094000 201-730-4000 Fischer & Porter Co.
P.O. Box 7777-W1170 Foxboro Co.
Philadelphia, PA 19175 38 Neponset Aven.
Foxboro, MA 02035 Fisher Controls International Inc.
France Compressor Don. H. Munger & Co. Inc.
Div. of Colt Ind.
I 1150 Hanley Ind. Ct.
450 St. John Rd.
St. Louis, MO 63144 Suite 494 314-961-8100 Michigan City, IN 46360 Fletcher Reinhardt Co.
Frankel Connector Co.
11440 Schenk Drive M.J. Associates, Inc.
Maryland Heights, MO 63043 3214 S. Big Bend Blvd.
St. Lcuis, h0 63143 314-645-2622 Florissant Dodge Sales Inc.
2175 No. Highway 67 r
Florissant, MO 63033 Gardner-Denver 140 Boulder Ind. Dr.
Bridgeton, MO 63044 Flygt Corporation Van Devanter Engineering Co. Inc.
1617 Manufacturers Dr.
Cateway City Intl., Inc.
Fenton, MO 63026 3701 Chouteau Ave.
314-343-8880 St. Louis, MO 63110 Flygt Corporation General Automotive l
Division of ITT Warehouses, Inc.
j 814 Fee Fee Road 2201 Washington Ave.
Maryland Hefghts, MO 63042 St. Lcuis, MO 63103 1
1 Forgy Gorman & Associates, Inc.
General Electric Co.
10200 Page Ind. Blvd.
1015 Locust St.
St. Louis, MO 63132 St. Louis, MO 63101 John Henry Foster Co.
General Electric Co.
10740 Midwest Ind. Blvd.
Mobile Communications i
St. Louis, MO 63132 744 Office Parkway St. Louis, MO 63141 1
Attachmsnt 3 General Electric Supply Graybar Electric Co. Inc.
1620 Headland Dr.
P.O. Box 376 Fenton, MO 63026 Main Post Office i
314-349-0600 St. Louis, MO 63166 General Kinematics Corp.
777 Lake Zurich Road Grinnell Corp.
Barrington, IL 60010 1615 S. Kingshighway St. Louis, MO 63110 Gieland Machine Shop 1621 Tower Grove Ave.
Grinnel Fire Protect St. Louis, MO 63110 Systems Co. Inc.
8200 Exchange Way Brentwood, MO 63144 Glasco Electric Co.
706 N. Jefferson Ave.
St. Louis, MO 63101 HJJ Company P.O. Box 905 Los Gatos, CA 95030 Glendale Chrysler Plymouth Inc.
10070 Manchester Rd.
Glendale, MO 63122 Hach Company P.O. Box 389 Loveland, CO 80539 Goedecke Wood & Co., Inc.
4101 Clayton Ave.
St. Louis. HD 63110 Melville B Hall Inc.
3001 Spruce Street St. Louis, MO 63103 Goulds Pumps, Inc.
1034 S. Brentwood Blvd.
Suite 376 Hammel Dahl & Jamesbury St. Louis, MO 63117120 Controls Co.
175 Post Rd.
Warwick, RI 02888 Graver Water Division Graver Co.
2720 US Highway 22 Union, NJ 07083 Hammond Distributing 119 Cass Ave.
St. Louis, MO 63102 l
i 1
Attachmsnt 3 4
Hayward Gordon Ltd.
I T T Engineered Valves 7485 Bath Road 33 Centerville Rd.
Malton-Mississauga P.O. Brx 6164 Ontario, Canada Lancaster, PA 17603206 471-729-1190 Hayward Tyler Inc.
P.O. Box 492 I B T Inc.
Burlington, VT 05402 1429 Hanley Ind. St.
St. Louis, MO 63144 Hewitt Robins Inc.
Robins Division Industrial Electric Supply &
P.O. Box 1481 Motor Repair Columbia, SC 29202 3326 E. Broadway Alton, IL 52002 Honeywell Inc.
Industrial Services Div.
Industrial Mine Sup. Co.
1100 Virginia Dr.
3605 Watson Rd.
Fort Washington, PA 19034 St. Louis, MO 63109 House of Tool & Engineering Inc.
Industrial Process Equipment Co.
436 Anglum Rd.
2800 Locust St.
Hazelwood, MO 63042 St. Louis, MO 63103 A K Howell Co. Inc.
Ingersoll Rand Company Equipment Co.
P.O. Box 1916 7603 Forsyth Blvd.
Piscataway, NJ 09854 St. Louis, M0 63105 Ingersoll Rand Company Hughes Brothers, Inc.
Parts Order Entry i
R. R. Kinyon Co.
125 Tubeway 9216 Clayton Rd.
Larol Stream IL 60188 St. Louis, MO 63124 314-993-4348
)
Ingersoll-Rand Repair Center 1515 Page Ind. Blvd.
St. Louis, MO 63132 I T T Engineered Valves Corva Corp.
149 Weldon Parkway Inventory Sales Maryland Heights, MO 63043 3140 Park Ave.
314-567-1220 St. Louis, MO 63104 1
1 l
2188 Welsch Ind. Ct.
j St. Louis, MO 63146429
)
.l a 4
Attachesnt 3 Joslyn Corp.
Kris Kor Tool Products P.O. Box 368 6414 Hampton Ave.
9200 W. Fullerton Ave.
Suite 7 Franklin Park, IL 60131 St. Louis, MO 63109 Joslyn Corp.
Kranz Automotive Body Company Jeslyn Hi Voltage 300 Russell Blvd.
Equipment Division St. Louis, MO 63104 4000 East 116th Street Cleveland, OH 44105 Laffey Equipment Co.
P.O. Box 16285 Joy Technologies Inc.
St. Louis, MO 63105 3101 Broadway Buffalo, NY 14225 Lane Machinery Co.
2424 Northline Ind. Blvd.
KAR Products, Inc.
Maryland Heights, MO 63043 461 N. Third Street P.O. Box 2414 Des Plaines. IL 60016 Lapham-Hickey Steel 500 S. Spring Ave.
P.O. Box 57 l
Kearney Division of St. Louis, MO 63166 Kearney National Inc.
Electrorep Inc.
83 Weldon Parkway Lapp Insulator Co.
Maryland Heights, MO 63043 Electrorep Inc.
314-991-2600 83 Weldon Parkway Maryland Heights, MO 63043 314-991-2600 Ken Way Co.
Suite A 8 The Pines Ct.
Lawrence Pumps Inc.
St. Louis, MO 63141 371 Market Street Lawrence, MA 01843 Key Equipment & Supply Co.
11432 Bowling Green Leeds & Northrup Instruments St. Louis, M0 63141 Corporate Hills #1 Suite 210 1655 Des Peres Rd.
Kickham Boiler & Engineering Inc.
St. Louis, MO 63131 625 E. Carrie Ave.
St. Louis, MO 63147 l
Liberty Machine Works. Inc.
2410 N. 9th St.
Kiefer Elect. Supply Co.
St. Louis, MO 63102 K.R. 3 Rend City Rd.
Benton, IL 62812 Limitorque Corporati;n 5114 Woodall Road R. R. Kinyon Co.
Lynchburg, VA 24506 9216 Clayton Rd.
j St. Louis, M0 63124 i
Attachmsnt 3 l
l Limitorque Corp.
Metal Goods 8700 Monrovia 8800 Pago Blvd.
Suite 320 St. Louis, MO 63114 Lenexa, KS 66215 Metro East Industrial Supply Inc.
J E Lonergan Co.
P.O. Box 578 10050 Sendmeyer Lane Hwy. 162 & State Aide 35 Philadelphia, PA 19116 Granite City, IL 62040 t
Lone Star Screw Company Meyer Industries 5826 Armour Drive P.O. Box 114 P.O. Box 15211 Red Wing, MN 55066 Houston, TX 77020 Mid-America Metals Inc.
Mark Controls Corp.
4199 Chippewa Pacific Valves St. Louis, MO 63116 3201 Walnut Long Beach, CA 90807 Mideo Sales & Service Masoneilan Dresser 11475 Page Service Dr.
Dresser Valve & Controls P.O. Box 28729 North American Oper.
St. Louis, MO 63146 Dresser Industries 85 Bodwell St.
Avon, MA 02322 Midway Wheel & Equipment 617-586-4600 2810 Washington Ave.
St. Louis, MO 63103 Masone11an A. D. Michel Co.
Midwest Tool & Supply Co.
i 2505 Metro Blvd.
81 Weldon Parkway Suite C Maryland Heights, MO 63043 Maryland Heights, MO 63043 314-567-5670 Milbradt Lawn Equipment Co.
11700 Olive Street Rd.
McGraw Edison Company St. Louis, MO 63141 Power Systems Division P.O. Box 1187 Shawnee Mission, KS 66222 Milford Supply 10943 Lin Valle St. Louis, MO 63123 McMaster-Carr Supply Co.
P.O. Box 4355 Chicago, IL 60680 Mine Safety Appl. Co.
2053 Congressional Dr.
West Plains Ind. Park Head & Sons Inc.
St. Louis, MO 63146 i
11773 Lackland Ave.
St. Louis, MO 63146 i
Attachmsnt 3 Mine Safety Appliance Nagle Pumps Inc.
Filter Prod Div.
Paul Demay & Associates P.O. Box 429 17536 Chesterfield Pittsburgh, PA 15230 Airport Rd.
Chesterfield, MO 63017 314-532-0505 Missouri Alloy Stud Inc.
P.O. Box 5427 Broadway Station Nash Engineering Co.
St. Louis, MO 63147 97 Progress Parkway Maryland Heights, MO 63043 Missouri Illinois Tractor &
Equip. Co.
NATCO Fasteners Inc.
2 5920 N. Lindbergh 11688 Fairgrove Industr.
Hazelwood, MO 63042 Maryland Heights, MO 63043 Missouri Machinery & Engineering Co.
National Auto Supply Co.
I 918 S. Fourth St.
1120 M. L. King Dr.
St. Louis, MO 63102 E. St. Louis, IL 62201 Missouri Power Transmission National Elec. Serv. Co.
3226 Blair 321 Lombard Street St. Louis, MO 63107 St. Louis, MO 63102 Mobile Equipment Corp.
National Meter Parto i
7301 Galveston Rd.
240 Baldwin Dr.
Houston, TX 77034 P.O. Box 908 1
Lancaster OH 43130 l
Moped Company l
R. R. Kinyon Co.
National Sales Co.
9216 Clayton Rd.
4201 Duncan Ave.
St. Louis, MO 63124 St. Louis, MO 63110119 314-993-4348 The National Torch Tip Co. Inc.
i Mosler Inc.
50 Freeport Rd.
l 445 Sovereign Ct.
Pittsburgh, PA 15215 Manchester, MO 63011 TRW Don H. Hunger & Co. Inc.
Nelson Stud Welding Div.
1150 Hanley Ind. Ct.
11710 Adiminstration Dr.
St. Louis, MO 63144 Suite #5 St. Louis, MO 63141 N J Associates Inc.
3214 S. Big Bend Blvd.
R. A. Nieberding Co.
St. Louis, MO 63144 8480 Pershall Rd.
Hazelwood, MO 63042 1 -
Attachmsnt 3 Oberjuerge Rubber Co.
Patton & Farrell, Inc.
P.O. Box 519 2258 Schuetz Rd.
St. Louis, MO 63166 Suite 202 St. Louis, MO 63146 0'Brien Equipment Co.
1919 Hampton Ave.
St. Louis, MO 63139 Peerless Pump Co.
Ulmer Equipment Co.
1554 Fernsark Dr.
Ohio Brass Company Fenton, MO 63026 Customer Service Group 314-343-4606 P.O. Box 1001 Wadsworth, Ohio 44281 Peerless Pump Co.
8050 Watson Rd.
St. Louis, MO 63119 P S A Industrial Marketing Inc.
237 Lancaster Ave.
Pennsylvania Crusher Corporation Suite 201 Hagedorn & Gannon Co. Inc.
Devon, PA 19333 456A Sovereign Ct.
Manchester, MO 63011 314-227-6800 4
P S L Energy Services Inc.
P.O. Box 937 Windsor, CT 06095 Permutit Company P.O. Box 355 E 49 Midland Ave.
Paramus, NJ 07652 Pappas Stainless & Alloy Inc.
Box 6304 Shawnee Mission, KS 66206 Philad=1phia Gear Corp.
4807 Cass Square Room 200 Parts Engineering Co.
Belleville, IL 62223 P.O. Box 402 llazelwood, M0 63042 H. K. Porter Co. Inc.
Electrical Division Patterson Pump P.O. Box 8277 Digital Systems Sales Inc.
Shawnee Mission KS 66208 P.O. Box 961 New Albany, IN 47150 812-948-5134 Attachm:nt 3 Power & Engineering R T & E Corp.
Products Company 1456 Westbrook Meadows Lane P.O. Box 382 Manchester, MO 63021 151 Helen Street South Plainfield, NJ 07080 Radeco Division of Science Applications Incorporated Henry Pratt Co.
10373 Roselle Street Van Devanter San Diego, CA 92121 Engineering Co. Inc.
1617 Manufacturers Dr.
Fenton, MO 63026 Reliance Automotive Service Inc.
314-343-8880 490 N. Kingshighway St. Louis, MO 63108 Process Chemical Equip. Co.
P.O. Box 1328 Research-Cottrell Inc.
42-A Worthington Dr.
P.O. Box 1500 Maryland Heights, MO 63043 Somerville, NJ 08876 Production Tool & Supply Co.
Riley Stoker Corp.
620 Shenandoah Ave.
Rhodes Equipment Co.
St. Louis, MO 63104 8704 Manchester Rd.
St. Louis, M0 63144 314-962-8820 Progress Envir. Corp.
88 Worthington Dr.
thryland Heights, MO 63043 Rockwell International Flow Control Division Pro Quip Inc.
400 Maple Ave.
P.O. Box 165 Carpentersv111e, IL 60110 Macedonia, OH 44056016 l
Rockwell International i
Pulsafeeder Wescom Inc.
M. C. Fridley Co.
2700 Rockereek Pkwy.
612 Cepi Dr.
Suite 307 Chesterfield, MO 63017 N. Kansas City, MO 64116 314-537-2030 Rockwell International Energy R E C Corporation Systems Group Ten Beach St.
8900 De Soto Avenue Mt. Vernon, NY 10550 Canoga Park, CA 91304 i
" I
Attachmsnt 3 a
Roedel Brothers Inc.
L. E. Saver Machine Co.
1035 N. Kirkwood Road 3335 Tree Court Kirkwood, MO 63122 Industrial Blvd.
St. Louis, MO 63122 Roland Machinery Co.
Midway Equipment Div.
Schuhmacher Fire Equip.
2380 Cassens Dr.
308 East Eighth St.
Fenten, MO 63026 Washington, MO 63090 Rosemount Analytical Division 3401 Hollenberg Dr.
Seals Inc.
Bridgeton, MO 63044 11485 Dorsett Road St. Louis, MO 63043 Rosemount Inc.
3401 Ho11enberg Dr.
Sears-Westall Co.
Bridgeton, M0 63044 702 Hanley Ind. Ct.
St. Louis, MO 63144 Milton Roy Company Paul Demay & Associates Security Fire Door 17536 Chesterfield P.O. Box 7389 Airport Rd.
St. Louis, MO 63177 Chesterfield, MO 63017 314-532-0505 Security Locknut Inc.
4631 West North Ave.
Rubelmann-Lucas Inc.
Chicago, IL 60639 10800 Midwest Ind. Blvd.
St. Louis, M0 63132 SEMCOR 5432 Highland Park Dr.
S & K Air Power Tool & Supply Corp.
St. Louis, MO 63110 P.O. Box 1279 Mattoon IL 61938 Service Supply Co.
3715 Pennridge Dr.
St. Louis Screw & Bolt Bridgeten, MO 63044 6900 N. Broadway St. Louis, MO 63147 l
Shannshan Crane & Hoist Parts Inc.
I 4334 Bridgeton Ind. Dr.
St. Louis Valve & Fitting Co.
Bridgeton, MO 63044 P.O. Box AB Fenton, MO 63026 1
Shipping Utilities Inc.
10539 Liberty Ave.
i Samson Supply & Mfg.
St. Louir, MO 63132 1460 W. Airline Hvy.
Waterloo, IA 50703 a
p :
Attachmsnt 3 Sidener Supply Co.
Spence Engineering Co.
P.O. Box 1309 Control P;oducts Inc.
45 Northgate Ind. Dr.
1668 Headland Dr.
Granite City, IL 62040 Venton, MO 63026 314-343-9501 Siemens Energy & Automation Inc.
11789 Bormen Dr.
State Electric Co.
P.O. Box 28609 1977 Congressional Dr.
St. Louis. H0 63146098 St. Louis, MO 63141 Stock Equipment Co.
Skil Corp.
1201: Manchester Rd.
1238 S. Vandeventer Ave.
- c. t. Louis, MO 63131 St. Louis, MO 63110 Superior Fast ner Co. Inc.
Sprague Meter Div. of 8525 Vulcan Sangamo Weston Inc.
St. Louis, MO 63111389 35 South Ave.
Bridgeport, CT 06601214 Sweeney Industries Inc.
i 207 Koening Wentzville, MO 63385 SLIGO, Inc.
P.O. Box 171 St. Louis, MO 63166 TECO, Inc.
Zoltek Corporation 3101 McKelvey Rd.
Snap On Tools Corp.
St. Louis, M0 63044 4156 Shoreline Drive P.O. Box 838 Bridgeton, MO 63044 Teleflex Inc.
P.O. Box 218 Church Road Southern Bolt & Fastener Corp.
North Wales, PA 19456 P.O. Box 7196 Shr.eveport, LA 71107 Tiemann Ind. Howe P.O. Box 14406 Southern States Inc.
St. Louis, MO 63178 Waternan & Watornan Creve Coeur Executive Office Park
-i 745 Craig Rd.
C. M. Tilley Co. Inc.
Suite 300 742 Goddard Ave.
i St. Louis, MO 63141 Chesterfield, MO 63017 314-432-6709 Tools & Supplies. Inc.
Special T Metals Co. Inc.
11600 Adie Rd.
1 8425 Mid County Ind. Dr.
Maryland Heights. Ho 63043 St. Louis, MO 63114 i
Ulmer Equipment Co.
1554 Fenpark Dr.
Fenton, MO 63026 -
l Attachnent 3 Unistrut Service Co.
Wallace & Tiernan Sales Corporation 2722 Mercantile Dr.
P.O. Box 875 St. Louis, MO 63144 Shawnee Miss!on, KS Wallace & Tiernan Div.
i United Conveyor Corp.
Pennvalt Corp.
Hesler Company 25 Main Street l
P.O. Box 8207 Bellevi)1e, NJ 07109 i
Prairie Village, KS 66208 314-454-0215 Waterman A Waterman Creve Coeur Executive United Technologies Elliott Office Park 50 Crestwood Exec. Ctr.
745 Craig Rd. Suite 300 St. Louis, MO 63126 St. Louis, MO 63141 l
Utilities Service Co.
Jervis B. Webb Company George Dubois Co.
34203 Webb Dr.
2405 Hollyhead Dr.
Farmit.gton Hills, MI 48331562 St. Louis, MO 63131 431-355-3100 314-965-4790 WESCO 2820 Market St.
Val-Quip Co. Inc.
St. Louis, MO 63103 P.O. Box 10970A St. Louis, MO 63135 Westinghouse Electric Corp.
P.O. Box 28540 2060 Craigshire Rd.
l Van Devanter Engineering Co. Inc.
St. Louis, MO 63146 1617 Manufacturers Dr.
Fenton, MO 63026 Worthington Pump Div. Of Dresser Industries, Inc.
Vanton Pump & Equipment Corp.
6901 W. 63rd St.
Westfall Company, Inc.
Overland Park, KS 66202 232 Axminister Dr.
Fenton, MO 63026 314-343-5855 Yarway Corporation Blue Bell, PA 19422 Vermeer Sales & Services MI Inc.
Zeuschel Equipment Co.
P.O. Box 273 2717 Breckenridge Ind. Court Chesterfield Airport Rd.
Brentwood, MO 63144 Chesterfield, MO 63017 Zoltek Corporation Vincent Metals 3101 McKelvey Rd.
2150 S. 59th St.
St. Louis, MO 63044 St. Louis, MO 63110 Zurn Industries Vitco Nuclear Products Inc.
A. L. McMin & Co. Inc.
8111 Tyler Blvd.
P.O. Box 1467 Mentor OH 44060 Belleville IL 62223 618-569-7075 Attachmsnt 4 to ULNRC-1811 Page 1 of 36 Indirect Suppliers of Non-safety-related Fasteners A & G Engineering Co.
Air Products & Chemicals, Inc.
4640 E. LaPalma Ave.
Dept. 3 Anaheim, CA 92807 P.O. Box 96005 714-779-4100 Chicago, IL 60693 312-785-4614 A B Chance Co.
210 N. Allen St.
Air Products & Chemicals. Inc.
Centralia, MO 65240 Industrial Gas Div.
314-343-3750 13701 Green Ash Court Earth City, MO 63045 i
314-739-6211 ACE Electrical Parts P.O. Box 1328 Kansas City, MO 64141 Air Products & Chemicals Inc.
800-892-8758 A11enton, PA 18195 4
215-481-4911 ACE Maintenance Supply Co.
4399 Chouteau Air Products Division St. Louis, MO 63110 General Blower Co., Inc.
314-535-1000 P.O. Box 69 Darby, PA 19023 215-461-2300 Acetylene Gas Co.
3500 Barnard St.
St. Louis, MO 63103 ALC0A Aluminum Co.
314-533-3100 8301 Maryland Ave.
St. Louis, MO 63105 A D Michel Co.
314-863-0300 2505 Metro Blvd. Ste. C Maryland Heights, MO 63043 314-567-5670 ALC0A Conductor Products Kenway Co.
Aeroquip Corporation Suite A Tomkins Johnson Div.
8 The Pines Ct.
Lucas Pluid Power Inc.
St. Louis, MO 63141 Moehlenpah Engr. Div.
314-469-9998 11999 Borean J
St. Louis, MO 63146 314-469-9100 ALCOA Conductor Accessories, Inc.
1 RR Kinyon Co.
9216 Clayton Road I.
Air Hydraulics Co.
St. Louis, MO 63124 6074 Baumgartner Ind. Dr.
314-993-4348 i
St. Louis, MO 63129 l
314-487-9100 Allen & Allen Agency, Inc.
Combustion Engineering 1130 S. 6th St.
l Air Preheater Company St. Louis, MO 63104 850 Warrenville Road 314-621-0072 Suite 302 Lisle, IL 60532 312-963-7870 i
Attachmsnt 4 Allen Nuclear Associates, Inc.
ALTEC Industries Inc.
i l
P.O. Box 1267 2106 South Riverside Road 129 Avenida Victoria St. Joseph, MO 64503 l
San Clemente, CA 92672 816-364-2244 4
714-498-3350 ALTEC Industries, Inc.
Allen Sherman Hoff Co.
P.O. Box 10264 Rhodes Equipment Co.
Birmingham, AL 35202 8704 Manchester Road 205-323-8751 t
St. Louis, MO 63144 314-962-8820 American Bristol Industries Inc.
1600 W. 240th St.
l Allis Chalmers Environmental Harbor City, CA 90710 l
6 Energy Systems, Inc.
213-534-5981 546 McBride Point Drive Ballvin, MO 63011 314-256-6800 American Brake Shoe Compnay l
IC Industries /Abex Corp.
j Friction Products Group l
f Allis Chalmers 2410 Papermill Road
)
1 Zeuschel Equipment Company P.O. Box 3250 2717 Breckenridge Ind. Court Winchester, VA 22601 Brentwood, MO 63144 703-662-3871 314-645-5003 American Bridge Division Allis Chalmers Co.
US Steel Corp L
Hydro Turbine Div.
515 Olive Str.
P.O. Box 360-374M York St. Louis, MO 63101 j
Pittsburgh, ?A 15251 314-421-6464 American Foundry & Mfg.
Allis Chalmers P.O. Box 5544 l
1150 Tennessee Avenue St. Louis, Ho 63147 Cincinatti, OH 45229 314-231-6114 513-482-2543 I
American Meter Co.
Allis Chalmers Corp.
2$01 S. Fairfield 10965 Granada Lane Suite E Suite 200 Lombard, IL 60148 i
Overland Park, KS 66211 312-971-1480 I
381 1740 American Standard A C Valve Inc.
Heat Transfer Div.
j P.O. Box M93 228 N. Lasalle St.
]
York, PA 17405 Chicago, IL 60601 717-792-9783 312-346-2533 2-1
Attachmsnt 4 i
American Standard Atlas Copco Industrial Prod. Div.
1385 Armor Blvd.
120 Progress Parkway Mundelein, IL 60060 Maryland Heights, MO 63043 312-566-5888 314-878-4398 i
]
Auma Actuators, Inc.
American Standard Ind. Prod.
4 2esta Drive Industrial Prod. Div.
Pittsburgh, PA 15205 d
10100 Sante Fe 412-787-1340 j
Overland Parks, KS 66212
(
913-381-6866 Ceneral Signal Corporation l
Aurora Pump American Standards Testing Bureau 800 Airport Rd. North
(
40 Water St.
Aurora, IL 60542 l
I New York, NY 10004 312-859-7000 i
314-621-3900
)
Automatic Sprinkler i
Textron Inc.
2445 Rock Island Blvd.
l Camcar Division Maryland Heights, MO 63043 l
600 18th Avenue 314-432-1828 i
Rockford, IL 61108-5181 F
815-226-3600 Atito Vehicle Parts Co.
7 Sporti Drive APEX P.O. Box 17350 j
10714 Manchester Road Corrington, KY 41017 l
1 Suite 204 606-341-6450 St. Louis, MO 63122 l
314-821-2118 Auveco Products Auto Vehicle Parts Co.
APEX Welding, Inc.
P.O. Box 17350 D-TR P.O. Box 46199 Covington, KY 41017 l
Bedford, OH 44146 800-354-9816 t
j 216-232-6770 t
i The Babcock & Wilcox Co.
l 1
Appleton Electric Company Refractories Div.
j 1701 W. Wellington Avenue 1221 Locust Street 1
Chicago, IL 6065/
St. Louis, MO 63103 4
312-327-7200 314-241-5249 I
1 i
J Atlas Copco The Babcock & Wilcox Co.
j j
Industrial Compre'=or Tubular Products Div.
]
4255 Parker Roai 29 South Lasalle Street I
Florissant, MG v N -
Room 742 314-839-4142 Chicago, IL 60603 618-363-0052 I
i l J 1
Attachmane 4 t
Babcock & Wilcox Bailey Controls Co.
i Control Components Div.
611 East Butterfield Road 2567 S.E. Main St.
Suite 104
[
Irvine, CA 92705 Lombard, IL 60148 714-979-6600 312-968-8691 Bailey Controls Co.
Babcock & Wilcox Const. Co., Inc.
12963 Maurer Ind. Dr.
P.O. Box 371648M St. Louis, MO 63127 Pittsburgh, PA 15251 314-842-5700 No Phone Bailey Controls Co.
Chas M. Bailey Co., Inc.
29801 Euclid Avenue Ulmer Equipment Osmpany Wickliff, OH 44092-9990 1554 Fenpark Drive 216-585-8500 i
Fenton. MO 63026 314-343-4606 Eailey Office Furniture 104 Whitewater Dr.
Bailey Controls St. Louis, M0 63011 i
417 2nd Street 314-227-0709 Williamsport, PA 17701 j
216-585-7305 i
E G Bailey Training Center 2882 Cricket Lane Bailey Controls Willoughby Hills, OH 44092 Chicago Service Lab 800-447-0111 537 Taft Ave.
South Holland, IL 60473 312-596-3070 Barrett Electrical Supply Co.
45 Worthington Drive Haryland Heights, MO 63043 Bailey Controls 314-878-1300 Parts Order Administr.
29801 Euclid Ave.
Wickliffe, OH 44092 G. T. Barutto i
800-554-9030 7715 Brookline i
Richmond Heights H0 63117 No Phone Bailey Controls Co.
333 Hwy. 46 Pairfield, NJ 07006 Bath Iron Works Corporation No Phone 700 Washington Street i
Bath, ME 04530 207-443-3311 1
Bailey Controla Co.
A D Michel Co.
2505 Metro Blvd. Ste. C Bayers Garden Shop Haryland Heights, Ho 63043
$926 Old State Road 314-567-5670 Imperial, Ho 63052 314-464-2314 i
1 Beckman Instrument Co.
Bethlehem Steel Corp.
630 Puente 7701 Forsyth Blvd.
Brea, CA 92621 St. Louis, MO 63105 714-671-4804 314-726-4500 3
Beckman Instruments Bi-State Machinery Co.
3311 N. Kennicott Avenue 4303 Bist. ate Ind. Dr.
I Arlington Heights, IL 60004 St. Louis, MO 63128 j
800-742-2345 314-487-7100 l
I Beckms:, Instruments, Inc.
Bi-State Fastener Co.
2500 Harbor Blvd.
8595 St. Charles Rock Rd.
Fullerton, CA 92634 St. Louis, MO 63114 1
714-871-4848 314-426-1480
(
i B D R Engineering Corp.
Biach Industries, Inc.
1307 N Seventh St.
P.O. Box 260 Columbia, MO 65201 75 Chestnut St.
314-442-3417 Cranford, NJ 07016 i
201-276-3110 i
1 Beach-Russ Company 544 l'nion Avenue Blaw Knox Equipment i
Brooklyn, NY 11211 P.O. Box 1140 l
718-188-4090 St. Charles, MO 63301 314-946-5979 4
Bechtel Power Corp.
g 15740 Shady Grove Rd.
Black and Decker Mfg. Co.
2 Gaithersburg, MD 20760 12852 Manchester Rd.
I St. Louis, MO 63131 j
314-821-8740 Beck FMterials Co.
P.O. Box 534 5
Jefferson City, MO 65102 Borg Warner No Phene 5005 Interstate Drive In Morman, OK 73069 405-364-4040
]
Beck Materials Co.
i 511C East McCarty St.
l
'efferson City, MO 65101 Borg Warner Air Cond. Inc, j
J14-896-4530 11645 Northline Ind.
i Maryland Heights, MO 63043 l
314-567-5684 j
Belco Pollution Control Corp.
Eight Peach Tree Hill Livingston, NJ 07039 Borg Warner
.01-535-2494 P.O. Box 2185 Van Nuys, CA 91409 f'
818-781-4000
, e Y -.-
Attachmsnt 4
]
e i
Borg Warner Industrial Products Inc.
Brauer Supply Company i
6475 Joliet Rd.
4260 Forest Park Blvd.
Lagrange. IL 60525 St. Louis, MO 63108 i
618-465-5005 314-334-7150 l
l Borg Warner Brewer Machine & Gear Hechanical Seal Div.
2820 Clark Ave, 4
d 6001 Vollmer Ln.
St. Louis, MO 63103
]
Codirey, IL 62035 314-534-4021 i
618-466-3007 l
l i
Asea Brown Boveri Borg Warner Air Conditioning, Inc, 11715 Administration Dr.
i P.O. Box 2069 St. Louis, MO 63146 t
j Columbia, MD 20045-1069 314-567-7124 I
No Phone B B C Brown Boveri, Ir.c.
BW/IP International Inc.
1300 West Lark Ind. Park Byron Jackson Products Fenton, MO 63026 695 Church St.
314-343-0232 l
Interstate 90 and Rte. 21 Elgin IL 60123 l
312-741-0400 Bruening Bearin>5 i
P.O. Box 765 Fenton, MO 63026 J. Bovman Associates 314-343-6220 l
Box 9186 j
St. Louis, MO 63117 314-863-8318 Bruening Bearings P.O. Box 338 i
St. Peters, MO 63376
{
Bowman Distribution 314-928-1163 j
Larry Hale l
I 107 N. West End Blvd.
l l
Cape Girardeau, MO 63701 Bruening Bearings Inc.
314-335-7063 P.O. Box 1011 J
Jefferson City, M0 65102 314-635-7971
]
3ranson Indus. Products 2363 59th St.
t St. Louis, MO 63110 Bruening Bearings, Inc, 314-645-7240 2727 Washington Ave.
j St. Louis, MO 63103 314-533-0837 Brauer Supply Co.
j 1516 Wyoming Street
]
Columbia, MO 65201 Brewer Machine and Gear 800-322-3120 2820 Clark Ave.
j St. Louis, MO 63103 314-534-4021
)
J l '
I
I r
F t
f i
i l
l Budd Company Callavay County Sand Company i
Wheel and Brake Division Hokane, MO 65059 24755 Halsted No Phont l
Farmington Hills, MI 48018 313-473-9700 Callaway Farmers Equipment Co., Inc.
P.O. Box 38 i
Burndy Electrical Group Fulton, MO 65251 i
Burndy Corporation 314-642-3389 l
Richards Avenue
]
Norwalk, CT 06156 1
203-833-4444 Anchor Packing Company 408G Airpack Ca111more Dairy Road
)
Greensboro, NC 27409 919-668-7955
}
Butler Electrical Contracting Co., Inc, j
200 S. Central 1
Eureka, MO 63025 Capitol controis l
314-587-3456 Environmental & Energy Systems Inc.
$46 McBride Point Dr.
Ballvin, MO 63011 l
j Butler Supply Inc.
314-256-6800 5715 Elizabeth Ave.
St. Louis, MO 63110 314-647-5333 Cardinal Electric l
Motor Rapair l
753 Forest Ave.
l Byron Jackson Pump Company St. Louis, MO 63088 i
j Borg-Warner Industrial Products. Inc.
314-225-6650 i
Pumps Division i
200 Oceangate Blvd. Suite 800 l
l P.O. Box 22634 Cardinal Industrial Products. Inc.
Long Beach, CA 90801 3873 West Oquendo Rd.
l 213-436-0500 Las Vegas, NV 89118 i
}
702-739-1966 i
l
]
C M Tillay Co., Inc, 742 Coddard Ave.
Cardinal Industrial Ser.
l
{
Cherterfield, MO 63017 100 Sun Valley Circle l
j 314-537-2800 Fenton, MO 63026 l
314-349-1599 d
"adillac Meter Co.
P.O. Box 1175 Cardinal Industries, Inc.
]
Port Townsend, WA 98368 Box 1430 206-385-5500 Grundy, VA 24614 t
800-336-0551 Callaway Auto Parts Inc.
l 608 Market Street Cardinal Scale Mfg. Co.
f I
Fulton, MO 65251 11005 Lin Valle Dr.
l 314-642-6831 St. Louis, MO 63123 l
314-487-1215 l
d 1
c
= _
Attechmsnt 4 t
l 1
Carlson Systems Clark Reliance Corp.
1720 Mackland Avenue Rhodes Equipment Co.
i 4
St. Louis, MO 63110 8704 Manchester Road 314-772-8600 St. Louis, MO 63144 314-962-8820 i
{
1 Carr Lane Manufacturing Co.
7 4200 Carr Lane Court Clifford Ir.c.
l P.O. Box 13149 83 Main St. Louis, MO 63119 Bethel VT 05032 I
314-647-6200 800-451-4381
)
Carver Supply Incorporated Control Components
[
1 1414 East Third Street C. M. Tilley Co., Inc.
Dayton. OH 45403 742 Coddard Ave.
513-461-9673 Chesterfield. MO 63017 l
314-537-2800 l
t Central Controls Co., Inc.
11723 Northline Ind.
Control Components t
P.O. Box 24 1325 South Creek Dr.
i j
Maryland Heights. MO 63043 Suite 300 l
314-991-1440 Houston TX 77084 f
713-492-6904
[
j t
i l
Champion Tools. Inc.
[
l 111 Hilltown Village Control Components j
Chesterfield, MO 63017 Chemical Piping Sys. Inc.
314-532-4160 10836 Galt Ind. Dr.
St. Louis MO 63132
(
j
)
314-428-0033 J
CBI Industries Inc, l
800 Jori Blvd.
l l
Oak Brook. IL 60522 control Components i
312-572-7100 22591 Avenidi Empressa i
Rancho Santa Margarita. CA 92688 1
l 714-858 1877 1
Chicago Heater Co.. Inc.
1900T Johnson Drive 1
Mission Woods. KS 66205 Conveyor & Drive Equipment Co.
i j
913-384-2500 P.O. Box 10740 St. Louis, MD 63129 i
314-961-1200 I
Chicago Pneumatic Tool l
2200 Bleecker St.
l Utica, hT 13501 Co op Service Station 1
314-645-7511 P.O. Box 147 La Plata. MO 63549
)
816-332-7615 Chrysler Corp.
]
20026 Progress Drive i
l Strongville. OH 44136 No Phone 1 j 1
Attachraa 4 i
1 Collins & Hermann Inc.
K. Connelly Inc.
1215 Dunn Road 22 Oakwood Rd.
P.O. Box 13579 Huntington, NY 11743 St. Louis, MO 63138 516-549-4333 314-869-8000 John Connelly Roofing Co.
l Collins Product Company 825 Marcha11 Road P.O. Box 382TR Valley Park, MO 63088 i
l Livingston, TX 77351 314-225-8351 409-327-4200
)
Consolidated Pipe & Supply Colt Industries 6401 Graham Road Fairbanks horse Engine Div.
St. Louis, MO 63134 701 Lawton Ave.
314-521-7100 Beloit, WI 53511 608-364-4411 1
i Continental Alloy Steel
{
P.O. Box 8000 Combustion Engineering Chagrin River Road 2
6362 College Blvd.
Cates Hills, OH 44040 i
l overland, KS 66211 800-321-3238
]
913-491-6511 I
Conveyor & Drive Equipment Co.
Combustion Engineering Inc.
P.O. Box 10740 t
P.O. Box 910047 St. Louis, MO 63129 L
Dallas, TX 75391 314-961-1200 i
214-748-3096 j
Conveyor Components Co.
i C E Basic Chemicals 130 Seltzer Road j
7887 Hub Parkway Craswell, MI 48422 i
Cleveland, OH 44125 313-679-4211 i
4
)
216-524-9000 l
4 Cooper Turner Combustion Enginsering Keystone Ind. Part j
4400 College Blvd, 200 Rittenhouse Circle j
Suite 100 E Bldg 8 l
J Overland Park, KS 66211 Bristol, PA 19007
[
913-491-6511 No Phone j
i i
Combustion Engineering Cooper Electric Sales, Inc.
]
P.O. Box 1422 70 D Grasso Plass Ba11 win, NO 63022-1422 P.O. Box 6927 1
314-394-2825 St. Louis, MO 63123 j
314-638-3434 i
t
\\
i The Condit Inc.
111 West Port Plaza Suite 600A St. Louis, MO 63146 314-878-6251 Attachmsnt 4 i
9 i
Cooper Ini'ustries Crane Company
)
Energy Services Group Valve Serv. & Repair Div.
West Chestnut St.
3602 W.
12th Mount Vernon, OH 43050 Houston, TX 77008 614-393-8200 713-862-8821 t
Cope Plastics Inc.
Crane Compeny i
6340 Knox Industrial Drive Chempump Division l
St. Louis, MO 63139 175 Titus Avenue 314-644-5120 Warrington, PA 18976 215-343-6000 Copes-Vulcan, Inc.
Hesler Company Crane Company P.O. Box 8207 Midwest Machinery Company l
Prairie Village KS 66208 41' Hanley Ind. Ct.
)
314-454-0215 St. Louis. Ho 63144 314-647-3250 Copes-Vulcan Inc.
P.O. Box 577 Deming Pump Company Lake City, PA 16423 1453 Allen Road, Box 450 814-774-3151 Salem, OH 44460-0450 216-337-7861 Corrosion Products, Inc.
635 Hanley Indust. Ct.
Crescent Parts & Equip. Co., Inc.
St. Louis, MO 63144 2100 South 39th Street 314-781-1200 St. Louis, MO 63110 314-647-5511 Crane Aloyco, Inc.
12 East Devonwood Crescent Plumbing Supply Company Romeoville, IL 60441 640 Rosedale Ave.
815-886-1710 St. Louis, MO 63112 i
314-727-4200 l
Crane Valve Services 1120 Ohio View Ave.
[
Ambridge, PA 15003 43 Kendrick Street r
412-266-8350 Wrentham, MA 02093 617-384-3121 Crane Company Valve Srv. 6 Repair Div.
Crosby Valve & Gage 12 East Devonwood Randon Company Romeov111e, IL 60441 1027 So. Vandeventer 800-435-4851 St. Louis, MO 63110 l
314-652-5950 Crane Company 3241 Industrial Dr.
Signal Hill, CA 90806 213-498-3321 __
. _ _ _ = __
Attachmsnt 4 I
l 4
f Cryochem. Inc.
Navistar International Corporation Rt. #2, P.O. Box 74A 401 N. Michigan Avenue Boyertown, PA 19512 22nd Floor I
215-680-9531 Chicago, IL 60611 l
312-836-3609 Cushman Electronics, Inc.
1525 Atteberry Lane Daniel Const. Company San Jose, CA 95131 Daniel Building 408-263-8100 Greenville, SC 29602 No Phone Custodis Ecodyne Inc.
37 W. 222 Rt. 64 Daniel Industries Suite 256 Systems Divisiou B 8015 Mercantile Plaza Gateway Controls. Inc.
St. Charles, IL 60174 1302 West Lark 312-584-1110 Industrial Park Fenton, MO 63026 314-343-9000 Cust odis Ecodyne, Inc.
P.O. Box 75139 Cincinnati, OH 45275 Daniel International Corp.
606-586-8000 P.O. Box 146 i
Stravn, KS 66839 No Phone Eaton Corporation Controls Divisien r
{
191-T E. North Avenue Daniels Service Mobil i
Carol Stream, IL 60187 P.O. Box 278 i
312-260-3400 Parma, MO 63870 No Phone
{
Cypress Mfg.
{
P.O. Box 17802M George A. Davis St. Louis, MO 54106 Asbestos Workers Tools No Phone P.O. Box 34581 f
l Richrond, VA 23234 I
804-175-5906 Donley Geigher, Inc.
l 4
P.O. Box 5515 3401 North Broadway Davia Oil Company L
i St. Louis, MO 63147 600 Main 1
314-421-1758 Boonville, MO 65233 816-882-7925 l
i G. W. Dahl Company, Inc.
j Val-Quip Co., Inc.
Davis Rental Service j
P.O. Box 10970A 9625 S. Broadway l
St. Louis, Mo 63135 St. Louis, MO 63125 l
J 314-524-3300 314-544-1212 i
I
- ti -
)
l 4
Attachmsnt 4 j
Dean Machinery Dixie Electrical Mfg. Co.
1201 W. 31st Street Kenway Co.
Kansas City, M0 63141 Suite A 816-753-5300 8 The Pines Ct.
St. Louis, MO 63141 314-469-9998
)
Delavan Inc. Process 4
Instrumentation Oper.
Gateway Controls Inc.
Dixons Quick Stop
.i 1302 West Latk Hwy. 79 Industrial Park Winfield, MO 63389 Fenton, MO 63026 314-668-8122 314-343-9000 Don H. Munger & Co., Inc.
Delta Y Electric 1150 Hanley Ind. Ct.
2002 N. Kingshighway St. Louis, MO 63144 Cape Girardeau, MO 63701 314-961-8100 314-651-3660 Donley Gi gher Inc.
Delta Y Electric Co.
P.O. Box 5515 R. R. Kinyon Co.
3401 North Broadwa) 9216 Clayton Road St. Louis, MO 63147 St. Louis, MO 63124 314-421-1758 314-991-4348 Donovan Industrial Supply Corp.
DeZurik 917 Hodiamont Ave.
250 Riverside Avenue North St. Louis, MO 63112 l
Sarte11 MN 56377 314-725-8840 i
612-259-0505 Dorman Products. Inc.
l Diamond Power Specialty 10000 Alliance Road 4640 Western Ave.
Cincinnati, OH 45242 Lisle, IL 60532 513-984-1000 312-968-9245 l
t Dorsett Auto Parts Dionex Corp.
12685 Dorsett Road 1228 Titan Way Maryland Heights, MO 61043 3
Sunnyvale, CA 94086 314-434-6390 i
l Ditch Witch Dresser Industries Inc.
P.O. Box 429 Central Controls Co., Inc.
Sullivan, M0 L3080 11723 Northline Ind.
314-468-8012 P.O. Box 24 Maryland Heights, MO 63043 314-991-1440 i -
e
. _ = _
Attachmsnt 4 Dresser Industries DuBose Steel Inc.
Carl'.:on Company P.O. Box 1098 l
9291 Watson Road Roseboro, NC 28382 i
St. Louis, MO 63126 919-525-4161 314-968-3850 Duff North Company Dresser Industries P.O. Box 32605-T i
Heise Plant Charlotte, NC 28232 I
J P.O. Box 515 No Phone 153 So. Main Street Newtown, CT 06470 l
203-426-3115 Dwyer Instruments Inc.
P.O. Box 373T i
Michigan City, IN 46360
)
Dresser Mfg.
219-872-9141 41 Fisher Ave.
i Bradford, PA 16701
['
814-368-3131 East Alton Supply Co.
i 328 Shamrock Rd.
{
East Alton, IL 62024 I
1 Dresser Industries 800-851-4451 i
Dresser Instruments Div.
l 253 E. Main Street Stratford, CT 06497 Eastern Control Systems, Inc.
203-378-8281 2114 Dabney Road P.O. Box 6983 j
Richmor.d. VA 23230 i
1 Dresser Mfg. Division 804-358-6904 Dresser Ind. Inc.
J 3205 North Wolf Road 1
P.O. Box 336 TMA Eberline I
Franklin Park, IL 60131 Thermo Analytical Inc.
312-451-3965 P.O. Box 3874 i
Albuquerque, NM 87190 4
505-345-9931 j
Dresser Industries. Inc.
Industrial Valve y
P.O. Box 1430 Eberline Instrument Corporation Alexandria, LA 71301 504 Airport Rd.
318-640-2250 Santa Fe, NM 87504-2108 505-471-3232 i
Dresser Industries, Inc.
j Contruction Equipment Allan Edwards Company 755 S. Milwaukee Ave.
P.O. Box 9457 Libertyville, IL 60048 Tulsa, OK 74157 2
312-367-2829 918-583-7184 q
I 1
Dresser Industries Inc.
E S I Inc.
)
Jeffrey Mfg. Division Engineer Supplies Inc.
1 P.O. Box 387 2942 Harrison St.
l Woodruff SC 29388 Davenport, IA 52803 1
803-476-7523 319-324-2135 l _ _ _,
Attachmsnt 4 Elastmold Division Farrar Pump & Machinery Electrorep Inc.
1701 S. Big Bend Blvd.
j 83 Weldon Parkway St. Louis, MO 63117 Maryland Heights, MO 63043 314-644-1050 314-991-2600 f
j Farval Div, Elgin Sweeper Company Cleveland Gear Company P.O. Box 537, Dept. TR 2501 Airport Road Elgin, IL 60121-0537 Kingston, NC 28501 312-741-5370 919-527-6001 Elliott Company Fire Master 50 Crestwood Executive Center Division of Master Protection Enterprises i
Suite 523 435 Forbes Blvd.
]
St. Louis, MO 63126 South San Francisco, CA 94080 314-849-4811 415-952-6677 J
l 1
Engineering Fire Protection Inc.
Fisher Controls International Inc.
I 1666 Larking Williams Rd.
Don H. Hunger & Co., Inc.
Fenton, M0 63026 1150 Hanley Ind. Ct.
l
)
314-343-8049 St. Louis, MO 63144 d
314-961-8100 j
i i
Townsend Fastening Systems Townsend Div Fletcher Reinhardt Co.
1 Textron Inc.
11440 Schenk Drive 530 W. St., P.O. Box 765 Maryland Heights. Ho 63048 Braintree, MA 02184 298-0700 i
d 617-848-3500 l
Flygt Corporation Envirex, Inc.
Van Devanter Engineering Co., Inc.
j Pohlkotte Ressler Co., Inc.
1617 Manufactures L..
P.O. Box 458 Fenton, MO 63026 i
Ballwin, MO 63022-0458 314-343-8880 l
314-391-8992 Flygt Corporation
]
Fairmont Hydraulics Division of ITT 415 North Main 814 Fee Fee Road Fairmont, MN 56031 Maryland Heights, M0 63042 f
507-235-3361 114-569-2010
(
1 i
j Teledyne Farris Engineering F M C Corporation l
{
400 Commercial Avenue M H E Division j
Palisades Park, NJ 07650 Homer City, PA 15748 201-944-6300 412-479-8011 1
l i
! l 4
i
Attachmsnt 4 F M C Corporation Foxboro Co.
Carl F. Cast Co.
11715 Administration Dr.
930 N. McKnight Road Suite 102 St. Louis, MO 63132 St. Louis, MO 63146 314-993-2870 314-567-4377 T M C Corporation Foxboro Co.
125 Windsor Dr.
38 Neponset Avenue Suite 128 Foxboro, MA 02035 cak Brook, IL 60521 800-343-1198 312-574-0574 l
Foxboro Co.
i Ford Tool Steels. Inc.
Armstrong Rd.
5051 Pattison Ave.
Plymouth Ind. Pk.
St. Louis, MO 63110 Plymouth, MA 02360 I
314-772-3322 617-747-1130 Foster Wheeler Energy Corporation Foxboro Company Perryville Corporate Park Analytical Div.
Clinton, NJ 08809-4000 140 Water Street 201-730-4000 P.O. Box 5449 So. Norwalk, CT 06856-5449 203-853-1616 Foster Wheeler Energy Corp.
l 23400 West 82nd St.
Lanexa, KS 66227 Frankel Connector Co.
913-441-8883 N J Associates. Inc.
i 3214 S. Big Bend Blvd.
St. Louis, MO 63143 l
Foxboro Co.
314-645-2622 1901 S. Busse Rd.
Mt. Prospect, IL 60056 I
617-549-5225 Franklin County Glass, Inc.
I RR 3, Box 606 Washington, MO 63090 l
Foxboro Co.
No Phone Attnt Dept. 747 600 North Bedford St.
East Bridgewater, MA 02333 Franklin Janitor Supply 617-549-5225 1900 Locust St.
St. Louis, MO 63103 314-231-4191 Foxboro Co.
Analytical Div.
l P.O. Box 5449 Fischer & Porter Co.
151 Woodvard Avs.
Durkin Equipment South Norwalk, CT 06856-5449 81 M111vell Dr.
I 203-853-1616 Maryland Heights, MO 63043
(
314-291-0000 l
l Attachmsnt 4 j
Gardner-Denver General Electric Company 140 Boulder Ind. Dr.
Service Center Bridgeton, MO 63044 2355 Hampton Avenue 314-291-3800 St. Louis, MO 63139 314-342-7884 i
Carl F. Gast Co.
930 N. McKnight Rd.
General Electric Company St. Louis, MO 63132 Railroad Parts Center 314-993-2870 2301 South 3rd Street l
St. Louis, MO 63104 314-342-7849
)
General Accessory Mfg. Company l
10221 Corkwood, P.O. Box 550879 Dallas, TX 75255 General Electric Company i
214-348-6080 Instrumentation and Computer r
Sales & Service
[
1353 North Warson Road j
General Electric St. Louis, MO 63132 i
National Supply Sales 314-993-0537 2825C Pacific Dr.
Norcross, GA F,0?1 800-437-2537 General Electric Company Apparatus Service i
1115 East Road Canadian General Electric Co., Ltd.
St. Louis, MO 63110 i
General Electric Company 314-644-1990 1
1015 Locust St.
St. Louis, MO 63101 314-342-7741 General Electric Company j
Apparatus & Engineering Services l
P.O. Box 10506A l
I General Electric Atlanta, GA 30348
)
Electronics Park 404-447-7241 l
Building 6 Room 205 2
Syracuse, NY 13221
(
l 315-456-2998 General Electric Company i
Apparatus & Engineering l
8157 South Cass Avenue i
General Electric Darlen, IL 60559 l
175 Curtner Avenue 312-789-5900
]
San Jose, CA 95125 1
408 925-7253 General Electric Company
~
Nuclear Plant Serv. Dept.
l General Electric Cocpany 2311 W. 22nd Street j
Service Shop Suite 201 i
2455 Cassens Dr.
Oakbrook, IL 60521 Fenton, MO 63026 312-573-3929 i
j 314-343-1777 j
General Electric Cocipany P.O. Box 44375 San Francisco, CA 94144 No Phone 4 :
I i
_ _.. = _ -
Attachmsnt 4 l
l General Electric Company Glenn Products I
Mobile Communications 47 Lafayette Circle 744 Office Parkway Unit 306 St. Louis, M0 63141 Lafayette, CA 94549 314-432-1336 707-745-3102 General Electric Company Gorman-Rupp Company 730 West 45th Avenun 305 Bowman Street, P.O. Box 1217 Suite B Mansfield, OH 44901 Munster IN 46321 419-755-1011 800-437-3687 i
Gorman-Rupp Company i
General Electric Company Industries Div.
1 Lamp Division 180 Hines Avenue
[
1530 Fairview Bellville, OH 44813 l
St. Louis, Mo 63132 419-886-3001 314-429-6930 Could, Inc.
Gerieral Electric S pply Computer Systems Div.
1620 Headlan, P.,
P.O. Box 409148 Fenton MO 63026 6901 W. Sunrise Blvd.
314-349-0600 Ft. Lauderdale, FL 33313-409148 l
305-486-8606 l
General Kinematics Corp.
777 Lake Zurich Road Could, Inc.
Barrington, IL 60010 Computer Systems Div.
312-381-2240 30 Could Center l
Rolling Meadows, IL 60008 Attnt David A. Parmer General Motor Corp.
No Phone Truck Operation j
Truck & Bus Group 2210 Chouteau Ave.
Geuld, Inc.
j St. Leuis, M0 63103 Recording Systems Div.
314-577-5450 244 Cross Keys Shopping Center Florissant, M0 f 3033 314-921-3444 j
Glasco Electric Co.
706 N. Jefferson Avenue St. Louis, MO 63101 Gould, Inc.
l 314-231-2222 Measurement Systems Div.
i File 9699
)
Los Angeles, CA 90074 Michael D. Glascock No Phone J
Research Park I
University of Missouri Columbia, MO 65211 Could, Inc.
f 314-882-4211 TMSD l
432 Windsor Park Dr.
Dayton, OH 45459 314-921-3444
<,1
_ - - ~
Attachmsnt 4 Gould, Inc.
BCS I
Computer Systems Div.
GPE Controls P.O. Box 9148 6511 Oakton Street i
j Ft. Lauderdale, FL 33310-9148 Horton Gove, IL 60053 1
305-587-2900 312-967-0696 l
)
Gould, Inc.
Graver Water Division TMSD Graver Company l
40 Could Center 2720 U.S. liighway 22 Rolling Meadows, IL 50008 Union, NJ 07083 i
312-640-4380 201-964-2400 1
Gould Inc.
Graybar Electric Company i
Computer Systems P.O. Box 1467 Plaza 1 Office Bldg.
2708 Industrial Drive Suite 121 Jefferson City, MO 65102 502 Earth City Expvay 314-636-5135 i
Earth City, MO 63045 j
314-291-6989 Graybar Electric Co., Inc.
l l
P.O. Box 376 Could, Inc.
Main Post Office l
Programmable Control Div.
St. Louis, MO 63166 24 Keewaydin Dr.
314-531-4700
[
[
Salem, NH 03079 j
No Phone f
j Great Central Lumber Co.
L P.O. Box 595
[
l Gould, Inc.
Hwy. 54 & 63 Junction l
I Programmable Control Div.
Jefferson City, MO 65102
[
l 14323 South outer Rd.
314-635-7161
}
Suite 484 I
)
Chesterfield, MO 63017 i
314-576-3933 Grinnell Corp.
l 155 Westminster St.
l Providence, RI 02903 l
l Could Inc.
401-831-7000 Conputer Services Div.
i 2010 Algonquin Road f
)
Schaumburg, IL 60195 Grinnell Corp.
i No Phone 1615 S. Kingshighway
)
St. Louis, MO 63110 l
314-771-4925
(
J. D. Could j
i P.O. Box 18128 i
3 Indianapolis. IN 46218 Gulfalloy Inc.
f j
No Phene P.O. Box 52518 Houston, TX 77052 713-672-7451 i
Could Pumps. Inc.
1 1034 S. Brentwood Blvd.
l Suite 376 l
f St. Louis, M0 63117-1203 314-862-7867
. gg.
I 1
1
e H. K. Porter Co., Inc.
Handling Systems, Inc.
Electrical Division 9920 Watson Road P.O.. Box 8277 Crestwood, MO 63126 Shawnee Mission, KS 66208 965-8064 913-381-9070 R. H. Harper R. H. Harper 1344 Wilton Lane l
1344 Wilton Lane Kirkwood, MO 63122 Kirkwood, MO 63122 314-821-7094 7
314-821-7094 i
Harvey's Standard Service HJJ Conpany 1407 Avanue H P.O. Box 905 Ft. Madison, IA 52627 i
Los Catos, CA 95030 No Phone 408-395-4040 l
Hayward Tyler. Inc.
I Hach Company P.O. Box 492 l
P.O. Box 389 Burlington, VT 05402 Loveland, CO 80539 802-655-4444 i
800-227-4224 Henry Pratt Hagen Mitchell Van DeVanter Engineering Company. Inc.
1507 Woodson Road 1617 Manufactures Dr.
c St. Louis, MO 63114 Fenton, MO 63026 i
314-997-1793 314-343-8880 l
1
(
l Melville B. Hall, Inc.
Herbert Products, Inc.
3001 Spruce Street 180 Linden Avenue. P.O. Box 384 St. Louis, MO 63103 Westbury, NY 11590-0384 314-371-7000 516-334-6500 I
Hammel Dahl & Jamesbury Controls Company Hewitt Robins. Inc.
I 175 Post Road Robins Div.
Warwick, RI 02888 P.O. Box 1481 401-781-6200 Columbia, SC 29202 803-788-1424 Hammond Distributing 119 Cass Avenue Wemco St. Louis, MO 63102 P.O. Box 80709 314-241-5922 St. Clair Shores, MN 48080-0709 313-777-4200 Handley Industries 2101 Brooklyn Road Hindley Mfg. Company, Inc.
Jackson, MI 49203 9 Haven Street 517-787-8821 Cumberland, RI 02864 401-722-2550 Atttchmsnt 4 4
[
l i
Holo-Krome Company Hughes Brothers Inc.
P.O. Box H R R Kinyon Co.
i j
West Hartford, CT 06110 9216 Clayton Road 203-523-5235 St. Louis, MO 63124 314-993-4348 i;
l Honeywell Inc.
i Industrial Services Div Hughes Customat. Inc.
j 1
!!00 Virginia Dr.
1236 North & South Road l
Fort Washington, PA 19034 St. Louis, M0 63130 l
1 800-223-8947 No Phone Honeywell, Inc.
Hughes Micon Commercial Division Hughes Tool Co. Div.
{
2055 Craigshire Dr.
P.O. Box 1758 St. Louis, No 63141 Corsuana, TX 75110 1
314-576-2594 214-872-5681 l
I Honeyws11 Inc.
Hughes MPD l
Building Services Division P.O. Box 7428 f
11842 Borman Dr.
Houston, TX 77008 St. Louis, MO 63141 No Phone l
314-569-5433 Hydro Products Honeywell Inc. PMSD A Tetra Tech Company Process Mgmt. Syn. Div.
Honeywell Subsidiary
[
2250 W. Peoria Ave.
P.O. Box 2528 Phoenix, AZ 85029 San Diego, CA 92112-9965 l
602-863-5000 619-453-2345 i
Honeyw11 Incorporated Hydromatic Pumps l
Test Instrument Div.
5800 Foxridge Drive 14350 Proton Road Mission, KS 66202 I
Dallas, TX 75234 913-831-5700 l
214-387-5331 l
Hayward Cordon Ltd.
l Honeywell Incorporated 7485 Bath Road Process Control Div.
Malton Mississauga 6131 Corporate Dr.
Ontario, Canada L4T IL3 j
Houston, TX 77036 j
800-535-8356 Illinois Tool Works Inc.
1111 tron Div, i
ETB, Inc.
3601 W. Tonky Avenue
{
2146 Flintstone Drive Chicago, IL 60645 f
Tucker, GA 30084 312-761-2100 404-934-3101
)
20
[
i l
Industrial Process Equipment Company Interface Corp.
l j
2800 Locust St.
Lapp Insulator Div.
l St. Louis, MO 63103 Electrorep Inc.
i 314-534-3100 83 Weldon Parkway i
j Maryland Heights, MO 63043 l
314-991-2600 j
Custom Compactors Corp.
8100 E. Broadway l
P.O. Box 50434 Inventory Sales
]
Tampa, FL 33675 3140 Park Ave.
4 813-626-2188 St. Louis, MO 63104 314-776-6200 i
Industrial Measurement Co. Inc.
l 163 Chesterfield Ind. Bd.
ITE Electrical Products Company Chesterfield, MO 63017 1111-T Plaza Dr.
314-532-6910 Schaumburg IL 60195
.1 312-519-4300 e
Ingersoll Rand Company Pump and Compression Service Div.
ITT Barton 1
20602 E 81st Street C M Tilley Co., Inc.
l Broken Arrow, OK 74014 742 Goddard Ave.
j 800-346-8100 Chesterfield, MO 63017 i
314-537-2800 l
i Ingersoll Rand Company P.O. Box 1916 ITT Barton
[
)
Piscatavay, NJ 09854 Industrial Sales i
1 201-981-9100 349 W. 195th Street Glenwood: IL 60425 1
312-756-1472 Ingersoll hand Company l
j Parts Order Entry l
125 Tubevay ITT ceneral control Carol Stream IL 60188 801 Allen Avenue 800-526-3569 Glendale, CA 91201 l
818-842-6131 1
I
)
Ingersoll Rand Repair Center l
1 1515 Page Ind. Blvd.
ITT Engineered Valves J
St. Louis, Mo 63132 Corva Corp.
{
314-429-5200 149 Weldon Parkway j
Maryland Heights, MO 63043 1
314-567-1220 International Harvester Company Fleet Sales Office l
1050 South Highway Dr.
ITT Engineered Valves Fenton, M0 63026 33 Centerville Road 314-343-6800 P.O. Box 6164 4
Lancaster, PA 17603-2064 717-291-1901 J
1 1
., - -, - -,. ~ =, - -. -..,., - -, _ ~ --- -
,.-e-.-.
-.-,.w..
,..---n.-
Attachmsnt 4 I
)
I ITT Grinnell Valve Company John Fluke Mfg. Co., Inc.
33-T Centerville Road 1150 W. Euclid Lancaster, PA Palatine. IL 60067 f
717-291-1901 312-705-0500 i
l 1
j J C Industrial Johnson Controls P.O. Box 535 2188 Welsch Ind. Ct.
706 Virginia Street St. Louis. H0 63146-4291 Jefferson City, MO 65102 314-569-1570 j
314-636-4171 I
i I
l Johnny Jones Welding L
j John Henry Foster Company 447 Windsor Spring Drive i
j 10740 Midwest Ind. Blvd.
Kirkwood, MO 63122 L
j St. Louis. Ho 63132 314-965-0535 t
j 314-427-0600 1
j Joslyn Corp.
l 1
J. E. Lonergan Company P.O. Box 368 l
)
10050 Sandmeyer Lane 9200 W. Fullerton Avenue j
Philadelphia, PA 19116 Franklin Park, IL 60131 l
d 215-677-1710 800-323-0742 i
Jamesbury Corporation Joslyn Corp.
l i
640 Lincoln Street Joslyn Hi Voltage Equipment Div.
P.O. Box 664 4000 East 116th Street Worchester, MA 01613-0664 Cleveland, OH 44105 2
617-852-0200 216-271-6600 l
Jay Instrument and Specialty Co.
Joy Technologies Inc.
l 555 N. Wayne Avenue 3101 Broadway l
Cincinnati, OH 45215 Buffalo, bY 14225 513-733-5215
{
f Joy Technologies. Inc.
(
j J. D. Ind'astrial Pla. tics, Inc.
338 South Broadway
[
P.O. Box 1. Dept. TR P.O. Box 431 Whitehouce, NJ 08888 New Philadelphia OH 44663 l
l 201-534-2100 216-339-1111 i
1 l
{
Jerguson Gage 6 Valve Company KAR Products. Inc.
15 Adams Street 461 N. Third Street j
Burlington, MA 01803 P.O. Box 2414 l
i 617-272-3600 Des Plaines IL 60016 j
312-296-6111 I
3 i
Jervis L. Webb Company l
I 34203 Webb Drive Kaysing Iron Works Farmington !! ills, MI 493J1-5624 2701 No. 25th St.
313-553-1000 St. Louis, MO 63106 314-231-2050 1 l
1
Attachmsnt 4 Kearney Division of Kansas Gas & Electric Company i
Kearny Na uoual Inc.
P.O. Box 208 Electrorep, Inc.
Wichita, KS 67201 83 Weldon Parkway No Phone Maryland lleights, M0 63043 I
314-991-2600 Kansas Gas 6 Electric Company P.O. Box 309 Kedman Company 6 North & 5 East of Burlington Box 2566-T Buritngton, KS 66839 Salt Lake City, UT 84125 316-364-8831 801-973-9112 Lacrosse Lumber Company Kelsey Hayes Company P.O. Box 500 Tabco Division Fulton, MO 65251 1249 67th Street 314-642-3305
[
P.O. Box 8276 l
Oakland, CA 9466 415-658-7070 Labadie Automotive Route 1. Box 202B Labadie, MO 63055 Keystone Aniline Corp.
No Phone P.O. Box 88105 Chicago, IL 60680-1105 800-621-4529 Lapp Insulator Company Electrorep. Inc.
83 Weldon Parkway Midland-Ross Corp.
Maryland Heights, MO 63043 Electrical Products Div.
314-991-2600 8150 Perry Hwy., Suite 332 P.O. Box 1548 Pittsburgh, PA 15230 Leeds & Northrup Instruments 412-323-5400 Corporate Hills #1 l
Suite 210 1655 Des Peres Road j
Kinney Vacuum Company St. Louis, MO 63131 i
495 Turnpike Street 314-965-9200 Canton, MA 02021 l
617-828-9500 Levin & Son Inc.
15120 Desman Road l
Koppers Co., Inc.
La111rada, CA 90638 i
commercial Roofing Dept.
714-521-9191 188 Industrial Dr.
Elmhurst, IL 60126 No Phone Limitorque Corporation 8700 Monrovia Suite 320 Kris Kor Tool Products Lenexa, KS 6L215 6414 Hampton Ave.
913-492-7800 Suite 7 i
St. Louis, MO 63109 314-353-0940 l
Attachmsnt 4 I
i I
5 i
i Limitorque Corporation Masonellan Dresser 5114 Woodall Road Dress Valve & Controls Lynchburg, VA 24506 North American OPE 804-528-4400 Dresser Industries I
j 85 Bodwell Street i
Avon, MA 02322 Lincoln Electric Company 617-586-4600 i
1625 Sublette Ave.
l
)
St. Louis, MO 63110 d
314-647-5886 Masoneilan A D Michel Co.
2505 Metro Blvd. Ste. C 4
Lombardos Maryland Heights, MO 63043 83 Produce Row 314-567-5670 St. Louis, MO 63102 i
Master Appliance Corporation
)
Lone Star Screw Company P.O. Box 68 j
5826 Armour Drive Racine, WI 53401 1
P.O. Box 15211 No Phone t
Houston, TX 77020 l
~
713-675-5281 1
Master Protection Enterprises 2
i 435 Forbes Blvd.
J, Lord Corp.
South San F*ancisco, CA 94080
[
1635 W. 12th Street 415-952-6677 I
j Erie, PA 16512 i
i 814-456-8511 McGraw Edison Company j
Electric Machinery Div.
Lunkenheimer Coepany Electrorep Inc.
[
Beckman St. and Waverly Avenue 83 Weldon Parkway i
I P.O. Box 145487 Marylev Heights, MO 63043 l
l Cincinnati, OH 45214-5487 314-991-2600 i
1 513-921-3400 j
Mobile Equipment Corporation
[
j Mack Electric Company 7301 Galveston Road I
i 9832 Reavis Road Houston, TX 77034 l
l St. Louis, MO 63123 713-947-1870 j
314-638-7000 4
}
j McCoy Sales Company l
j Marcal Rope 6 Rigging. Inc.
P.O. Box 2111 j
100 Central Avenue Kansas City, KS 66110 i
P.O. Box 477 913-342-4904 l
d Alton, IL 62002 6
]
355-0287 1
McLean Midwest l
4000 83rd Avenue North l
Marco Screv Products Brooklyn Park, MN 55443 I
l 1978 Congressional Drive No Phone I
{
St. Louis, MO 63141 I
1 314-432-6505 l
l
- 2r -
l I
Attachesnt 4 Meredith Corporation Mine Safety Appl. Company P V N Steel 2053 Congressional Drive 460 Hillside Avenue West Plains Ind. Park Hillside. NJ 07205 St. Louis. NO 63146 2014964-5300 314-872-9331 Metal Goods Mine Safety Appliance 8800 Page Blvd.
P11ter Prod. Div.
St. Louis MO 63114 P.O. Box 429 314-427-1234 Pittsburgh, PA 15230 412-273-5000 Metro East Industrial Supply. Inc.
P.O. Box 578 MISCO Hwy. 162 & State Aide 35 P.O. Box 399 Granite City. IL 62040 One Misco Plaza 314-421-3145 Holmdel. NJ 07733 800-631-2227 Meyer Electric. Inc.
P.O. Box 1013 Missouri Illinois Tractor &
Jefferson City. Mo 65102 Equipment Company. Inc.
314-893-2335 155 & Rte. K P.O. Box 639 Cape Girardeau. MO 63701 Mid-American Metals. Inc.
314-334-5252 4199 Chippewa St. Louis. MO 63116 314-773-6353 Missouri Illinois Tractor &
Equipment Company 5920 N. Lindbergh Mid States Supply of Kansas. Inc.
Hazelwood. MO 63042 P.O. Box 192 314-731-1330 Wichita. ES 67201 316-265-6261 Missouri Illinois Tractor &
Equipment Company. Inc.
Roland Machinery Company P.O. Box 1348 Midway Equipment Div.
Columbia. MO 65202 2380 Cassens Drive 314-443-1441 Penton, MO 63026 314-343-7000 MOOG Corporation Industrial Division Miltons Garage East Aurora. NY 14052 Highway 47 North 716-652-2000 Warrenton MO 63383 314-456-3344 Moped Company R. R. Kinyon Company 9216 Clayton Road St. Louis. MO 63124 314-993-4348.
Attechssnt 4 l
l l
Morris Industries. Inc.
NATCO Fasteners Inc.
1823 Washington Street
!!688 Fairgrove Industries St. Louis, MO 63103 Maryland Heights, MO 63043 l
No Phone 314-567-3400 l
t I
Mosler, Inc.
National Meter Parts 445 Sovereign Ct.
240 Baldwin Drive Manchester, MO 63011 P.O. Box 908 r
l i
314-256 9800 Lancaster, OH 43130 i
614-653-8828 Mosler Inc.
1401 Vilson Blvd.
National Sales Company Arlington, VA 22209 4201 Duncan Avenue i
St. Leuis, MO 63110-1190 F
314-531-3200 Geo A. Mueller Company l
3033 Clearlake i
Springfield IL 62702 The National Torch Tip Co., Inc.
l 50 Freeport Road i
Pittsburgh PA 15215 Hueller Plumbing & Heating 412-781-4200
[
Hwy. 67 and Rosener Road Flat River, MO 63601 i
314-431-4044 Nelson Electric l
N J Associates, Inc.
l 3214 S. Big Bend Blvd.
i Municipal Tool and Mach.
St. Louis, MO 6314) i 2465 Rock Island Blvd.
314-645-2622 Maryland Heights, MO 63043 i
314-994-9905 l
Nelson Hardware & Auto Repair l
P.O. Box 116
)
Nagle Pumps. Inc.
Nelson, MO 65347 l
Paul Demay & Associates 816-859-2410 17536 Chesterfield Airport Road f
Chesterfield, MO 63017 Nuclear Power outfitter i
314-532-0505 Div. Personnel Protect I
P.O. Box 737 Crystal Lake IL 60014 NAPA Auto Parts 815-455-3777 525 S. Jefferson Avenue i
St. Louis, MO 63103 314-533-0243 Glen O'Brien l
Partition Co., Inc.
{
11677 Adie Road i
Nash Engineering Company Maryland Heights, MA 63043 97 Progress Parkway 314-432-1185
{
Maryland Heights, MO 63043 314-878-8363 i
i '
f
m.-__
_ _ _ _ _ _ _ ~
Attechment 4 t
I I
i
[
Ohio Brass Company Packard Instruments l
Customer Service Group 2200 Warrensville Road J
P.O. Box 1001 Downers Grove. IL 60515 Wadsworth. OH 44281 312-969-6000 f
i 800-523-7736
{
Emhant Corporation
{
4 Chelsea Industries USM Corporation j
2555 Metro Blvd.
Parker-Kalon Div.
Maryland Heights. MO 63043 395 Roberts Road 4
I 314-997-7709 Campbellsv111e. KY 42718 502-465-3521 k
i.
f Oz-Arc / Gas Equip. & Supply. Inc.
[
l 1533 Independent Avenue Patterson Pumps Cape Girardeau, MO 63701 Digital Systems Sales. Inc.
}
]j P.O. Box 961 t
j New Albany. IN 47150 J
j Harnisch Pager Corp.
812-948-5134 I
i P&H American Monoral 3839 County Road 116 J
j Hamel. MN 55340 Peerless Mfg. Company j
6120478-6337 Flo con L
j 321 Hanley Ind. Ct.
[
St. Louis, MO 63144 I
1 P. W. Southern. Inc.
314-645-1316 i
Cordon Karraker 300 :tansion House Ctr.
3 Suite 1817 Peerless Pump Company St. Louis, MO 63102 8050 Watson Road 314-231-3666 St. Louis. MO 63119 314-842-4424 l
i I
P. W. Western. Inc.
l P.O. Box 1399 Peerless Pump Company Monte Bello, CA 90640-0120 Ulmer Equipment Company l
1554 Tenpark Drive l
Fenton. Ho 63026 i
Pacifte Pumps 314-343-4606 Dresser Industries. Inc.
3201 Wolf Road Franklin Park. IL 60131 Perkin-Elmer Corporatis2 312-455-8210 10805 Sunset Office Dr.
St. Louis. MO 63127 j
314-821-5921 1
Mark Controls Corporation i
Pacific Valves 3201 Walnut Porter Cable Corporation Long Beach. CA 90807 7574 Watson Road 800-421-3779 St. Louis HO 63.119 314-968-8950
.I :
3 i
i Attach:: ant 4 i
f i
l l
l I
l Power Conversion Prod.
Pulsa Feeder 42 East St.
M C Fridley Company f
g Crystal Lake. IL 60014 612 Cepi Drive 4
j 815-459-9100 Chesterfield MO 63017 i
314-537-2030 i
i Price Bros Independent Concrete Pipe Company Pyle National Div.
I 12950 Cravois Avenue BR Intec Corp.
}
St. Louis. Mo 63126 1334 N. Kostner Avenue 4
314-842-2909 Chicago IL 60651-1697 312-342-6300 1
l Price Waterhouse t
One Centerre Plata Rice Equipment Company j
St. Louis, MO 63101 9620 Midland j
1 St. Louis MO 63114
)
314-427-7900 t
]
Keystone Valve-USA
[
j 9700 W. Gulf Bank Dr.
t 1
Box 40010 R T & E Corporation j
Houston. TX 77040 1456 Westbrook Meadows Lane l
i 713-466-1176 Manchester. MO 63021 l
314-225-8789 l
Enhant Corporation f
l USM Corporation R T 6 E Deltec Corporation l
Parker-Kalon Div.
2727 Kurtz Street 395 Roberts Road San Diego CA 92110 i
Campbellsville. KY 42716 619-291-4211 l
502-465-3521
)
I REC Corporation l
)
Pro Quip Inc.
Ten Beach St.
l l
P.O. Box 165 Mt. Vernon. NY 10550 Macedon. OH 44056-0165 914-699-6000 l
i 216-468-1850 l
j R P Adams Company. Inc.
{
Product Componints Corporation Carl F. Gast Company l
1 30 Lorraine Ave.
930 N. McKnight Road l
]
Mount Vernon, NY 10553 St. Louis. MO 63132 i
1 914-699-8640 314-993-2870 l
l l
l j
Production Tool & Supply Co.
Radeco Division of Science j
620 Shenandoah Avenue Applications. Inc.
St. Louis, MO 63104 10373 Roselle Street i
314-773-3030 San Diego CA 92121 619-458-3831
]
P S L Energy Services Inc.
P.O. Box 937 Windsor. CT C6095 203-242-3087 l
I...
Attachusnt 4 4
l 1
,1 I
i Telemecanique Inc.
Rockwell 2002 Bethel Road Telecommunications /kTPD i
Westminster. HD 21157 8245 S. Lemont Road 1
301-876-2214 Downers Crove, IL 60516 i
312-985-9000 l
Reco Industries. Inc.
P.O. Box 147 Rosemount Inc.
)
West Columbia, SC 29169 3401 Ho11enberg Drive I
803-794-3360 Bridgeton, MO 63044
(
j 314-739-1540 l
j
- {
Robert Irsay Company. Inc.
l f
8130 N. St. Louis Ave.
Ros er.ount Inc.
i Skokie, IL 60016 P.O. Box 35129 i
312-583-2525 Minneapolis, MN 35435-0129 l
1 612-941-5560 j
l j
Reliance Automotive Service, Inc.
i l
490 N. Kingshighway Rosemount Inc.
l j
St. Louis, MO 63108
.2001 West 78th Street l
1 314-367-8485 Eden Prairie, MN 55344 512-941-5560 Riback Supply Company 4
2412 Business Loop 70E Rosemount, Inc.
5 Columbia NO 65205 Controls Systems Div.
314-875-3131 1300 E. Lambert Road La Habra, CA 90632-700' l
213-690-7117 l
Riley Stoker Corporation f
l Rhodes Equipment Company
(
8704 Manchester Road Rubelmann-Lucas. Inc.
[
St. Louis, MO 63144 10800 Midwest Ind. Blvd.
314-962-8820 St. Louis, MO 63132 l
314-426-1616 i
f Rockford-Eclipse Div. of Eclipse Inc.
Sanders Welding Supply i
1665 Elewood Road 938 St. Louis Ave.
j Rockford, IL 61103 Valley Park, MO 63083 l
815-877-3031 314-335-1096 I
l 1
l Rockwell Sears-Vestal Cospany
)
Municipal & L'tility Div.
702 Hanley Ind. Ct.
)
1996 L'niversity Lane St. Louis. NO 63144 1
Draver 1050 913-492-7800 i
Lisel. IL 60532 l
312-852-0026 l
Security Firt, Door j
P.O. Box 7389
[
St. Louis, MO 63177 l
314-533-5700 l
l
! )
i
Attachmsnt 4
[
Service Supply Company Sky Climber. Inc.
3715 Pennridge Drive 1501 Rock Mountain Blvd.
Bridgeton, MO 63044 Stone Mountain, GA 30083 l
314-739-7769 404-939-770$
l l
i Sha11better. Inc.
SLIGO, Inc.
[
R. E. Kennedy Co., Inc.
P.O. Box 171 225 Old Meremac Sta. Rd.
St. Louis, MO 63166 Manchester. MO 63011 314-231-3050 l
314-391-8840 i
Snap on Tools Corp.
Shepard Niles Crane & Holst Corp.
4156 Shoreline Drive 250 Cenesee St.
P.O. Box 838 Montour Talls, NY 14865 Bridgeton. MO 63044 I
607-535-7111 314-291-3020 Shipping Utilities. Inc.
Southern Parts & Engineering Co.
i 10539 Liberty Ave.
5879C New Peachtree Road St. Louis, Mo 63132 Atlanta, CA 30340 l
314-426-4800 800-241-5690 l
1 Sidener Supply Company Specici T Metals Co., Inc.
601 Big Bear Blvd.
8425 Mid County Ind. Dr.
Columbia MO 65202 St. Louis. MO 63114 314-442-4450 314-426-2225 I
Sidener Supply Company Spence Engineering Co.
f P.O. Box 1309 Control Products. Inc.
(
45 Northgate Ind. Drive 1668 Headland Dr.
l Granite City. IL 62040 Tenton. MO 63026 314-621-0747 314-343-9501 Steplex. Inc.
Sprague Meter Div. of 1139 N. Macarthur Blvd.
Sangamo Weston, Inc.
j Springfield. IL 62702 35 South Avenue 800-637-8603 Bridgeport. CT 06601-2141 203-382-8005 S K T Industries. Inc.
7750 Clayton Road A. R. Stanley Co.
Suite 304 1200 East "B" Str.
St. Louis, MO 63117 Belleville. IL 62221 314-647-3444 314-233-0109 SKIL Corporation Stanley Sales. Inc.
1238 S. Vandeventer Avenue P.O. Box 514 St. Louis. MO 63110 St. Louis. MO 63042 314-535-7424 314-731-2994 I
}
j f
1 Star Expansion Company Southwestern Engireering Coepany i
l 108 Greystone P.O. Box 54940
)
Kansas City KS 66103 Terminal Annex 913-281-3360 Los Angeles. CA 90054 j
213-726-0641 l
4 J
Sterling Industrial Corporation P.O. Box 538 Target Rock Corporation l
Wilkes Barre. PA 18703 P.O. Box V l
717-822-3104 1966E Broad Hollow Road l
1 East Farmingdale. NY 11735 l
516-293-3800 l
Steel City Bolt
{
Ken Way Company Suite A Robert Taylor & Assoc.
8 The Pines Ct.
1006) Manchester Road r
St. Louis, MO 63141 St. Louis. H0 63122 j
314.469-9998 314-821-3228 l
1 r
a l
I Stock Equipment Company Taylor & Taylor l
12015 Manchester Road 3030 North Heridan St. Louis, MO 63131 Wichita. KS 67204 f
314-966-5685 316-838-4932 r
'1 I
I l
j Stock Equipment Conpany Jim Taylor Inc.
l 1
16490 Chillicothe Road 1127 East B Street j
Chagrin Falls. OH 44022 P.O. Box 564 216-543-6000 Belleville. IL 62222 j
No Phone i
I Structural Systems. Inc.
816 S. Kirkvood Road Taylor Industrial Tools Kirkwood MO 63122 10434 Lackland Road l
314-966-5920 overland. MO 63114 l
g 314-428-4242 r
4 Superior Supply Company j
1405 Illinois Technical Products 1
Columbia. MO 65201 1712 Bia Bend Blvd.
l 314 449-0806 St. Louis. MO 63117
]
No Phone j
1 Superior Fastener Co.. Inc.
)
8525 Vulcan Teleflex Inc.
)
St. Louis. MO 63111-3891 P.O. Box 218 l
314-638-6500 Church Road l
North Wales. PA 19454 215-699-4861
]
Sligo. Inc.
140 E. Prairie Avenue St. Louis, MO 63147 I
314-231-7283
! 1 l
i c
Attachsont 4 i
)
l
+
i
(
0 Terex Corp.
TRW f
5405 Darron Road. Rt. 91 Nelson Division
{
Hudson. OH 44236 C600 West 95th Street i
216-650-5000 Overland Park. XS 66212 l
913-381-3060
{
Texas Bolt Company l
P.O. Box 1211 IRC Incorporated j
Houston. TX 77001 Diviuion of TRW f
713-669-7111 P.O. Box 91195 Drawer 19007 Chicago, IL 60693 Thoren Industries. Inc.
No Phone P.O. Box 586
{
Hazelton. PA 18201-0586 f
No Phone TRW Cornunications Group
(
2212 Welsch Industrial Court i
St. Louis, MO 63146 t
i John N. Thorp Co., Inc.
No Phone f
85 Industrial Ave.
l Little Terry. NJ 07643 4i 201-641-2130 TRW Tastener Divison i
10544 West Lunt Avenue I
Rosemont. IL 60018 l
Tiemann Ind. Hdvs.
312-296-7192 i
P.O. Box 14406 St. Louis. HO 63178 314-531-1212 United Conveyor Corporation Hesler Coepnay j
P.O. Box 8207 j
j Eaton Corp.
Prairie Village. KS 66208 l
Engineered Tasteners Div.
314-454-0215 P.O. Box 6686 Cleveland. OH 44101-1688 i
216-523-5361 Unistrut Midwest
]
1545 Atlantic St.
North Kansas City. MO 64116
[
Tools & Supplies. Inc.
816-842-2043 i
11600 Adie Road d
Maryland Heights. H0 $3043 l
314-569-0009 Unistrut Service Co.
i 2722 Mercantile Dr.
St. Louis, MO 63144 f
Tractor Vestronics Inc.
314-647-4344 l
P.O. Box 961003 i
Tort Worth. TX 76161-9985 l
817-625-2311 United Controls Measurement Inc.
t P.O. Box 2409
)
TRW Chino C?. 91708 Welson Stud Velding Div.
714-628-1034 11710 Administration Dr.
I Suite #5 St. Louis, Mo 63141 314-567-5320 L l
.I
Attachmint 4 4
United States Steel Corporation Vermeer Sales & Service MI/Inc.
120 S. Central Ave.
P.O. Boy. 273 St. Louis, MO 63105 Chesterfield Airport Road 314-726 ~'00 Chesterfield, MO 63017 314-532-2332 UE
- Cyc,
' ales Victoria Products P.O.
3693 Forest Park Valle J 63088 St. Louis, MO 63108 314-21 314-652-2500 U S Steel Supply Div.
Viking Fire Protection Company U S Steel Corporation 499 Northgate 311 Scath Sarah Street Wheeling, IL 60090 St. Louis, MO 63110 312-459-6800 314-658-0200 Leroy L. Wade 6 Son, Inc.
Utilities Service Company 10550 I Street George DuBoise Compnay Omaha, NE 68127 2405 Hollyhead Dr.
No Phone St. Louis, MO 63131 314-963-4790 Wagner Elevator Service, Inc.
P.O. Box 902 Valcor Engineering Corp.
Burlington, IA 52601 2 Lawrence Road No Phone Springfield, NJ 07081 201-467-8400 Wallace & Tiernan Sales Corp.
P.O. Box 875 Vanton Pump and Equipment Corp.
Shawnee Mission, KS 66201 Westfell Co., Inc.
913-384-3933 232 Axminister Drive Fenton, MO 63026 314-343-5855 Wallace 6 Tiernan Div.
Tenwalt Corporation 25 Main Street Vanton Pump and Equipment Corp.
Belleville, NJ 07109 201 Sweetland Avenue 201-759-8000 liillside, NJ 07205 201-688-4218 Waterman & Waterman Creve Coeur Executive Velan Valve Corp.
Office Park 2125 Ward Avenue 745 Craig Road, Suite 300 Montreal Quebec, Canada H4M IT6 St. Louis, MO 63141 314-432-6709 Velan Valve Corp.
Griswold Industrial Park Williston, VT 05495 No Phone 1 -
I
Attachmant 4 4
Dana Corporation Westinghouse Electric Corporation Weatherhead Div.
Combustion Control Div.
1480 Ford Street 1201 North Main Street Maumee, OH 43537 P.O. Box 901 419-891-2040 Orrv111e, OH 44667 216-682-9010 Mueller Pump Commerce & Exchange Westinghouse NSID P.O. Box 1364 Fpartanburg Service Ctr.
Conway, AR 72032 F.O. Box 2110 501-329-9811 Spartanburg, SC 29304 803-599-0110 Weksler Instruments Corporation 80 Mill Road Westinghouse Electric Box 3040 Instrument Service Company Freeport, NY 11520 750 Trumbull Drive 516-623-0100 Pittsburgh, PA 15205-4399 412-276-0650 WEMCO Lark Engr. Corp.
Weatinghouse Electric Corporation 6 Bopp Lane Productos Westinghouse Inc.
St. Louis, MO 63131 GPO Box 71455 314-432-1300 San Juan, Puerto Rico 00936 No Phone WESCO 2820 Market Street Westinghouse Electric Corporation St. Louis, MO 63103 Elevator Division 314-533-4250 9475 Dielman Rock Island Drive St. Louis, M0 63132 314-991-5232 Weldstar Company P.O. Box 711 i
Aurora, IL 60507 Westinghouse Electric Semiconductor Division Youngwood, PA 15697 Westinghouse 412-925-7272 i
Engineering Services 2060 Craigshire Road St. Louis, M0 63146 Westinghouse Electric Corporation 314-776-2344 Instrument Service 18418 S. Wentworth Lansing, IL 60438 Westinghouse Electric Corporation 312-895-4111 Industry Electronic Division P.O. Box 2958 Shawnee Mission, KS 66201 Westinghouse Electric Corporation 913-451-6544 1905 Bernice Road Lansing, MI 60438 312-454-7125 j
Attachmsnt 4 t
Whiting Corporation Weksler Instruments Corporation 8029 Rosiline Drive 80 Mill Road St. Louis, MO 63105 Box 3040 314-741-6880 Freeport, NY 11520 516-623-0100 Whittet-Higgins Company 33 Higginson Avenue W. M. Powell Company P.O. Box 8 2503 Spring Grove Avenue Central Falls, RI 02863 Cincinnati, OH 45214-1771 401-728-0700 513-852-2000 Williams & Company Worthington Leasing P.O. Box 1320 Bick Corporation Louisville, KY 40203 9333 Dielman Industrial 502-582-3321 St. Louis, MO 63132 314-993-3355 Geo E. Williams Mfg. Company P.O. Box 32257 Dresser Pump Division Minneapolis, MN 55432 Dresser Industries, Inc.
612-784-7346 6901 W. 63rd Street Overland Park, KS 66202 314-569-1800 Williams Key Co., Inc.,
2206 Locust Street St. Louis, M0 63103 Yale Matetials Handling 314-231-4143 Gammon, Inc.
1960 Concourse Drive St. Louis, MO 63146 Williams Sales & Service 314-567-9250 7th & Frankford Road Louisiana, MO 63353 No Phone Yarnells DX Station Jct. 5 6 52 West Versailles, MO 65084 Oscar Wilson Engine & Parts, Inc.
314-378-4600 4159 Shoreline Drive Earth City, MO 63045 314-739-131)
Yarway Corporation Blue Bell, PA 19422 215-825-2100 H. F. Wilson ingr. Company P.O. Box 2938 Clen Ellyn, IL 60138 York Division 314-291-5555 Borg Warner Corporation 11645 Northline Ind.
haryland Heights, MO 63043
)
S M Wilson & Company 314-567-5687 j
2025 S. Brentwood Blvd.
P.O. Box 6873 St. Louis, MO 63144 No Phone.
Attachmsnt 4 e
.~
s Zurn Industries Mechanical Drives Division 1801 Pittsburgh Ave.
Erie, PA 16512 814-455-0921 Zurn Industries A. L. Martin & Co., Inc.
P.O. Box 1467 Belleville, IL 62223 314-569-7075 a
i i
j t