t APR D Docket No. 99900905/83-01 Wyle Laboratories Western Operations ATTN: Mr. R. C. Sadlier General Manager 1841 Hillside Avenue Norco, CA 91760 Gentlemen:
This refers to the inspection conducted by Mr. J. R. Agee of this office on January 17-20, 1983, of your facility at Norco, California, associated with the environmental qualification testing of nuclear safety-related equipment and to the discussions of our findings with you and members of your staff at the conclusion of the inspection.
Areas examined and our' findings are discussed in the enclosed report. Within these areas, the inspection cons,isted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.
During the inspection it was found that the implementation of your QA program failed to meet certain NRC requirements. The specific findings and references to the pertinent requirements are identified in the enclosures to this letter.
This Notice of Violation is sent to you pursuant to the provisions of Section 206 of the Energy Reorganization Act of 1974. Normally you would be required to submit to this office within 30-days from the date of this letter, a written statement describing your corrective actions and preventive measures.
However, during the inspection, you completed the posting of Section 206 of the Energy Reorganization Act of 1974 and committed to add this item to your audit checklist. Therefore, we censider your corrective action to be complete and no written response to this finding is necessary.
You are requested to submit a written statement for each item which appears in the enclosed Notice of Nonconformance. The response should be submitted to us within 30 days from the date of this letter containing:
(1) a description of steps that have been or will be taken to correct these items; (2) a description of steps tha.t have been or will be taken to prevent recurrence; and (3) the date your corrective actions and preventive measures were or will be completed.
Consideration may be given to extending your response time for good cause shown.
k RIV CI:EQS M SC:EQS BC:VPB D:D
()
JRAgee/jkh HSPhillips UPotapovs RLB frt f//Y/83
(//f/83 4/@/83
/j /83 8305050251 830421 PDR GA999 EXIWYLE 99900905 pop e
Wyle Laboratories Western Operations The responses requested by this letter are not subject to the clearance procedures of the Office of Management and Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.
In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room.
If this report contains any information that you believe to be exempt from disclosure under 10 CFR 9.5(a)(4), it is necessary that you (a) notify this office by telephone within 10 days from the date of this letter of your intention to file a request for withholding; and (b) submit within 25 days from the date of this letter a written application to this office to withhold such information.
If your receipt of this letter has been delayed such that less than 7 days are available for your review,~ please notify this office promptly.so that a new due date may be established. Consistent with Section 2.790(b)(1), any such application must be accompanied by an affidavit executed by the owner of the information which identifies the document or part sought to be withheld, and which contains.a full statement of the reasons on the basis which it is claimed that the information should be withheld from public disclosure. This section further requires the statement to address with specificity the considerations listed in-10 CFR 2.790(b)(4). The information sought to be withheld shall be incorporated as far as possible into a separate part of the affidavit.
If we do not hear from you in this regard within the specified periods noted above, the report will be placed in the Public Document Room.
Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely, acri$d #
U. POTAPCfiU Uldis Potapovs, Chief Vendor Program Branch
Enclosures:
1.
Appendix A - Notice of Violation 2.
Appendix B - Notice of Nonconformance 3.
Appendix C - Inspection Report No. 99900905/83-01 4.
Appendix D - Inspection Data Sheets (7 pages)
Wyle Laboratories Western Operations bcc:
JTCollins, RIV RLBangart, RIV JEGagliardo, RIV 4
EHJohnson, RIV MIS Section (J. Perry)
VPB Branch Chief VPB Section Chiefs VPB Inspector DMB-IE:09 NBB&PVI SDRichardson, 0IE-DRP RFHeishman, 0IE-RCB VSNoonan,NRR-EQB WSFarmer, RES LDBustard, Sandia National Laboratories, Albuquerque, NM
.