Forwards Addl Info to Support 830216 Request That HN-100, Series 2 Casks Be Included in Renewal of Certificate of Compliance 9079.Rev 6 to Cask Handling Procedure for HN-100,Series 2 & Series 3.... Encl
ML20151H473
Person / Time
Site: 07109079
Issue date: 04/06/1983
From: Mallory C
HITTMAN NUCLEAR & DEVELOPMENT CORP. (SUBS. OF HITTMAN
To: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
Shared Package
ML20151H466 List:
References
22159, NUDOCS 8305040159
Download: ML20151H473 (3)


Text

{{#Wiki_filter:Hittm:n 0l) L$ a h Nucl.or0 ia o.v.iopm.nt A West.nghouse Euc Subedary Corporation 9151 Rumsey Road Columbia, Maryland 21045 Refer to: HN-E712 7/ /s F J PR April 6,_1983 , wwss ~ Mr. Charles MacDonald, Chief g Transportation Certification Branch RECElVED.

  • U.S. Nuclear Regulatory Commission Washington, D. C.

20555 9-gpR 7 1983 > ~it .Nu of Subj ect: HNDC Model HN-100 Series 2 co Y Radioactive Materials Package NMSS ff uan secum Certificate of Compliance No. '9079 Cv

Dear Mr. MacDonald:

Reference is made to'our letter of February 16, 1983, which requested that ~ the HNDC HN-100 Series 2 casks be included in the renewal of Certificate of Compliance No. 9079 and the consolidated application submitted by Nuclear Packaging, Inc., on November 24, 1983. Our letter submitted information -requested by your letter of January 7, 1983, as.it relates to the HN-100 Series 2 casks. f. Attachment A contains additional information requested by your staff. (Telecon Charles Williams to C. Mallory of April 4, 1983) and eight copies of _ the revised drawings which incorporate this information. Attachment B is attached for your information and is the latest revision of the Cask Handling Procedure which has been revised to ' cover the use of the alignment marks currently on the cask. If you have any questions or require additional information, please contact me. Very truly yours, x - laf' aLU grles W. al}o rp-- Isirector, Engineering g e A g lh occKETED e,. Attachments USNRC g I APR 181983 > b f4; R h ~ a i g,_ERK DOCKET CL 2 in, l f, h' ,7p 3 ~ c. OM/ f 8305040159 830425 PDR ADOCK 07109079 C PDR

r D b ATTACHMENT A Radioactive Materials Package HNDC Model HN-100 Series 2 Certificate of Compliance No. 9079 Responses to Nuclear Regulatory Commission Verbal Comments of April 4, 1983 A. DRAWINGS The current drawings for the HNDC HN-100 Series 2 radioactive waste shipping cask are Hittman Nuclear & Development Corporation Drawing Nos.: C001-5-9122, Rev. 3 C001-5-9123, Rev. 3 C001-5-9124, Rev. 2 The following changes have been made in the drawings previously submitted. 1. Drawing Number C001-5-9122, Rev. 3 a. The List of bbterials has been revised as follows: o The materials for Item 19 are specified to be ASTM A320 Gr. L-7 or SAE Gr. 5. Section B contains the analysis to show the adequacy of SAE Gr. 5 material as a substitute for ASTM A320 Gr. L-7. Item 14 will be ASTM A194 Gr. 4 or Gr. 7 and "or equal" o has been removed. The "or equal" materials option, has been removed from o Item 6, Ratchet Binder, i o The "or equal" materials option has been removed from Item i 18, 3/4"-10 UNC stud. b. The weld designations have been added for the attachment of the spacer rings, Item 23, to the primary lid, Item 2 and to the cask body, Item 10. c. The alignment marks on the shield plug, primary cover and cask body have been shown on the drawings. The marks are currently on the cask and are used when the alignment pins are damaged. Attachment B is a copy of the Cask Handling Procedure which has been revised to include the use of the alignment marks. 1

O h Page 2 ATTACHMENT A April 6, 1983 2. Drawing Number C001-5-9123, Rev. 3 a. Note 1 has been revised to show the December 18, 1980 date for the use of ASTM A516 Gr. 70 steel to be consistent with the Certificate of Compliance. b. The dates in Notes 8 and 9 have been revised to be consistent with Note 1. B. SUPPORTING ANALYSIS The calculations to show the adequacy of fasteners, Item 19, constructed of SAE Gr. 5 steel are as follows: 1. Purpose : to show adequacy of SAE Gr.5 material for 1" diameter pins fastening ratchet binders to cask Item 19 on Dwg. C001-5-9122. 2.

References:

1) Safety Analysis Report for Nuclear Packaging, Inc. 14D-2.0 cask dated 11/29/83 and supplement dated 3/18/83. 2) 1971 SAE Handbook, Standard J429 3) 1978 Annual Book of ASTM Standards, Part 1. 3. Calculation: Per Ref. 2, minimum yield strength of SAE Gr. 5 = 85 KSI Per Ref. 3, minimum yield stregnth of ASTM A320 = 105 KSI Ref. 1, Page 2-26/2-27, Safety Factor with A320 = +0.61 Using SAE Gr 5 - Yield 85.000 psi = 0.6 (85,000) Shear = 51,000 psi = c = F capacity 0A = 2 (51,000 psi)(1.58 in ) = 80,580 lb F capacity = (80,580/61,669) -1 Therefore, Margin of Safety = + 0.30 =}}