'O1 liF111988 Docket No. 99990001 General Licensee EA:

88-46 Block Drug Company ATTN: David Schuman Associate Corporate Counsel 257 Cornelison Avenue Jersey City, New Jersey 07302 Gentlemen:

Subject:

Special Inspection No.

88-65 On February 18, 1988, Laurence F. Friedman, Ph.D., C.H.P. & Mr. Waymon Wallace of this office conducted t safety inspection at your Dayton, New Jersey facility of activities authorized by the above listed NRC license.

The inspection was limited to a review of your possession and use of static eliminato s manufactured by the Minnesota Mining and Manufacturing Company (3M).

The findings of the inspection were discussed with Mr. Victor Coots, Dayton Plant Manager at the conclusion of the inspection.

During this inspection, a survey of your Dayten, New Jersey f acility for polonium-210 contamination was performed.

The survey included both flocr creas and equipment. No contaminstion above acceptable levels was found.

Within the scope of tnis inspection, no violations were identified.

In accordance with Section 2.790 of the NRC's "Rules of Practice", Part 2, Title 10, Code of Federal Regulations, a copy of this letter will be placed in the Ptblic Document Room.

No reply to this letter is required.

Your coaperation with us is appreciated.

Sincerely, Ori ic ' if Dy:

fJohn s.M.ma John R. White, Chief Nuclear Materials Safety Section C Division of Radiation Safety and Safeguards cc:

Public Document Room (POR)

Nuclear Safety Information Center (NSIC)

State of New Jersey

.E:07 0FFICIAL RECORD COPY ML DL BLOCK DRUG - 0001.0.0

/[g 8804130369 800401 03/28/88 REG 1 OA999 Ef'tVBLOCK REl%h CEIGINA110 99990001 PDR ggy g

e

'01 APR 1988 Block Drug Company 2

bcc:

Region 1 Docket Room (w/ concurrences)

Management Assistant, ORMA S

RI:DRSS RI:

SS d55 F

d n/mlb' Wa ace e

3/ '/88

$/,y/88 Y 03/g/88 OFFICIAL]} RECORD COPY

(

ML DL BLOCK DRUG - 0002.0.0 03/28/88

________________u