,gr BOSTON EDISON Pilgnm Nuclear het Station Rocky Hill Road Pt mouth, Massachusetts 02360 y

Ralph G. Bird Senior Mce President - Nuclear March 29,1988 BECo Ltr. #88 061 U.S. Nuclear Regulatory Commission Attn:

Document Control Desk Hashington, DC 20555 Docket No. 50-293 License No. OPR-35

Dear Sir:

The enclosed table, "Number of Personnel and Han-Rem by Work and Job Function 1987",

is submitted in accordance with the requirements of the Pilgrim Nuclear Power Station Technical Specifications, Section 6.9.A.3, and as recommended by U.S. NRC Regulatory Guide 1.16.

The collective dose measured by TLD for Pilgrim Nuclear Power Station in calender year 1987 totaled 1578.609 man-rem.

The accumulated dose for station, utility and contractor personnel assigned to radiation work permits during 1987 totaled 1,344.853 man-rem.

Eighty-five percent (850 of the total station dose was accounted for via radiation work permits and assigned to specific major work functions.

Please do not hesitate to contact me directly if you have any questions.

,otA_ -

R.G.

ird BPL/bl Attachment cc:

Mr. Hilliam Russell Regional administrator, Regica I U.S. Nuclear Regulatory Commission 475 Allendale Rd.

King of Prussia, PA 19406 Sr. Resident Inspector - Pilgrim Station Standard BECo Distribution

)

8804110101 871231 PDR ADOCK 05000293 i

R pop f7371%/74 1

1987 STATISTICAL

SUMMARY

REPORT BOS10N EDISON COMPANY DOCKET NO.

50-293 PILGRIM NUCLEAR POWER STATION LICENSE NO. DPR-35 ESTIMATED HHOLE GODY

  1. OF INDIVIDUALS TLD EXPOSURE RANGE (REM)*

IN EACH RANGE DOSE (REM)

No Heasureable Dose 3,249

.000 Heasureable - <0.100 2,382 84.021 0.100 - <0.250 761 122.330 0.250 - <0,500 522 187.085 0.500 - <0.750 322 196.476 0.750 - <i.000 230 198.257 1.000 - <2.000 408 573.851 2.000 - <3.000 65 150.543 3.000 - <4.000 20 66.046 4.000 - <5.000 0

.000 5.000 - <6.000 0

.000 6.000 - <7.000 0

.000 7.000 - <8.000 0

.000 8.000 - <9.000 0

.000 9.000 - <10.000 0

.000 10.000 - <12.000 0

.000

>12.000 0

.000 Total Monitored 7,959 Total with Measureable 4,710 Collective Dose 1,578.609 s

' Individual values equal to the values separating exposure ranges are reported in the higher range.

4 i

l

.Y OI{!

I