. _

o o

=M P

Log # TXX-88295 C

File # 10110 Z

Z 903.7 7UELECTRIC Ref. # 10CrR50.55(e)

March 31, 1988

% miam G. Counsil Enrantu Vwe Presdens V. S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.C.

20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATI0fl (CPSES)

DOCKET NOS. 50-445 AllD 50-446 SEISMIC CATEGORY 11 SYSTEliS AND COMP 0flEilTS SDAR:

CP-86-45 (FiflAL REPORT)

Gentlemen:

On October 16, 1987, we notified ynu by our letter, logged TXX 6812, of a deficiency involving Seismic Category Il systems and components which we deemed reportable under the provisions of 10CFR50.55(e). Our latest report on this issue, logged TXX-88050, was submitted January 8, 1988.

This report is submitted to provide the corrective action completion schedule.

Unit 1 corrective actions are currently scheduled for completion by December 15, 1988.

The completion of the corresponding Unit 2 corrective actions will be prior to Unit 2 fuel load.

Very truly yours, h.b. b W. G. Counsil By:

D. R. Woodlan Docket Licensing Manger JOS/c1k c-lir. R. D. fiartin, Region IV Resident inspectors, CPSES (3) 880405(1027 880331 PDR ADOCK 05000445 i

g g S

DCD 400 North Ohve Street LB 81 Dallas. Texas 7H01

_... _ -,