ML20150D803

From kanterella
Jump to navigation Jump to search
Revised Application for Amend to License SNM-1168 to Accommodate Temporary Shutdown in Fuel Fabrication Activities in Summer 1988.Attachment I of 880531 Application Modified
ML20150D803
Person / Time
Site: 07001201
Issue date: 06/29/1988
From: Watters J
BABCOCK & WILCOX CO.
To: Rouse L
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
24467, NUDOCS 8807140149
Download: ML20150D803 (5)


Text

7 v.

4 pvrrmg.yo :.,.3_/!7 7$.go/.

~

@B&W MS P.O. Box 11646

^ " ^

%~6 chburg, VA 24506-1646 i ~

%yD(804 g

JUL 051988 ) 10 June 29, 1988 8

~

22-6000 RECEIVED v

~

= $$

ut sten 0N g

h 4

JUL091988 h b

t g U 3,MUCtIAR REGULATORY /'J 00 Wit $$N)N Mr. Leland C.

Rouse, Chief ass Fuel Cycle Safety Branch 4

E Division of Fuel Cycle, Medical, Academic, and A

u)

Commercial Use Safety United States Nuclear Regulatory Commission Washington, D.

C.

20555

References:

(1)

SNM-1168, Docket 70-1201 (2)

Letter from J. T.

Ford to R. G. Page, dated 1/28/83 (3)

Letter from J. T.

Ford to R.

G. Page, dated 2/22/83 (4)

Letter from J. P. Watters to i T. Crow, dated 3/6/87 (5)

Letter from J. P. Watters to L. C. Rouse, dated 5/31/88 Gentlemen:

The B&W Fuel Company, Commercial Nuclear Fuel Plant has requested amendment of SNM-1163 to accommodate a temporary shutdown in fuel fabricacion activities this summer (Reference 5).

This letter is written to modify Attachment I sent with the 5/31/88 letter.

V We had requested that Part 6.6 of Section V of SNM-1168 indicate a monthly instead of weekly audit schedule for nuclear and radiological safety, except during plant shutdown of a week or longer.

The exception for the week or longer plant shutdown is ambiguous in light of the fact that the overall. request is intended to apply to a 2-3 month shutdown period.

As a result, we have deleted the exception for the week or longer plant shutdown as indicated in the attachment to this letter.

All other requested conditionc remain unchanged, f0$

I l

880714014o 880629 PDR ADOCK 07001201

.1,/f 4 C

PDC LfTW' u

r:

~'

Y
'; e 4

y.

  • "\\Mr. L31cnd C.-Rouce u'.

Page 2 L

June 29,~1988 e.

Please call me at (804) 522-6202 if you-have questions about

-this. request.

Thank'you for-your prompt attention'to this request.

Sincerely, B&W FUEL COMPANY COMMERCIAL NUCLEAR FUEL PLANT J.

P. Watters

' License & Control Administrator JPWicmr.

Attachment i

r G

B&W FUEL COMPANY COMMERCIAL NUCLEAR FUEL PLANT SNM-ll68, JUNE 29, 1988 ATTACHMENT I We request a license conditiog, approving the following license exemptions and modifications for the shutdown period.

SNM-ll68 Section V Part 6.2 The calendar year 1988 retraining of radiation workers shall be conducted when the workers return to work after the end of the shutdown period.

6.6 Health-Safety personnel shall conduct, at least ceckly/ monthly, a formal audit of plant status relative to nuclear and radiological safety.

8.1.l(A)

Differential pressure shall be checked-weekly / quarterly and filters replaced when damage is evident, or when the differential pressure exceeds 4 inches of water.

8.1.l(B)

Gascous effluents shall be representative 1y sampled on a continuous basis, and when the facilities are in operational status, the samples shall be collected daily / weekly and counted after allowing for decay of radon and its daughters.

8.2.2 Exemption from performing weekly measurement of glovebox negative pressure, hood face velocities, and elephant trunk velocities.

8.2.3 Exemption from collecting daily samples at work stations and periodic lapel samples, t.

c

.)

<=

[* ' D&W!PbELCOMPANY COMMERCIAL-NUCLEAR, FUEL PLANT SNM-1168, JUNE'29,-1988 ATTACHMENT I SNM-1168 Section V Part

-Survey 8.4.5 Area Action Level Frequency 2

1. Controlled Removable:

5,000 DPM/100 cg

,,==g3yj,,

pellet Total 50,000 DPM/50 cm monthly fabrication /

rod. loading change room (hot area).

2. Change Room Removable:

500 DPM/100 cg d;ily/

(Inter-Total 2,000 DPM/50 cm weekly mediato) 2

3. Clean Removable:

200 DPM/100 cg

==__tg3yj,

(Remainder Total 500 DPM/50 cm not done of plant and office area) g,.

8.4.5 Tours shall be made according to our Security Plan.

~

SNM-1168 L

Section VI Need:

The CNFP Emergency Fesponso Organization shall remain intact during the planned shutdown.

However, the Emergency Team may need to be supplemented by NNFD and/or NNFD-RL Emergency Team personnel.

If this is necessary, the supple.nental Emergency Team personnel shall receive CNFP specific training and will be under the control of the Emergency Officer in the event their assistance is required.

Request:

We request approval of our plan to utilize NNFD and/or NNFD-RL Emergency Tean personnel to supplemelt the CNFP Emergency Team during this shutdown period.

';=

- b-/2b/

DOCKET NO.

Nddlo7 CONTROL NO.

t!.tlL_.b,fN DATE OF 000, DATE RCVD.

uL. S l 9 B f3 r

FCUF

/

PL:R FCAF LPDR I & E REF. _[_

sarEcuARos. '

FCTC 01HER _..

!bb IN'T ;L

b..

DATE I I

.,