ML20150C966

From kanterella
Jump to navigation Jump to search
Forwards Payment for 880620 Licensing Request Re Change to Certificate of Compliance 9019
ML20150C966
Person / Time
Site: 07109019
Issue date: 06/23/1988
From: Foleck R
GENERAL ELECTRIC CO.
To: Gerard Jackson
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML20150C961 List:
References
NUDOCS 8807130234
Download: ML20150C966 (1)


Text

. _ _ _

7

' GE Nuclear Energy

^ ~

~

- cews! nw< cwca, Cast 4 H3,n Pass. WJanTom NC 28407 June 2?, 1988 Ms. Glenda Jackson License Fee Management Branch, ARM U.S.N.R.C.

' Washington, DC 20555 Daar Ms. Jackson,

Reference:

NRC License SNS-1097, Docket #70-1113 Subj ect: Payment for 6/20/88 Licensing Request Re-Change to NRC Certificate i

of Compliance USA /9019/AF, BU-7 As required, enclosed is a GE check #162047 for $150 for the subject certificate change.

A copy of the submittal letter is enclosed for your reference.

If you have any questions regarding this matter, please contact me at (919) 675-5987.

Very truly yours, GE NUCLEAR ENERGY U

L R. H. D. Foleck, Sr. Specialist Licensing Engineering

?:

m

^

~

n N

,>}

Attachments'

%b '

C-4

.. s _, g,. g_ _,

m.,

quii GE Nuclear Energy w.,n a.,. u. v n Lyy H1,u h: V.h>yc. t,L ? % y s

June 20, 1988 Mr. Charles E. MacDonald, Chief Transportation Certification Branch Division of' Fuel Cycle & Material Safety U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Mr. MacDonald:

Subject:

NRC Certificate of Compliance USA /9019/AF

References:

  • ) Application from TP Winslow to CE MacDonald dated 1/6/86
2) Application from TP Winslow to CE MacDonald dated 2/7/86
3) Letter from CE MacDonald to TP Winslow dated 6/18/86
4) Letter from TP Winslow to CE MacDonald dated 7/11/86
5) Application from TP Winslow to CE MacDonald dated 12/22/86
6) Letter, CE MacDonald to TP Winslow, 2/24/87
7) Letter, TP Winslow to CE MacDonald, 3/24/87
8) Supplement, TP Winslow to CE MacDonald, 9/29/87
9) Letter, CE MacDonald to TP Winslow, 12/11/87
10) Letter, TP Winslow to CE MacDonald, 12/23/87
11) Letter, TP Winslow to CE MacDonald, 2/09/88 In our December 22, 1986 submittal, we requested a modification to Revision 13 of the subject certificate to allow an increased mass of UO, powder having not more than 0.45 H/U ratio at enrichments g: eater than 3.2 w/o U885 In making this change we inadvertently reduced the mass limit for enrichments of 3.2 w/o U8 8 5 and less.

This reduction was not necessary because our criticality safety demonstrations support the previous limits.

For both normal and accident conditions the information contained in the 12/22/86 Consolidated Application, Appendix D, demonstrates safety with up to 204 kgs UO, per container.

Per the table on page 2 of Appendix D of the Consolidated Application, the only demonstration affected by this change is demonstration 3, Single

w c.

i...m-.

m

., m

-- ~

Mr. Charles E. MacDonald June 20, 1988 Page 2 Container, for Conditions A and C.

For UO, powder at enrichments greater than 3.2 w/o U888 (Condition A) the criticality safety basis for a single container is provided in the Consolidated Application, Appendix C, Section 6.3.

For UO, powder at enrichments not greater than 3.2 w/o U818 (Condition A) and UO, pellets (condition C),

the criticality safety basis for a single container is provided in the Consolidated Application, Appendix E.

To correct this, we request that the certificate be changed to reflect the mass limits contained in certificate 9019, Revision 13, as they apply to the type and form of material described in Sections 5 (b) (1) (1) (for enrichments 3.2 w/o U888 and less) and 5 (b) (1) (111).

(Note:

For material described in 5 (b) (1) (1), at enrichments greater than 3.2 w/o U888, the maximum UO, per pail and package should remain 35.0 kgs and 70.0 kgs respectively as shown in Certificate 9019, Revison 14.)

The requested teording to Section 5(b) (2) and Section 6 for Certificate 9019, is as follows:

(2) Maximum quantity of material per package (i) For the conteurs described in 5 (b) (1) (1) :

The maximum contents per package and pail for the maximum U-235 enrichment shall be limited in accordance with the following table:

Maximum U-235 Maximum UO, Maximum UO, enrichment, per pail, per package, w/c kas kas 3.0 44.5 89.0 3.2 38.9 77.8 3.4 to 4.0 35.0 7^.0 (ii) For the contents described in 5 (b) (1) (11) :

The maximum contents of uranium oxide powder per package and pail shall be limited to 70 kgs and *5 kgs respectively.

(iii) For the contents described in 5 (b) (1) (111) :

The maximum contentc per package and pail for the maximum U-235 enrichment shall be limited in accordance with the following table:

7--

.. _ _.- m s.

_y, Mr Charles E. MacDonald June 20, 1988 Page 3 Maximum U-235 Maximum UO, Maximum U0, enrichment, per pail, per package, w/o kas kas 2.7 45.0 90.0 2.8 42.9 85.8 2.9 40.1 80.2 3.0 38.1 76.2 3.2 34.1 68.2 3.4 31.0 62.0 3.6 28.5 57.0 3.8 26.4 52.8 4.0 24.7 49.4 (6) For mixtures of contents (powders and pellets) described in 5 (b) (1), the maximum quantity of material per package shall be limited to the quantity given in 5 (b) (2) (iii). contains page changes to the 12/22/86 application.

These pages, numbers 4 and 5, are dated 6/20/88 to reflect this request.

We have an international powder shipment scheduled for the week of August 15, 1988 and consequently request your assistance to expedite the issuance of an NRC Certificate revision in sufficient time to obtain DOT Competent Authority approval before this date.

Please advise me if there is any information or action we can take to assist in meeting this objective.

We are also requesting a minor change to the BU-7 license drawing 112D1592, Revision 7, Note 6, affecting the nameplate so the.t non-specified regulatory information is not rpecifically called out.

Note 6 on drawing currently reads:

6.

Permanently mark by engraving, etching or metal stamp, using 1/2" (minimum) haracters, per 10 CFR 71.85(c), the following information.

General Electric Company Wilmington, NC, USA Model BU-7 USA /9019/AF Max Gross Weight 370 Lbs.

, -.. _.... -.< m umn ~. w.c m-----,-

...w 4

Mr... Charles E. MacDonald June 20, 1988 Page 4 Change Note 6 to read:

l l

6.

Permanently mark by engraving, etching or metal stamp, l

using 1/2" (minimum) characters, per 10 CPR 71.85(c).

I A copy of GE drawing 112D1592, Revision 8, with the requested change is enclosed as Attachment 2.

l L

A check for $150 to cover the cost of this request will be forwarded under a separate cover.

If you have any questions regarding this matter, please contact me.

Sincerely, GE NUCLEAR ENERGY

$.N

^'

T.

Preston Winslow, Manager Licensing & Nuclear Materials Management

/sbm Attachments W.--

_ _ _ _ _ _. _ _ _. _ _ _. _. _ _ _ _. _. _. _. _ _