. s
=
A 08 MAR HB p
i Docket No. 99990001 License No. General Licensee t
Westinghouse Electric Corporation ATTN: Mr. A. J. Nardi l
P.O. Box 355 Pittsburgh, Pennsylvania 15230 Gentlemen:
Subject:
AUTHORIZATION FOR TEMPORARY CONTINUED USE OF 3M P0-210 STATIC ELIMINATION DEVICES In accordance with your facsimile dated March 1, 1988 and as provided in Section III., Paragraph C. of Order Modifying General License dated February 18, i
1988, you are hereby authorized to continue temporary use of 3M Po-210 static elimination devices now in your possession as described below:
3 M Model No No. of Devices Location of Use within Plant 2
i 210 2
Laminator at the Insulating Materials Division in Bedford, i
Pennsylvania 210 1
Vertical tower #20 at the Insulating Materials Division
)
in Bedford, Pennsylvania This authorization expires May 31, 1988, and is contingent upon your performing (or having performed) the folicwing:
l 1.
Leak tests of each 3M device at intervals not to exceed 30 days.
If leakage is detected, a report shall be made as required by 10 CFR ~,1.5(c)(5);
2.
Contamination surveys of areas surrounding the 3M device at intervals not to exceed 30 days.
If contamination in excess of 1000 dpm/100 square cm 4
is detected, a report shall be filed as if leakage hao been detected in
]
excess of 0.005 microcuries; l
3.
If compressed air is used with a 3'i device, checks of compressed air lines to ensure absence of water, oil, or other foreign material at intervals 4;
not to exceed 30 days.
1 This authorization does not permit you to receive new or replacement static eliminators from 3M.
R80316o164 eS0305 0FFICIAL RECORD COPY WEC 9999001 - 0001.0.0
,9o$999ENVWEST 03/04/88 A
Ell b
98 MAR 1B8 If you have any questions, please contact John Glenn at (215) 337-5260.
Sincerely, Or ciac.1 Signed Dy i
\\;ILLI!., T. P.USSZLL William T. Russell Regional Administrator cc:
M. Lamastra, NMSS/IMA8 Minnesota Mining and Manufacturing Company ATTN:
Mr. Robert G. Wissink 3M Center 220-2E-02 St. Paul, Minnesota 55101-1000 bcc:
Region I Docket Room (w/ concurrences)
J. Allan, DRA T. Martin, DRSS J. White, DRSS J. Joyner, DRSS
^
/
kRI:
Q;@JJGlenn RI:DRSS
. RSS RSS
,JJoyner F. Congel 3/f/87 3/4 /87 3/y/87 RL RI:DRA JA an WTRussell 3/}/87 3/4/87 0FFICIAL RECORD COPY WEC 9999001 - 0002.0.0 03/04/88 E.18