Authorizes Continued Temporary Use of 3M Po-210 Static Elimination Devices Contingent on Complying W/Listed Items, Including Leak Tests of Each 3M Device at Intervals Not to Exceed 30 Days & Submitting Repts If Leakage Detected
ML20150B095
Person / Time
Issue date: 03/08/1988
From: Russell W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Nardi A
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
Shared Package
ML20150B097 List:
References
REF-QA-99990001-880308 NUDOCS 8803160164
Download: ML20150B095 (2)


Text

, - -. - - - -

. s

=

A 08 MAR HB p

i Docket No. 99990001 License No. General Licensee t

Westinghouse Electric Corporation ATTN: Mr. A. J. Nardi l

P.O. Box 355 Pittsburgh, Pennsylvania 15230 Gentlemen:

Subject:

AUTHORIZATION FOR TEMPORARY CONTINUED USE OF 3M P0-210 STATIC ELIMINATION DEVICES In accordance with your facsimile dated March 1, 1988 and as provided in Section III., Paragraph C. of Order Modifying General License dated February 18, i

1988, you are hereby authorized to continue temporary use of 3M Po-210 static elimination devices now in your possession as described below:

3 M Model No No. of Devices Location of Use within Plant 2

i 210 2

Laminator at the Insulating Materials Division in Bedford, i

Pennsylvania 210 1

Vertical tower #20 at the Insulating Materials Division

)

in Bedford, Pennsylvania This authorization expires May 31, 1988, and is contingent upon your performing (or having performed) the folicwing:

l 1.

Leak tests of each 3M device at intervals not to exceed 30 days.

If leakage is detected, a report shall be made as required by 10 CFR ~,1.5(c)(5);

2.

Contamination surveys of areas surrounding the 3M device at intervals not to exceed 30 days.

If contamination in excess of 1000 dpm/100 square cm 4

is detected, a report shall be filed as if leakage hao been detected in

]

excess of 0.005 microcuries; l

3.

If compressed air is used with a 3'i device, checks of compressed air lines to ensure absence of water, oil, or other foreign material at intervals 4;

not to exceed 30 days.

1 This authorization does not permit you to receive new or replacement static eliminators from 3M.

R80316o164 eS0305 0FFICIAL RECORD COPY WEC 9999001 - 0001.0.0

,9o$999ENVWEST 03/04/88 A

Ell b

98 MAR 1B8 If you have any questions, please contact John Glenn at (215) 337-5260.

Sincerely, Or ciac.1 Signed Dy i

\\;ILLI!., T. P.USSZLL William T. Russell Regional Administrator cc:

M. Lamastra, NMSS/IMA8 Minnesota Mining and Manufacturing Company ATTN:

Mr. Robert G. Wissink 3M Center 220-2E-02 St. Paul, Minnesota 55101-1000 bcc:

Region I Docket Room (w/ concurrences)

J. Allan, DRA T. Martin, DRSS J. White, DRSS J. Joyner, DRSS

^

/

kRI:

Q;@JJGlenn RI:DRSS

. RSS RSS

,JJoyner F. Congel 3/f/87 3/4 /87 3/y/87 RL RI:DRA JA an WTRussell 3/}/87 3/4/87 0FFICIAL RECORD COPY WEC 9999001 - 0002.0.0 03/04/88 E.18