Forwards Revised Inservice Plant Insp & Testing Program,For Review & Approval.Rev Incorporates NRC Questions & Comments on Program Received During 871021-22 Meetings.Fee Paid
ML20149N111
Person / Time
Site: Hatch  
Issue date: 02/24/1988
From: Gucwa L
GEORGIA POWER CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML20149N112 List:
References
SL-4032C, NUDOCS 8803010272
Download: ML20149N111 (2)


Text

.

,1 W

ny:

  • ~

u.E Atta is s t 545 Atlanta, Georgia 30302 Georgia Power L. T. Gucwa me whyn W2c system

~ Manager Nuclear Sa'ety and Ocensing.

SL-4032c 1951C X7GJ17-H790 February 24, 1988

.U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Hashington, D. C.

20555 PLANT HATCH - UNITS 1, 2 NRC DOCKETS 50-321, 50-366 OPERATING LICENSES DPR-57, NPF-5 REVISED INSERVICE INSPECTION AND TESTING PROGRAM FOR PLANT HATCH Gentlemen:

Georgia Power Company (GPC) hereby submits the revised ~ Inservice-Inspection Testing (ISI/IST) Program for Plant Hatch Units 1 and 2 for your review and approval.

Our last revision was submitted, by letter i

dated September 11, 1987 mainly to reflect NRC comments on Plant Hatch's ISI Program for the second 10 year interval.

These NRC comments were included in the Safety Evaluation Report (SER) transmitted by letter dated Septerrber 24,-

1986.

This revision (Enclosure 1),

however, incorporates NRC questions and comments on plant Hatch's IST program received during our meeting with the NRC on October 21-22, 1987.

As you are aware, detailed notes were compileri during this meeting and formally transmitted to GPC with the reference NRC letter dated November 12, t

1987.

The enclosed revision incorporates the questions and comments from this letter.

Except for a minor editvrial change (correcting weld identification numbers in Section 2.1.7),

the ISI portion of the submittal is identical.with the September 11, 1987 submittal.

Georgia Power Company requests that the NRC review arid approve the revised program document for Plant Hatch Units 1 and 2.

In order to

. facilitate an orderly incorporation of this revision of our IST program, GPC requests a time period of nine (9) months after receipt of the SER to have completed the revision of all procedures other than those requiring 3

.validatior, during a maintenance / refueling outage.

Procedures which must be validated during an outage will be completed by the end of the upcoming Unit 1 (1988) and Unit 2 (1989) maintenance / refueling outages, providing of course, that GPC receives an SER prior to the Unit 1 outage, g0C I

10 W l] hetN 5

00

'8803010272 880224

^

0 il4 (fog f'il FDR ADOCK 05000321

,o DCD

v

[

GeorgiaPower1 1

U. S. Nuclear Regulatory Commission r

February 24, 1988 Page Two E

I lin (10) copies of the updated ISI/IST document are provided.

Also, pursuhrit to the requirements of 10 CFR 170, GPC encloses a check for the applisation fee of $150.00 for the review of the ISI/IST document.

i If you have any questions in this regard, please contact this office at any time.

5 Sincerely, ff&

F L

L. T. Gucwa EO GKH/lc L

Enclosure:

1.

Inservice Inspectim. Program Second 10-Year Interval -

y f

E. I. Hatch Nuclear Plant Units 1 and 2 2.

Filing Fee - $150.00 m

I

References:

Letter, L. P. Crocker to J. P. O'Reilly, "Inservice Testing

[

Program - Hatch Units 1 and 2", dated November 12, 1987.

I 6

c: Georgia Power Comoany P

Hr. J. T. Beckham, Jr., Vice President - Plant Hatch L

GO-NORMS b

U. S. Nuclear r g u l a to ry Commi r s i qam_Hi? h i n a ton. D. _ C.

e Mr. L. P. Crc.Ker, Licensing Project Har ager - Hatch U..S Nuclear Reaulatory Commission. Region II r

L Dr. J. N. Grate, Regional Administrator Mr. P. Holmes-Ray, Serior Resident Inspector - Hatch 3

=

k-I 1951C

,