I R,
February.18, 1988 s.
Project No. 669 Mr. Edwin E. Kintner, Chairman ALWR Utility Stee;ing Comittee GPU Nuclear Corporation 100 Interpace Parkway.
Parsippany, New Jersey 07054
Dear Mr. Xintner:
SUBJECT:
ALWR UTILITY REQUIREMENTS DOCUMENT - CHAPTER 2 REVIEW The staff has completed its review of Chapter 2 of EPRI's Advanced Light. Water Reactor (ALWR) Utility Requirements Document. Enclosed are several copies of our Draft Safety Evaluation Report (DSER) which documents the review.
Based on its review, the staff concluded that the utility requirements in Chapter 2 are in general agreement with NRC guidelines and regulatory requirements for the power generation systems involved. This finding is based, in part, on the commitments in your letters of March 27, 1987 and September 17, 1987 to make certain changes in Chapters 1 and 2.
9 Also enclosed is a revised copy of our DSER for Chapter 1.
The only significant change is on pages 4-10 and 4-10a, which 3rovides clarification of the staff's position relative to the leak-before-brea< issue.
If there are any questions relative to the DSER, please direct them to Paul H.
Leech on (301) 492-1103.
Sincerely,
$ b " h M b s Nin, Director Standardization and Non-Power Reactor Project Directorate Division of Reactor Projects - III, IV, Y and Special Projects Office of Nuclear Reactor Regulation
Enclosure:
As stated cc:
J. C. DeVine, Jr., EPRI DISTRIBUTION:
[Centralf11e;l Pleech FMiraglia CMcCracken/XParczewski NRC PDR LRubenstein LShao JJoyce/JStewart PDSNP Reading OGC-White Flint TXing, RES XWichman/JTsao C
DCrutchfield TMurley JRichardson DTondi/JLazevnick rh4 EHylton JSniezek JWerme11/DShum PTXuo/MHartzman y,iB AThada i RJones/GSchwerk ACRS-(Alderman) 15
'W P
PDSNP h P
. [
02/[1on E
Pleech:cw L'
n
/88 02/l0/88 8802250401 880218 6
A PDR
f 1
i i
[
jo,,
UNITED STATES 8
NUCLEAR REGULATORY COMMISSION n
- E WASHINGTON, D, C. 20555 g
%, * *. *,o#
February 18, 1988 Project No. 669 Mr. Edwin E. Kintner, Chairman ALWR Utility Steering Comittee GPJJ Nuclear Corporation 100 Interpace Parkway Parsippany, New Jersey 07054
Dear Mr. Kintner:
SUBJECT:
ALWR UTILITY REQUIREMENTS DOCUMENT - CHAPTER 2 REVIEW The staff has completed its review of Chapter 2 of EPRI's Advanced Light Water Reactor (ALWR) Utility Requirements Document. Enclosed are several copies of our Draft Safety Evaiuation Report (DSER) which documents the review.
Based on its review, the staff concluded that the utility requirements in Chapter 2 are in general agreement with NRC guidelines and regulatory requirements for the power generation systems involved. This finding is based, in part, on the comitments in your letters of March 27, 1987 and September 17, 1987 to make certain changes in Chapters 1 and 2.
Also enclosed is a revised copy of our DSER for Chapter 1.
The only significant change is on pages 4-10 and 4-10a, which provides clarification of the staff's position relative to the leak-before-break issue.
If there are any questions relative to the DSER, please direct them to Paul H.
Leech on (301) 492-1103.
Sincerely, t-7rs Lester S. Rubenstein, Director Standardization and Non-Power Reactor Project Directorate Division of Reactor Projects - III, IV, Y and Special Projects Office of Nuclear Reactor Regulation l
Enclosure:
As stated cc:
J. C. DeVine, Jr., EPRI i
i
~... - -,.