Corrected Application for Amend to License SNM-1097,revising Section 1.8.14,inadvertently Omitted in 960904 Submittal
ML20149L760
Person / Time
Site: 07001113
Issue date: 10/31/1996
From:
GENERAL ELECTRIC CO.
To:
Shared Package
ML20149L754 List:
References
NUDOCS 9611180012
Download: ML20149L760 (2)


Text

- _ _

e 1.8.14 Transfer of Calcium Fluoride (CaF ) Test Quantities 2

Authorization to transfer test quantities of CaF2 to potential buyers for the purpose of their examination and evaluation as described in NF&CM's letter dated 9/24/92.

Test quantities may not contain more than 30 pCi per gram 235 on a dry weight basis and limited to 1 gram U at each off-site location.

Test activities and end use of the material will be limited to those that do not allow chemical separation of the uranium or entry of the product into the food chain.

i 1

1.8.15 Authorized Air Sampling Adjustments Authorization to adjust Derived Air Concentration (DAC) limits and Annual Limit of Intake (ALI) values in process areas to reflect actual physical characteristics of the airborne uranium in accordance with written operating l

procedures.

GE-Wilmington site specific information on characteristics of airborne uranium shall be documented in internal records.

For those areas in which adjusted ALI/DACs are applied, controls are established to limit soluble uranium intakes using air sampling and urinalysis.

4 Assigned air adjustments will not be made to ALI/DACs for operations, locations or incidents where the airborne uranium physical characteristics are not documented.

9611190012 961031 PDR ADOCK 07001113 C

PM LICENSE SNM-1097 DATE 09/04/96 Page DOCKET 70-1113 REVISION 54 I-1.20(a)

CORRECTED

o i

' )

,r Established airborne uranium limits in each area that adjusted ALI/DACs are used pursuant to the above f

authorization shall be reassessed by the Radiation Safety function at one quarter of the work locations at 6-month f

intervals, selecting different locations each time.

If the reassessed limit (ALI) has changed by more than 30% from the previously established limit for an area, the limit for that area shall either be re-established or i

replaced wP ' a default value based upon 1 micron AMAD.

In additivn, a reassessment shall be performed following process or equipment changes likely to affect the airborne particle size distribution.

1.8.16 Transfer of Hydrofluoric Acid (HF) For Testing i

Authorization to transfer test quantities of HF to 4

potential buyers / customers or laboratories for the purpose of analyzing, examination or evaluation, without continuing NRC controls as described in our letter dated

)

2/27/96.

Test quantities may not contain more than 3 PPM uranium with an enrichment not to exceed 6% U235.

The recipients will be advised that this material is not 1

~

a nuclear hazard, but will be advised that the material should be handled carefully and in such a manner so as not to be consumed by humans nor used in products used on or in the body or in the food chain.

i LICENSE SNM-1997 DATE 09/04/96 Page DOCKET 70-1113 REVISION 54 1-1.20 (b)

CORRECTED s