June 1997 The reactor operated continuously in June with the following exceptions: five shutdowns for scheduled ma ntenance and refueling; one unscheduled shutdown, l

i l

On June 30, a spurious wide range monitor (N.I. Channel #4) high power rod run-in occurred

.i during a startup for a low-power e cperiment. The reactor power level was 10 kW at the time this occurred. No actual high power indication was observed on any instrumentation. Electronics technicians rescated connections and insulated the cover from the component housing inside the i

Channel #4 picoammeter. The instrument was tested satisfactorily and a startup was completed with no further problems of this type occurring.

Major maintenance items for the month included preparing depleted pool deionization bed "R" i

for disposal and loading new pool deionization bed "Y".

UNSCIIEDULED SIIUTDOWNS Daic h

Tymn Cnuse 6/30/97 1065 Rod Run-In Spurious Channel #4 high power OPERATION

SUMMARY

IIOURS OPERATED TIIIS PERIOD 649 TOTAL HOURS OPERATED 204,802 HOURS AT FULL POWER TIIIS PERIOD 646 TOTAL llOURS AT FULL POWER 201,741 INTEGRATED POWER tills PERIOD 269 MWD TOTAL INTEGRATED POWEl?

78,209 MWD MAINTENANCE ACTIVITIES 06/02/97 Refueled - removed core 97-24, loaded core 97-25.

06/05/97 Dumped depleted pool DI bed "R", loaded new pool DI bed "Y".

06/09/97 Refueled - removed core 97-25, loaded core 97-26.

06/16/97 Refueled - removed core 97-26, loaded core 97-27.

06/23/97 Refueled - removed core 97-27, loaded core 97-28. Performed biennial facility / emergency support personnel emergency drill.

06/30/97 Refueled - removed core 97-28, loaded core 97-29.

t