k 4.-

PETEa E. KATz Baltimore Gas and Electric Company Calvert Cliffs Nuclear Power Plant Plant General Manager Calveri Cliffs Nuclear Power Plant 1650 Calvert Cliffs Parkway Lusby, Maryland 20657 410 495-4101

{

I I

February 15,1996

)

U. S. Nuclear Regulatory Commission Washington, DC 20555

{

ATTENTION:

Document Control Desk

SUBJECT:

Calvert Cliffs Nuclear Power Plant J

l Unit Nos.1 & 2; Docket Nos. 50-317 & 50-318 l

Annual R.eport of Failures and Challenges to Power-Operated Relief Valves and Safety Valves for the Period of January 1.1995 through December 31.1995 This report is submitted in accordance with Technical Specification 6.9.1.5.c. The Technical Specification requires an annual report be submitted to the Nuclear Regulatory Commission documenting all challenges l

to, and failures of, the pressurizer power-operated relief valves and safety valves. There were no challenges or failures of the pressurizer power-operated relief valves or safety valves on either Unit during 1995.

Should you have questions regarding this matter, we will be pleased to discuss them with you.

I Very truly yours,

'/

U'- {}

C/ DL PEK/RCG/bjd d

cc:

D. A. Brune, Esquire J. E. Silberg, Esquire L. B. Marsh, NRC D. G. Mcdonald, Jr., NRC T. T. Martin, NRC Resident Inspector, NRC R. I. McLean, DNR J. H. Walter, PSC h

l g

9602220283 960215

\\g PDR ADOCK 05000317 PDR P