NPDES Noncompliance Notification:On 970713,pH of Discharge Canal (Dsn 001-1) Went Above 9.0 Limit.Caused by Algae Blooms in CT River & Low Flow to Discharge Canal.Continue to Notify in Writing of Any Future High Ph Excursions
ML20149K109
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 07/18/1997
From: Scace S
CONNECTICUT YANKEE ATOMIC POWER CO., NORTHEAST NUCLEAR ENERGY CO.
To: Dinoia M
CONNECTICUT, STATE OF
References
D11317, SES-97-GN-113, NUDOCS 9707290253
Download: ML20149K109 (26)


Text

,

, N:rtheast 1 7 seiaen simo nean, n037 Utilities System sonhe i etaitie. senice comp.ny P.O. Box 270 1Iartford, CT 06141-0270 July 18,1997 (860) 66sso0 Dll317 Oc,def $6'd/3 SES-97-GN-113 Ms. Michele DiNoia Department of Environmental Protection 79 Elm Street Hartford, CT 06106-5127 Connecticut Yankee Atomic Power Company Hiuh Discharge Canal nH i

Dear Ms. DiNoia:

On the afternoon of July 13,1997, the pH of the discharge canal (DSN 001-1) went above the 9.0 limit. This pH excursion is attributed to algae blooms in the Connecticut River and low flow to the discharge canal. This phenomenon occurs periodically during hot, sunny weather. The pH of the discharge canal fluctuated above and below 9.0 for approximately three hours before stabilizing below the limit. No batch discharges were occurring at the time of the excursion, and only a low volume of once-through coolmg water was being discharged.

A voice mail message was left at your office concerning this occurrence on the morning ofJuly 14,1997. We expect that, if weather conditions remain the same, there may be additional pH excursions in the near future. As discussed with you, Connecticut Yankee will report any future high pH excursions attributed to algae blooms in writing on a weekly basis.

1 Should you have any questions concerning this matter, please contact Mr. Paul 4

Brindamour, Connecticut Yankee Environmental Coordinator at (860) 267-3510.

Sincerely, CONNECTICUT YANKEE ATOMIC POWER COMPANY ra ce/

S. E. ScEce

\\

r)

Director - Nuclear Engineering Programs

],b, J

p j

l cc:

NRC NRC Resident inspector James Grier, Connecticut DEP

{ O,3 p t, G b b bffllf]lfllflfjfll 970729025? 970718 PDR ADOCK 05 2

S

1

\\

North 6ast i 7 8d'" 8'""' ""w 6037 d'

Utilities System

.wrtheet Utuides senice compan 4

  • F P.O. Box 270 Ilartford. CT 06141-0270 i

(860) 665-5000 July 18,1997

[oc/,t 99O SES-97-GN-110 4

l D11291 j

Mr. Edward D. Finger Compliance inspector Department of Environmental Protection 70 Elm Street Hartford, CT 06106-5127 Dear Mr. Finger.

Connecticut Yankee Atomic Power Company July 23.1997 Compliance inspection Follow-up i

a i

During your June 23,1997 inspection at Connecticut Yankee Atomic Power Company (CYAPCO), an oil and grease sample result for DSN 001-E was found by you to have been taken as a " grab sample" rather than as a " grab sample average" as set forth in CYAPCO's NPDES permit. At your request, CYAPCO has investigated its sampling and analysis of " grab sample averages" and hereby submits the following information.

A review of records for the previous twelve months for all discharge parameters requiring grab sample averages (Oil & Grease, DSN 001-B and DSN 001-E) indicate that for short duration batch discharges, grab samples were occasionally taken instead of grab sample averages (see attached data summaries). However, sample parameter concentrations were reported in the DMR correctly.

Corrective actions have already been taken to modify the sample log sheets to clearly indicate that grab sample averages require a minimum of two samples, regardless of i

the discharge duration. CYAPCO will also be modifying its NPDES sampling program to include the use of sampling data sheets as discussed during the exit interview. When implemented, Chemistry Department personnel responsible for NPDES sampling will be required to read and sign a document describing this change.

Should you have any questions, please call Mr. Paul Brindamour, CYAPCO Site Environmental Coordinator at (860) 267-3510.

oc.mrun

O Mr. Edward D. Finger D11291/SES-97-GN-110/Page 2 July 18,1997 Sincerely, CONNECTICUT YANKEE ATOMIC POWER COMPANY t

/_' ( U C '

l

~

S. D. Scace Director-Nuclear Engineering Programs cc:

James Grier, Connecticut DEP NRC NRC Resident inspector i

1 l

Mr. Edward D. Finger D11291/SES-97-GN-110/ Attachment A July 18,1997 a

1 ATTACHMENT A DSN 001-B Oil and Grease Samplina DATE plSCHARGE ORIGIN SAMPLE TYPE 06-30-96 SGBD GSA 07-26-96 SG #2 Grab i

07 27 96 SG #2 Grab 07-31-96 SGBD Grab 08-22-96 SG #2 GSA 1

08-31-96 SG #2 GSA 08-31 96 SG #1 GSA 11-17-96 SG #1 GSA 11-17 96 SG #2 GSA 11-17 96 SG #3 GSA 11-17-96 SG #4 GSA 11-26-96 SG #1 GSA No further discharges

'I SGBD = Steam Generator Blow Down SG = Steam Generator GSA = Grab Sample Average

_.. = __. - --.

~.

e j

Mr. Edwerd D. Finger D11291/SES-97-GN-110/ Attachment B July 18,1997 ATTACHMENT B DSN 001-E Oil and Grease Samplina DATE DISCHARGE ORIGIN SAMPLE TYPE 06-13-96 Floor drains GSA 07-14-96 Floor drains GSA 07-25-96 A Bir Grab 07-25-96 B Bir Grab 08-02-96 Floor drains GSA 09-16-96 A Bir Grab 09-28-96 Floor drains GSA 10-07 96 A BLR Grab 10-18-96 A Bir Grab 10-30-96 Floor drains Grab 11-17-96 Floor drains GSA 11-26-96 B Bir Grab 12-21-96 Floor drains Grab 01 14-97 A Bir Grab 01 23-97 A Bir Grab 01-30-97 Floor drains GSA 02-08-97 A Bir GSA 03-29-97 Floor drains GSA 04-28-97 Floor drains Grab 05-05-97 B Bir Grab 05-05-97 A Bir Grab 06-17 97 Floor drains GSA Bir = Boiler GSA = Grab Sample Average

,e Northe:st 2

d*" 8"' 8"'"a 6037 Utilities System sorthe.,e utue. senice comp.ny i

P.o. Box 270 Itartford, CT 06141-0270 (860) 665-5000 July 18,1997 hoeNt$00l0

\\

SES-97-GN-109 i

D11296 Mr. James Grier Supervising Sanitary Engineer Water Management Bureau Department of Environmental Protection 79 Elm Street Hartford, CT 06106-5127 Connecticut Yankee Atomic Power Company Leakinu Screen Wash Control Valve l

Dear Mr. Grier:

As discussed with the Department on July 8,1997, a leaking control valve is allowing small volumes of chlorinated service water into the unit intake bays (DSN 001-1, monitoring location 7). By way of background, service water is used to remove river debris caught on the intake traveling screens. When the traveling screens are being 1

washed, the hypochlorite injection into the service water is isolated to prevent chlorinated water from getting into the intake bays. This control valve normally isolates the flow of service water into the intake bays when screen washing is not being performed. However, small amounts of chlorinated service water are now entering the intake bays when the control valve is in the " closed" position. Repair of the valve is awaiting replacement parts.

Due to the inaccessibility of the system, Connecticut Yankee can not quantitatively measure the volume of water leaking past the control valve. A conservative (stimate, based on operator knowledge of the system, is 5 gpm. The service water Tctal Residual Chlorine concentration has been approximately 0.07 mg/L for the previous few weeks, which is below the permitted limit of 0.2 mg/L. We have ordered the valve parts, but they are not expected to be available until October.

Should you have any questions concerning this matter, please contact Mr. Paul Brindamour, Connecticut Yankee Environmental Coordinator at (860) 267-3510.

oom nrx em

Mr. James Grier D11296/SES-97-GN-109/Page 2 July 18,1997.

Sincerely, CONNECTICUT YANKEE ATOMIC POWER COMPANY

<^

./

.. e a c e -

Director - Nuclear Engineering Programs cc:

NRC NRC Resident Inspector Michele DiNoia, Connecticut DEP l

l l

l l

i a

\\

    • 'g, gg gg 107 Selden Street, Berlin, Cr 06037 Utilities System Northeast Utihties Service Company P.o. Box 270 3

Ilartford, CT 06141-0270 July 18,1997 (860) 66sm i

SES-97-GN-108 g

D11264 DMR Processing Depanment of Environmental Protection Bureau of Water Management 79 Elm Street Hanford, CT 06106-5127

Reference:

Letter (C04782), NPDES Permit No. CT0003123, Haddam Neck Plant, Connecticut Yankee Atomic Power Company, dated September 30,1992.

Haddam Neck Plant June 1997 Monthly Discharue Monitoring Connecticut Yankee Atomic Power Company herein submits the attached report for the month of June 1997. Paragraph 4 of the NPDES Permit, Reference, requires that discharges from the permitted facility be monitored according to a specified schedule and results be reported to the Director of Water Compliance each month. Any variations from the permit are explained in the section headed "Results and Discussions" enclosed.

Additional samples that have been taken at NPDES locations and analyzed with approved methods are included in Table 2,3 and 4.

Should you have any questions or require further information, please call Mr. Paul Jacobson, Northeast Utilities Service Company, Environmental Services at (860) 447-1791, Extension 2335.

Very truly yours, CONNECTICUT YANKEE ATOMIC POWER COMPANY m,p 1/

pug S. E. S'cace Director - Nuclear Engineering Programs cc:

Mr. James Grier NRC NRC Resident inspector os3;n atvw

DMR, Processing D11264/SES-97-GN-108/ Enclosure /Page 1 July 18,1997 Enclosure Haddam Neck Plant Connecticut Yankee Atomic Power Company Results and Discussions NPDES Monthly Report - June 1997 Introduction i

This report fulfills the monitoring requirements for the Haddam Neck Plant (Connecticut j

Yankee), NPDES Permit No. CT0003123, dated September 30,1992. DMRs will be submitted as soon as compiled, but not later than the last day of the month following the report period as stated in the permit.

1 Results and Discussions Results of the continuous, weekly and monthly monitoring programs are summarized on the DMR sheets attached. All sampling and analysis except hydrazine, ethanolamine and boron were conducted in accordance with EPA approved procedures set forth in EPA Publication 600/4-79-020. For these three chemical substances, CYAPCO submitted its own procedures to i

DEP for approval on October 4,1996.

The computerized data logging report of the continuous monitoring program is included in Table 1. This report is included because it provides data for the daily range of pH, temperature, and flow; which are required under the NPDES permit. The DMR form does not have provisions for daily ranges.

DSN 001H. PCB Analysis On April 29,1997 the semi-annual stormwater sample for DSN 00lH was collected. Of the various substances required to be monitored, only the analysis for PCBs is performed off-site. As

. reported in the April 1997 DMR, the sample taken for this discharge could no be sent off-site for PCB analysis due to trace amounts of radioactivity in this sample. The issue was addressed with our outside laboratory and this discharge was resampled for PCBs on June 12,1997. The results 4

of this analysis are included in this report.

DSN 001-1. Intake Temocrature Beginning on the afternoon of Friday June 27,1997, and continuing through June 30, the in-line temperature probe for the intake was out of service. Grab samples were taken at a frequency on once every four hours over the weekend. On Monday June 30th the grab sample frequency was increased to once every hour. Results of the grab samples are included on Table 4. At no time were the permitted temperature limits exceeded.

- - -.. - - -. ~. -.---..

J DMR Processing D11264/SES-97-GN-108/ Enclosure /Pcge 2 July 18,1997 DSN 001-J. Auxiliary Boiler Blowdown On June 26, 1997, 11,000 gallons of auxiliary boiler blowdown was discharged. CYAPCO's NPDES permit limit for DSN 001-J is 10,000 gallons per day. At the time of the exceedance, the plant was trying to improve chemical control in the boilers. Once plant personnel suspected that the blowdown rate may have been too high, the flow was adjusted. The flow and chemical

' discharge data for this discharge are included in Table 3.

i

)

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION

~

Bure:u of Water M:nagement - Disch rgs Monitoring Rzport (DMR)

DATE RECEIVED (STAMPED)

Permit: CT0003123 MAJ Dist: 12 Town:061 Loc:008 Facility:

CT. YANKEE ATOMIC POWER PLANT

Contact:

Paul Jacobson Town: HADDAM NECK Phone: (860) 447-1791 ext. 2335 Logged:

Delivered:

OK*d:

KEY. CT0003123 issue: 093092 Expire: 09/30/97 Sample Month June 1997 Average Flow: 600000000 GPD ND = none detected j

Discharg 0011 Mon Loc: 1 NON-CONTACT COOLING WATER Sample Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq 1

2 3

4 5

1 00310 100192 0/0 CP MG/L BOD 5 DAY (20 DEG C) 02/99 Code 9

"~

00335 100192 0/0 CP MG/L CHEMICAL OXYGEN DEMAND 02/99 Code 9

~"

01042 100192 0/0 CP MG/L COPPER, TOTAL (AS CU) 02/YR Last sampled 2-97

~"

50050 100192 0/0 i

MGD FLOW, IN CONDUlT OR THRU 6

268 24/01 SEE ATTACHED TABLE 1 81313 100192 0/0 CP MG/L HYDRAZINE 02/99 Code 9 01051 100192 0/0 CP MG/L LEAD TOTAL (AS PB) 02/YR Last sampled 2-97 i-01067 100192 0/0 CP MG/L NICKEL, TOTAL (AS NI) 02/YR Last samp'ed 2-97

~"

00610 100192 0/0 CP MG/L NITROGEN, AMMONIA TOTAL 02/YR Last sartpled 2-97

~"

00556 100192 0/0 CP MG/L OIL & GREASE, FREON EX 02/YR Last 9;npled 2-97 r

34044 100192 0/0 G

MG/L OXIDANTS, TOTAL RESIDUAL Note 1 01/07 Note 1 No chlorine addition 00400 100192 0/0 i

SU PH 6.6 9.0 24/01 SEE ATTACHED TABLE 1 70300 100192 0/0 CP MG/L SOLIDS, TOTAL DISSOLVED 02/YR Last sampled 2-97 COMMENTS:

Code 9 = conditional monitoring Semi-annual TSS last sampled 2-97 Note 1 = No chlorination of circ water Page 1

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Wat;r Manag ment - Disch:rg2 Monitoring Report (DMR)

KEY: CT0003123 issue: 093092 Expire: 09/30/97 Sample Month June 1997 Average F!ow-600000000 GPD ND = none detected -

~

Discharg 0011 Mon Loc: 1 NON-CONTACT COOLING WATER Sample Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq 1

2 3

4 5

00530 100192 0/0 G

MG/L SOLIDS, TOTAL SUSPENDED 4.9 9.5 01/07 1.1 4.1 9.5 4.9 38260 100192 O!0 CP MG/L SURFACTANTS (MBAS) 02/YR Last sampled 2-97 00018 100192 0/0 i

DEG TEMP DIFF BETWEEN SAMP 0.0 2.1 7.4 01/01 SEE ATTACHED TABLE 1 See Table 4 and Letter 00011 100192 0/0 1

DEG TEMPERATURE DEG FAHR 62.8 74.8 86.6 24/01 SEE ATTACHED TABLE 1 00015 100192 0/0 CA MBTU THERMAL DISCHARGE MILL 2.0 152.1 01/30 SEE ATTACHED TABLE 1 01092 100192 0/0 CP MG/L ZINC, TOTAL (AS ZN) 02/YR Last sampled 2-97 COMMENTS:

KEY. CT0003123 issue: 093092 Expire: 09/30/97 Sample Month June 1997 Average Flow-600000000 GPD ND = none detected Discharg 0011 Mon Loc: 7 NON-CONTACT COOLING WATER Sample Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq 1

2 3

4 5

50050 100192 0/0 i

MGD FLOW, IN CONDU T OR THRU 6

268 24/01 SEE ATTACHED TABLE 1 00011 100192 0/0 l

DEG TEMPERATURE, DEG FAHR 81.3 24/01 SEE ATTACHED TABLE 1 COMMENTS:

l Page 2 a

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Buretu of Wat:;r M:nagement - Discharge Monitoring Report (DMR)

KEY: CT0003123 issue:093092 Expire: 09/30/97 Sample Month June 1997 Average Flow-600000000 GPD ND = none detected Discharg 0011 Mon Loc: G NON-CONTACT COOLING WATER Sample Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq 1

2 3

4 5

01042 100192 0/0 CP MG/L COPPER, TOTAL (AS CU) 02/YR Last sampled 2-97

~"

01051 100192 0/0 CP MG/L LEAD, TOTAL (AS PB) 02/YR Last sampled 2-97 01067 100192 0/0 CP MG/L NICKEL, TOTAL (AS NI) 02/YR Last sampled 2-97

~~

~"

00610 100192 0/0 CP MG/L NITROGEN, AMMONIA TOTAL 02/YR Last sampled 2-97 00556 100192 0/0 CP MG/L OIL & GREASE, TOTAL REC 02/YR Last sampled 2-97

~"

70300 100192 0/0 CP MG/L SOLIDS, TOTAL DISSOLVED 02/YR Last sampied 2-97 00530 100192 0/0 CP MG/L SOLIDS, TOTAL SUSPENDED 02/YR Last sampled 2-97

~"

38260 100192 0/0 CP MG/L SURFACTANTS,(MBAS) 02/YR Last sampled 2-97 01092 100192 0/0 CP MG/L ZINC, TOTAL (AS ZN) 02/YR Last sampled 2-97 KEY: CT0003123 issue: 093092 Expire: 09/30/97 Sample Month June 1997 Average Flow: 60000000 GPC ND = none detected Discharg 0011 Mon Loc: T NON-CONTACT COOLING WAWR Sample Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq 1

2 3

4 5

02/YR Last sampled 2-97 TGA6C 100192 0/0 CP P/F P/F STAT 96 HR ACU PIMEPH 02/YR Last sampled 2-97 TGA3D 100192 0/0 CP P/F P/F STAT 48 HR ACU D. PULEX 02/YR Last sampled 2-97 TGC3D 100192 0/0 CP P/F P/F STAT CHR DAPHNIA P.

02/YR Last sampled 2-97 TGC6C 100192 0/0 CP P/F P/F STAT CHR PIMEPHALES Page 3

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureru of Water Management - Dischrrge Monitoring Report (DMR)

KEY: CT0003123 issue:093092 Expire: 09/30/97 Sample Month June 1997 Average Flow: 16000 GPD ND = none detected Discharg 001 A Mon Loc: 1 STEAM ELECTRIC POWER PLANT

. Sample Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq 1

2 3

4 5

01022 100192 0/0 G

MG/L BORON, TOTAL (AS B)

NF 02/30 NO DISCHARGE 00164 100192 0/0 1

GPB FLOW, GALLONS / BATCH NF NF 01/DS NO DISCHARGE ~

01062 100192 0/0 G

MG/L MOLYBDENUM, TOTAL (AS MO NF 02/30 NO DISCHARGE 71850 100192 0/0 G

MG/L NITROGEN NITRATETOTAL NF 02/30 NO DISCHARGE 00615 100192 0/0 G

MG/L NITROGEN, NITRITE TOTAL NF 02/30 NO DISCHARGE

~"

00556 100192 0/0 G

MG/L OIL & GREASE, FREON EXTR NF 02/30 NO DISCHARGE 34044 100192 0/0 G

MG/L OXIDANTS, TOTAL RESIDUAL 0.17 01/07 0.17 0.11 0.09 0.07 0.05 Service Water Weekly maximums, see Table 2 00400 100192 0/0 i

SU PH NF NF 02/30 NO DISCHARGE 00530 100192 0/0 G

MG/L SOLIDS, TOTAL SUSPENDED NF 02/30 NO DISCHARGE

~"

COMMENTS:

KEY: CT0003123 issue: 093092 Expire: 09/30/97 Sample Month June 1997 Average Flow: 120000 GPD ND = none detected Discharg 001 B Mon Loc: 1 BLOW DOWN FROM HEAT / COOL Sample Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq 1

2 3

4 5

00310 100192 0/0 CP MG/L BOD 5 DAY (20 DEG C)

Code 9 02/99 00335 100192 0/0 CP MG/L CHEMICAL OXYGEN DEMAND Code 9 02/99 00940 100192 0/0 CP MG/L CHLORIDE (AS CL) 02/99 No Discharge

    • ~

COMMENTS:

Code 9 = Conditional monitoring Page 4

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bure u of Water Management - Discharge Monitoring Report (DMR)

KEY: CT0003123 Issue: 093092 Expire: 09/30/97 Sample Month June 1997 Average Flow: 120000 GPD ND = none detected Discharg 001 B Moa Loc: 1 BLOW DOWN FROM HEAT / COOL Sample Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq 1

2 3

4 5

01042 100192 0/0 CP MG/L COPPER, TOTAL (AS CU) 01/30 No discharge 00056 100192 0/0 T

GPD FLOW RATE, AVERAGE DAILY 24/01 No discharge 81313 100192 0/0 CP MG/L HYDRAZINE 02/99 No discharge 01045 100192 0/0 CP MG/L IRON, TOTA?. (AS FE) 01/30 No discharge 00556 100192 0/0 G

MG/L OIL & GREASE FREON EXTR.

01/30 No discharge 00400 100192 0/0 G

SU PH 01/30 No discharge 00665 100192 0/0 CP MG/L PHOSPHORUS, TOTAL (AS P) 01/90 No discharge 00530 100192 0/0 CP MG/L SOLIDS, TOTAL SUSPENDED 01/30 No discharge 00945 100192 0/0 CP MG/L SULFATE TOTAL (AS SO4) 02/99 No discharge 100192 0/0 CP MG/L ETA 01/07 No additions made COMMENTS:

Code 9 = Conditional Monitoring. Sampling only required when discharging wet lay up.

KEY: CT0003123 issue:093092 Exp;re: 09/30/97 Sample Month June 1997 Average Flow-22000 GPD ND = none detected Discharg 001 E Mon Loc: 1 WATER PRODUCTION WASTEWTR Sample Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq 1

2 3

4 5

01042 100192 0/0 CP MG/L COPPER, TOTAL (AS CU) 0.103 01/30 0.103 C0051 42195 0/1 CP MG/L DIMETHYL AMIDE ND

<1

<1 01/30

<1 Sampled at R-18 Page 5

STD.TE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PF.OTECTION Bureau of Water Management - Discharge Monitoring Report (DMR)

KEY: CT0003123 issue:093092 Expire: 09/30/97 Sample Month June 1997 Average Flow. 22000 GPD ND = none detected Discharg 001 E Mon Loc: 1 WATER PRODUCTION WASTEWTR Sample Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Frea 1

2 3

4 00056 100192 0/0 T

GPD FLOW RATE AVERAGE DAILY 5000 500C 01/30 5000 3

01045 100192 0/0 CP MG/L IRON, TOTAL (AS FE) 0.058 01/30 0.058 00556 100192 0/0 G

MG/L OIL & GREASE FREON EX ND

<1

<1 01/30

<1 00400 100192 0/0 l

SU PH 8.23 8.23 01/30 8.23 00665 100192 0/0 CP MG/L PHOSPHORUS, TOTAL (AS P)

<0.5 01/30

<0.5 00530 100192 0/0 G

MG/L SOLIDS TOTAL SUSPEND ND

<1

<1 01/30

<1 i

KEY: CT0003123 issue: 093092 Expire: 09/30/97 Sample Month June 1997 Average Flow. 28000 GPD ND = none detected Discharg 001 F Mon Loc: 1 NON-CONTACT COOLING WATER Sample Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq 1

2 3

4 5

C0051 42195 0/1 C? MG/L DIMETHYL AMIDE ND

<1

<1 01/30

<1 Sampled at R-18 l

00056 100192 0/0 1

GPD FLOW RATE AVERAGE DAILY NF NF 01/30 NO DISCHARGE 00556 100192 0/0 G

MG/L OIL & GREASE FREON EXTR NF NF 01/30 NO DISCHARGE 00400 100192 0/0 G

SU PH NF NF 01/30 NO DISCHARGE 00530 100192 0/0 G

MG/L SOLIDS, TOTAL SUSPENDED NF NF 01/30 NO DISCHARGE 00011 100192 0/0 G DEG TEMPERATURE DEG FAHR NF 01/30 NO DISCHARGE COMMENTS:

Page 6

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bure u of Wat::r M:nagement - Discharge Monitoring Report (DMR)

KEY: CT0003123 issue:093092 Expire: 09/30/97 Sample Month June 1997 Average Flow-INTERMITT GPD ND = none detected Discharg 001 G Mon Loc: 1 WATER PRODUCTION WASTEWTR Sample Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq 1

2 3

4 5

00556 100192 0/0 G

MG/L OIL & GREASE FREON EXTR 02/YR Last sampled 4-97 39516 100192 0/0 G

MG/L PCBS-POLYCHLORINATED 02/YR Last sampled 4-97 00400 100192 0/0 G

SU PH 02/YR Last sampled 4-97 KEY: CT0003123 Issue: 093092 Expire: 09/30/97 Sample Month June 1997 Average Flow INTERMITT GPD ND = none detected Discharg 001 H Mon Loc: 1 WATER PRODUCTION WASTEWTR Samp!e Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq

~2 3

4 5

00556 100192 0/0 G

MG/L OIL & GREASE FREON EXTR 02/YR Last sampled 4-97 39516 100192 0/0 G

MG/L PCBS-POLYCHLORINATE ND

<0.001

<0.001 02/YR

<0.001 Last sampled 6-97 See Letter for detads 00400 100192 0/0 G

SU PH 02/YR Last sampled 4-97 KEY: CT0003123 issue: 093092 Expire: 09/30/97 Sample Month June 1997 Average Flow 22400 GPD ND = none detected Discharg 001 i Mon Loc: 1 SAN SEWAGE 20,000 - 99,000 Sample Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq i

2 3

4 5

01097 100192 0/0 CP MG/L ANTIMONY, TOTAL (AS SB) 02/YR No Flow 01002 100192 0/0 CP MG/L ARSENIC, TOTAL (AS AS) 02/YR No Flow

~

00998 100192 0/0 CP MG/L BERYLLIUM, TOTAL (AS BE) 02/YR No Flow COMMENTS:

Page 7

STATE OF CONNECTICUT ** DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitoring Report (DMR)

KEY: CT0003123 issue: 093092 Expire: 09/30/97 Sample Month June 1997 Average Flow: 22400 GPD ND = none detected Discharg 001 i Mon Loc: 1 SAN SEWAGE 20.000 - 99,000 Sample Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq 1

2 3

4 5

00310 100192 0/0 G

MG/L BOD 5 DAY (20 DEG C) 04/30 No Flow 01027 100192 0/0 CP MG/L CADMlUM, TOTAL (AS CD) 02/YR

- No Flow 01032 100192 0/0 G

MG/L CHROMlUM, HEXAVALENT 02/YR No Flow 01034 100192 0/0 CP MG/L CHROMlUM, TOTAL (AS CR) 02/YR No Flow 01042 100192 0/0 CP MG/L COPPER, TOTAL (AS CU) 02/YR No Flow

"~

00722 100192 0/0 G

MG/L CYANIDE, FREE (AMEN. TO 02/YR No Flow 00720 100192 0/0 G

MG/L CYANIDE, TOTAL (AS CN) 02/YR No Flow 00056 100192 0/0 T

GPD FLOW RATE, AVERAGE DAILY 01/01 No Flow 01051 100192 0/0 CP MG/L LEAD, TOTAL (AS PB) 02/YR No Flow 71900 100192 0/0 CP MG/L MERCURY, TOTAL (AS HG) 02/YR No Flow 01067 100192 0/0 CP MG/L NICKEL, TOTAL (AS NI) 02/YR No Flow 05/07 No Flow 00300 100192 0/0 G

MG/L OXYGEN, DISSOLVED (DO) 00400 100192 0/0 G

SU PH 05/07 No Flow 46000 100192 0/0 CP MG/L PHENOLS 02/YR No Flow 01147 100192 0/0 CP MG/L SELENIUNI TOTAL (AS SE) 02/YR No Flow

~"

~"

01077 100192 0/0 CP MG/L SILVER, TOTAL (AS AG) 02/YR No Flow

"~

00545 100192 0/0 G

MG/L SOLIDS, SETTLEABLE 05/07 No Flow Page 8 Y

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bure u of Water Management - Discharge Monitoring Report (DMR)

KEY: CT0003123 issue: 093092 Expire: 09/30/97 Sample Month June 1997 Average Flow 22400 GPD ND = none detected Discharg 001 i Mon Loc: 1 SAN SEWAGE 20,000 - 99,000 Sample Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq 1

2 3

4 5

00530 100192 0/0 G

MG/L SOLIDS, TOTAL SUSPENDED 04/30 No Flow 00011 100192 0/0 G DEG TEMPERATURE, DEG FAHR 05/07 No Flow 01059 100192 0/0 CP MG/L THALLIUM, TOTAL (AS TL) 02/YR No Flow

~"

I 00070 100192 0/0 G

NTU TURBIDITY 05/07 No Flow 01092 100192 0/0 CP MG/L ZINC, TOTAL (AS ZN) 02/YP No Flow COMMENTS:

KEY: CT0003123 issue: 093092 Expire: 09/30/97 Sample Month June 1997 Average Flow: 22400 GPD ND = none detected Discharg 001 i Mon Loc: G SAN SEWAGE 20,000 - 99,000 Sample Weeks:

i Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq 1

2 3

4 5

04/30 No F!ow 00310 100192 0/0 G

MG/L BOD 5 DAY (20 DEG F) 00400 100192 0/0 G

SU PH 04/30 No Flow 05/07 No Flow 00545 10092 0/0 G

MG/L SOLIDS, SETTLEABLE 04/30 No Flow 00530 10092 0/0 G

MG/L SOLIDS, TOTAL SUSPENDED COMMENTS:

Page 9

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bure u of Water Management - Discharge Monitoring Report (DMR)

KEY: CT0003123 issue:093092 Expire: 09/30/97 Sample Month June 1997 Average Flow 22400 GPD ND = none detected Discharg 001 i Mon Loc: K SAN SEWAGE 20,000 - 99,000 Sample Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq 1

2 3

4 S

01/30 No Flow 81010 100192 0/0 CA

% BOD,5-DAY PERCENT REMOV 01/30 No Flow 81011 100192 0/0 CA

% SOLIDS, SUSPENDED PERCEN COMMENTS:

KEY: CT0003123 issue:093092 Expire: 09/30/97 Sample Month June 1997 Average Flow 10000 GPD ND = none detected Discharg 001 J Mon Loc: 1 BLOW DOWN FROM HEAT / COOL Sample Weeks:

Code Start s/m Typ Unit Parameter Min.

Ave.

Max.

Freq 1

2 3

4 5

00056 100192 0/0 T

GPD FLOW RATE. AVERAGE DAILY 11000 02/99 1000 3000 3000 11000 1000

~

~

Weekly Highs ontv, see Table 3 81313 100192 0/0 G

MG/L HYDRAZINE ND 0.012 01/90 <.004 <.004 <.004 0.012 <.004 Weekly H:ghs only, see Table 3 00610 100192 0/0 G

MG/L NITROGEN, AMMONIA TO ND

<0.4 01/90 <0.4

<0.4 <0.4

<0.4

<0.2 Weekly Highs only, see Table 3 00556 100192 0/0 G

MG/L OIL & GREASE FREON EXTR 01/90 00400 100192 0/0 i

SU PH 6.05 8.02 01/90 8.02 7.01 6.20 7.26 6.23 Weekly Highs only, see Table 3 00530 100192 0/0 G

MG/L SOLIDS, TOTAL SUSPEND ND

<1

<1 01/90

<1

<1

<1

<1

<1 COMMENTS:

Page 10

STATE OF CONNECTICUT " DEPARTMENT OF ENVIRONMENTAL PROTECTION Bureau of Water Management - Discharge Monitoring Report (DMR)

PERMIT:CT0003123 DIST:12 TOWN: 061 LOC: 008 FACILITY:

CT. YANKEE ATOMIC POWER PLANT MAILING NAME:

CT. YANKEE ATOMIC POWER CO.

ADDRESS: INJUN HOLLOW ROAD ADDRESS:

P.O. BOX 270 CITY, STATE, ZIP: HADDAM NECK, CT CITY, STATE, ZIP:

HARTFORD CT 06141 CONTACT:

MR. PAUL JACOBSON CONTACT:

MR. PAUL JACOBSON PHONE: 860-447-1791 Ext. 2335 PHONE:

860-447-1791 Ext. 2335 if there are any changes or corrections with your facility information, please cross out incorrect information and replace with correct information.

THIS DMR CONSISTS OF 11 PAGE3 FCR THE REPORTING PERIOD June 1997 STATEMENT Or-ACKNOWLEDGEMENT l certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel property gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my know-ledge and belief, true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possi-bility of fine and imprisonment for knowing violations.

Authorized Official:

S. E. Scace

Title:

Director-Nuclear Engineering Programs i

Signature:

/

mn Date:

^M/'6 EY Page 11

I TABLE 1, Page 1 CONN YANKEE STAT 104 MONTCLY WATER CJALITY DATA SUPWIARY / DISCHARGE SERIAL NUMBER 001

=

DATA PE;;IOD = 1 JUN 97/0000 - 30 JUN 97/2345 DATA ACQUISITION INTERVAL = MINUTES 00-15 0F EACH HOL9 DAY P3 RANGE FLOW RANGE CIRC PUMP MAX MIN AVG SDEV MAX MIN AVG SDEV MAX HL MIN HL AVG HL SD HL MRC HL MAX MIN AVG MAA MIN TEMP TEMP TEMP TEMP DEL T DEL T DEL T DEL T 1

7.1-6.8 0

0 0

0 0 71.7 68.9 70.2 0.8 7.4 3.2 5.1 1.1 0.0 0.0 0.0 0.0 0.0 2

6.9-6.7 6

0 3

0 0 69.3 65.9 67.7 0.9 4.1 1.0 2.7 1.2 12.3 0.0 5.1 5.6 12.2 3

6.9-6.6 0

0 0

0 0 68.8 64.5 66.2 1.5 3.2 0.0 1.4 1.1 0.0 0.0 0.0 0.0 0.0 4

7.1-6.7 186 0 45 1

0 67.4 62.8 65.3 1.3 3.2 0.0 1.4 1.0 152.1 0.0 6.3 31.0 -152.1 5

7.0- 6.9 7

0 0

0 0 68.9 64.4 66.3 1.4 3.2 1.7 2.3 0.4 6.5 0.0 0.3 1.3

-6.5 6

7.6-6.8 0

0 0

0 0 71.0 65.7 67.9 1.9 3.9 1.2 2.5 0.7 0.0 0.0 0.0 0.0 0.0 7

7.3-6.8 0

0 0

0 0 67.8 66.3 67.1 0.4 2.6 0.4 1.7 0.7 0.0 0.0 0.0 0.0 0.0 8

7.1-6.7 0

0 0

0 0 71.3 65.4 67.9 1.8 4.5 0.2 1.9 1.2 0.0 0.0 0.0 0.0 0.0 9

C.0- 6.8 0

0 0

0 0 76.3 66.9 70.7 3.4 7.0 0.6 3.2 2.3 0.0 0.0 0.0 0.0 0.0 10 8.4-6.9 1

0 0

0 0 75.9 70.0 71.7 1.8 6.5 1.1 3.2 1.4 0.8 0.0 0.0 0.2

-0.8 11 8.7-7.4 6

0 0

0 0 76.8 69.5 72.7 2.5 4.7 0.7 1.8 1.2 2.3 0.0 0.1 0.5

-2.3 12 8.8-7.7 6

0 5

0 0 79.7 72.0 75.0 2.6 4.6 0.6 1.8 1.2 13.9 0.0 5.2 3.9 4.9 13 8.4 7.4 6

6 6

0 0 77.0 75.3 76.0 0.5 3.1 1.3 2.2 0.6 9.4 3.8 6.6 1.8 2.2 14 7.6-7.1 6

6 6

0 0 77.5 74.7 76.0 1.0 2.2 0.0 1.2 0.6 6.6 0.0 3.6 1.9

-1.9 15 8.7-6.9 6

6 6

0 0 78.7 72.9 75.7 2.0 2.2 0.0 0.9 0.8 6.6 0.0 2.6 2.5

-2.2 16 9.0- 7.3 6

6 6

0 0 78.5 74.1 76.3 1.4 2.6 0.0 1.4 0.9 7.9 0.0 4.2 2.6 1.9

+

17 8.8-7.2 6

6 6

0 0 77.8 75.1 76.5 0.8 2.5 1.1 1.9 0.3 7.6 3.4 5.6 0.9 2.2 18 8.3-7.2 6

6 6

0 0 76.5 74.4 75.5 0.5 1.8 0.6 1.2 0.3 5.5 1.9 3.6 0.9

-1.3 19 7.6-6.9 6

0 2

0 0 78.5 74.4 76.1 1.5 4.1 1.0 2.2 1.0 3.9 0.0 1.2 1.7

-3.3 20 7.1-6.5 0

0 0

0 0 80.0 74.1 76.8 2.1 4.6 0.3 2.0 1.4 0.0 0.0 0.0 0.0 0.0 21 7.2-6.7 0

0 0

0 0 81.8 76.9 79.1 1.7 4.8 1.7 3.0 0.8 0.0 0.0 0.0 0.0 0.0 22 7.5-6.7 0

0 0

0 0 83.2 78.7 80.6 1.2 4.0 1.2 2.4 0.7 0.0 0.0 0.0 0.0 0.0 23 7.4-6.7 0

0 0

0 0 82.1 78.3 80.0 1.3 2.8 0.0 1.4 1.0 0.0 0.0 0.0 0.0 0.0 24 6.8-6.6 0

0 0

0 0 79.6 77.4 78.6 0.8 1.3 0.0 0.3 0.4 0.0 0.0 0.0 0.0 0.0 25 8.7-6.6 0

0 0

0 0 85.3 76.8 80.6 3.2 5.3 0.0 2.1 2.1 0.0 0.0 0.0 0.0 0.0 26 7.5-6.8 6

0 5

0 0 84.5 79.8 82.0 1.2 5.2 1.3 2.9 1.0 15.6 0.0 7.2 4.5 8.7 27 7.2-6.7 7

6 6

0 0 82.5 78.3 80.3 1.5 2.7 0.5 1.4 0.5 8.0 1.5 4.2 1.6

-6.6 28 7.5-6.9 12 6

6 0

0 85.6 77.6 80.9 2.6 ***** ***** ***** ***** ******* ******* ******* ******* *******

29 8.7-7.0 12 6

7 0

0 85.6 79.7 82.1 1.7 ***** ***** ***** ***** ******* ******* ******* ******* *******

I 30 8.7-7.2 12 6

7 0

0 86.6 80.1 82.6 1.8 ***** ***** ***** ***** ******* ******* ******* ******* *******

MCa 9.0- 6.6 186 0

4 1

0 86.6 62.8 74.8 5.6 7.4 0.0 2.1 1.4 152.1 0.0 2.0 6.7 -152.1 Pn KAZGE = LOWEST AND HIGHEST PM AT DISCHARGE CANAL (PH UNITS)

FLOW RANGE = LOWEST AND HIGHEST FLOW FROM DISCHARGE CANAL (10**3 GAL / MIN)

CIRC PUMP = LOWEST AND HIGHEST NUMBER OF CIRC PUMPS OPERATING i

MAX TEMP = MAXIMUM TEMPERATURE AT DISCHARGE STRUCTURE (DEG F) f;13 TEMP = MINIMUM TEMPERATURE AT DISCHARGE STRUCTURE (DEG F)

AVG TEMP = AVERAGE TEMPERATURE AT DISCHARGE STRUCTURE (DEG F)

SDEV TEMP = STANDARD DEVI ATION OF TEMPERATURE AT DISCHARGE STRUCTURE (DEG F) l MAX DEL T = MAXIMUM TEMPERATURE INCREASE BETWEEN INTAKE AND DISCHARGE (DEG F)

MIN DEL T = MINIMUM TEMPERATURE INCREASE BETWEEN INTAKE AND DISCHARGE (DEG F)

AVG DEL T = AVERAGE TEMPERATURE INCREASE BETWEEN INTAKE AND DISCHARGE (DEG F)

SDEV DEL T = STANDARD DEVI ATION OF TEMPERATURE INCREASE BETWEEN INTAKE AND DISCHARGE (DEG F) f MAX HL = MAXIMUM HEAT LOAD OF DISCHARGE WATER (10**6 BTU /HR)

MI3 HL = MINIMUM HEAT LOAD OF DISCHARGE WATER (10**6 STU/HR)

AVG ML = AVERAGE HEAT LOAD OF DISCHARGE WATER (10**6 BTU /HR)

SD HL = STANDARD DEVIATION OF HEAT LOAD OF DISCHARGE WATER (10**6 BTU /HR) l MRC HL = MAXIPKPt RATE OF CHANGE OF HEAT LOAD (NL FOR QUARTER HOUR T MINUS HL FOR QUARTER h0UR T-1/ QUARTER HOUR) (10**6 BTG/HR**2)

        • MEANS MISSING OR INSUFFICIENT DATA (LESS THAN 12 HRS / DAY OF VALID HOURLY DATA; LESS THAN 360 HRS / MONTH OF VALID HOURLY DATA)

F 3

e

TABLE 1, Pags 2 CDNN Y ANKEE STATION MONTHLY WATER QUALITY DATA Sups 4ARY / DISCHARGE SERIAL NUPSE2 001 EXCEPTION REPORT FOR MAXIMUM TEMPERATURE DIFFERENCE FROM INTAKE STRUCTURE TO DISCHARGE CANAL GREATER THAN 38 DEG F NONE EXCEPfl0N REPORT FOR MAXIMUM DISCHARGE TEMPERATURE AT DISCHARGE CANAL GREATER THAN 121 DEG F NONE EXCEPTION REPOR1 FOR PM AT DISCHARGE CANAL LESS THAN 6.0 OR GREATER THAN 9.0 PH UNITS DATE TIME FLOW INTAKE DISCHG PM PM 16 1415 6.0 8.3 9.0 16 1515 6.0 8.4 9.0 16 1615 6.0 8.3 9.0 w

e W

4

s 4-4 TABLE 2 June 1997 4

i AdditionalTRO Analysis for DSN 001 A. In ma/L l

Week 1 Week 2 Week 3 Week 4 Week 5 0.07 0.09 0.08 0.07 0.05 j

0.02 0.11 0.08 0.07 0.05 0.03 0.09 0.09 0.07

'i 0.03 0.09 0.09 0.06 j

0.13 0.08 0.08 0.06 i

0.16' O.09 0.09 0.06 I'

O.07 0.09 0.09 0.06 l

0.04 0.09 i

0.13 l

0.04 2

0.17 i

4 TABLE 3

^ '

June 1997 Connecticut Yankee. additional data (in ma/I)

DSN 001J Date Hydrazine Ammonia TSS pH Flow (gpd)

Bo.ler B. Boiler A Boiler B Boiler A Boiler B Boiler A Boiler B Boiler /i Boiler B Botier A 6/1/97 shut down shut down shut dowr.

shut down 0 shut down 6/2/97

< 004

<4 8.02 0

6/3/97

< 004

<4

<1 7.97 1000 6/4/97

< 004

<4 6.67 0

6/5/97

< 004

<4 6.75 1000 6/6/97

< 004

<.4 6.67 1000 6/7/97 1000 6/8/97 1000 6/9/97

< 004

<4

<1 7.01 1000 6/10/97

< 004

<4 6.29 1000 6/11/97

< 004

<4 6.05 3000 6/12/97

<.004

<4 6.05 10C0 6/13/97

< 004

<4 6.14 3000 6/14/97 2000 i

6/15/97 3000 6/16/97

< 004

<4

<1 6.20 2000 6/17/97 2000 6/18/97 0

6/19/97 3000 6/20/97 0

6/21/97 0

6/22/97 0

6/23/97 0.012

<4 6.81 0

6/24/97 0.010

<4

<1 7.26 1000 6/25/97 0.004

<4 6.36 4000 6/26/97

< 004

<.16 6.09/6.16 11000 t

6/27/97

< 004

<.16 6.31 8000 6/28/97 6000 i

6/29/97 0

f I

6/30/97

< 004

< 16

<1 6.23 1000 i:

l

[

1 1j Table 4 June 1997 Connecticut Yankee. Intake Grab Temperature Readinas 4

4 f

DSN 001-1 Date Time Temperature 6/27/97 1603 77 4

j 6/27/97-2001 77

}

6/28/97 0001 76 6/28/97 0400 73 i

6/28/97-0820 73 6/28/97 1202 77 6/28/97 1605

'75 l

6/28/97 2005 77 6/29/97 0005 75 l

6/29/97 0400 75 J

6/29/97 0810 75

)

6/29/97 1208 77 f

6/29/97 1605 77 6/29/97 2000 77 6/29/97 2358 75 6/30/97 0355 75 6/30/97 0815 75 6/30/97 1205 77 I