Forwards Insp Repts 50-373/97-10 & 50-374/97-10 on 970622-27.No Violation Noted.Nrc Concerned About Problems W/Radwaste Shipping Program That Should Have Been Resolved Through Facility self-assessment Process
ML20149J724
Person / Time
Site: LaSalle  Constellation icon.png
Issue date: 07/24/1997
From: Grobe J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Subalusky W
COMMONWEALTH EDISON CO.
Shared Package
ML20149J727 List:
References
50-373-97-10, 50-374-97-10, NUDOCS 9707290064
Download: ML20149J724 (2)


See also: IR 05000373/1997010

Text

Q t0

.

.-

July 24, 1997

,

.

.

Mr. W. T. Subalusky, Jr.

'

Site Vice President

LaSalle County Station

' Commonwealth Edison Company

2601 North 21st Road

Marseilles, IL 61341

Dear Mr. Subalusky:

SUBJECT:

NRC RADIATION PROTECTION INSPECTION REPORTS 50-373/97010(DRS);

50-374/97010(DRS)

,

On June 27,1997, the NRC ' completed an inspection at your LaSalle County Nuclear

Power Station. The purpose of the inspection was to review the solid radioactive waste

(radwaste) processing and shipping and the radiological environmental monitoring

programs. Observations of significant radiological work, such as the ongoing spent fuel

pool inventory reduction / cleanup activity, were also performed. The enclosed report

summarizes the results of this inspection.

We noted that the radiological environmental moeite ing program was well implemented,

'

that the radiological planning and controls for the spent fuel pool work were effective, and

that proactive efforts were taken by your staff to varify the material condition of the

radwaste tank rooms. We are concerned, however, with several problems that we

identified with the radwaste shipping program, some of which should have been resolved

through your self-assessment process. In particular, a Non-Cited violation was issued for

the failure to provide accurate guidance in the radioactive waste shipping procedures. We

also identified a weakness with the communication of radiological hazards to workers and

with the control of radioactive material. These specific problems resulted, in part, from

the failure to clearly communicate management expectations in station procedure.

,

In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter

and its enclosures will be placed in the NRC Public Document Room.

a

l

l

i

,

i

i

I

f

~

7

9707290064 970724

)

PDR

ADOCK 05000373

G

pg

$E!E!E!I%,Ill,$E

g o( ,

5

.

.

-

-

.

.

W. T. Subalusky

2

July 24, 1997

We will gladly discuss any questions you have concerning this inspection.

Sincerely,

Original Signed by John A. Grobe

John A. Grobe, Acting Director

Division of Reactor Safety

Docket Nos. 50-373; 50-374

Licenses No. NPF 11; NPF-18

Enclosure:

Inspection Reports 50-373/97010(DRS); 50-374/97010(DRS)

cc w/ encl:

T. J. Maiman, Senior Vice President,

Nuclear Operations Division

D. A. Sager, Vice President,

Generation Sua port

H. W. Keiser, Chief Nuclear

Operating Officer

F. Dacimo, Plant General Manager

P. Barnes, Regulatory Assurance

Supervisor

I. Johnson, Acting Nuclear

Regulatory Services Manager

i

Document Control Desk - Licensing

Richard Hubbard

,

Nathan Schloss, Economist,

Office of the Attorney General

State Liaison Officer

Chairman, Illinois Commerce Commission

Distribution:

Docket File w/ encl

Rlli PRR w/enct

A. B. Beach, Rlli w/ encl

PUBLIC tipM w/enct

LPM, NRR w/enci

J. L. Caldwell, Rlli w/ encl

j

OC/LFDCB w/ encl

SRIs, LaSalle, Dresden,

R. A. Capra, NRR w/enci

j

DRP w/enci

Quad Cities w/enci

Rlli Enf. Coordinator w/enci

DRS w/enci

TSS w/enct

CAA1 w/enct

DOCDESK w/enci

i

DOCUMENT NAME: G:DRS\\LAS97010.DRS

To receive a copy of M document. Indicate in the box: *C* = Copy without attachment / enclosure

"E" = Copy with attac

nt/ enclosure

"N* = No copy

,

OFFICE

RllI

$ RIII

6 RIII

lf RIIIDr/()

NAME

NShah:jp @

GShear (49

MDapas ts 6

JGrbb6

'

DATE

07/io /97

07/ u /97

07/ly/97

07/ W 97

0FFICIAL RECORD COPY

I

j