Forwards Response to NRC Compliance Bulletin 87-002, Fastener Testing to Determine Conformance W/Applicable Matl Specs
ML20149J234
Person / Time
Site: Grand Gulf Entergy icon.png
Issue date: 02/17/1988
From: Kingsley O
SYSTEM ENERGY RESOURCES, INC.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
AECM-88-2-0002, AECM-88-2-2, IEB-87-002, IEB-87-2, NUDOCS 8802220323
Download: ML20149J234 (52)


Text

_ _ _ _ _ _ _ _ _ _

6 i

SYETEM ENERGY RE50L!RCEE, INC.

1 'y ; c' ' m, s c+ % m*~ :,

February 17, 1988

.m U. S. Nuclear Reculatory Commission Washington, D. C.

20555 Attention: Document Control Desk Gentlemen:

SUBJECT:

Grand Gulf Nuclear Station Unit 2 Docket No. 50-417 Construction Permit No. CPPR-119 f

NRC Compliance Bulletin 87-02:

Fastener Testing to Determine Conformance with Applicable Material Specifications l

AECM-88/2-0002 l

l On November 16, 1987 System Energy Rescurces, Inc. (SERI) received NRC l

Compliance Bulletin No. 87-02:

"Fastener Testing to Determine Conformance l

with Applicable Material Specifications". This bulletin requested that l

licensees 1) review their receipt inspection recuirements and internal controls for fasteners and 2) independently determine, through testing, whether fasteners (studs, bolts, cap screws and nuts) in stores at their facilities meet reauired mechanical and chemical specification requirements.

l l

SERI's response to the bulletir for Grand Gulf Nuclear Station - Unit 2 l

is attached for your review. Based on a conversation with Mr. Leo Modenos, the submittal date of this response was deferred to February 17, 1988. The respense for Grand Gulf Nuclear Station - Unit I was submitted January 15, 1988 i

(AECM-86/0012).

j i

You

truly, I

ODK:brs

(

Attachment cc:

(See Next Pace)

I

$0?'EE!!!8888%

rf\\

DCD

', x.a..n x... y y,- l :.;w,;c

]

vs m u s. c co,

I f

J16AECM88021202 - 1

l AECM-88/2-0002 Page 2 cc: Mr. T. H. Cloninger (w/a)

~

Mr. R. B. McGehee (w/a)

Mr. N. S. Reynolds (w/a)

Mr. H. L. Thomas (w/o) i Mr.- R. C. Butcher (w/a)

-Or. J. Nelson Grace, Regional Administrator (w/a)

U. S. Nuclear Regulatory Commission Region II 101 Marietta St., N.

W., Suite 2900 Atlanta, Georgia 30323 Mr. L. L. Kintner, Project Manager (w/a)

Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Connission Mail Stop 14820 g

Washington, D.C.

20555 r

a i

t 1

I i

1 t

i i

r e

[

1 I

e i

i l.

J16AECM88021202 - 2 i

I AECM-88/2-0002 Page 3 bcc: Mr. J. E. Cross (w/a)

Mr. T. E. Reaves (w/a)

Mr. S. M. Feith (w/a)

Mr. C. R. Hutchinson (w/a)

Mr. F. W. Titus (w/a)

Mr. J. L. Robertson (w/a)

Mr. G. W. Muench (w/a)

Mr. J. R. Morris (w/2)

SSI Nuclear Activities (w/a)

File (LCTS) (w/2)

File (NS) (w/a)

File (NL) (w/a)

File (Central) (w/a) (

)

J16AECM88021202 - 3

i t

AFFID,AVIT STATE OF MISSISSIPPI

+

COUNTY OF HINDS O. D. Kingsley, Jr., being duly sworn, states that he is Vice President -

Nuclear Operations, of System Energy Resources, Inc.; that he is authorized on the part of said Company to sign and file with the Nuclear Regulatory Commissien this response to NRC Compliance Bulletin No. 87-02 on behalf of the Company and South Mississippi Electric Power Association; that he signed the foregoing letter as Vice President - Nuclear Operations, of System Energy Pesources. Inc.; and that the statements made and the matters set forth therein are true and correct to the best of his knowledge, infoivation and belief.

I kP./ Kin. /'041-j I

SUBSCRIBED AND SWORN TO befge me, a Notary Pyblic, in and for the County and State e.bove nared, this /fW day of3/w /,1988, t

]

(SEAL) l

/ ~ d~ b potaryPublic i

My corcission expires-

r. -

k l

J16 MISC 88021701 - 1

Attachment I to AECM-88/2-0002 Item 1)

Describe:

a) the characteristics currently examined during receipt inspection of fasteners (i.e., head markings for grade and manufacturer symbols, review of certified material test report or certificate of conformance) b)

internal controls utilized during storage and issuance from stock to assure the appropriate use of fasteners.

Response: 1.0) Receipt Inspection, Storage and Use of Fasteners 1.a) The Characteristics Currently Examined During Receipt inspection:

All fasteners procured by Bechtel for permanent plant ute on GGNS Unit 2 are procured as ASME or Safety Related regardless of application, i

NOTE: The Non-Safety Related bolting being stored in the Bechtel warehouse was supplied as part of 4

the Non-Safety Related specification for the 3

purchase of structural steel used in the erection of the Turbine Building.

)

A Material Receiving Instruction (MRI) is utilized for i

each procurement and identifies the following i

characteristics to be examined during the receipt of fasteners:

1)

Physical Inspection to Verify j

a.

identification and markings b.

dimensions and configuration a

I c.

workmanship i

Note:

For large bulk orders, the above verifications are accomplished through the use of representative samples selected in accordance with an approved sampling plan.

2)

Docume1tation Review a.

The Certified Material Test Report (CMTR) is reviewed to verify that the chemical and p3ysical properties of the material received satisfy the requirement of the applicable material / procurement specification.

b.

The document package is reviewed to verify that the supplier has submitted the required documentation in accordance with the purchase i

specification (G321-C), C of C, CMTR's, etc.

i 4

J16AECM88021202 - 4

Attachment a to AECM-88/2-0002 1.b) Internal Controls for Storage and Use of Fasteners 1)

Storage Controls:

a.

Access to the warehouse is limited to authorized personnel, b.

Fasteners are controlled during storage by segregation into containers / bins by type, size, and clessification.

2)

Issue Controls:

a.

Authorized personnel issue fasteners only after an approved Material Withdrawal Request is received identifying the material type, size and classification.

3)

Fasteners are visually inspected at time of installation to verify traceability (heat code),

correct material (markings), size and length to meet the design requirements.

Select a minimum sample of ten (10) non-safety)related fasteners Iten 2)

(studs, bolts, and/or cap screws), and ten (10 safety-related fasteners (studs, bolts, and/or cap screws) from current, in use, steck. The sample is to be obtained by the licensee with the participation of an NRC inspector.

Fasteners procured to meet the following chemical and mechanical properties are of interest: A-193 gredes B7, 88, and B16; SAE J429 grades 5 and 8; A a49; A-325 Types t

1, 2 or 31 A-354 grades BB, BC BD; A-490; A-320 LTM; A-307; A-563; or equivalent.

  • Pesponse: 2.0) Twenty-one samples of safety related and non-safety related fasteners were : selected by SERI with the participation of the i;RC resident irispector.

See Item 5 below for additional infortra tion.

Item 3)

For the selected sarsle of fasteners in Item 2, include a sample of typical nuts that wou:ld be used with euch fastener (one-for-one).

In particular, nuts purchased to the themical and mechanical l

specifications of A-19J are of intertst.

Pesponse: 3.0) Twenty-three nuts used With the fasteners in Item 2 were selected.

See Item 5 below for additional information.

1 Item 4)

Chemical testing shall be performed on all samples. Mechanical l

testing shall be performed on each safety-related fastener.

Hardness testing shall be perforned on each nut and non-safety-related fastener. All testing shall be performed by a laboratory which the licensee has qualified for this type of testing and appears an the i

licensee's approved vendor list.

Testing performed shall be done in i

J16AECM88021202 - 5 l

. to AECM-88/2-0002 accordance with the requirements of the fastener's specification, grade, and class, and the test shall evaluate the ultimate tensile strength, hardness and chemical properties as required by the fastener's specification, grade, and class.

Each sample shall be tagged with the sample's ID number.

Response: 4.0) See Item 5 below.

Item 5)

The results of all tests, together with supporting information, are to be rept;rted to the NRC utilizing the format shown in Attachments 1 and 2 of this bulletin.

Include the names and addresses of suppliers and manufacturers of safety-related fasteners and, to the extent possible, of non-safety-related fasteners.

For any fastener found out of specification, provide an evaluation of the safety significance including consideration of the most limiting application.

Response: 5.0) The selected fasteners were shipped to Wyle Laboratories (Huntsville, Alabama) for testing in accordance with the material specification for each fastener and the testing requirements stated in NRC Compliance Bulletin 87-02.

The testing was performed by Wyle Labo*atories and the test results were documented in Wyle Laboratories' Report No. 17908-01 "Physical and Chemical Testing of Various Fasteners for Use in Grand Gulf Nuclear Power Station", dated January 20, 1988. Wyle Laboratories evaluated the test results and, with the exception cf two samples described below, found all of the fasteners to be in accordance with the applicable material specifications.

The first sample found to be out of specification was GGNS-U2-Al which consisted of two (2) non-safety related nuts (both were out of specification). The second sample found to be out of specification was GGNS-U2-10 which consisted of one (1) safety related bolt for structural applications.

SERI's Nuclear Plant Engineering performed en independent evaluation of the test results and arrived at the same conclusions.

The evaluation of the safety significance of the two samples which were found to be out of specification is provided in Attachment 2.

. of this report contains the Fastener Testing Data Sheets. of this report contains the Data Sumary Sheets.

of this report contains fastener material suppliers, i

Item 6)

Based on the results of the testing and review of current procedures, describe any further actions being taken to assure that fasteners used in the plant meet the requisits specifications and requirements and that the operability of safety-related plant components is not affected.

Response: 6.0) Based on the review performed in Item 1 above, the acceptable test results and the evaluation discussed in Attachment 2, no further actions are required.

J16AECM88021202 6

l

to AECM-88/2-0002 i

i EVALUATION OF THE SAFETY SIGNIFICANCE OF BOLTING MATERIALS FOUND OUT OF SPECIFICATION 4

Sample No.: GGNS-V2-10

==

Description:==

ASTM A490 7/8" Dia, by 5" length Out of Specification Condition: Actual tensile exceeded specification range Safety Classification: Safety Related Bolt Application:

Structural Evaluation: The only specification requirement which was not met was the 1

maximuri tensile load requirement.

The actual tensile load to failure for the bolt was 86,000 lbf which exceeded the specification upper limit by 7.450 i

lbf. This bolt type is only used in structural applications where the bolted connections are designed as friction connections.

In friction connections the bolt is not loaded in shear but only in tension. The bolt tension is I

established by tnrouing the bolt / nut combination to c pre-determined valve.

The design of nuclear related structures is based upon static loading i

conditions. Fatigue loading, as would be seen in commercial buildings, is nel 4

a design facter. Therefore once the bolt / nut combination has been j

pre-stressed, the variations in live loading are not sufficient to cause a j

change in the bolt stress. The bolt..as-tested, exhibited a higher than specification ultimate tensile strength which by itself would not affect the performance of the bolt in its intended application. All other characteristics 1

of the bolt were acceptable. Therefore, when considering_the loading of the i

bolt and the operating environment in which the bolt is used, there is no l

safety sicnificance to this deviation from the material specification.

Sample No.: GGNS-U2-Al

==

Description:==

ASTM A194-2H Heavy Hex Nut 3/4" Dia.

Out of Specification Condition: Hardness values below specification range l

Safety Classificttion: Non-Safety Related J

Nut Application:

Structural j

s r

j Evaluation: Thes* non-safety related nuts are used in structural applications i

only. Using the bolt /out loading consideratiens discussed above, the load on the nut is a shear loading which would tend to strip the threads of the nut.

The nuts in question satisfactorily passed the proof load test which showed that the nuts would accept the design loads without stripping or rupture.

Therefore, the nuts would have satisfactorily performed their intended i

function. Based upon the satisfactory proof load test and the fact that the nuts are intended for non-safety related applications only, there is no safety significance to this deviation from the material specification.

j L

Y J16AECMS5021202 - 7

. to AECM-88/2-000?

Fastener Testing Data Sheet

  • Sample ID#: GGNS-U2-1 Fastener

Description:

1-1/8" x 6-1/2" All Thread. Stud, SA193 GR-87 Heat Code FX65 Description of Sample Stock Location: Unit 2 Warehouse Rack 16-A4 Material Specification as Documented by Licensee Records: 9645-M-205.0 Rev. 10 HeadMarking(SpecificationandManufacturer): B7, T, FX65

General Plant Application (e.g., Pressure Boundary, Structural) Pressure Boundary Vendor: Texas Bolt Co., P. O. Box 1211, Houston, Texas 77001 r

QA Requirements Imposed on Vendor: ASME Section III CL-2 Licensee Representative:

W. C. Finch

/4[7s Signature:

Ih M

Date:

I

/

7 j

  • The sample ids shall have a prefix that contains the ifcensee facility initials.
    • If applicable, please provide an explanation for your classification system.

i j

6 7

FxG5

\\

1 1

1 STOD

\\

J12 MISC 88021502 - 1

?

.. to AECM-88/2-0002 l

Fastener Testing Data. Sheet 1

  • Sample 10#: GGNS-U2-1A l

Fastener

Description:

1-1/8" Heavy Hex Nut, SA194 GR-2H, Heat Code DZ11 N

a l

Description of Sample Stock Location: Unit 2 Warehouse Rack 16-A4 i

Material Specification as Documented by Licensee Records: 9645-M-205.0 Rev. 5 l

Head Marking (Specification and Manufacturer): 2H, T, DZ11

-** Class / Procurement Level: ASME Section !!! CL-2 General Plant Application (e.g., Pressure Boundary, Structural): Pressure l

Boundary & Structural 4

Vender: Texas Bolt Co., P. O. Box 1211, Houston, TX 77001 3

QA Requirements Imposed on Vendor: ASME Section III CL-2 i

Licensee Representative:

W. C. Finch i

/4 !f7 Signature: // k a

Date:

j r

i

  • The sample ids shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

+

2.

+4

?

NUT J12 MISC 88021502 - 2

. to AECM-88/2-0002 t

Fastener Testing Data Sheet j

  • Sample IDi: GGNS-U2-2 Fastener

Description:

7/8" X 5-1/2" All Thread Stud Bolts SA193 GR-87 Heat i

Code LA73 Description of Sample Stock Location: Unit 2 Warehouse Rack 17-B5 Material Specification as Documented by Licensee Records: 9645-M-207.0 Rev. 14 Head Marking (Specification and Manufacturer): B7, T LA73 i

1

    • Class / Procurement Level: ASME Section III CL-1 General Plant Application (e.g., Pressure Boundary, Structural): Pressure Bounda ry Vendor: Texas Bolt., P. C Box 1211. Houston, Texas 77001 QA Requirements Imposed on Vendor: ASME Section !!! CL-1 i

I Licensee Representative:

W. C. Finch f

/ SkF

//

[

Av Date:

Signature: -

1 t

i

  • The sample ids shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

l s

W V

STUD BOLT I

f J12 MISC 88021502 - 3 i

. to AECM-88/2-0002 i

Fastener Testing Data Sheet i

1

  • Sample 10#: GGNS-U2-2A Fastener

Description:

7/8" Heavy Hex Nuts, SA194 GR-2H Heat Code C4 Description of Sample Stock Location: Unit 2 Warehouse Rack 17-A-5 i

I Material Specification as Documented by Licensee Records: 9645-M-207.0 Rev. 14 Head Marking (Specification and Nanufacturer): 2H,X,C4

General Plant Application (e.g., Pressure Boundary, Structural): Pressure Boundary & Structural Vender: Cardinal Industrial Products Corp., Las Vegas, Nevada 89118 QA Requirements Imposed on Vendor: ASME Section I!! CL-1 Licensee Representative:

W. C. Finch E!//! k Signature:

//

Date:

/

/

i j

  • The sample ids shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

g.

C4 U

bj dT J12 MISC 88021502 - 4 r

I

. to

-AECM-88/2-0002 Fastener Testing Data Sheet

  • Sample ID#: GGNS-U2-3 Fastener

Description:

5/8" X 4-3/4" All Thread Stud Bolt SA193 GR-B7 Heat Code K-2 Description of Sample Stock Location: Unit 2 Warehouse Rack 17-A9 Material Specification as Documented by Licensee Records: 9645-M-207.0 Rev. 14 HeadMarking(SpecificationandManufacturer): B7, C, K-2

    • Class / Procurement level: ASME Section III CL-1 General Plant Application (e.g., Pressure Boundary, Structural): Pressure Boundary Vender: Cardinal Industrial Products Corp., Las Vegas, Nevada 89118 QA Requirements Imposed on Vendor: ASME Section III CL-1 Licensee Representative:

W. C. Finch

%///,

f Signature:

/4.I k war Date:

~

f

/

  • The sample ids shall have a prefix that contains the licensee facility initials.

i

    • !f applicable, please provide an explanation for your classification system.

Y ].

l C

STUD BOLT J12 MISC 88021502 - 5

to AECM-88/J-0002 Fastener Testing Data Sheet
  • Sample 10#: GGNS-U2-3A Fastener

Description:

S/8" Heavy Hex Nut SA19a GR-2H Heat Code K-6 i

Description of Sample Stock Location: Unit 2 Warehouse Rack 17-A2 1

Material Specification as Occumented by Licensee Records: ~9645-M-207.0 Rev. 14 Head Marking (Specification and Manufacturer):

2H, U. K6 1

    • Class / Procurement level: ASME Section III CL-2 General Plant Application (e.g., Pressure Boundary, Structural): Pressure Boundary & Structural Vender: Cardinal Industrial Products Corp., las Vegas, Nevada 89118 1

QA Recuirements Imposed on Vendor: ASME Section III CL-2 Licensee Representative:

W. C. Finch Date:

/$ Y hk Sicnature:

/

/

  • The sample ids shall have a prefix that contains the licensee facility l

initials.

    • If applicable, please provide an explanation for your classification system.

~

u 4

WUT J12 MISC 88021502 - 6

- - - -. - - -i

A2tachment 3 to AECM-88/2-0002

's Fastener Testing Data Sheet

  • Sample ID#: GGMS-U2-4 Fastener

Description:

1/2" X 5-1/2" All Thread Stud Bolt SA193 GR-87 Heat

, Code C2 Description of Sample Stock Location: Unit 2 Warehouse Rack 17-Al 4

Material Specification as Documented by Licensee Records: 9645-M-207.0 Rev. 15 HeadMarking(SpecificationandManufacturer): B7, C

t General Plant Application (e.g., Pressure Boundary, Structural): Pressure Boundary Vender: Cardinal Industrial Products Corp., Las Vegas, Nevada 89118 CA Requirements imposed on Vendor: ASME Section III CL-1 Licensee Representative:

W. C. Finch Signature:

/// [

.h Date: 8 /d 7

/

(

/

  • The sample ids shall have a prefix that contains the licensee facility initials.

i

    • If applicable, please provide an explanation for your classification system.

i B7 CZ j

C l

STOD 0<)LT

)

i J12 MISC 88021502 - 7

i 1

. to r

AECM-88/2-0002 Fastener Testing Data Sheet

  • Sample 104: GGNS-U2-4A Fastener

Description:

1/2" Heavy Hex Nut SA194 GR-2H Heat Code DZ53 Description of Sample Stock Location: Unit 2 Warehouse Rack 17-Al Material Specification as Documented by Licensee Records: 9645-M-205.0 Rev. 5 I

Head Marking (Specification and Manufacturer): 2HT, 0Z53

    • Class / Procurement Level: ASME Section III CL-2 General Plant Application (e.g., Pressure Boundary, Structural):

Pressure Boundary & Structural vendor: Texas Bolt Co., P. O. Box 1211, Houston, Texas 77001 r

QA Requirements Imposed on Vendor: ASME Section III CL-2

[

Licensee Representative:

W. C. Finch

/8!fY Signature:

//

/ /

Date:

/

/

/

  • The sample ids shall have a prefix that contains the licensee facility initials.

l

    • If applicable, please provide an explanation for your classification system.

2HT e*+o i

i NUT J12 MISC 88021502 - 8

. to AECM-88/2-0002 Fastener Testing Data Sheet

  • Sample 10#: GGNS-U2-5 Fastener

Description:

1/2" x 41/4" HHH Bolt SA307 Gr. B Heat Code IQ39 Description of Sample Stock location: Unit 2 Warehouse Rack 16-B15 Material Specification as Occumented by Licensee Records: 9645-M205.0 Rev. 15 Head Marking (Specification and Manufacturer): TB,IQ39

    • Class / Procurement level: ASME Section III CL-1 General Plant Application (e.g., Pressure Boundary, Structural): Pressure Boundary Yendor: Texas Bolt Co., P. O. Box 1211 Houston, Texas ~ 77001 QA Requirements Imposed on Vendo.r: ASME Section III CL-1 Licensee Representative:

W. C. Finch

/S[77 M

Date:

Signature:

l r

/

  • The sample ids shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

1GL39 J12 MISC 88021502 - 9

I

, 'to AECM-88/2-0002 Fastener Testing Data Sheet 4

  • Sample 10#: GGNS-U2-5A Fastener

Description:

1/2" HH Nut SA-307 Gr. B Heat Code H073 Description of Sample Stock Location: Unit 2 Warehouse Rack 16-A15 Material Specification as Documented by Licensee Records: 9645-M-205.0 Rev. 14 Head Marking (Specification and Manufacturer):

T, H073

I General Plant Application (e.g., Pi essure Boundary, Structural):

Pressure Boundary Vendor: Texas Bolt Co., P. O. Box 1211, Houston, Texas 77251-1211 1

OA Recuirements Imposed on Vendor: ASME Section III CL. 2 Licensee Representative:

W. C. Finch i

Signature:

zh Date:

1 /b Y

/

/

  • The sample ids shall have a prefix that contains the licensee facility initials.

?

    • If applicable, please provide an explanation for your classification system.

a 8073 4

i

\\#

4 b

t J12 MISC 88021502 - 10

. to AECM-88/2-0002 i

Fastener Testing Data Sheet

  • Sample 10#: GGNS-U2-6 j

Fastener

Description:

5/8" X 31/4" HHH Bolt SA-307 Gr.-B Heat Code IF15 Description of Sample Stock Location: Unit 2 Warehouse Rack 16-B14 Material Specification as Documented by Licensee Records: 9645-M-205.0 Rev. 13 HeadMarking(SpecificationandManufacturer): TB, IF15

    • Class / Procurement Level: ASME Section III, CL-2 General Plant Application (e.g., Pressure Boundary, Structural): Pressure l

Boundary r

Vendor:

Texas Bolt Co., P. O. Box 1211, Houston, Texas 77001

[

QA Requirements Irnposed on Vendor: ASME Section III CL.-2 Licensee Representative:

W. C. Finch Signature: !/

s Date:

/d 7 t

i

  • The :, ample ids shall have a prefix that contains the licensee facility i

initials.

    • If applicable, please provide an explanation for your classification system.

i I

TB i

i IF15 i

BOLT J12 MISC 88021502 - 11

' to AECM-88/2-0002 Fastener Testing Data Sheet i

  • Sample IDd: GGNS-U2-6A Fastener

Description:

5/8" HH Nut SA-307 Gr. B Heat Code IF18 Descriptien of Sample Stock Location: Unit 2 Warehouse Rack 16-A15 Material Specificatien as Documented by Licensee Records: 9645-M-205.0 Rev. 13 l

Head Marking (Specification and Manufacturer):

T, IF18

    • Class /Precurement Level: ASME Section III, CL-2 General Plant Application (e.g., Pressure Boundary, Structural): Pressure Boundary l

Vender:

Texas Bolt Co., P. O. Box 1211, Houston, Texas 77001 OA Requirements Imposed on Vendor: ASME Section III CL-2 Licensee Representative:

W. C. Finch

/

t' Date:

/d/ [

Signature: ///

f I

\\

i

  • The sample ids shall have a prefix that contains the licensee facility initials.

[

    • If applicable, please provide an explanation for your classification system.

i j

4 I

i T

i I

i

/g

?

N UT l

i J12 MISC 88021502 - 12

. to j

AECM-88/2-0002 i

4 q

Fastener Testing Data Sheet

)

  • Sample 10#: GGNS-U2-7 j

l l

l Fastener

Description:

1" X 4 1/2" HHH Bolt SA-307 Gr.B Heat Code HD40

~

Description of Sample Stock Location: Unit 2 Warehouse Rack 16-C11 i

i Material Specification as Documented by Licensee Records: 9645-M-205.0 Rev. 14 i

l I

1 Head Marking (Specification and Manufacturer):' TB. HD40 I

    • Class / Procurement Level: ASME Section !!! CL-2 j

General Plant Application (e.g., Pressure Boundary, Structural):

Pressure Boundary I

Vender: Texas Bolt Co., P. O. Box 1211, Houston, Texas 77251-1211

}

l 1

i OA Requirements Imposed on Vender: ASME Section !!! CL-2 f

J l

Licensee Representative:

W. C. Finch

(

Signature:

I 2<

Date:

Y

/

/

l u

i

  • The sample ids shall have a prefix that contains the Itcensee facility 4

initials.

t i

~

    • If applicable, please provide an explanation for your classification system.

l t

l TB l

i HD40 I

i i

i J12 MISC 88021502 - 13 l

o

. to AECM-88/2-0002 Fastener Testing Data Sheet j

  • Sample 10#: GGNS-U2-7A i

Fastener

Description:

1" HH Nut SA-307 GR. B Heat Code H046 r

j Description of Samp12 Steck Location: Unit 2 Warehouse Rack 16-A11 t

Material Specification as Occumented by Licensee Records: 9645-M-205.0 Rev. 14

)

Head Markir.g (SpecH1 cation and Manufacturer):

T, HD46 i

I j

    • Class /Procurrr.ent Level: ASME Section !!! CL-2 i

General Plant Application (e.g., Pressure Boundary, Structural): Pressure Boundary Vender: Texas Bolt Co., P. O. Box 1211, Houston, Texas 77251-1211 OA Requirements Impeted on Vendor: ASME Section !!! CL-2 j

t Licensee Representative:

W. C. Finch

& /S! k Signature:

ah Date:

.{

/

/

j

  • The saeple ids shall have a prefix that contains the licensee facility initials.

l

    • If applicable, please provide an explanation for your classification system.

HD46 T

J12 MISC 88021502 - 14

Attachmen2 3 to j

AECM-88/2-0002 l

Fastener Testing Data Sheet

  • Sample 10#: GGNS-U2-8 i

Fastener

Description:

1" X 4-1/4" HHH Bolt A-325 Description of Sample Stock location: Unit 2 Warehouse Rack 29-A8 Material Specification as Documented by Licensee Records: 9645-C-131.0 and l

9645-C-131.5 Head Marking (Specification and Manufacturer): A325. RBW "Class /Procuremen't Level: Q Listed. Safety Related General Plant Application (e.g., Pressure Boundary, Structural): Structural Vendor: Not Traceable QA Requirements Imposed on Vender: Quality Program, Certificate of Compliance to Specifications l

t Licensee Representative:

W. C. Finch Signature: kbM Date:

/d

[

l

  • The sample ids shall have a prefix that contains the licensee facility i

initials.

    • !f applicable, please provide an explanation for your classification system.

{

A325 R

6 i

/N j

i

\\

N BOLT J12 MISC 88021502 - 15

. to AECM-88/2-0002 L

i Fastener Testing Data Sheet i

  • Sample IDf: GGNS-U2-8A i

Fastener

Description:

1" HH Nut A-325 j

4 i

Description of Sarple Stock Location: Unit 2 Warehouse Rack 28-88 i

i i

Material Specification as Documented by Licensee Records: 9645-C-131.0 and

[

9645-C-131.5 i

Head Marking (Specification and Manufacturer): Three lines spaced equidistant around the nut face

    • Class / Procurement Level: O Listed, Safety Related i

a General Plant Application (e.g., Pressure Boundary, Structural): Structural

[

Vender: Not Traceable QA Requirements Imposed on Vender: Quality Program, Certificate of Compliance l

2 to Specifications

~

(

Licensee Representative:

W. C. Finch Signature:

Il

  1. t[#

Date:

/4 Y l

'/

~

/

/

i i

i l

  • The sample ids shall have a prefix that contains the licensee facility

[

initials.

    • If acolicable, please provide an explanation for your classification system.

{

t t

i

)

NUT J12 MISC 88021502 - 16

l At%achment 3 to 1

AECM-88/2-0002 l

Fastener Testing Data Sheet i

  • Sample 10#: GGNS-U2-9 Fastener

Description:

1" X 8-1/2" HHH Bolt A325

)

i e

Description of Sample Stock Location: Unit 2 Warehouse Rack 28-A10 Material Specification as Documented by Licensee Records:

9645-C131.0 and 9645-C-131.5 1

HeadMarking(SpecificationandManufacturer): TB, A325

[

    • Class / Procurement level: Q Listed, Safety Related i

i General plant Application (e.g., Pressure Boundary Structural):

Structural t

i Vender: Not Traceable i

QA Recuirements Imposed en Vender: Quality Program, Certificate of Compliance j

to Specifications I

t Licensee Representative:

W. C. Fin:5 Signature: //! //

Date:

2- // Y

~'

/

/

a l

i

  • The sample ids shall have a prefix that contains the licensee facility j

initials.

1 l

    • !f applicable, plea;a prov'de an explanation for your classification system.

2 4

T B

I

)

/N l

A32F i

8 l

i 1

J12 MISC 88021502 - 17

. to AECM-88/2-0002 i

Fastener Testing Data Sheet

  • SampleIp: GGNS-U2-9A i

Fastener

Description:

1" HH Nut A325 l

Description of Sample Stock Location: Unit 2 Warehouse Rack 28-A8 1

Material Specification as Documented by Licensee Records: 9645-C-131.0 and

{

3 9645-C-131.5 4

HeadMarking(SpecificationandManufacturer): Three lines spaced equidistant around the nut face i

    • Class / Procurement Level: Q Listed, Safety Related i

i i

i

l General Plant Applicat'on (e.g., Pressure Boundary, Structural):

Structural l

)

Vendcr:

Not Traceable 1

OA Requirements Imposed on Vendor: Quality Program, Certificate of Compliance j

to Specifications j

Licensee Representative:

W. C. Finch

/d!M Sicnature:

/.4 Date:

/

j

  • The saeple ids shall have a prefix that contains the licensee facility initials.

4

    • If applicable, please provide an explanation for your classification system.

i

[

i t

v I

i 1

J12 MISC 88021502 - 18

f 1 to I

AECM-88/2-0002 j

l Fastener Testing Data Sheet i

  • Sample IO#: GGNS-U2-10 Fastener

Description:

7/8" X 5" HH Bolt A490 P

Description of Sample Stock Location: Unit 2 Warehouse Rack 29-A14 l

s Material Specification as Occumented by Licensee Records: 96a5-C-131.0 and 9645-C-131.5 t

HeadMarking(SpecificationandManufacturer): TB, A490 l

~

J

    • Class / Procurement Level: Q Listed, Safet; Related i

General Plant Application (e.g., Pressure Boundary, Structural): Structural Vender: Not Traceable i

i QA Requirements Imposed on Vendor: Quality Program, Certificate of Compliance l

to Specifications 4

l Licensee Representative:

W. C. Finch I

E!//[F7 f

Signature: [M me Date:

~/

/

/

)

~- ~ ~

i t

  • The sample ids shall have a prefix that contains the licensee facility I

1 initials.

i

)

i I

]

    • If applicable, please provide an explanation for your classification system.

i TB l

i A490 a

t l

j t

J12MISCS8021502 - 19

Attachment.3 to AECM-88/2-0002 Fastener Testing Data Sheet

  • Sample IDf: GGNS-U2-10A Fastener

Description:

7/8" HH Nut A194 GR-2H Description of Sample Stock Location: Unit 2 Warehouse Rack 28-Al Material Specification as Documented by Licensee Records: 9645-C-131.0 and 9645-C-131.5 Head Marking (Specification and Manufacturer): SV, 2H

    • Class / Procurement Level: Q Listed, Safety Related General Plant Application (e.g., Pressure Boundary, Structural): Structural /

Pressure Vender:

Not Traceable QA Requirements Imposed on Vendor: Quality Program, Certificate of Compliance to Specificatiens Licensee Representative:

W. C. Finch Signature:

A4' L

Date: 2 /d I

~/

,/

/

  • The sample ids shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classificatibn system.

S Y

2H J12MISCS8021502 - 20

' to l

AECM-88/2-000' 1

l-Fastener Testing Data Sheet

  • Semple 10#: GGNS-U2-11 l

Fastener

Description:

1/2" x 3" HHH Bolt, A307, Gr-A, Heat Code IQS 3 j

Description of Sample Stock Location: Unit 2 Instrumentation Loft Paterial Specification as Documented by Licensee Records:

9645-M205.0, Rev. 14 Head Marking (Specification and Manufacturer): TB,IQ53

General Plant Application (e.g., Pressure Boundary, Structural): Structural Vendor: Texas Bolt Co., P. O. Box 1211, Houston, Texas 77001 QA Requirements Imposed on Vendor: ASME Section III, CL-1 i

Licensee Representative: W. C. Finch Signature:

k[

W Date:

f

/

l

  • The sample ID# shall have a prefix that contains the licensee facility initials.

"If applicable, please provide an explanation for your cla isification system.

T8 1953 i

l l

O

. to AECM-88/2-0002 l

Fastener Testing Data Sheet

  • Sample 10#: GGNS-U2-11A Fastener

Description:

1/2" HH Nut, A307 Gr-A, Heat Code IQ54 j

4 Description of Sample Stock Location: Unit 2 Instrumentation Loft Material Specification as Documented by Licensee Records: 9645-M205.0, Rev. 14 1

l Head Marking (Specification and Manufacturer):

T,IQ54 i

i I

"Class / Procurement level: ASME Section !!!, CL-1 f

General Plant Application (e.g., Pressure Boundary, Structural): Structural Vendor:

Texas Bolt Co., P. O. Box 1211. Houston, Texas 77001 l

QA Requirements Imposed on Vendor: ASME Section !!!, CL-1 i

r Licensee Representative: W. C. Finch Signature:

wh Date:

M

/

)

}

  • The sample ID# shall have a prefix that contains the licensee facility initials.

"If applicable, please provide an explanation for your classification system.

i C.f.

)

. to AECM-88/2-0002 i

e Fastener Testing Data Sheet

  • Sample IDi:

GGNS-U2-12A Fastener

Description:

1 1/8" HH Nut SA194, Gr-7, Heat Code Y1 Description of Sample Stock Location: Unit 2 Warehouse, Rack 17-03 Material Specification as Occurented by Licensee Records:

9645-M207.0, Rev. 15 Head Marking (Specification and Manufacturer):

C, Y1. 01, 7 "Class / Procurement Level:

ASME Section III, CL-1, Dcwngraded to ASME Section III, CL-2, per NCR-6793 General Plant Application (e.g., Pressure Boundary, Structural): Pressure Boundary Vendor:

Cardinal Industrial Products, Las Vegas, Nevada 89118 QA Requirements Imposed on Vendor: ASME Section III CL-1, Ref. NCR-6793 Licensee Representative:

W. C. Finch Signature:

///

Date:

FT

/

/

  • The sample IDf shall have a prefix that contains the licensee facility initials.

"If applicable, please provide an explanation for your classification system.

C s

O/

7

. to AECM-88/2-0002 Fastener Testing Data Sheet

  • Sample 10#: GGNS-U2-13A Fastener

Description:

2 3/4" HH Nut, A563, Gr-0 Description of Sample Stock Location:

Unit 2 Warehouse, Rack 8-B2 Ksterial Specification as Documented by Licensee Records:

9645-M205.0, Rev. 14 Head Marking (Specification and Manufacturer):

T, 0 "Class / Procurement Level:

Safety Related General Plant Application (e.g., Pressure Boundary, Structural):

Structural Vender: Texas Bolt Co., P. O. Box 1211, Houston, Texas 77001 QA Requirerents Irposed on Vendor: Quality Program, ASTM Licensee Representative:

W. C. Finch F[ M Sigr.a ture :

Date:

/

/

/

  • Tne sample IDi shall have a prefix that contains the licensee facility initials.

"If applicable, please provide an explanation for your classification system.

T D

l

. to AECM-88/2-0002 Fastener Testing Data Sheet

  • Sample IDf: GGNS-U2-A, Non-Safety Related Fastener

Description:

3/4" x 3 1/4" HH A490 Bolts (2ea.)

Description of Sample Stock Location: Unit 2 Warehouse Rack 30-C8 Material Specification as Documented by Licensee Records:

9645-C-122-0 9645-C-131-1 Head Marking (Specification and Manufacturer):

SBC A490

    • Class / procurer 4nt Level: Non Q, Non Safety Related General plant Application (e.g., Pressure Boundary, Structural) Structural Vender:

Stupp Bros. Bridge & Iron Co.

St. Louis, Missouri QA Requirements imposed on Vendor: Certificate of Compliance to Specification Licensee Representative: W. C. Finch Signature: kl M4k l Date:

/ l 3//h'?

tihe sample 108 shall have a prefix that contains the licensee facility initials.

    • If applicable, please provide an explanation for your classification system.

An SBc Au

. to AECH-88/2-0002 Fastener Testing Data Sheet

  • Sample 10#: GGNS-V2-A1, Non-Safety Related Fastener

Description:

3/4" HH Nut A194-2H (For A490 Bolt)

(2ea.)

Description of Sample Stock Location: Unit 2 Warehouse Rack 30-C8 Paterial Specification as Documented by Licensee Records:

9645-C-122-0 9645-C-131-1 Head Marking (Specification and Manufacturer):

P 2H

    • Class / Procurement i.evel: Non Q, Non Safety Related General Plant Application (e.g., Pressure Boundary, Structural) Structural Vendor:

Stupp Bros. Bridge & Iron Co., St. Louis, Missouri QA Requirements Imposed on Vendor: Certificate of Compliance to Specification Licensee Representative:

W. C. Finch Signature: h v

Date:

/w/ 3//9 7 V'

  • l

/

/

  • The sample 10# shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

f H

. to j

AECM-88/2-0002~

Fastener Testing Data Sheet

  • Sample 10#:

GGNS-U2-8 Fastener

Description:

3/4" x 3 1/4" HH Bolt A325 (2ea.)

Description of Sample Stock Location: Unit 2 Warehouse Rack 30-B1 Material Specification as Documented by Licensee Records:

9645-C-122-0 9645-C-131-1 Head Marking (Specification and Manufacturer): 58 A325

    • Class / Procurement Level: Non Q, Non Safety Related General Plant Application (e.g., Pressure Boundary, Structural) Structural Vendor:

Stupp Bros. Bridge & Iron Co., St. Louis, Missouri QA Requirements Imposed on Vendor: Certificate of Compliance to Specification Licensee Representative:

W. C. Finch Signature: _ //

[

  1. r' Date:

/

3/[92

/

/

/

  • The sample 10# shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system, h

8 9

4

/

\\

p.a

. to AECM-88/2-0002 Fastener Testing Data Sheet

  • Sample 10#:

GGNS-U2-81, Non Safety Related Fastener

Description:

3/4" HH Nut A325 (2ea.)

Description of Sample Stock Location: Unit 2 Warehouse Rack 30-C2 Drum #1 Material Specification as Documented by Licensee Records:

9645-C-122-0 9645-C-131-0 Head Marking (Specification and Manufacturer):

(See Sketch Below)

    • Class / Procurement Level: Non Q, Non Safety Related General Plant Application (e.g., Pressure Boundary, Structural) Structural Vendor:

Stupp Bros. Bridge & Iron Co., St. Louis, Missourf QA Requirements Imposed on Vendor: Certificate of Compliance to Specification Licensee Representative: W. C. Finch

/#

Date:

/2-5///7 Signature: _ 4/

' /

/

/

i

  • The sample 10p shall have a prefix that contains the licensee facility initials.

1

    • If applicable, please provide an explanation for your classification system.

l 1

3 i

==

I

\\

/

por

. to AECM-88/2-0002 Fastener Testing Data Sheet

  • Sample 10#: GGNS-U2-C, Non Safety Related Fastener

Description:

1" x 5" HH A325 Bolt (2ea.)

Description of Sample Stock Location: Unit 2 Warehouse Rack 30-C6 Material Specification as Documented by Licensee Records:

9645-C-122-0 9645-C-131-0 Head Marking (Specification and Manufacturer):

RSW A325

    • Class / Procurement level: Non Q, Non Safety Related General Plant Application (e.g., Pressure Boundary, Structural) Structural Vendor:

Stupp Bros. Bridge & Iron Co., St. Louis, Missouri QA Requirements Imposed on Vendor: Certificate of Compliance to Specification Licensee Representative: W. C. Finch

/

Signature:

pM Date:

/J' 5//F7

/

/

  • The sample 10# shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

s R,

8

/f

^

' to AECM-88/2-0002 Fastener Testing Data Sheet

  • Sample IDd: GGNS-U2-C1, Non Safety Related Fastener

Description:

1" HH Nut A325 (2ea.)

Description of Sample Stock Location: Unit 2 Warehouse Rack 30-C6 Paterial Specification as Documented by Licensee Records: 9645-C-122-0 9645-C-131-0 Head Marking (Specification and Manufacturer):

(SeeSketchBelow)

    • Class / Procurement Level: Non Q, Non Safety Related General Plant Application (e.g., Pressure Boundary, Structural) Structural Vendor:

Stupp Bros. Bridge & Iron Co., St. Louis, Missouri QA Requirements Imposed on Vendor: Certificate of Compliance to Specification Licensee Representative: W. C. Finch

/3!5//87 Signature: _/d'/

Date:

i i

j

  • The sample 10# shall have a prefix that contains the licensee facility initials.

"If applicable, please provide an explanation for your classification system.

C3'

/

\\

l Od

. to AECM-88/2-0002 Fastener Testing Data Sheet

  • Sample ID#: GGNS-U2-0, Non Safety Related Fastener

Description:

1"x 5" HH Bolt A325 Description of Sample Stock location: Unit 2 Warehouse Rack 30-C6 Material Specification as Documented by Licensee Records:

9645-C-122-0 9645-C-131-1 Head Marking (Specification and Manufacturer): A325 RBW

    • Class / Procurement Level:

Non Q, Non Safety Related General Plant Application (e.g., Pressure Boundary, Structural) Structural Vendor:

Stupp Bros. Bridge & Iron Co.. St. Louis, Missouri QA Requirements Imposed on Vendor: Certifica,te of Compliance to Specification Licensee Representative:

W. C. Finch Signature: [

M Date:

/

/[/7

'/

/

/

  • The sample 10# shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

A325' r

R 8

/N w

84

. to AECM-88/2-0002 Fastener Testing Data Sheet

  • Sample 10#: GGNS-U2-01, Non Safety Related Fastener

Description:

1" HH A325 Nut Description of Sample Stock Location: Unit 2 Warehouse Rack 30-C6 Material Specification as Documented by Licensee Records:

9645-C-122-0 9645-C-131-1 Head Marking (Specification and Manufacturer):

(See Sketch Below)

    • Class / Procurement Level:

Non Q, Non Safety Related General Plant Application (e.g., Pressure Boundary, Structural) Structural Vendor:

Stupp Bros. Bridge & Iron Co., St. Louis, Missouri QA Requirements Imposed on Vendor: Certificate of Compliance to Specification Licensee Representative:

W. C. Finch

/J[3/!f7 Signature:

//

/

Date:

  • The sample 10# shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

C7 )

J W

NvT

. to AECM-88/2-0002 Fastener Testing Data Sheet

  • Sample ID#: GGT 1,5-U2-E, fion Safety Related Fastener

Description:

3/4" x 3 1/4" Hll Bolt A490 Description of San:ple Stock Location: Unit 2 Warehouse !!ack 30-CU ftaterial Specification as Documented by Licensee Records:

9645-C-122-0 9645-C-131-1 Head Marking (Specification and Manufacturer):

A490, SB

    • Class / Procurement Level:

Non Q, fion Safety Related General Plant Application (e.g., Pressure Boundary, Structural) Structural Vender:

Stupp Bros. Bridge & Iron Co., St. Louis, Missourl 0A Requirements Imrosed on Vendor:

Certificate of Compliance to Specification Licensee Representative:

W. C. Finch p

Signature: __ M/

Date: lp 3/

7

/

l

  • The sample 104 shall have a prefix that contains the licensee facility initials.
    • 1f applicable, please provide an explanation for your classification systen.

1 N H Cl0 28 l

l 1

. to AECM-88/2-0002 Fastener Testing Data Sheet

  • Sample IDi: GGNS-U2-El, Non Safety Related Fastener

Description:

3/4" HH A194 Gr 2H Nut (For A490 Bolt)

Description of Sample Stock Location: Unit 2 Warehouse Rack 30-C8 Material Specification as Documented by Licensee Records: 9645-C-122-0 9645-C-131-1 Head Marking (Specification and Manufacturer):

P, 2H

    • Class / Procurement Level:

Non Q, Non Safety Related General Plant Application (e.g., Pressure Boundary, Structural) Structural Vendor:

Stupp Bros. Bridge & Iron Co., St. Louis, Missouri QA Requirements Imposed on Vendor:

Certificate of Compliance to Specification Licansee Representative:

W. C. Finch Signature:

[/],

/2-[5/[#7 4

Date:

  • The sample 10# shall have a prefix that contains the 1Icensee facility initials.
    • If applicable, please provide an explanation for your classification system.

P

%r

4

  • to AECM-88/2-0002 Fastener Testing Data Sheet
  • Sample 10#: GGNS-U2-F, Non Safety Related Fastener

Description:

(2) 3/4" x 3" HHH A490 Bolts Description of Sample Stock Location: Unit 2 Warehouse Rack 30-C8 Material Specification as Documented by Licensee Records:

9645-C-122-0 9645-C-131-1 Head Marking (Specification and Manufacturer): A490, S B

    • Class / Procurement level: Non Q, Non Safety Related G3neral Plant Application (e.g., Pressure Boundary, Structural) Structural Vendor:

Stupp Bros. Bridge & Iron Co., St ' ~ , Missouri QA Requirements Imposed on Vendor: Cert

.e or Compliance to Specification Licensee Representative:

W. C. Finch Signature:

Date: />5/[F7

{

/

/

  • The sample I0i shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

8B l

j

. to AECM-88/2-0002 Fastener Testing Data Sheet

  • Sample ID#: GGNS-U2-F1, Non Safety Related Fastener

Description:

(2)3/4"HHNutsA194-2H Description of Sample Stock location: Unit 2 Warehouse Rack 30-C8 Material Specification as Documented by Licensee Records:

9645-C-122-0 9645-C-131-1 Head Marking (Specification and Manufacturer):

P, 2H

    • Class / Procurement Level: Non Q, Non Safety Related General Plant Application (e.g., Pressure Boundary, Structural) Structural Vendor:

Stupp Bros. Bridge & Iron Co., St. Louis, Missouri QA Requirements imposed on Vendor: Certificate of Compliance to Specification Licensee Representative:

W. C. Finch Signature: _ f/

.<ah Da te:

/

/:2 3//f 7

-(

.i t

i

  • The sample IDi shall have a prefix that contains the licensee facility initials.
    • If applicable, please provide an explanation for your classification system.

?

2 j

=

^ to AECM-88/2-0007 Data 5ttenary Hechanical Analysis Ommical Analysis

_ID#

Hardness UTS 0.2% YS C

Mn_ _

P S

St Mo Cr CCNS-U2-1 RC30,32 159.8KSI 147.2KSI C.42%

0.94%

0.006%

0.021%

0.24%

0.19%

0.96%

CCNS-U2-2 RC32,33 142.6KSI 128.7KSI O. 3%

0.84%

0.008%

0.035%

0.24%

0.19%

0.88%

CCNS-U2-3 RC31,31 142.7KSI 124.3KSI 0.45%

0.94%

0.014%

0.017%

0.26%

0.16%

1.00%

CCNS-U2-4 RC29,30 137.3KSI 123.3KSI G.41%

0.8%

0.012%

0.034%

0.25%

0.16%

1.00%

CCNS-U2-5 RB74,74 10,5751b f 0.010%

0.011%

Note 1 GCNS-U2-6 RB%,94 19,6251bf 0.009%

0.025%

Note 1 GCNS-U2-7 RB 92,93 43,500lbf 0.011%

0.014%

Note 1 GCNS-U2-8 RC 32,32 87,100lb f 0.38%

0.?7%

0.007%

0.020%

Note 1 GCNS-U2-9 RC24,24 77,500lbf 0.42%

0.65%

0.014%

0.017%

Note 1 Note: UTS-ultimate tensile strength; YS yield strength; C-carbon; Mn-Manganese; P-Phosphorous; S-Sulfur; Si-Silicon; j

Mo-Molybdenum; Cr-Chromium.

1The elements listed apply to ASTM A193 B7 or SA193 B7 material. The elements to be reported for other materials tested, shall conform to those reported in the applicable material specification. Properties found out of specification shall be noted with an asterisk.

Note 1 - 10 Degree Wedge Tensile Strength i

    • - Not required by Material Specificatien i

'ATTACl! MENT - 1 1

i

~-

_ _ _ _ _ _ _ _ _ _ __ _ _ _ ____ _ ; \\

_m

" to AECM-88/2-0002 E tm Surmmry 1

Mechanical Analysis Chemical Analysis y

Hardness UTS 0.2% YS, C

Mn P

S Si Mo Cr CCNS-U2-10 RC35,35 86,000lbf*

55,450lbf 0.4%

0.86%

0.00 n 0.023%

0.26% 0.18%

0.88%

0.21% Ni Note 1 Note 2 CCNS-U2-11 RB97,99 12,62515f 0.015%

0.013%

Note 1 CCNS-U2-A RC 36,35 52,300lbf 40,100lb f 0.41%

1.07%

0.018%

0.01 %

0.24% 0.32%Cu 0.51%

0.3A Ni Note 3 Note z RC 36,36 51,900lbf 40,100* I

0. 4 %

1.08%

0.018%

0.01 %

0.24% 0.32%Cu 0.51%

0.3% Ni Note 3 Note 2 CCNS-U2-B RC33,33 45,000lbf 0.38%

0.69%

0.005%

0.017%

Note 1 RC33,34 45,200lb f 0.37%

0.69%

0.005%

0.016%

Note 1 CCNS-U2-C RC31,31 99,100lbf 0.45%

0.%%

0.008%

0.074%

Note 1 RC34,35 97,300lbf 0.45%

0.94%

0.00 %

0.024%

Note 1 Note: UTS-ultimate tensile strength; YS yield strength; C-carbon; Mn-Manganese; P-Phosphorous; S-Sulfur; St-Silicon; Mo-Molybdenum; Cr - Otromium.

elements listed apply to ASTM A193 B7 or SA193 B7 material. *[he elements to be reported for other materials tested, shall conform to those reported in the application material specification. Properties found out of specification shall be noted with an asterisk.

Note 1 - 10 Degree Wedge Tensile Strength

    • Not Required by Material Specification Note 2 - Proof load Note 3 - 6 Degree Wedge Tensile Strength 1

ATTACHMENT - 2

o Attschment 4 to P

AECM-88/2-0002 Data Summary Mechanical Analysis (hemical Analysts IDA Hardness tTIS 0.2% YS C

Mn P

S Si Mo Cr 0.31%

0.64%

0.005%

0.017%

CCNS-U2-D RC31,32 84,000lbf i

Note 1 (X;NS-U2-E RC36,36 50,700lbf Lo,100lb f 0.42%

0.95%

0.026%

0.031%

0.22% 0.20%

0.93%

0.16% Ni Note 3 Note 2 CCNS-U2-F RC35,35 52,300lb f 40,100lbf 0.37%

0.99%

0.008%

0.022%

0.24% 0.20%

1.02%

0.04% Ni Note 3 Note 2 RC35,35 51,000lb f 40.10015f

0. 3%

1.03%

0.011%

0.030%

0.25% 0.18%

1.0%

0.05% Ni Note 3 Note 2 I

a 4

Note: UTS ultimate tensile strength; YS yield strength; C-carbon; Mn-Manganese; P-Phosphorous; S-Sulfur; Si-Silicon; Mo-Molybdenum; Cr-Oiromium,

=

i The elements listed apply to ASTM A193 B7 or SA193 B7 material. The elements to be reported for oth(r materials tested, shall conform to those reported in the applicable material specification. *roperties found out of specification shall be noted with an asterisk.

Note 1 - 10 Degree Wedge Tensile Strength

    • - Not required by Material Specificatian i

Note 2 - Proof Load Note 3 - 6 Degree Wedge Tensile Strength i

I ATTACHMENT - 3

.l 2

i

.m._

I l

~ s

' to AFCM-88/2-0002 Data Siimmarv I

Mechanical Analysis Chemical Arulysis IDe Ilardness Proof 1.oad(thf) 0.n YS C

Mn P

S Si

_Mo Cr l

i

. CCNS-t'2-1A RC28,30 Note 1

0. An 0.013%

0.021%

l CCNS-U2-2A RC31,33 80,850 0.46%

0.021%

CCNS-U2-3A RC31,31 39,550 0.40%

0.02n 0.020%

CCNS-U2-4A RC36,36 74,830 0.38%

0.017%

0.02%

  • t CCNS-U2-5A-RB98,98 14,1401 0.11%

0.00 %

0.016%

0.On 0.009%

0.019%

CCNS-U2-6A RB92,93 22,600 CCNS-U2-7A RB90,90 60,600 0.46%

0.013%

0.013%

CCNS-U2-6A RB89,89 87,300 0.4%

0.014%

0.01A CCNS-U2-9A RB%,94 87,300 0.4n O.014%

0.013%

CCNS-U2-10A RC31,31 80,850 0.48%

0.006%

0.024%

Note: UTS ultimate tensile strength; YS yield strength; & carbon; Mn-Hanganese; P-Phosphorous; S-Sulfur; Si-Silicon; Mo-Molybdeous; Cr-Chromium.

1The elements listed apply' to ASDt A193 B7 or SA193 B7 tr.aterial, 1he elements to be reported for other materials tested, l

shall conform to those reported in the applicable materini specification. Properties found out of specification shall be noted with an asterisk.

Note 1 - Not required for nuts where proof load would exceed 120,000 lbf

    • - Not required by Material Specification ATTAOftENT - 4

. ~.

~ -.

'# to AECM-88/2-0002 s

D.ata Surnmiry Mechanical Analysis O e.tcal Analysts y

Hardness Proof Imd(thf) 0.M. YS C

Mn P

S St Mo Cr CCNS-U2-11A RB87.5,90 14,200 0.10%

0.004%

0.027%

O.03% Ni CCNS-U2-12A RC27,28 Note 1 0.38%

0.71%

0.022%

0.021%

0.24%

0.017%

1.00%

CCNS-U2-13A BI!N 179 Note 1

(:.40%

0.74%

0.016%

0.021%

CCNS-U2-Al RC15,15*

58,450 0.47%

0.007%

0.016%

RC14,15*

58,450 0.46%

0.005%

0.016%

CCNS-U2-B1 RB94,95 48,100 0.08%

0.004%'

O.059%

RB91,92 48,100 0.08%

0.004%

0.064%

CCNS-t12-C1 RB99,100 87,300 0.4H%

0.007%

0.024%

RB91,92 87,300 0.54%

0.003%

0.013%

0.47%

0.005%

0.021%

CCNS-U2-D1 RB95,95 87,300 CCNS-U2-El RC34,34 58,450 0.45%

0.010%

0.016%

Note: ITIS-ultimate tensile strength; YS yield strength; C-carben; Mn-Manganese; P-Phosphorous; S-Sulfur; St-Silicon; Mo-Molybdenum; Cr-Chromium.

1The elements listed apply to ASTM A193 B7 or SA193 B7 enaterial. lhe elements to be reported for other materials tested, shall conform to those reported in the applicable riaterial specification. Properties found out of rpecification shall be noted with an asterisk.

Note 1 - Not required for outs where proof load would excted 320,000 lbf

    • - Not required by Material Specification ATTAOIMENT - 5 m

8-to AE01-88/2-0002 Data Simaary 1

Mechanical Analysis O_'emical Analysis ids flardness Proof laid (1hf) 0.7% YS C

Mn P-S St No Cr D.45%

0.011%

0.016%

CCNS-U2-F1 RC25,27 58,450 RC28.30 58,450 0.4%

0.011%

0.015%

Notet ifTS-ultimate tensile strength; YS yield strength; C-carbon; tei-Manganese; P-Phosphorous; S-Sulfur; Si-Silicon; Mo-Molybdenum; Cr-Chrositum.

The elevients listed apply to ASDt A193 B7 or SA193 B7 materiel. The elements to be reported for other materials tested, shall conform to those reported in the applicable material specification. Properties found out of specification shall be noted with an materisk.

Note 1 - Not required for nuts where proof load would cyceed 120,000 lbf

    • - Not required by Material Specification ATTAfttMENT - 6

...... to AECM-88/2-0002 FASTENER MATERIAL SUPPLIERS

  • Ace Bolt & Screw Co.

Erico Products, Inc.

P. O. Box 22533 34600 Solon Road Jackson, MS 39205 Solon, OH 44139 Aero Fast Mfg.

F & S Central P. O. Box 324 c/o Wholesale Electric Wheaton, IL 60187 P. O. Box 479 Natchez, MS 39120 Ammo Fastening Service

  • Hilti Fastening Systems, Inc.

USM Corporation 1120 Deposit Guaranty Bank Bldg.

Broadwey Terrace, Apt. A-8 Jackson, MS 39201 i

Clinton, MS 39056 1

A & T Supply ITT Phillips Drill Division P. O. Box 63 P. O. Box 364 Salt Lake City, Utah Michigan City, IN 46360 i

Basco Fastaning Service

  • Jackson Bolt & Screw, Inc.

P. O. Box 16114 P. O. Box 9505 3116 Bellbronk Drive Jackson, MS 39206 Femphis, TN 38116 Buildex Leonard Jed Co.

2500 Brickvale Drive 1301 Covington St.

l Elk Grove Village, IL 60007 Baltimore, MD 21230 i

Capitol Bolt & Screw Co.

Liberty Equip. & Supply Co.

P. O. Box 4551 620 East Bruneau Avenue Jackson, MS 39216 Kennewick, WA 99336-2

  • Cardinal Industries Nelson Stud Welding 3873 West 0quedo Division of TRW, Inc.

Las Vegas, NV 89118 9108 Chandler Road i

4 Dallas, TX 75247 Daniel Bolt Company Standco, Inc.

P.O. Box 292 P. O. Box 87 Houston, TX 77001 Houston, TX 77001 t

i i

i

. J16AECM88021202 - 8

..s s to AECM-88/2-0002-l FASTENER MATERIALS St'PPLIERS- (continued)

  • Texas Bolt Company Threaded Products, Inc.

P. O. Box 1211 3604 Spring Park Road Houston, TX 77001 Jacksonville, FL 32207 4

V' Indust fal, Inc.

USM Corporation-188 Selig Dr. S.W.

c/o Bob Crosby Atlanta, GA 30036 Route 8, Box 36 Jackson, MS 39213 Venfabrics, Inc.

  • Chicago. Tube & Iron Chicago, IL 60632 2531 West 48th. Street Chicago, IL 60642
  • Safety-related fasteners were purchased from these vendors.

I i

a i

4 i

l 4

t

{

1 J

J16AECM88021202 - 9

- - - - - - - - - - - -