.k,
-, MEMORANDUM T0: ~ John F. Stolz, Director Project Directorate I-2 Division of Reactor Projects - I/II Office of Huclear Reactor Regulation FROM:
Donald S. Brinkman, Senior Project Manager (Original signed by)
Project Directorate 1-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
SUBJECT:
FORTHCOMING MEETING WITH DUQUESNE LIGHT COMPANY (DLC), BEAVER VALLEY POWER STATION, UNIT NO.,1, 10 CFR 50.61, UPDATED INFORMATION FOR PRESSURIZED THERMAL SH0CK EVALUATION DATE & IIME:
Tuesday, August 5,~1997 j
1:00 p.m.
LOCATION:
U.S. Nuclear Regulatory Commission One White Flint North, Room 0-8811 11555 Rockville Pike North Bethesda, MD 20852 PURPOSE:
To discuss plans and schedules for resolutien of 10 CFR 50.61 i
updated information for pressurized thermal shock evaluation.
PARTICIPANTS *:
Participants of the meeting from NRC include members of the Office of Nuclear Reactor Regulation (NRR) and members and consultants of DLC.
[(RC/NRR QL.
Westinahous_g 4
D. Brinkman B. Eiliot S. Jain E. Terek J. Stolz L. Lois S. Sovick S. Anderson J. Strosnider R. Schaaf D. Weakland K. Wichman W. Kline ATI Consultina M. Mitchell 2-T. Greisbach 1
Docket No. 50-334
Attachment:
Meeting Agenda
Attachment:
Meeting Agenda cc w/att:
See next page CONTACT:
Donald Brinkman (301) 415-1409
- Meetings between NRC technical staff and applicants or licensees are open for interested members of the public, petitioners, intervenors, or other parties l
to attend as observers pursuant to " Commission Policy Statement on Staff Meetings Open to the Public" 59 Federal Register 48340,9/20l94_.
OFFICE PDI-2/PM/)M PD}95/LA/2 PDI-2/P N /1 #01-2/D
\\
TLiu:cw k MNrkeW DBrinkman Stolz NAME l DATE 1 // f/97
~
[/[//h7 7 / / P'/97 y6 97
/
00COMENT NAMe:
BV96303.MTG 0FFICIAL RECORD COPY 9707230144 970719 y
PDR ADOCK 05000334 P
PDR alsilWilp!n NRC M
~
m m.
d.
anc g
T UNITED STATES a
S NUCLEAR REGULATORY COMMISSION f
WASHINGTON. D.C. mi k...../
July 18, 1997 MEMORANDUM T0: John F. Stolz, Director Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation h
i FROM:
Donald S. Brinkman, Senior Project Manag r,
Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
SUBJECT:
FORTHCOMING MEETING WITH DUQUESNE LIGHT COMPANY (DLC), BEAVER VALLEY POWER STATION, UNIT NO. 1, 10 CFR 50.61, UPDATED INFORMATION FOR PRESSURIZED THERMAL SH0CK EVALUATION DATE & TIME:
Tuesday, August 5, 1997 1:00 p.m.
LOCATION:
U.S. Nuclear Regulatory Commission One White Flint North, Room 0-8B11 11555 Rockville Pike North Bethesda, MD 20852 d
I PURPOSE:
To discuss plans and schedules for resolution of 10 CFR 50.61 updated information for pressurized thermal shock evaluation.
PARTICIPANTS *:
Participants of the meeting from NRC include members of the Office of Nuclear Reactor Regulation (NRR) and members and consultants of DLC.
NRC/NRR QG Westinaho. gig D. Brinkman B. Elliot S. Jain E. Terek J. Stolz L. Lois S. Sovick S. Anderson J. Strosnider P.. Schaaf D. Weakland K. Wichman W. Kline ATI Consultina M. Mitchell T. Greisbach Docket No. 50-334
Attachment:
Meeting Agenda cc w/att:
See next page CONTACT:
Donald Brinkman (301) 415-1409
- Meetings between NRC technical staff and applicants or licensees are open for interested members of the public, petitioners, intervenors, or other parties to attend as observers pursuant to " Commission Policy Statement on Staff Meetings Open to the Public" 59 Federal Reaister 48340, 9/20/94.
d,
~
f' 1
i Duquesne Light Company Beaver Valley Power Station Units 1 & 2 7
i cc:
Jay E. Silberg, Esquire Bureau of Radiation Protection Shaw, Pittman, Potts & frowbridge Pennsylvania Department of 2300 N Street, NW.
Environmental Resources Washington, DC 20037 ATTN: Michael P. Murphy Post Office Box 2063 Director-Safety and Licensing Harrisburg, PA 17120 Department (BV-A)
Duquesne Light Company Mayor of the Borrough of Beaver Valley Power Station Shippingport PO Box 4 Post Office Box 3 Shippingport. PA 15077 Shippingport, PA 15077 Commissioner Roy M. Smith Regional Administrator, Region.I West Virginia Department of Labor U.S. Nuclear Regulatory Commission 1
Building 3. Room 319 475 Allendale Road Capitol Complex King of Prussia PA 19406 Charleston, WVA 25305 Resident Inspector Director, Utilities Department U.S. Nuclear Regulatory Commission Public Utilities Commission Post Office Box 298 180 East Broad Street Shippingport PA 15077 Columbus, OH 43266-0573 Director, Pennsylvania Emergency Duquesne Light Company Management Agency Beaver Valley Power Station Post Office Box 3321 PO Box 4 Harrisburg, PA 17105-3321 Shi)pingport, PA 15077 ATM:
S. C. Jain, Vice President Ohio EPA-DERR Nuclear Services (BV-A)
ATIN:
Zack A. Clayton Post Office Box 1049 J. E. Cross
-Columbus, OH 43266-0149 President-Generation Group Duquesne Light Company Dr. Judith Johnsrud Beaver Valley Power Station National Energy Committee PO Box 4'
. Sierra Club Shippingport, PA 15077 433 Orlando Avenue State College, PA 16803 Duquesne Light Company Beaver Valley Power Station PO Box 4
.Shippingport, PA 15077 ATIN:
R. L. Grand, Division Vice President, Nuclear Operations Group and Plant Manager (BV-SOSB-7)
l MEETING AGENDA MEETING BETWEEN NRC AND DUOVESNE LIGHT COMPANY PRESSURIZED THERMAL SH0CK ANALYSIS BEAVER VALLEY POWER STATION. UNIT NO. 1 AUGUST 5. 1997 On August 5, 1997, NRC staff will meet with DQquesne Light _ Company to discuss the Beaver Valley Power Station, Unit No.1 pressurized thermal shock (PTS) analysis required by 10 CFR 50.61.
Requests for additional information regarding this analysis has created the need for a meeting to discuss details suppcrting the PTS analysis. The following agenda will form the framework for this meeting:
- Purpose and Background
- Current PTS evaluation methodology
- Resolution strategy
- Conclusions ATTACHMENT
July 18, 1997 l
-Meeting Notice, Duquesne?. Light Company, Westinghouse, ATI Consulting, and NRC on August 5, 1997 DISTRIBUTION:
EMail Scollins/FMiraglia RZimmerman BBoger JStolz DBrinkman Tliu M0'Brien Dross.(E-Mail to SAM)
-OPA PEselgroth WDean
-DScrenci JStrosnider KWichman MMitchell BElliot Llois RSchaaf Hard Copy
, Docket"sfiT(
PUBLIC PDI-2 r/f OGC ACRS Receptionist, 0WFN and TWFN i