Text
r
'C'1 Pr:, ct F 5 _
WM Record file D::at n.-
"O.
Mr. Charles J. Temus Technical Director DEC 31 W MM Nuclear Packaging, Inc.
1010 South 336th Street
' Federal Way, Washington 98003 L----
Dear Mr. Temus:
b m ? bg,y" 3 7%
Enclosed are our coments and questions concerning the topical report that describes the NUPAC Enviralloy family of High Integrity Containers. This request for additional information is also being sent to participating agreement states for information only.
We encourage you to continue a line of comunication with us to ensure that the questions and comments are fully understood before submitting your responses in writing. Assuming that your responses are satisfactory and are received in a timely period, we are proposing the following :;chedule for completion of the review.
It is our sincere intent that every effort will be made to comply with this schedule.
Transmit formal Coments to NUPAC -------------------
12/31/87 Receive NUPAC Responses -----------------------------
1/15/88 Complete Response Evaluation and Initiate a Technical Evaluation Report (TER) ---------------
1/31/88 Complete the TER ------------------------------------
2/15/88 Internal Review and Concurrence of TER --------------
2/26/88 Transmit TER to States to Begin Preparation of Certificates of Compliance and to NUPAC with Request for Revised Topical Report ----------
2/28/88 As is customary, we are treating the enclosed comments and questions as proprietary for the sake of expediting the review. We would appreciate your assistance in identifying the information in our questions and in your forthcoming responses that NUPAC truly considers to be proprietary.
Please contact me if you have any questions or if you need any additional information.
Sincerely, Keitd.6 K. McDaniel, t terisis Engineer 8802180023 871231 SB5 Technical Branch PDR Division of Low-level Waste Management and Decomissioning, NMSS
Enclosure:
Coments DISTRIBUTION:
'LLW/SF LLTB r/f KMcDaniel NMSS r/f MTokar JJSurmeier A
h----:--- I f f---:--- 2 C.::LLI G,-
0FC :LLTB
- LLTB h
--p NAME :KMcDaniel
- MTokar
- durmejer DATE :3./A/r?
- lL/p / 77 N/#/h 0FFICIAL RECORD COPY l