July 18, 1997
+
MEMORANDUM TO: FrIncis M. Castillo, Chi:f Nucl: r Materials Sifaty Branch 111, RI Douglas M. Collins, Deputy Director Division of Nuclear Materials Safety, Rll Roy J. Caniano, Deputy Director Division of Nuclear Materials Safety, Rlll Linda Howell, Chief Nuclear Materials inspection Branch, RIV D. Blair Spitzberg, Chief Nuclear Materials Licensing Branch, RIV
- Frank Wenslawski, Chief Walnut Creek Field Office, RIV FROM:
Larry W. Camper, Chief Medical, Academic, & Commercial Use Safety Branch -
Division of industrial and Medical Nuclear Safety, NMSS
SUBJECT:
STATUS OF SEALED SOURCE AND DEVICE REQUEST FOR REGISTRATION i
Attached are listings of the sealed source and device pending cases as of July 17, 1997. Attachment 1 contains actions that were submitted as a technical assistance request from headquarters or the regions, and attachment 2 lists those actions that have been filed directly by the vendor, for product evaluation and registration.
Attachments:. As stated
Contact:
KimBerly Randall, NMSS (301) 415-8140.
/
DISTRIBUTION: w/ enclosures
/
SGreene, IMAB VCampbell, RIV.
SSSS Staff w/o encls.
JKinneman, RI
. JPiconne, IMOB NMSS r/f IMAB r/f JMadera, Rlli CHosey, Rll SSSS r/f IMNS Central JPotter, Ril MShanbaky, RI
. SKimberty, LFMB DCool GJackson, LFMB JJohansen,RI CFrazier, Rlli BPrange,RIV WCFO GShear, Rlli FCombs Mmeenan, Rlll LJacobs-Baynard PMDA SVillar, RI
. TDecker, Ril NEO2-SSD-7 th MPhillips, Rlli llflll*lll*!llllllllll}llll CCain, RIV CPederson, Rlll DChamberlain, RIV ABlough,' RI DOCUMENT NAME: G:\\ Regions. Reg Ta retelve e copy of this document, Indicate in the boa:
"C* = Copy without attachment / enclosure "E" = Copy with attachment / enclosure "N* = No copy l OFFICE IMAB g,,
l_}lMAB l
lMAB (o f# [
l l
l l
NAME KRanffTnt S8aggett LCamper l
___l DATE 7// 997 7/ /97 7/[G/97 m
9707220115 97071g m
OFFICIAL RECORD COPY PDR RC RD pgp
t Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 7/18/97 Actions recorded as of Friday, July 18,1997 HQ b Gase(s) Assigned to Heviewer(s) lotaling 6 Action (s)
Control Assign. #
Number Actions Reviewer Company Model Numbers 021878 06-104
.kwood Kidde Fenwal. Inc.
CPD 705X Smoke Detector 021882 96-105 Burgess Detection Systems, Inc.
DS260 lonization Smoke Detector 1
021890 97-03 Compton Hesco, Inc.
021900 97-34 Unassigned PSI Powertronic Systems, Dnft Tube Assembly 1
0216650 96-45 Smith E.I. Company El 100 BUS,100 SUS,100LUS 3
1 Sealed Source Safety Section i
Pending Sealed Source & Device Actions Tied to Licensing Actions By Region for the period 1/1/01 to 7/18/97 Actions recorded as of Friday, July 18,1997 RI 3 case (s) Assigned to Reviewer (s) Iotaling 16 Action (s) 7 htrol Assign. #
l Number Actions Reviewer Company Model Numbers 109601 96-113 Broaddus Safety Ught Corporation Various 14 120195 94-60 Broaddus Bethlehern Steel Corp.
28-8B 124672 97-48 Unassigned Allegheny University Hosp.
SrO.A53 I
1 Sealed Source Safety Section
T Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/18/97 For actions recorded as of Friday, July 18,1997 Date Assign #
Received Reviewer Actions Company Model Numbers Status 10/17/94 94-60 Broaddus 1 Bethlehem Steel Corp.
28-8B To fees on 11/1/94.
Ltr frm fees to Bethlehem Corp. req. additonal fees.
11/7/94.
Rtrned frm fees on 1/5/95.
def Itr 1/31/95 ta request complete package.
30 day abandonment Itr sent 9/8/95.
Revd reply frm abandonment Itr on 10/10/95 5/9/95 95-44 Broaddus 1 Dept of Army CAM NR-155-D-119-S to fees 5/12/95. fee OK 5/16/95.
Def. ltr sent on 7/20/95.
Action has been transferred to D. Broaddus frm M. Perkins as of 8/14/95 Resp. rcvd on 10/18/95.
Def. call on 9/27/96.
Resp. rcvd by fax on 9/27/96.
Def. call on 11/20/96.
Resp. revd on 12/12/96.
5/19/95 95-47 Broaddus 1 Sony Chemical Corp.
WG8 new custom device to fees 5/19/95. fee OK L
'L 5/24/95.
Def. Itr sent on 7/15/96.
Resp. revd on 12/6/96.
2/13/96 9649 Smith 1 Ohmart SH-F, SH, SR Series To fees on 2/15/96.
Rtrned frm fees on 2/16/96 Action will be reassigned to Eric Jamerson.
Action has been reassigned to B. Smith on 7/22/96.
1 Sealed Source Safety Section
t J
Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/18/97 For actions recorded as of Friday, July 18,1997 i
Date Assign. #
Received Reviewer Actions Company Model Numbers Status 3/22/96 96-14 Burgess 1 Dept. of the Army M64A1 To Fees on 3/25/96.
Rtmed frm fees on 4/1/96.
Def. Itr sent on 7/22/96.
Resp. revd on 8/6/96.
I 3/25/96 96-16 Burgess 1 Elscint Inc.
CTACT To fees on 3/25/96 Rtmed frm fees on 4/1/96.
Def. call on 8/1/96.
Def. resp. on 8/2/96.
i Def. Itr sent on 8/7/96.
Extension request granted.
(resp. is due on Oct 7,1936.)
Extension request granted -
(resp. due on 10/21/96.)
Resp. revd on 10/22/96.
Def. ltr sent on 1/29/97.
l Def. Itr revd on 3/15/97 i
Def. itr sent on 5/14/97.
Def. resp rcvd on 6/12/97.
Def. call on 6/12/97 Def. resp revd on 6/19/97.
l J
s
. t3 9%
e.
4/24/96 96-35 Compton 1 DMW Geophysical EUDI, TUD1 N/A from fees i
Action has been transferred to E. Compton.
4/24/96 96-33 Compton 2 Industnal Reator Labs Source N/A from fees Action has been transferred to E. Compton.
4/24/96 96-34 Compton 1 Industrial Reator Labs Gauge N/A from fees Action has been transferred to E. Compton.
2 Sealed Source Safety Section
l l-i l
l Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/18/97 For actions recorded as of Friday, July 18,1997 Date Assign. #
Received Reviewer Actions Company Model Numbers Status 4/24/96 96-32 Compton 1 Martin-Marietta LCG-25A N/A from tees Action has been transferred to E. Compton.
4/24/96 96-31 Compton 2 Thiokol Corporation 343812,343814 N/A from fees Def call on 2/21/97.
Def. resp revd on 3/3/97.
Case rtrnd bck to files 4/26/96 96-36 Compton 1 Stock Equipment D26752 To fees on 4/29/96.
Company Rtmed frm fees on 5/3/96.
Action has been transferred to E. Compton.
4/26/96 96-38 Burgess 1 TWA Rigid guide tube To fees on 5/2/96 Rtmed frm fees on 5/21/96.
Additionalinf. revd on 8/26/96.
Working on action w/conjuction w/96-04.
96-04 transfered to MA on 3/97 4/30/96 96-37 Burgess 1 Amencan Airlines Rgid guide tube /collimater To fees on 5/1/96 New Fee ruling Rtmed frm fees on 5/28/96.
Additionalinf. rcvd on 8/26/9C.
Working on action w/conjuction w/96-04 96-04 transfered to MA on 3/97.
l l
l l
l l
3 Sealed Source Safety Section
l t
Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/18/97 For actions recorded as of Friday, July 18,1997 l
Date Assign. #
Received Reviewer Actions Company Model Numbers Status 5/1/96 96-43 Smith 4 ohmart Corporation SHLG/SHN To fees on 04/17/96 Rtrned frm 4/24/96 Reissued a new assign no.
Same as 96-21 Action will be reassigned to Eric Jamer an.
Activn has bee.. reasssigned to B. Smith on 7/22/96.
5/21/96 96-44 Compton 1 Mirtone Industrics, Inc.
73470u To Fees on 6/6/96 Rtrned frm fees on 7/26/96.
Action has been transferred to E. Compton on 4/29/97.
6/3/96 96-45 Smith 3 E I. Company El 100 BUS,100 SUS,100LUS To Fees on 6/6/96 Rtrned frm fees on 7/5/96 Action is with Fred Combs 4/29/97.
Action has been transferred to B. Smith Def. Itr sent on 6/18/97.
1 l
6/10/96 96-48 Broaddus 1 Panasonic industrial WE 2001 Series To Fees on 6/17/96.
Co.
Rtrned frm Fees on 7/26i96.
1 1
6/11/96 96 50 Compton 1 Frank Barker Gammamed 12:
To Fees on 6/19/96.
Associates Rtrned frm fees on 7/26/96.
Action has been transferred from D. Broaddus to E.
Compton.
l l
l 4
Seated Source Safety Section l
l Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/18/97 t
For actions recorded as of Friday, July 18,1997 Date Assign. #
Received -
Reviewer Actions Company Model Numbers Status 8/16/96 06-84 Randall 1 Chrompack inc.
902,902A,902B To Fees on 8/20/96.
Rtmed frm fees on 8/22/96.
Def. call on 2/21/97.
No resp. to def call on 2/21/97 per C. Brown.
Def. Ltr sent m 03/20/97 Action nas been tiansferred to Kim Randall.
8/19/96-96-85 Compton 1 Agfa Corporation BKG 40823-01 To Fees on 8/20/96.
Rtrned frm fees on 8/22/96.
Action is with Fred Combs 4/29/97.
Action has been transferred to E. Compton.
9/25/96 96-87 Burgess 1 Dept. of Agncultuie Husman Irradiator To fees on 9/30/96.
Rtrned frm fees on 10/4/96.
Def. call on 9/25/96.
30 day void Itr sent on 1/17/97.
Resp. revd on 3/5/97.
1 4
1 5
Sealed Source Safety Section
Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/18/97 For actions recorded as of Friday, July 18,1997 Date Assign #
Received Reviewer Actions campany Model Numbers Status l
10/2/96 96-93 Burgess 1 Gray
- Star, Inc, Gray
- Star To Fees on 10/11/96.
Rtmed frm fees on 11/5/96 Additional information rcyd on 11/29/96.
Parned back to Fees on 12/23/96.
Rtmed frm Fees on 12/30/96.
Def. Itr sent on 1/27/97.
Def. ltr rcvd on 4/7/97.
Meeting w/ Gray Star and j
SFPO on 5/7/97.
2 10/4/96 96-91
{
Smith 1 Dept.of the Army M22 ACADA To fees on 10/4/96.
Rtmed frm fees on 11/5/96 l
Def call on 1/10/97 i
Revd partial def resp on j
1/17/97.
Revd partial resp on 2/7/97.
Revd partial resp on 2/19/97.
Revd partial resp on 2/26/97.
Def. ltr sent on 04/7/97.
Revd 2 partial resp. on 4/9/97 and 4/10/97.
Revd partial def. response on 4/25/97.
6 Sealed Source Safety Section
)
Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/18/97 For actions recorded aS of Fr; day, July 18,1907 Uate Assign. #
Received Reviewer Actions Company Model Numbers Status l
10/11/96 96-102 j
Smith 1 IRIS Control CJble Housing To Fees on 10/15/96.
Rtrned frm fees on 11/5/96.
}
Def. call and Ltr sent on 1/9/97.
Partial resp. rcvd on 2/19/97.
30 day ltr sent on 3/24/97.
Resp. revd on 03/28/97.
Def. call on 5/30/97.
10/24/96 96-104
)
Kirkwood 1 Kidde Fenwal, Inc.
CPD 705X Smoke Detector To Fees on 10/25/96.
Rtrned frm fees on 10/30/96.
Def. W 2/20/97.
11/11'96 96-105 Burgess 1 Detection Systems, Inc. DS260 lonizatica Smoke To Fees un 11/14,%
1 Detector Rtrned frm fees on 12/24/96.
Def. call on 1/30/97.
Def. resp. on 1/31/97.
Design change info revd on 4/28/97.
11/14/96 96-106 Smith 1 Apgee Corporaten 31000 Series To Fees c911/14/96.
Action has been transferred to B. Smith 11/14/96 96-107 Broaddus 1 Theratronics 1000E Series To Fees on 11/14/96.
Rtmed frm fees on 11/29/96.
11/14/96 96-108 Broaddus 1 Theratronics 780 Senes To Fees on 11/18/96.
Rtmed frm fees on 11/29/96.
7 Sealed Source Safety Section
l l-t l
Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/18/97 For actions recorded aS of Friday, July 18,1997 Date Assign. #
Received Reviewer Actions Company Model Numbers Status 12/11/96 96-113 Broaddus 14 Safety Light Various To fees on 12/11/96.
Comoration Rtrned frm fees on 1/21/97 12/24/96 96-116 Lubinski 1 Hauni Richmond, Inc.
Sui To Faes ~ 1/6/97.
Resubmittal v. 96-06 (void i
file).
Rtrned frm fees on 1/21/97.
Def. ltr sent on 07/15/97.
l 1/30/97 97-03 l
Compton 2 Hesco Inc.
ML 4167X, ML 404 To Fees on 1/31/97.
t Rtmed frm fees on 2/21/97.
2/5/97 G T-05 Compton 1 IRM TG-2 To fees on 2/6/97.
Rtmed frm fees on 3/14/97.
l 2/25/97 97-07 Smdh 1 Nuclear Research SH-301, SH-302, SH-352 To fees on 2/26/97.
- Corp, Rttned frm fees on 3/3/97.
3/7/97 97-09 Unassigned 1 Ohmart SHRD To fees on 3/7/97.
Rtrned frm fees on 3/18/97.
3/7/07 97-10 Compton 1 SMV Amenca PS 96 To Fees on 3/11/97.
Rtmed frm fees on 3/18/97 3/11/97 97-11 Unassigned 1 Ohmart Corporation SHLM-BX, SHLM-CX, To Fees on 3/11/97.
SHLM.BR SERIES, CR SERIES Rtmed frm fees on 3/18/97.
3/17/97 97 12 l
Compton 1 Brandhurst, Inc.
B100-X Senes To Fees on 3/21/97.
Rtmed frm fees on 4/2/97.
8 Sealed Source Safety Section i
a Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/18/97 For actions recorded as of Friday, July 18,1997 Date Assign. #
Received Reviewer Actions Company Model Numbers Status 3/17/97 97-13 Compton 1 Brandhurst, Inc.
S, CT, CC, RT, RC, DA, DR To Fees on 3/21/97.
Rtined frm fees on 4/2/97.
3/18/97 97-19 Unassigned 1 21st Century Series 100 - 900 To Fees on 3/21/97.
Technologies Rtmed frrr 'ees sn 4/8/97.
3/18/97 97-20 Unassigned 1 BHP Petroleum 130.0 To Fees on 3'"!1/97.
America Rtrned frm fees on 4/2/97.
3/16/97 97 14 Unassigned 6 Brun Sensor Systems, ML-L,35-0101,02 0036-ML-1, To Fees on 3/21/97.
Inc.
ML-1-5, ML-1-4 Rtmed frm fees on 4/2/97.
3/18/97 97-15 Unassigned 5 Brun Sensor Systems,35-201,208,402,403.404.307,10 To Fees on 3/21/97.
Inc.
Rtrned frn fees on 4/2/97.
3/18/97 97 16 Unassigned 2 Capintec, Inc.
CR-168E,154E,178E,164E, To Fees on 3/21/97.
165E,486E Rtrned frm fees on 4/2/97.
3/18/97 97 17 Compton 3 Cumberland Research P,120,120,235, CRC 120A, To Fees on 3/21/97.
Corp.
100 Rtmed frm fees on 4/2/97.
+
w w,
n 3/18/97 97-18 Compten 13 Cumberland Research P, R, AB. VXR,GPL, A-217, To Fees on 3/21/9/.
Corp.
R-100,120, MH, Rtmed frm fees on 4/2/9'/.
3/20/97 97-21 Smith 1 lon Track Instruments Models 27,58,62,70, & 75 To Fees on 3/26/97, See also 94-09 Rtrned frm fees on 4/2/97.
Def. ltr sent on 5/7/97 Partial def resp rcvd on 5/14/97.
9 Sealed Source Safety Section
Pending Sealed Source & Device Actions
' Actions received during the period 1/1/01 to 7/18/97 For actions recorded as of Friday, July 18,1997 b
Date Assign. #
Received Reviewer Acticas Company Model Numbers Status 3/21/97 97-22 Unassigned 1 Isotope Measunng Model 5321 To Fees on 3/26/97 i
Systems Rtmed frm fees on 4/11/97.
3/28/97 97-30 Unassigned 1 CE Medical Systems Model 2180506,
To fees on 4/3/97 Rtmed frm fees on 4/8/97.
l 4/1/97 97-29 i
Unassigned 1 ApoHo Series 60A, XP95A, TP90 To Fees on 4/2/97.
1 Rtrned frm fees on 4/8/97.
4/1/97 97-23 Unassigned 1 FEMA CDV 757 To Fees on 4/2/97.
R!med frm fees on 4/8/97.
I 4/1/97 97-24 Unassigned 1 FEMA CDV 778,782,784,786 To Fees on 4/2/97.
Rtrned frm fees on 4/8/97.
4/1/97 97-25 Unassigned 1 FEMA CDV-794 Model No 2 To Fees on 4/2/97.
Rtrned frm fees on 4/8/97.
4/1/97 97-26 Unassigned 1 FEMA CDV-797 To Fees on 4/2/97.
Rtrned frm fees on 4/8/97.
4/1/97 97-27 Unassigned 1 FEMA CDV-791, CDV 792 To Fees on 4/2/97.
Rtmed frm fees on 4/8/97.
4/1/97 97 28 i
Unassigned i FEMA CDV-790 Model i To Fees on 4/2/97.
Rtmed frm fees on 4/8/97.
4/30/97 97-32 Unassigned 1 mb-microtec 100/1,100/2,100/3 To Fees on 4/30/97.
Rtmed frm fees on 5/7/97.
2 10 Sealed Source Safety Section 4
Pending Sealed Source & Device Actions Actions received during the period 1/1/01 to 7/18/97 For actions recorded aS of Friday, July 18,1997 Date Assign. #
Received Reviewer Actions Ccmpany Model Numbers Status 5/5/97 97-33 Compton 1 Trilux Sights, Inc.
RLP, SG, RHP, FB. FP SERIES To Fees on 5/5/97, Rtrned fm1 fees on 5/7/97.
5/9/97 97 35 Smith 1 Hochiki America Corp.
Sl_ SERIES Reinstatement of 97-04.
To Fees on 5/13/97.
Rtmed frm fees on 5/19/97.
Def. call on 6/18/97.
Revd def. resp on 6/19/97.
5/9/97 97 34 Unassigned 1 PSI Powertronic Dnft Tube Assembly N/A to Fees
2.202 response Fee exempt 5/20/97 97-39 Broaddus 1 Apgee Corporation Model LB 330 To and rtmed frm Fees on 6/3/97.
2.202 response Fee exempt 6/2/97 97 41 Unassigned 1 ES Industres D42 To Fees on 6/4/97.
Rtmed frm fees on 6/10/97.
6/3/97 97-36 Broaddus 1 Apgee Corporation LB 7400 SERIES To and rimed from Fees on 6/3/97.
2.202 response Fee exempt 6/3/97 97-37 Broaddus 1 Apge wiperation LB 300 IPD/L To and rtmed frm Fees on i
6/3/97.
2.202 response Fee exempt 6/12/97 9742 Unassigned 1 Apgee Corporation LB 379 To Fees on 6/12/97.
i Rtrned frm fees on 6/16/97.
11 Sealed Source Safety Section
7 e Pending Sealed Source & Device Actions i
Actions received during the period 1/1/01 to 7/18/97 For actions recorded as of Friday, July 18,1997 Date Assign. #
Received Reviewer Actions Company Model Numbers Status 6/12/97 97-43 Unassigned 1 Apgee Corporation LB 300 ULP To Fees on 6/12/97.
Rtmed frm fees on 6/16/97.
6/12/97 97-44 Unassgned 1 Aegee Corporation LB 300 IRL To Fees or */12/97.
Rtrr.ed frm fee.,an 6/16/97.
6/12/97 97-45 Unassigned 1 Apgee Corporation LB 300 ML/MLT To Fees on 6/12/97.
Rtrned frm fees en 6/16/97.
6/16/97 97-46 Unassigned 1 Apgee Corporation LB 300 ML/MLT To Fees on 6/16/97.
See also 97-45 Rtmed frm fees on 6/W97.
6/17/97 97-47 Unassigned 1 Stocker & Yale P650 To Fees on 6/17/97.
6/20/97 97-48 Unassigned 1 Allegheny Universdy SrO.A53 To Fees on 6/20/97.
Hosp.
6/23/97 97-49 Randall 1 Bicron various To Fees on 6/24/97.
Rtrned frm foes on 7/2/97.
7/8/97 97 51 Unassigned 1 System Sensor 700A To Fees on 7/9/97.
Total Open Case (s)is 75 Totaling 123 Action (s)
I 12 Sealed Source Safety Section