Text
_ _
MF9 Log # TXX-88024 File # 10110 903.8
=
=
Ref.#10CFR50.55(e) 7UELECTRIC wmum c. counsa January 5, 1988 cmon, ur era,,
V. 5. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C.
20555
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)
DOCKET NOS. 50-445 AND 50-446 ROLL-AWAYMISSILESHIELDS(RAMS)
SDAR:
CP-87-30 (INTERIM REPORT)
Gentlemen:
On July 1,1987, we verbally notified your Mr. H. S. Phillips of a deficiency involving errors in the seismic qualification report supplied by the vendor of the Roll-Away Missile Shields (RAMS).
A preliminary review of these errors indicated that RAMS were overstressed for the designed seismic conditions detailed in the applicable specifications.
This is an interim report of a potentially reportable item under the provisions of 10CFR50.55(e).
Our last report was logged TXX-6871, dated October 16, 1987.
We are continuing our evaluation of this issue and will submit our next report by February 5, 1988.
Very truly yours,
()). lo.
W. G. Counsil By:
D. R. Woodlan Supervisor, Docket Licensing BSD/grr c - Mr. R. D. Martin, Region IV Resident inspectors, CPSES (3) 7 p Jt 8801130311 880105
^