Forwards RAI Re Util 930305 Response to NRC Bulletin 90-001, Suppl 1, Loss of Fill-Oil Rosemount Transmitters. Response Requested within 60 Days of Ltr Receipt
ML20149E092
Person / Time
Site: FitzPatrick 
Issue date: 05/20/1994
From: Menning J
Office of Nuclear Reactor Regulation
To: Josiger W
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
References
IEB-90-001, IEB-90-1, TAC-M85389, NUDOCS 9405260217
Download: ML20149E092 (4)


Text

,:

May 20, 1994 Docket No. 50-333 DISTRIBUTION:

Docket File' NRC & Local PDRs PDI-1 Readin'g SVarga Mr. William A. Josiger, Acting JCalvo MBoyle Executive Vice President, Nuclear CVogan JMenning Generation 0GC ACRS (10)

Power Authority of the State of CCowgill, RGN-I NLe, 14/8/20 123 Main Street _

DSpaulding, 8/H/3 New York White Plains, New York 10601

Dear Mr. Josiger:

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION - RESPONSE TO NRC BULLETIN 90-01, SUPPLEMENT 1, " LOSS OF FILL-Oll IN ROSEMOUNT TRANSMITTERS," FOR THE JAMES A. FITZPATRICK NUCLEAR POWER PLANT (TAC N0. M85389)

Supplement I to NRC Bulletin 90-01 was issued on December 22, 1992. This bulletin supplement requested recipients to review the information for applicability to their fac lities and modify, as appropriate, their actions and enhanced surveillance programs for Rosemount transmitters. The Power Authority of the State of New York (PASNY) responded to Supplement 1 to NRC Bulletin 90-01 by letter dated March 5,1993.

The NRC staff has reviewed the information provided in PASNY's response and identified the need for additional information. We, therefore, request that PASNY provide a response to the questions enclosed.

In order to support i

completion of our review in a timely manner, we request a response within 60 days of receipt of this letter.

This requirement affects one respondent and, therefore, is not subject to Office of Management and Budget review under P.L.96-511.

-)

Sincerely, Original signed by:

John E. Menning, Project Manager Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Enclosure:

Request for Additional Information cc w/ enclosure:

See next page.

OFFICE PDielLA PDI-1:PM PDI-1:D CV7gi JMenning l

'MBoyle WE h / O/94 5/2o/94 h/b0/94

/ /

~/ /

DATE OFFICIAL RECORD COPY FILENAME: G:\\FITZ\\ FIT 85389.RAI o.

, n.,

A.t Y u V h.d.

9405260217 940520

' A d bd$ bh PDR ADOCK 05000333 G

PDR

, i

n O

0 e aro,v o-0 4

ff) k UNITED STATES 5 O '2{

J NUCLEAR REGULATORY COMMISSION T"[

/

WASHINGTON, D.C. 20555 0001 May 20, 1994 Docket No. 50-333 Mr. William A. Josiger, Acting Executive Vice President, Nuclear Generation Power Authority of the State of New York 123 Main Street White Plains, New York 10601

Dear Mr. Josiger:

t

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION - RESPONSE TO NRC BULLETIN 90-01, SUPPLEMENT 1, " LOSS OF FILL-OlL IN ROSEM0UNT TRANSlilTTERS," FOR THE JAMES A. FITZPATRICK NUCLEAR POWER PLANT (TAC N0. M85389)

Supplement 1 to NRC Bulletin 90-01 was issued on December 22, 1992. This bulletin supplement requested recipients to review the information for applicability to their facilities and modify, as appropriate, their actions and enhanced surveillance programs for Rosemount transmitters. The Power Authority of the State of New York (PASNY) responded to Supplement 1 to NRC Bulletin 90-01 by letter dated March 5,1993.

The NRC staff has reviewed the information provided in PASNY's response and identified the need for additional information. We, therefore, request that PASNY provide a response to the questions enclosed.

In order to support completion of our review in a timely manner, we request a response within 60 days of receipt of this letter.

This requirement affects one respondent and, therefore, is not subject to Office of Management and Budget review under P.L.96-511.

Sincerely,

[.

John E. Henning, Project Manager Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Enclosure:

Request for Additional Information l

1

~

cc w/ enclosure:

)

See next page

Mr. William A. Josiger, Acting James A. FitzPatrick Nuclear Power Authority of the State of New York Power Plant cc:

Mr. Gerald C. Goldstein Ms. Donna Ross Assistant General Counsel New York State Energy Office Power Authority of the State 2 Empire State Plaza of New York 16th Floor 1633 Broadway Albany, New York 12223 New York, New York 10019 Mr. Richard L. Patch, Acting Resident Inspector's Office Vice President - Appraisal U. S. Nuclear Regulatory Commission and Compliance Services P.O. Box 136 Power Authority of the State Lycoming, New York 13093 of New York 123 Main Street Mr. Harry P. Salmon, Jr.

White Plains, New York 10601 Resident Manager James A. FitzPatrick Nuclear Power Plant P 0. Box 41 Lycoming, New York 13093 Mr. J. A. Gray, Jr.

Director Nuclear Licensing - BWR Power Authority of the State of New York 123 Main Street White Plains, New York 10601 Supervisor Town of Scriba Route 8, Box 382 Oswego, New York 13126 Mr. Robert G. Schoenberger, First Executive Vice President and Chief Operating Officer Power Authority of the State of New York 123 Main Street White Plains, New York 10601 Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, New York 10271 Regional Administrator, Region I 1

U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, Pennsylvania 19406

ENCLOSURE RE0 VEST FOR ADDITIONAL INFORMATI0tf FITZPATRICK RESPONSE TO NRC BULLETIN 90-01. SUPPLEMENT 1 1.

The Power Authority of the State of New York's (PASNY's) response dated March 5, 1993, stated that the once per operating cycle calibration drift monitoring program will continue for at least the next two operating cycles for those Rosemount transmitters exposed to normal operating pressures below 500 psig and for those that have reached the maturity (psi-month) threshold criterion.

How will PASNY maintain a high degree of confidence in the performance of these transmitters beyond this monitoring period as requested in Items 1.e and 1.f of the bulletin supplement?

2.

Does the enhanced surveillance monitoring program described in of PASNY's response meet the accuracy requirements of Rosemount Technical Bulletin No. 47 3.

Have the 22 transmitters that required an additional 12 days of exposure to normal operating pressure to reach the 60,000 psi-month maturity threshold reached this threshold at this time?