._
M 2:L" '""'
Log # Txx-88051 d
File # 10110
=
908.3
" # IOC O'
'}
TUELECTRIC r
1 wmiam c. coonsa January 8, 1988 Easwise We Pres &nt i
- 6. 3. Nuclear Regulatory Conunission Attn: Document Control Desk Washington, D. C.
20555
SUBJECT:
COMANCliE PEAK STEAM ELECTRIC STATION (CPSES)
DOCKET N05, 50-445 AND 50-446 t
MCC STARTER C0ILS SDAR: CP-87-93 (INTERIM REPORT)
Gentlemen:
i On September 3,1987, we verbally notified your Mr. H. S. Phillips of a deficiency involving MCC starter coils which may not pick up at minimum bus voltage.
This is an interim report of a potentially reportable item under the l
provisionsof10CFR50.55(e). Our latest report submitted was logged TXX-6788, dated October 5, 1987.
We are continuing our evaluation of this issue and will submit our next report l
by April 1, 1988.
L Very trmly yours, j
i l
W. G. Counsil
'l By:
30% W. Beck Vice President, Nuclear Engineering WJH/grr 1
c - Mr. R. D. Martin, Region IV Resident inspectors, CPSES (3) 3 i
8801130194 880108 GDR ADOCK 0500M45
{
{
i S
400 &nh Olise Street LB BI Dalta, Tetas 7N 01
}O c
,