ML20149D982

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept CP-87-08 Re Calibr Accuracy for Dead Weight Tester Used as Std in Calibr Pressure Instrumentation.Initially Reported on 870420.Evaluation Continuing.Next Rept to Be Submitted by 880306
ML20149D982
Person / Time
Site: Comanche Peak  
Issue date: 01/06/1988
From: Counsil W, John Marshall
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
CP-87-08, CP-87-8, TXX-88037, NUDOCS 8801130181
Download: ML20149D982 (1)


Text

M 1"""

Log # TXX-88037

.-~

Fi1e # 10110 r

C 907 Ref. # 10U R50.55(e) 1UELECTRIC i

William G. Counsil em.,,,, ru, erum,,

January 6, 1988 j

5 i

U. S. Nuclear Regulatory Commission Attn: Document Control Desk j

Washington, D. C.

20555

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

[

DOCKET NOS. 50-445 AND 50-446 CALIBRATION ACCURACY OF PRESSVRE STANDARD (DEAD WEIGHT TESTER)

SDAR: CP-8-08 (INTERIM REPORT)

Gentlemen:

On April 20, 1987, we verbally notified your Mr. Cliff Hale of a deficency rega'. ding the calibration accuracy for a Dead Weight Tester used as a standard v

in calibrating pressure instrumentation.

1his tester has been used in the Operations (Instrumentation & Controls) test / maintenance program.

This is an interim report of a potentially reportable item under the provisions of 10CFR50.55(e). Our latest report was logged TXX-6870, dated October 21, 1987.

We are continuing our evaluation and will provide our next report by March 6, 1988.

j Very truly yours, (U. G. Co u s s, l t

W. G. Counsil

[

By:

J. S. Marshall l

Supervisor, Generic Licensing BSD/grr c - Mr. R. D. Martin, Region IV Resident inspectors, CPSES (3) 8801130181 000 j45 PDR ADOCK PDR S

f f p an s.,,8 on.,s,cae, u n ua,. ran, um