ML20149D935

From kanterella
Jump to navigation Jump to search
Forwards Response to NRC Compliance Bulletin 87-002, Fastener Testing to Determine Conformance W/Applicable Matl Specs. Description of Receipt Insp Practices & Internal Controls for Fasteners Encl
ML20149D935
Person / Time
Site: Calvert Cliffs  
Issue date: 01/29/1988
From: Tiernan J
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
IEB-87-002, IEB-87-2, NUDOCS 8802100109
Download: ML20149D935 (49)


Text

S ALTIMORE GAS AND ELECTRIC CHARLES CENTER P. O. BOX 1475 BALTIMORE, MARYLAND 21203 JostPH A.TIERNAN Vice PntslOENT Nuct[Am ENERQY January '.9,1988 U. S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:

Document Control Desk

SUBJECT:

Calvert Cliffs Nuclear Power Plant Unit Nos.1 & 2; Docket Nos. 50-317 & 50-318 Fasten'r_Testina

REFERENCE:

(a) NRC Compliance Bulletin No. 87-02: Fastener Testing to Determine Conformance with Applicable Material Specifications Gentlemen:

The attachments that follow provide the information you requested from us in NRC Compliance Bulletin No. 87-02 (Reference a).

Attachment (1) provides the supporting information for each tested fastener in the format you gave us in Attachment 1 of the bulletin. We added a few fields such as, "Mech. No." and "Purchase Order No." to aid us in tracking the fasteners.

Attachment (2) contains the test results in several tables that are comparable to the format you gave us in Attachment 2 of the bulletin. Table No. 5 of Attachment (2) lists properties found out-of-specifica!!on along with an evaluation of the safety 1

significance.

Attachment (3) describes our receipt inspection practices and our internal controls for fasteners.

9802100109 000129 PDR ADOCK 05000317 i

G PDR l

Document Control Desk January 29, 1988 Page 2 i

i We hope the information we provide will aid you in your investigation. If we can i

provide you with additional information on fasteners usea at Calvert Cliffs, do not hesitate to contact us.

Very truly yours, l

l l

1 STATE OF MARYLAND :

i TO WIT-COUNTY OF CALVERT

)

I hereby certify that on the n day of AuLtu. NN, before me the

,ubscriber, a Notary Public of the State of hiaryland in and fof ' CJ&t G 't 0/Md personally appeared Joseph A. Tiernan, being duly sworn, and states' that he is Vice President of the Baltimore Gas and Electric Company, a corporation of the State of 1

hfaryland; that he provides the foregoing response for the purposes therein set forth; that the statements made are true and correct to the best of his knowledge, information, and belief; and that he was authorized to provide the response on behalf of said Corporation.

WITNESS my Hand and Notarial Scal:

/A>J

- /7e CMy Notary Public y

My Commission Expires:

hizAt4. /, /Nd 6 Date i

JAT/WPhf/ dim Attachments cc:

D. A. Brune, Esquire J. E.

Silberg, Esquire R. A.Capra NRC S. A.hicNeil,NRC W. T Rt'ssell, NRC D. C. Trimble, NRC i

I

ATTACHMENT (1) i FASTENERTESTING DATA SIIEETS NOTE:

Explanation of classification system used for "Class / Procurement Level' in data shee3 that follow:

)

i l

l l

BG&f: Socc. XXX. Part 21 Anolies - Purchase controlled by a specification package that invoked the requirements of 10 CFR 21 on suppliers.

1 Commercial Ouality (Safety Related) - Method of purchase used when a commercial quality l

item is adequate for a particular safety-related purpose and has the necessary safety-related characteristics. Special requirements are not specified and a formal QA Program is not required.

l Commercial Ouality - Same as above, but for non-safety related purchases.

Catalon Purchase - Method of purchase that may be used to obtain mass-produced safety-i related items that can be selected from a sales catalog, bill of materials, drawing, etc.

i

c ATTACHMENT (1)

FASTENERTESTING DATA SHEET Sample ID No. CCNPP-A(F)

Mech No.: 75-P32 SRI Tag No.: 495980-E Fastener

Description:

Rod, All Thread, 1-3/8" x. 6 TPI Purchase Order No. 97894 GX Date: 05-05-87 Description of Sample Stock Location: Warehouse #3, 31N36A2 Material Specification as Documented by Licensee Records: SA 193 Gr B7 Ilead Marking:

H M

CbM Class / Procurement Level: BG&E Spec. 546 Rev. O Part 21 Applies i

General Phnt Application: General Plant Use j

I Vendor: A&G Engineering Co., 4640 E. LaPalma Ave., Anaheim CA 92807 QA Requirements imposed on Vendor: 10 CFR 50 Appendix B, ANSI N45.2, ASME Section ill i

Licensee Representative:

Signature

/

Date /

A v

v~

g g - -,

ATTACHMENT (1)

FASTENERTESTING DATA SilEET Sample ID No. CCNPP-A(N)

Mech No.: 75-P13 SRI Tag No.: 490253-E Fastener

Description:

Nut, 1-3/8" x 6 TPI Purchase Order No. 97894 GX Date: 05-05-87 Description of Sample Stock Location: Warehouse #2, 21D056C Material Specification as Documented by Licensee Records: SA 194 Gr 2H llead Marking:

R E.7

'I T

Class / Procurement Level: BG&E Spec. 546 Rev. O, Part 21 Applies General Plant Application: General Plant Use Vendor: A&G Engineering Co., 4640 E. LaPalma Avenue, Anaheim, CA 92807 QA Requirements Imposed on Vendor: 10 CFR 50 Appendix B, ANSI N45.2, ASME Section ill Licensee Representative:

Signature I

1 i

.A t

Date /,

r I

ATTACilMENT (D FASTENERTESTING DATA SilEET Sample ID No. CCNPP-B(F)

Mech No.: 75-P33 SRI Tag No.: 495970-E Fastener

Description:

Rod, All Thread, 1-1/2" x 6 TPI Purchase Order No. 97894 GX Date: 05-05-87 Description of Sample Stock Location: Warehouse #3, 31N34Al Material Specification as Documented by Licensee Records: SA 193 Gr B7 liead Marking:

(--)

67 cdd Class / Procurement Level: BG&E Spec. 546 Rev. O, Part 21 Applies General Plant Application: General Plant Use Vendor: A&G Engineering Co.,4640 E. LaPalma Avenue, Anaheim, CA 92807 QA Requirements Imposed on Vendor: 10 CFR 50 Appendix B, ANSI N45.2, ASME Section 111 Licensee Representative:

Signature

.k rW Date

/ th3 ATTACHMENT (1)

FASTENER TESTING DATA SIIEET Sample ID No.CCNPP-B(N)

Mech No.: 75-P14 SRI Tag No.: 495874-E Fastener

Description:

Nut, 1-1/2" x 6 TPI Purchase Order No. 97894 GX Date: 05-05-87 Description of Sample Stock Location: Warehouse v42, 21DO44B I

Material Specification as Documented by Licensee Records: SA 194 Gr 211 IIead Marking:

GC6 7

T Class / Procurement Level: BG&E Spec. 546 Rev. O, Part 21 Applies General Plant Application: General Plant Use Vendor: A&G Engineering Co., 4640 E. La!.ima Avenue, Anaheim, CA 92807 QA Requirements imposed on Vendor: 10 CFR 50 Appendix B, ANSI N45.2, ASME Section 111 Licensee Representative:

[

Signature

,/ //

W Date

/

4 4

5

ATTACllMENT (1)

FASTENERTESTING DATA SliEET I

Sample ID No. CCNPP-C(F)

Mech No.: 75-P26 SRI Tag No.: 476391-E Fastener Dcscription: Rod, All Thread, 3/4" x 10 TPI x 6' long Purchase Order No. 03133 GX Date: 08-18-87 Description of Sample Stock Location: Warehouse #3, 31N36 fit Material Specification as Documented by Licensee Records: SA 193 Gr B7 Head Marking:

H B7 btC Class / Procurement Level: BG&E Spec. 546 Rev.1 Part 21 Applies i

General Plant Application: General Plant Use Vendor: A&G Engineering Co., 4640 E. LaPalma Avenue. Anaheim, CA 92807 QA Requirements imposed on Vendor.10 CFR 50 Appendix B, ANSI N45.2 ASME Section til Licensee Representative:

Signature A

Date /

9

.w ATTACilMENT (11 FASTENERTESTING DATA SIIEET Sampla ID No.CCNPP-C(N)

Mech No.: 75-P16 SRI Tag No.: 479701-B (typical)

Fasten'er

Description:

Nut, Heavy Hex, 3/4" x 10 TPI Purchase Order No. 07225 GX Date: 11-13-87 Description of Sample Stock L.ocation: Warehouse #2, 21D055H Material Specification as Documerted by Licensee Records: SA 194 Gr 2H i

Head Marking:

2R Class / Procurement Level: BG&E Spec. 546 Rev.1, Part 21 Applies General Plant Application: General Plant Use Vendor: A&G Engineering Co., 4640 E. LaPalma Avenue, Anaheim, CA 92807 QA Requirements imposed on Vendor: 10 CFR 50 Appendix B, ANSI N45.2, ASME Section 111 Licensee Repre;entative:

Signature iA V

Date

/

1 7

6 I

ATTACllMENT (1)

FASTENER TESTING DATA SIIEET -

Sample ID No.CCNPP-D(F)

Mech No.: 75-P27 SRI Tag' No.: 495925-E Fastener

Description:

Rod, All Thread, 7/8' x 9 TPI x 6' long Purchase Order No. 97894 GX Date: 05-05-87 Description of Sample Stock Location: Warehouse #3, 31N36F2 Material Specification as Documented by Licensee Records: SA 193 Gr B7 Head Marking:

Nm bt /

Class / Procurement Level: BG&E Spec. 546 Rcv.1, Part 21 Applies General Plant Application: General Plant Use Vendor: A&G Engineering Co.,4640 E. LaPalma Avenue, Anaheim, CA 92807 QA Requirements imposed on Vendor: 10 CFR 50 Appendix B, ANSI N45.2, ASME Section til Licensee Representative:

Signature k

V Date

/M I

1

-7

s-ATTACHMENT (1)

FASTENER TESTING DATA SHEET Sample ID No.CCNPP-D(N)

Mech No.: 75-P08 SRI Tag No.: 495887-E Fastener

Description:

Nut, 7/8" x 9 TPI Purchase Order No. 00370 GX Date: 05-21-87 Description of Sample Stock Location: Warehouse #2, 21D057B Material Specification as Documented by Licensee Records: SA 194 Gr 2H Head Marking:

H 4 AMb 2R Class / Procurement Level: BG&E Spec. 546 Rev.1. Part 21 Applies General Plant Application: General Plant Use i

Vendor: A&G Engineering Co.,4640 E. LaPalma Avenue, Anaheim, CA 92807 QA Requirements imposed on Vendor: 10 CFR 50 Appendix B, ANSI N45.2, ASME Section 111 Licensee Representative:

Signature Date

/,

\\-

ATTACIIMENT (1)

FAKTENERTESTING DATA SilEET Sample ID No.CCNPP-E(F)

Mech No.: 75-P28 SRI Tag No.: 495933-E-Fastener

Description:

Rod, All Thread, ~ l' x 8 TPI x 6' long Purchase Order No. 97894 GX Date: 05-05-87 Description of Sample Stock Location: Warehouse #3, 31N36G1 Material Specification as Documented by Licensee Records: ASME SA 193 Gr B7 IIead Marking:

(~-)

M hLY Class / Procurement Level: BGAE Spec. 546 Rev.1. Part 21 Applies General Plant Application: General Plant Use Vendor: A&G Engineering Co.,4640 E. LaPalma Avenue, Anaheim, CA 92807 QA Requirements imposed on Vendor: 10 CFR 50 Appendix B, ANSI N45.2, ASME Section ill Licensee Representative:

1

/,

Signature A

Date 7

1

't 1

ATTACHMF,NT (1)

FASTENERTESTING DATA SilEET Sample ID No.CCNPP-E(N)

Mech No.: 75-P09 SRI Tag No.: 495042-E Fastener

Description:

Nut, l' x 8 TPI Purchase Order No. 97894 GX Date: 05-05-87 Description of Sample Stock Location: Wr.rehouse #2, 21D056C hiaterial Specification as Documented by Licensee Records: SA 194 Gr 2H liead hfarking:

H h?AC zu Class / Procurement Level: BG&E Spec. 546 Rev.1, Part 21 Applies General Plant Application: General Plant Use Vendor: A&G Engineering Co.,4640 E. LaPalma Avenue Anaheim, CA 92807 QA Requirements imposed on Vendor: 10 CFR 50 Appendix D, ANSI N45.2, ash 1E Section III Licensee Representative:

Signature W

~

Date

/

ATTAC11 MENT (1)

FASTENER TESTING DATA SilEET i.

Sample ID No.CCNPP-F(F)

Mech No.: 75-P29 SRI Tag No.: 495814-E Fastener

Description:

Rod, All Thread,1-1/8" x 7 TPI

~ Purchase Order No. 97894 GX Date: 05-05-87 3

Description of Sample Stock Location: Warehouse #3, 31N36DI Material Specification as Documented by Licensee Records: SA 193 Gr B7 l'

Head Marking:

H

%7 i

LbX Class / Procurement Level: BG&E Spec. 546 Rev.1. Part 21 Applies General Plant Application: General Plant Use Vendor: A&G Engineering Co.,4640 E. LaPalma Avenue. Anaheim, CA 92807 1

QA Requirements Imposed on Vendor: 10 CFR 50 Appendix B, ANSI N45.2, ASME Section 111 Licensee Representative:

L Signature h..

Date

/,

I t

I ATTACHMENT (1)

FASTENERTESTING DATA SHEET Sample ID No.CCNPP-F(N)

Mech No.: 75-P10 i

i SRI Tag No.: 495887-E Fastener

Description:

Nut, 1-1/8" x 7 TPI Purchase Order No. 97894 GX Date: 05-03-87 Description of Sample Stock Location: Warehouse #2, 21D052C Material Specification as Documented by Licensee Records: SA 194 Gr 7 -

l Head Marking:

H A

EC D l

Class / Procurement Level: BG&E Spec. 546 Rev. O, Part 21 Applies General Plant Application: General Plant Use l

Vendor: A&G Engineering Co.,4640 E. LaPalma Avenue Anaheim, CA 92807 l

QA Requirements imposed on Vendor: 10 CFR 50 Appendix B, ANSI N45.2 ASME Section 111 Licensee Representative:

?

Signature

~

D1te

/

\\

l L

ATTACHMENT (1)

FASTENERTESTING DATA SilEET Sample ID No.CCNPP-G(F)

Mech No.: 75-P30 SRI Tag No.: 481141-E Fastener

Description:

Rod, All Thread,1-1/4" x 7 TPI Purchase Order No. 07225 GX Date: 11-13-87 Description of Sample Stock Location: Warehouse #3, 31N36Cl Material Specification as Documented by Licensee Records: SA 193 Gr B7 Head Marking:

6 B7 bLR Class / Procurement Level: BG&E Spec. 546 Rev.1, Part 21 Applies General Plant Application: General P! ant Use Vendor: A&G Engineering Co.,4640 E. LaPalma Avenue, Anaheim, CA 92807 QA Requirements imposed on Vendor: 10 CFR 50 Appendix B, ANSI N45.2, ASME Section III Licensee Representative:

i Signature d;

Date /

/

i

ATTACHMENT (1)

FASTENER TESTING DATA SHEET Sample ID No.CCNPP-G(N)

Mech No.: 75-Pl1 SRI Tag No.: 500282-E Fastener

Description:

Nut, Heavy llex,1-1/4" x 7 TPI Purchase Order No. 07225 EX Date: 11-13-87 Description of Sample Stock Location: Warehouse #2, 21DO5511 Material Specification as Documented by Licensee Records: SA 194 Gr 211 IIead Marking:

G E92.

rT Class / Procurement Level: BG&E Spec. 546 Rev. 1, Part 21 Applies General Plant Application: General Plant Use Vendor: A&G Engineering Co.,4640 E. LaPalma Avenue Anaheim, CA 92807 QA Requirements Imposed on Vendor: 10 CFR 50 Appendix B, ANSI N45.2, ASME Section III Licensee Representative:

Signature

//

Date

/

4 i,

ATTACilMENT (1)

FASTENERTESTING DATA SIIEET t

Sample ID No.CCNPP-H(F)

Mech No.: 75-P31 SRI Tag No.: 495841-E Fastener

Description:

Rod, All Thread,1-1/4" x 8 TPI Purchase Order No. 97894 GX Date: 05-05-87 Description of Sample Stock Location: Warehouse #3, 31N34C2 i

i Material Specification as Documented by Licensee Records: SA 193 Gr B7 IIead Marking:

H 1

B~T CDL Class / Procurement Level: BG&E Spec. 546 Rev. O, Part 21 Applies General Plant Application: General Plant Use I

Vendor: A&G Engineering Co.,4640 E. LaPalma Avenue Anaheim, CA 92807 QA Requirements Imposed on Vendor: 10 CFR 50 Appendix B. ANSI N45.2, ASME Section til Licensee Repiesentative:

d c

vih

/,

Signature Date

- is -

ATTACHMENT (1)

FASTENERTESTING DATA SiiEET Sample ID No.CCNPP-II(N)

Mech No.: 75-P12 SRI Tag No.: 491428-E Fastener

Description:

Nut, 1-1/4" x 8 TPI Purchase Order No. 97894 GX Date: 05-05-87 Description of Sample Stock Location: Warehouse #2, 21D054F Material Specification as Documented by Licensee Records: SA 194 Gr 7 Ilead Marking:

f-)

  • Q 7

Class / Procurement Level: BG&E Spec. 546 Rev. O, Part 21 Applies General Plant Application: General Plant Use Vendor: A&G Engineering Co.,4640 E. LaPalma Avenue Anaheim, CA 92807 QA Requirements imposed on Vendor: 10 CFR 50 Appendix B, ANSI N45.2, ASME Section 111 Licensee Representative:

Signature C

Date

/

[

/

' ~

s _

ATTACHMENT (11-FASirENERTESTING DATA SHEET Sample ID No. CCNPP-l(F) hiech No.: 90-509 SRI Tag No.: 0299-A Fastener

Description:

Stud, 3/4" x 6' long, Atlas Job No.1747 Purchase Order No. 68172D Date: 09-29-72 Description of Sample Stock Location: Warehouse #2, 21G050E hiaterial Specification as Documented by Licensee Records: SA 193 Gr B6, Type 410 1

Head hiarking:

BG Class / Procurement Level: BG&E Spec. 546 Rev, 0, Part 21 Applies General Plant Application: Tube Sheet to Flange for Spent Fuel Pool Heat Exchangers Vendor: Atlas Industrial blanufacturing Company, 81 Somerset Place, Clifton, NJ 97012 QA Requirements imposed on Vendor: Nuclear Certification required ChiTR from Hackensack Bolt and Nut Company in file I

Licensee Representative:

i AA

.I h

/(\\

Signature Date

/

i ATTACHMENT (1)

FASTENERTESTING DATA SHEET Sample ID No.CCNPP-I(N)

Mech No.: 90-509 SRI Tag No.: 0299-A j

i Fastener

Description:

Nut, Hex, 3/4", Atlas Job No. 1747 Purchase Order No. 68172D Date: 09-29 a Description of Sample Stock Location: Warehouse #2, 21G050E Material Specification as Documented by Licensee Records: SA 194 Gr 6F, Type 416 liead Marking:

6 l

Class / Procurement Level: BG&E Spec. 546 Rev. O, Part 21 Applies 1

General Plant Application: Tube Sheet to Flange for Spent Fuel Fool Heat Exchancers Vendor: Atlas Industrial Manufacturing Company, 81 Somerset Place, Clifton, NJ 97012 i

QA Requirements imposed on Vendor: Nuclear Certification required CMTR from llackensack Bolt and Nut Company in file Licensee Representative:

r Signature Date /

3 c i

2 ATTACHMENT (1)

FASTENERTESTING DATA SHEET l

Sample ID No. CCNPP-J(F)

Mech No.: 59-X51 l

SRI Tag No.: 486626-E l

Fastener

Description:

Capscrew, Hex Head,1-1/2" x 8 TPI x 11" long Purchase Order No. 93117 MX Date: 12-22-86 Description of Sample Stock Location: Warehouse #2, 21E047B Material Specification as Documented by Licensee Records: SA 540 Grade B23, Class 4 Head Marking:

H BIS

\\DKL l

Class / Procurement Level: BG&E Spec. 444 Rev. O, Part 21 Applies l

General Plant Application: RCP Vapor Seal, Seal Flange Bolting Vendor: A&G Engineering Co.,4640 E. LaPalma Avenue, Anaheim, CA 92807 l

l QA Requirements imposed on Vendor: 10 CFR 50 Appendix B, ASME Section 111 l

Licensee Representative:

I by g4~

Signature Date

./

l l

\\

! l

A'ITACitMENT (1)

FASTENERTESTING DATA SilEET Sample ID No.CCNPP-K(F)

Mech No.: 72-297 SRI Tag No.: 380854-E (typical)

Fastener

Description:

Rod All Thread, 3/4" x 10 TPI Purchase Order No. 80336 GX Date: 02-06-86 Description of Sample Stock Location: Warehouse #3, 31P0346 Material Specification as Documented by Licensee Records: A 193 Gr B7 Ilead Marking:

igiced Rcb e

j wruts T

tar J

l Class / Procurement Level: Commercial Quality (Safety Related)

{

General Plant Application: General P! ant Use Vendor: A&A Bolt and Screw, 8800 Delso Drive, Baltimore, MD 21221 QA Requirements imposed on Vendor: Commercial item t

Licensee Representative:

d, l

Signature

' V Date

/

i -

y ATTACllMENT (1)

FASTENERTESTING DATA SilEET Sample ID No.CCNPP-K(N)

Mech No.: 78-397 SRI Tag No.: 412914-E (typical)

Fastener

Description:

Nut, liex, 3/4" x 10 TPI, Plated Finish, Ileavy Series t

Purchase Order No. 74864GX Date: 10-14-85 Description of Sample Stock Location: Warehouse #2,- 24F083D Material Specification as Documented by Licensee Records: A 194 Gr 211 Ilead Marking:

H 2H E

Class / Procurement Level: Commercial Quality (Safety Related) i General Plant Application: General Plant Use Vendor: Kenneth G. Lilly Fasteners, P. O. Box 6005, Newark, DE 19711 i

QA Requirements imposed on Vendor: Commercial item Licensee Representative:

j Signature 64V Date /

1 y-i i

4 -

MIACliMENT (1)

FASTENERTESTING DATA SHEET Sample ID No.CCNPP-L(F)

Mech No.: 59-X05 SRI Tag No.: 485100-E Fastener

Description:

Bolt, 7/8" x 9 TPI x 3' Purchase Order No. 80255 GX Date: 03-04-86 Description of Sample Stock Location: Warehouse #2, 21G061 A Material Specification as Documented by Licensee Records: A 193 Gr B7 Head Marking:

3 b'7 l

Class / Procurement Level: Commerical Quality (Safety Related)

General Plant Application: General Plant Use Vendor: Mil-Spec Fasteners, Route 30, Box 59A, llampstead, MD 21074 i

QA Requirements Imposed on Vendor: Commercial item Licensee Representative:

/)r i p

/f AA Signature v

~

Date t

4 l

ATTACHMENT fI)

FATFENERTESTING DATA SHEET Sample ID No.CCNPP-L(N)

Mech No.: 78-398 SRI Tag No.: 412915-E (typical)

Fastener

Description:

Nut, Hex, 7/8" x 9 TPI, Plated Finish, Heavy Series Purchase Order No. 74864 GX Date: 10-14-85 Description of Sample Stock Location: Warehouse

  • 2, 21G024B Material Specificatica as Documented by Licensee Records: A 194 Gr 211 Head Marking:

H u

Class / Procurement Level: Commercial Quality (Safety Related)

General Plant Application: General Plant Use Vendor: Kenneth G Lilly Fasteners, P. O. Box 6005, Newark, DE 19711 QA Requirements Imposed on Vendor: Commercial item Licensee Representative:

Signature Date /M s

ATTACllMENT (1)

FASTENERTESTING DATA SilEET Sample ID No.CCNPP-M(F)

Mech No.: 59-X%

SRI Tag No.: 488557-E Fastener

Description:

Bolt, Heavy Hex IIcad, l' x 8 TP! x 4-l/2" long, Plated Finish Purchase Order No. 94194 GX Date: 01-19-87 Description of Sample Stock Location: Warehouse #2, 21G066A Material Specification as Documented by Licensee Records: A 193 Gr B7 Head Marking:

b'T Class / Procurement Level: Commercial Quality (Safety Related)

General Plant Application: General Plant Use Vendor: A&A Bolt and Screw, 8800 Kelso Drive, Baltimore, MD 21221 QA Requirements imposed on Vendor: Commercial item Licensee Representative:

Signature

/

ID Date / L

ATTACilMENT (1)

FASTENERTF5FING DATA SHEET I

Samph ID No.CCNPP-M(N)

Mech No.: 72-334 SRI Tag No.: 412910-E (typical)

I Fastener

Description:

Nut. Hex, l' x 8 TPI, Plated Finish Purchase Order No. 74864 GX Date: 10-14-85 Description of Sample Stock Location: Warehouse #2, 21D049D 3

Material Specification as Documented by Licensee Records: A $63 Gr A I

Ilead Marking: None l

Class / Procurement Level: Commercial Quality (Safety Related)

General Plant Application: General Plant Use l

Vendor: Kenneth G. Lilly Fasteners, P. O. Box 6005, Newark DE 19711 QA Requirements imposed on Vendor: Commercial item Licensee Representative:

f Signature bk Date _/

i j

AT. rACHMENT (1) l FASTENERTFSTING DATA SHEET Sample ID No.CCNPP-N(F)

Mech No.: 72-298 SRI Tag No.: 470621-E Fastener

Description:

Rod, All Thread, 7/8' x 9 TPI i

Purchase Order No. 01750 GX Date: 06-25-87 i

Description of Sample Stock Location: Warehouse #3, 31P034F Material Specification as Documented by Licensee Records: A 193 Gr B7 I

l l

Head Marking: None

(

l 1

i Class / Procurement Level: Commercial Quality (Safety Related)

General Plant Application: General Plant Use

]

i Vendor. A&A Bolt and Screw, 8800 Kelso Drive, Baltimore, MD 21221 OA Requirements Imposed on Vendor. Commercial item Licensee Representative:

Signature

,/

/,

A Date i 4

ATTACHMENT f1)

FASTENERTESTING DATA SHEET T

Sample ID No.CCNPP-N(N)

Mech No.: 72-333 SRI Tag No.: N/A Fastener

Description:

Nut, Hex, 7/8" x 9 TPI, Plated Finish Purchase Order No. 95481 GX Date: 03-06-87 Description of Sample Stock Location: Warehouse #2, 21H026D Material Specification as Documented by Licensee Records: A $63 Gr A Head Marking: None Class / Procurement Level: Commercial Quality (Safety Related)

General Plant Application: General Plant Use Vendor: A&A Bolt and Screw, 8800 Kelso Drive, Baltimore, MD 21221 i

QA Requirements imposed on Vendor: Commercial item Licensee Representative:

)

Signature k

Date /,

,T

, z _i-

- 27

t ATTACitMENT (1)

FASTENERTESTING DATA SHEET Sample ID No.CCNPP-O(F)

Mech No.: 75-E42 SRI Tag No.: 429918-E Fastener

Description:

Stud, Casing, 7/8' x 9 TPI x 3-1/4", Terry P/N 13477 Purchase Order No. 77246 MX Date: I l-20-85 Description of Sample Stock Location: Warehouso #2, 21E038H Material Specification as Documented by I.icensee Records: A 193 Gr B7 I

Ilead Marking:

i N1 j

i R

4 J

i Class / Procurement Level: Catalog Purchase (Safety Related)

General Plant Application: Auxiliary Feedwater Pumps i

Vendor: Terry Turbine Corporation, Lamberton, Road, P. O. Box 555 Windsor, CT 06095 QA Requirements Imposed on Vendor: 10 CFR 50 Appendix B

?

]

Licensee Representative:

i Signature

!A Date

/

)

\\

'l l

1 1

ATTACHMENT (1)

FASTENERTESTING DATA SHEET Sample ID No.CCNPP-O(N)

Mech No.: 78-398 SRI Tag No.: 412915-E (typical)

Fastener

Description:

Nut, Hex, 7/8' x 9 TPI, Plated Finish, ficavy Series l

Purchase Order No. 74864 GX Date: 10-14-85 Description of Sample Stock Location: Warehouse #2, 21G024B l

Material Specification as Documented by Licensee Records: A 194 GR 211 llead Marking:

H N

l Class / Procurement I.evel: Commercial Quality (Safety Related)

General Plant Application: General Plant Use Vendor: Kenneth G. Lilly Fasteners, P. O. Box 6005, Newark, DE 19711 QA Requirements Imposed on Vendor: Commercial item Licensee Representative:

Signature k.

M 7

Date,/

ATTACHMENT f1)

FAS1ENERTESTING DATA SHEET l

i l

Sample ID No.CCNPP-P(F)

Mech No.: 72-120 SRI Tag No.: 439731-E (typical)

Fastener

Description:

Capscrew Hex, 3/8" x 18 TPI x 2-1/2" lon;;, Plated Finish l

Purchase Order No. 81904 GX Date: 04-l l-86 l

Description of Sample Stock Los stion: Warehouse #2, 21D050A 1

l l

Material Specification as Docum4nted by Licensee Records: S.A.E. Grade 5, liigh Carbon Steel Heat Treated llead Marking:

K.Y N/

\\/

Class / Procurement Level: Commercial Quality (D.fety Related)

General Plant Application: General Plant Use l

Vendor: Kenneth G. Lilly Fasteners, P. O. Box 6005, Newark, DE 19711 QA Requirements imposed on Vendor: Commercial Item Licensee Representative:

./,

Signature.

A.

Date l

ATTACHMENT fIi FASTENERTEK11NO DATA SHEET t

Sample ID No.CCNPP-P(N)

Mech No.: 78-F65 SRI Tag No.: 427200-E f

Fastener

Description:

Nut. Hex, 5/8' x 18 TPI, Plated Finished Double Chamfer Purchase Order No. 80255 GX Date: 03-04-86 Description of Sample Stock Location: Warehouse #2, 21D061G Material Specification as Documented by Licensee Records: A 194 Gr 211 Ilead Marking:

J 24 Class / Procurement Level: Commercial Quality (Safety Related)

General Plant Application: General Plant Use i

Vendor: Mil-Spec Fasteners Rt. 30. Box 59A, llampstead, MD 21074 QA Reguliements Imposed on Vendor: Comraercial item Licensee Representative:

A t

A Y "

l I

1,

ATTACitMENT (1, FASTENERTESTING DATA MIEET SampleIDNo CCNPP-Q(F)

Mech No.: 75-E59 SRI Tag No.: 421428-E Fastener

Description:

Bolt, Hex liend,1-1/4" x 7 UNC x 9' lons i

Purchase Order No. 67871 GX Date: 05 03-85 i

Description of Sample Stock Location: Warehouse #2, 21D063B I

Material Specification as Documented by Licensee Records: A 325, Type t Ilead Marking:

1 M2r Class / Procurement Level: Commercial Quality (Safety Related) 4 i

l General Plant Applict.tlon: Reactor Coolant Pump Motor Hold Down

)

q Vendor. A&A Bolt and Screw, 3800 Kelso Drive, Baltimore, MD 2:221 l

4 l

QA Requirements imposed on Vendor: Commercial item l

Licensee Representative:

i Signature

,AY #

Date / 13

~y-v 4

4 1

I 1

q 32 f

i

4 ATTACliMENT (1)

FASTENERTESTING DATA SHEET SampleIDNo CCNPP-Q(N) hiech No 73-401 i

r SRI Tag Noa 473520-E (typical) i Fastener

Description:

Nut, Hex, 1-1/4' x 7 TPI, Plated Finish, lleavy Series Purchase Order No. 93724 GX Date: 01-28-87 Description of Sample Stock Location: Warehouse w2, 24F081D l

hiaterial Specification as Documented by Licensee Records: A 194 Gr 2}l liead htarking:

0\\

4, Class / Procurement Lovel: Commercial Quality (Safety Related)

General Plant Application: General Plant Use Vendor: AAA Bolt and Screw, 8800 Kelso Drive, Baltimore, hid 21221

)

QA Requirements Imposed on Vendor: Commercial item Licensee Representative; j

i Signature

)

/,

,Y V

Date 1

ATTACilMENT (1)

FASTENER TESTING DATA SHEET Sample ID No. CCNPP-R(F)

Mech No.: 80-178 l

SRI Tag No.: N/A 1

Fastener

Description:

Bolt, Heavy Hex IIead,1-1/2" x 6 TPI x 8", Heat Treated, Semi-Fini:hed Purchase Order No. 97876 GX Date: 04-21-87 Description of Sample Stock Location: Warehouse #3, 34UO73A i

l Material Specification as Documented by Licensee Records: A 325, Type 3, Weathering Steel Head Marking:

C R

ASM S

Class / Procurement Level: Non Safety Related 1

General Plant Application: Sea Wall Baffles i

Vendor: A&A Bolt and Screw, 8800 Kelso Drive, Baltimore, MD 21221 QA Requirements Imposed on Vendor: Commercial Item Licensee Representative:

Date./, 2, _,

Signature

.. l

ATTACHMENT (1)

FASTENER TESTING DATA SHEET Sample ID No.CCNPP-R(N)

Mech No.: 80-177 SRI Tag No.: N/A Fastener

Description:

Nut, Heavy Hex,1-1/2" x 6 TPI, Single Chamfer with Washer Face Purchase Order No. N/A Date: N/A Description of Sample Stock Location: Warehouse #3, 34UO73A Material Specification as Documented by Licensee Records: A 325, Type 3 Head Marking:

3 4

Class / Procurement Level: Non-Safety Related General Plant Application: Sea Wall Baffles Vendor: N/A QA Requirements Imposed on Vendor: Commercial item Licensee Representative:

Signature

/4 W Date

/ N I.

, i

]

ATTACilMENT (1)

FASTENERTE5flNG DATA SIIEET :

1 Sample ID No. CCNPP-S(F)

Mech No.: 59-980 SRI Tag No.: 289077-E Fastener

Description:

Bolt, 1"

x 4-3/4" Purchase Order No. 24426 GX Date: 07-28-82 Description of Sample Stock Location: Warehouse #2, 22J025E Material Specification as Documented by Licensee Records: A 490 Head Marking:

i mo Class / Procurement Level: Commercial Quality (Safety Related)

General Plant Application: Unit 2 Neutron Shield Platform 5

Vendor: C. S. Metals Service, Inc.

QA Requirements Imposed on Vendor. Commercial Item Licensee Representative:

OA Date 7

.MN-Si nature

,/

8

ATTACHMENT (1)

FASTENERTESTING DATA SHEET I

Sample ID No. CCNPP-S(N)

Mech No.: 59-980 SRI Tag No.: 289077-E Fastener

Description:

Nut, Heavy Hex, l'

Purchase Order No. 24426 GX

' Date: 07-28-82 Description of Sample Stock Location: Warehouse #2, 22J025E Material Specification as Documented by Licensee Records: A 194 Gr 2H Head Marking:

H 2.

Class / Procurement Level: Commercial Quality (Safety Related)

General Plant Application: Unit 2 Neutron Shield Platform Vendor: C. S.

Metals Service, Inc.

QA Requirements Imposed on Vendor: Commercial Item Licensee Representative:

I

/, 1 Signature Date 1

7 r

) \\

ATTACHMENT (1)

FASTENERTESTING DATA SilEET i

Sample ID No.CCNPP-T(F)

Mech No.: 78-A31 SRI Tag No.: 470622-E (typical)

Fastener

Description:

Capscrew, llex flead,1-1/4" x 7; TPI x 4"' long, Plated Finisn Purchase Order No. 01750 GX Date: 06-25-87 i

Description of Sample Stock Location: Warehouse #2, 21D040C l

Material Specification as Documented by Licensee Records: A 307 Gr B j

1 liend Marking:

tD l

/

Class / Procurement Level: Commercial Quality (Safety Related)

General Plant Application: General Plant Use Vendor: A&A Bolt and Screw, 8800 Kelso Drive, Baltimore, MD 21221 QA Requirements Imposed on Vendor: Commercial item i

1 Licensee Representative:

Signature --.

d alhhN Date

/

v{

l I

ATTACHMENT (I) ~

FASTENERTESTING DATA SIIEET l

Sample ID No. CCNPP-T(N) hiech No.: 78-401 SRI Tag No.: 473520-E (typical)

Fastener

Description:

Nut, Hex, 1-1/4" x 7 TPI, Plated Finish, Heavy Series Purchase Order No. 93724 GX Date: 01-28-87 Description of Sample Stock Location: Wr.rehouse #2, 24F081D hiaterial Specification as Documented by Licensee Recordt A 194 Gr 211 liead hfarking:

U 2.H Class / Procurement Level: Commercial Quality (Safety Related)

General Plant Application: General Plant Use Vendor: A&A Bolt and Screw, 8800 Kelso Drive, Baltiraore, hiD 21221 QA Requirements imposed on Vendor: Commercial Item Licensee Representative:

Signature A 'C

Date

/-

v-7 i

1 l _

ATTACIIMENT (2)

DATA

SUMMARY

l TABLE NO.1:

Specification Requirements for all Fasteners Tested TABLE NO. 2:

Chemical Analysis Data for Safety Related Fasteners (Fastener items

~

A to J)

TABLE NO. 3:

Mechanical Property Data for Safety Related Fasteners TABLE NO.4:

Chemistry and liardness Data for Non-Safety Related Parts (Items K to T)

TABLE NO. 5:

Specification Deviations 1

TABLE NO. 1:

SPECIFICATION REQUIREMENTS EUR FASTENERS TESTED Elemental Weight Pe' cent C

Mn P

S Si Cr Mo Ni Cu UTS/YS Hard-Parts Spec.

(Max)

(Max)

(KSi)

Elona.

ness A193 0.35- 0.61-0.045 0.045 0.13- 0.70-0.13-125 16 24 A,B,C,D,E, Grade B7 0.51 1.14 0.37 1.25 0.27 105 HRC F,G,H,K,L, l

Min M,N,0(F)

(1)

A194 0.35- 0.61 0.045 0.045 0.13 0.70 0.13 24-38 A,B,F,G,H(N)

Grade 7 0.51 1.14 0.37 1.25 0.27 HRC A194 0.37 0.048 0.058 24-38 C,D,E,K,L, Grade 2H min HRC O.P.0,S.T(N)

A193 0.14 1.21 0.07 0.140 1.05 11.85 110 15 I(F)

(2)

Grade B6 max max min max 14.15 85 A194 0.14 1.21 0.07 0.140 1.05 11.85 24-39 I(N)

(2)

Grade B6 max max

min, max 14.15 HRC AS40 0.35- 0.56-0.03 0.03 0.13- 0.60-0.18-1.5 135 13 25-34 J(F)

Grade B23 0.46 0.99 0.37 1.0 0.32 2.05 120 HRC Class IV I

A563 0.58 0.13 32 M,N(N)

Grade A max HRC max A325 0.27 0.47 0.048 0.058 24-35 Q(F)

Type 1 min min HRC SAE J429 0.28-0.048 0.058 25-34 P(F)

Grade 5 0.55 HRC A563 0.07 0.055 0.15 0.25 1.03 0.22 78HRB R(N)

Grade C3 0.155 0.75 1.3 max 0.58 38HRC Class N A325 0.31 0.86 0.045 0.055 0.13 0.42 0.22 0.22 19-31 R(F)

Type 3 0.42 1.24 0.37 0.68 0.48 0.48 HRC Class A A490 0.28 0.045 0.045 33-38 S(F)

Type 1 0.50 HRC A307 0.04 0.05 69-95 T(F)

Grade B HRB Note:(1) Specification has an ultimate tensile strength requirement of 125 Ksi but no hardness require-ments.

BG&E assigned the above requirements based on Hardness /UTS correlations for hardenable alloy steels in the 8th edition Metals Handbook Volume No. 1 and hardness requirements for A194 Grade 7 nuts which have the same Chemistry and heat treatment requirements.

(2) 1969 ASTM Specification; All other specifications are from 1983 ASME Section II or ASTM.

TABLE NO. 2:

CHEMICAL ANALYSIS DATA FOR SAFETY RELATED PARTS Elemental Weight Percent Part ID C

Mn P

S Si Cr Mo Ni A (H) 0.425 0.807 0.012 0.024 0.195 0.985 0.16 NA A (F) 0.408 0.845 0.025 0.030 0.185 0.946 0.21 NA B (N) 0.385 0.901 0.012 0.020 0.225 1.039 0.16 NA B (F) 0.377 0.799 0.026 0.020 0.231 0.973 0.18 NA C (N) 0.407 NA 0.014 0.021 NA NA NA NA C (F) 0.388 0.775 0,025 0.018 0.183 1.007 0.20 NA D (N) 0.443 NA 0.026 0.014 NA NA NA NA D (F) 0.389 0.781 0.025 0.024 0.215 1.023 0.21 NA E (N) 0.430 NA 0.022 0.019 NA NA NA NA E (F) 0.404 0.819 0.015 0.012 0.193 1.034 0.21 NA F (N) 0.381 0.868 0.009 0.018 0.186 0.937 0.17 NA F (F) 0.352 0.726 0.011 0.024 0.199 0.941 0.16 NA G (N) 0.386 1.077 0.011 0.028 0.201 1.054 0.17 NA G (F) 0.356 0.870 0.017 0.013 0.195 1.073 0.19 NA H (N) 0.387 0.935 0.011 0.010 0.193 0.979 0.19 NA H (F) 0.360 0.864 0.018 0.014 0.209 1.059 0.20 NA I (N) 0.092 0.481 0.012 0.245 0.509 12.265 NA NA I (F) 0.092 0.506 0.025 0.298 0.332 13.810 NA NA J (F) 0.394 0.700 0.012 0.014 0.224 0.727 0.21 1.963 l

TMEE 10. 3: DEK31ANIOL HMERLY DPGA RR SAFEIY REIRED HUUS Hardness Impact Strength Iateral g ion Part ID (HRC)

UPS (Ksi) 0.2% YS (Ksi)

% Elorn.

@ 65 P (ft/lbs) 0 65 F (10 in.)

A (N) 31.0 NA NA NA NA NA A (F) 30.3 138.4 123.7 21.0 92 54 B (N) 26.3 NA NA NA NA NA B (F) 28.5 131.6 112.2 21.0 48 36 C (N) 25.9 NA NA NA NA NA C (F) 25.9 136.7 122.4 21.0 NA NA D (N) 26.8 NA NA NA NA NA D (F) 27.0 135.8 119.2 22.0 NA NA E (N) 27.1 NA NA~

NA NA NA E (F) 26.9 138.5 122.4 19.5 NA NA F (N) 26.6 NA NA NA NA NA F (F) 26.9 135.1 118.0 19.5 60 38 G (N) 27.2 NA NA NA NA NA G (F) 26.2 141.8 127.0 20.0 54 36 H (N) 26.4 NA NA NA NA NA H (F) 28.2 140.0 122.5 21.0 63 45 I (N) 93.5 HRB NA NA NA NA NA I (F) 77.9 HRB 86.0 53.8 26.5 NA NA J (F) 33.4 147.2 134.7 19.5 63 37

TABLE NO. 4: QEMISIRY AND IRIDESS DMA PtR )KN-SAHmf REIRIED PARIS Elemental Weight Percent Part ID C

Mn P

S Si Cr Mo Ni/Ou h s HRC K (N) 0.429 la 0.016 0.016 NA NA la NA 27.6 K (F) 0.407 0.898 0,020 0.015 0.243 1.013 0.21 la 25.5 L (N) 0.427 NA 0.020 0.013 NA NA NA NA 27.4 L (F) 0.356 0.814 0.018 0.009 0.155 0.867 0.15 NA 30.1 M (N) 0.151 la 0.015 0.009 la la NA

}&

76.0 HRB M (F) 0.390 0.772 0.008 0.019 0.133 0.759 0.11 IDL 25.9 N (N) 0.110 NA 0.017 0.011 NA NA la la 92.7 HPS N (F) 0.372 0.705 0.016 0.012 0.199 1.042 0.14 NA 25.5 0 (N) 0.424 NA 0.020 0.013 la NA NA la 27.2 O (F) 0.396 0.935 0.009 0.016 0.155 1.030 0.17 la 24.8 P (N) 0.422 la 0.013 0.011 NA NA la NA 25.8 P (F) 0.316 0.827 0.012 0.009 0.184 NA NA NA 25.0 Q (N) 0.425 NA 0.022 0.021 NA la la NA 28.3 Q (F) 0.404 0,768 0.005 0.025 NA la NA NA 25.5 R (N) 0.113 0.742 0.063 0.012 0.225 0.840 la 0.449/

26.3 0.344 R (F) 0.310 1.021 0.013 0.022 0.183 0.473 la 0.319/

27.8 0.383 S (N) 0.467 NA 0.011 0.015 la la NA la 28.9 S (F) 0.408 0.803 0.011 0.013 NA 0.911 0.18 la 30.3 T (N) 0.422 NA 0.022 0.022 la la la la 29.1 T (F) la la 0.018 0.041 NA la la la 73.6 HRB

TABEE ND. 5: sm mCATICH IEVIATICNS Specification Part Specification Requirements Reported Deviation Ocnnents I(F)

A 193 Grade B6 110 Ksi UTS 86.0 Ksi

-24.0 Ksi See Note (a) 85 Fsi 0.2% YS 53.8 Fsi

-31.2 Ksi I(N)

A 194 Grade 6 24-38 HRC 93.5 HRB Off Scale See Note (a)

S(F)

A 430 Type 1 33-38 HRC 30.3 HRC

-2.7 HRC See Note (b)

M(F)

A 193 Grade B7 0.13-0.27% Mo 0.11% Mo

-0.02% Mo See Note (c) 1 R(N)

A 563 Grade C3 0.07-0.155% P 0.063% P

-0.007% P See Note (c)

)

l i

Notes:

(a)

'Ihe as found strergth of the nut and stud is adequate to meet all design dead-weight, pressure, seismic and gasket seating loads.

(b)

'Ihis hardness deviation is considered minor ard will result in less than a 10% reduction of the tensile strength frun the specification requirements.

In fact the tersile strength may have been within the specification i

requirements but there was not enough sample remaining to test.

Based on our experience fasteners with tensile properties within 10% of the specification i

are adequate to ensure structural integrity.

(c)

'Ihis chemistry deviation is minor ard does not adversely affect any of the applicable material properties. 'Ihe hardness test indicates the strength is within the specification requirements.

ATTACllMENT m RECEIITINSPECTION ANDINTERNALCONTROLS Characteristics Currentiv Examined Durina Receiot Insocction of Fasteners:

1.)

Marking requirements for grade, manufacturer's identification, and heat code, as applicable.

2.)

Review of material test report and certificate of conformance for compliance with the purchase order and material specification.

3.)

Visual and dimensional examination, as required.

i 1

Internal Controls:

Fasteners are stored in the Calvert Cliffs warehouse, outside the plant protected area, and are issued from stock on an as-requested basis in support of maintenance activities. I asteners are stored by quality level, type, size, material grade, and installation location.

A material stock description is maintained on a computer database for each item in stock. The warehouse is a controlled-access area and is subject to quality assurance audits.

Fasteners are withdrawn from the warehouse via a store order form which must specify the particular equipment or system the fasteners will be used in. The completed store order forms are subject to quality assurance audits.

The need to withdraw fasteners from stock is identified during the planning process for each maintenance order. A maintenance planner reviews each request for maintenance and initiates a maintenance order providing instructions for completing the work. The maintenance order also specifies any replacement fasteners by quality level, grade and stock number, as appropriate. These fasteners are ordered from the warehouse and are transferred to a controlled-access staging area inside the plant. A limited quantity of commonly used fasteners are maintained in this staging area. Prior to working a maintenance order, mechanics pick up the necessary materials, including fasteners, from j

the staging area. The mechanics are instructed to check the sMck number of the i

material received against the stock number specified on the maintenance order and to visually check for material grade markings. Safety-related maintenance work is subject to observation and inspection by quality control personnel, i

1 i

l l