s-g Ct: tion support Dep!rtnient 4

10 CFR 50.90 V

PECO NUCLEAR Peco Energy company A Unit of PECO Energy

$7N9f w

June 30,1997 Docket Nos. 50-352 50-353 License Nos. NPF-39 4

NPF-85 l

U.S. Nuclear Regulatory Commission Attn: Document Control Desk

' Washington, DC 20555

Subject:

Limerick Generating Station, Units 1 and 2 Technical Specifications Change Request No. 9649-0 Response to Request for Additional information

.)

Gentlemen:

1 By letter dated August 8,1996, PECO Energy Company submitted Technical Specifications (TS)

Change Request No.96-094, in accordance with 10 CFR 50.90, requesting an amendment to the TS (Appendix A) of Operating License Nos. NPF-39 and NPF-85 for Limerick Generating Station (LGS), Units 1 and 2, respectively. This proposed TS change involves proposed changes to TS Sections 3/4.3.1, " Reactor Protection System Instrumentation," 3/4.3.2, " Isolation Actuation Instrumentation," 3/4.3.3, " Emergency Core Cooling System Actuation Instrumentation," and the associated TS Bases Sections 3/4.3.1 and 3/4.3.2 to eliminate selected response time testing requirements. The proposed TS chances are supported by analyses performed by the Boiling Water Reactor Owners' Group (BWROG) and documented in NEDO-32291, " System Analyses for the Elimination of Selected Response Time Testing Requirements," dated January 1994.

j l

Subsequently, during a January 9,1997, telephone conversation between representatives of the NRC and PECO Energy, the NRC requested that adoltional information be provided in order f ar the NRC to continue its review of TS Change Request No. 96-09-0 Specifically, the NRC identified four (4) issues that pertained to aspects of the plant instrumentation associated with this proposed TS change.

Accordingly, the attachment and exhibits to this letter provide the requested information. Each of the four (4) issues are identified in the attachment followed by our response to each identified issue. The exhibits contain the requested information regarding the specific plant

/

instrumentation affected by this proposed TS change. This information is being submitted under affirmation, arvi the associated affidavit is enclosed.

/

9707170077 970630

aa ^===P llisisis!Mi@!i

3 e'

s O, n

June ? -),1997 Page 2 If you have any questions or require additional information, please do not hesitate to contact us.

Very truly yours, i

i G. A. Hunger, Jr.

Director - Licensing Attachment / Exhibits Enclosure cc:

H. J. Miller, Administrator, P egion I, USNRC (w/ attachment / exhibits, enclosure)

N. S. Perry, USNRC Senior Resident inspector, LGS (w/ attachment / exhibits, enclosure)

R. R. Janati, Director, PA Bureau of Radiological Protection (w/ attachment / exhibits, enclosure)

)

e

1 e'

I, a

COMMONWEALTH OF PENNSYLVANIA l

ss.

COUNTY OF CHESTER J. B. Cotton, being first duly sworn, deposes and says:

That he is Vice President of PECO Energy Company, the Applicant herein; that he has read the foregoing response providing additional lnformation for Technical Specifications Change Request No. 96-09-0 for Limerick Generating Station, Units 1 and 2, Facility Operating License Nos. NPF-39 and NPF-85, conceming the elimination of response time testing for certain instrumentation, and knows the conterts thereof; and that the statements and matters set forth therein are true and correct to the best of his knowledge, information, and belief.

M

/

/

Vice President Subscribed and swom to before me this 3Obay of 14 -

1997.

+tg Notary P ic Notarw: seed Lau 8kro&.

Twp., Chester 4

Eces May 17, 990

, MPennsylvuNaWof Nots j

l

, e, i

ATTACHMENT LIMERICK GENERATING STATION UNITS 1 AND 2 Docket Nos.

50-352 50-353 License Nos.

NPF-39 NPF-85 RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION FOR TECHNICAL SPECIFICATIONS CHANGE REQUEST NO. 96-09-0

Attachment Page 1 of 2 By letter dated August 8,1996, PECO Energy Company submitted Technical Specifications (TS) Change Request No. 96-09-0, in accordance with 10 CFR 50.90, requesting an amendment to the TS (Appendix A) of Operating License Nos. NPF-39 and NPF-85 for Umerick Generating Station (LGS), Units 1 and 2, respectively. This proposed TS change involves proposed changes to TS Sections 3/4.3.1, " Reactor Protection System Instrumentation," 3/4.3.2, " Isolation Actuation Instrumentation," 3/4.3.3, " Emergency Core Cooling System Actuation Instrumentation," and the associated TS Bases Sections 3/4.3.1 and 3/4.3.2 to eliminate selected response time testing requirements. Ti.e proposed TS changes are supported by analyses performed by the Boiling Water Reactor Owners' Group (BWROG) and documented in NEDO-32291, " System Analyses for the Elimination of Selected Response Time Testing Requirements," dated January 1994. Subsequently, during a January 9,1997, telephone conversation between representatives of the NRC and PECO Energy, the NRC requested that additional Information be provided in order for the NRC to continue its review of TS Change Request No. 96-09-0. Specifically, the NRC identified four (4) issees which are identified below followed by our response for each issue.

Issue 1 Provide a list showing wNnh instruments co respond to which manufacturers. Also, identify any associated Rosemount instrumentation that may be affected.

Resoonsg The exhibits (i.e., Exhibits 1 and 2) to this letter provide the requested information. The component identification, component type, manufacturer, model, and safety function are provided for each specific instrument affected by this proposed TS change.

Issue 2 On page 5 of 13 of the referenced letter (i.e., August 8,1996 letter), the "Affected Equipment

  • and the

" Safety Function" for item 3 both state " Reactor Water Level Low - Level 1, 2." is this correct for the

' Safety Function," or does it need to be clarified?

Response

The description provided in our August 8,1996, letter for the " Safety Function

  • and "Affected Equipment" is correct and accurate. A specific list of affected equipment for item 3 is provided in the paragraph discussing this specific section. Therefore, we do not believe that it is necessary to provide additional clarlfication concerning the affected equipment description since it is discussed in the text of the paragraph.

Issue 3 Items 9,10, and 11 on pages 7 and 8 cf the referenced letter (i.e., August 8,1996) Involve " Delta-Flow" and " Delta-Pressure," yet the referenced NEDO document uses the terminology "High" rather than " Delta" when referring to flow and pressure. An equivalency statement is necessary.

Resoonse We do mt believe that it is necessary to provide a specific equivalency statement regarding Delta-Flow for the Reactor Water Cleanup (RWCU) and Delta-Pressure for the High Pressure Coolant injection (HPCl) system and Reactor Core isolation Cooling (RCIC) system. It is strictly semantics on how the LGS Technical Specifications (TS) are written versus those at other plants. With respect to the RWCU system, LGS measures the difference between inlet and outlet flows to determine high flow. LGS measures change in pressure through flow orifices for the HPCI and RCIC systems to determine high flow. Therefore, under these specific circumstances we consider the description for " Delta" and "High" to be equivalent.

j

. - ~. -

Attachment Page 2 of 2 L

lasue 4

(

ltem 12 on page 9 of the referenced letter (i.e., Augut,t 8,1996) Involves 'High Pressure," yet the referenced NEDO document only addresses High Flow and High Temperature (NEDO page J12).

Response

l In Section 8 of the referenced NEDO document, on page 84, under item (3), the following statement is made.

RTTs of allInstrumentation loops for the following trip functions in the Isolation Actuation instrumentation and ECCS Instrumentation can be eliminated based on other Technical

. Specification surveillance of the Instrumentation loops and/or other techniques as required:

- All ECCS actuation Instrumentation loops

- Allisolation System Actuation Instrumentation loops except for MSIV sensors Based on the above statement, we consider proposed elimination of the Primary Containment High Pressure isolation to be within the scope of the NEDO, and therefore, acceptable for removal from the TS, l

l l

l

y 2

4 m.

+

4e

<- +

ann--

an -

4-no..--waa EXHIBIT 1 U

LISTING OF PLANT EQUIPMENT ASSOCIATED WITH TECHNICAL SPECIFICATIONS CHANGE REQUEST NO. 96-09-0 (ITEMS 1-8 OF AUGUST 8,1996 SUBMITTAL) i

d Equipment Associated With Items 1-8 in August 8,1996 Submittal COMPONENTID COMPONENTTYPE M4NUFACT. MODEL SAFETYFUNCTION LT-042-1NOROA TRANSMITTER ROSEMOUNT 1153084 RPS & NSSSS REACTOR WATER LEVEL-LOW LEVEL 3 LT&2-1N080B TRANSMITTER ROSEMOUNT 1153DB4 RPS & NSSSS REACTOR WATER LEVEL-LOW LEVEL 3 LT-042-1 N080C TRANSMITTER ROSEMOUNT 1153DB4 RPS & NSSSS REACTOR WATER LEVEL-LOW LEVEL 3 LT-042-1 N080D TRANSMITTER ROSEMOUNT 1153084 RPS & NSSSS REACTOR WATER LEVEL-LOW LEVEL 3 LT-042-1N091 A TRANSMITTER ROSEMOUNT 11530B5 ECCS & NSSSS RX WATER-LEVEL 12,8 LT-042-1N091 B TRANSMITTER ROSEMOUNT 1153DB5 ECCS & NSSSS RX WATER-LEVEL 12,8 LT-042-1 NO91C TRANSMITTER ROSEMOUNT 1153DB5 ECCS & NSSSS RX WATER-LEVEL 12,8 LT-042-1N091 D TRANSMITTER ROSEMOUNT 11530B5 ECCS & NSSSS RX WATER-LEVEL 12,8

+

LT 042-1N091E TRANSMITTER ROSEMOUNT 1153DB5 ECCS & NSSSS RX WATER-LEVEL 1,2,8 LT-042-1 N091 F TRANSMITTER ROSEMOUNT 11530B5 ECCS & NSSSS RX WATER-LEVEL 12,8 LT-042-1N091G TRANSMITTER ROSEMOUNT 1153DB5 ECCS & NSSES RX WATER-LEVEL 12,8 LT-042-1NO91 H TRANSMITTER ROSEMOUNT 1153DB5 ECCS & NSSSS RX WATER-LEVEL 1,2,8 LT-042-2N080A TRANSMITTER ROSEMOUNT 1153DB4 RPS & NSSSS REACTOR WATER LEVEL-LOW LEVEL 3 LT-042-2N080B TRANSMITTER ROSEMOUNT 1153DB4 RPS & NSSSS REACTOR WATER LEVEL-LOW LEVEL 3 LT-042-2NO80C TRANSMITTER ROSEMOUNT 1153DB4 RPS & NSSSS REACTOR WATER LEVEL-LOW LEVEL 3 LT-042-2N0800 TRANSMITTER ROSEMOUNT 1153DB4 RPS & NSSSS REACTOR WATER LEVEL-LOW LEVEL 3 LT-042-2N091 A TRANSMITTER ROSEMOUNT 1153085 ECCS & NSSSS RX WATER-LEVEL 1,2,8 LT-042-2NO91 B TRANSMITTER ROSEMOUNT 1153DB5 ECCS & NSSSS RX WATER-LEVEL 1,2,8 s

I

Equipment Associated With Items 1-8 in August 8,1996 Submittal COMPONENTID COMPONENTTYPE MANUFACT. MODEL SAFETYFUNCTION LT-042-2N091C TRANSMITTER ROSEMOUNT 1153DB5 ECCS & NSSSS RX WATER-LEVEL 1,2,8 LT-042-2NO91D TRANSMITTER RC,SEMOUNT 1153085 ECCS & NSSSS RX WATER-LEVEL 1,2,8 LT-042-2N091E TRANSMITTER ROSEMOUNT 1153DBS ECCS & NSSSS RX WATER-LEVEL 1,2,8 LT-042-2N091F TRANSMITTER ROSEMOUNT 1153DB5 ECCS & NSSSS RX WATER-LEVEL 1,2,8 LT-042-2N091G TRANSMITTER 8tOSEMOUNT 1153085 ECCS & NSSSS RX WATER-LEVEL 1,2,8 LT-042-2N091H TRANSMITTER ROSEMOUNT 1153085 ECCS & NSSSS RX WATER-LEVEL 1,2,8 PDT-041-1N006A TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-1N0068 TRANSMITTER ROSEMOUNT 1153D87 NSSSS MSL FLOW-HiGH PDT-041-1N066C TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-1N006D TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-1N087A TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-1N087B TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-1N087C TRANSMITTFR ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-1 NOB 7D TRANSMITTER ROSEMOUNT 1153D87 NSSSS MSL FLOW-HIGH PDT-041-1 N088A TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-1N0888 TRANSMITTER ROSEMOUNT 1153087 NSSSS MSL FLOW-HIGH PDT-041-1N088C TRANSMITTER ROSEMOUNT 11530B7 NSSSS MSL FLOW-HIGH PDT-041-1N088D TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-1N089A TRANSMITTER 8tOSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH 2

h a,

e Equipment Associated With Items 1-8 in August 8,1996 Submittal COMPONENTJD COMPONENT T1PE MANUFACT.

MODEL SAFETYFUNCTION PDT441-1N089B TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-1N089C TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT441-1N089D TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-2N006A TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-2N0868 TRANSMITTER ROSEMOUNT 1153DB7 NSS?S MSL FLOW-HIGH s

PDT-041-2N006C TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLON-HIGH NSSSS MSL FLOW-HIGH PDT-041-2N006D TRANSMITTER ROSEMOUNT 1153DB7 a

PDT-041-2N087A TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-2N087B TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL rLOW-HiGH PDT-041-2N087C TRANSMITTER ROSEMOUNT 1153087 NSSSS MSL FLOW-HIGH PDT-041-2N087D TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-2N088A TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-2N0888 TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-2N088C TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-2NOBBD TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HtGH PDT-041-2N089A TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-2N089B TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-2N089C TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH PDT-041-2N089D TRANSMITTER ROSEMOUNT 1153DB7 NSSSS MSL FLOW-HIGH 3

Equipment Associated With Items 1-8 in August 8,1996 Submittal COMPONENTID COMPONENT TYPE MANUFACT.

MODEL SAFETYFUNCTION PT-042-1N090A TRANSMITTER ROSEMOUNT 1153GB9 ECCS RX PRESSURE-LO'W PT-042-1N0908 TRANSMITTER ROSEMOUNT 1153GB9 ECCS RX PRESSURE-LOW PT-042-1N090C TRANSMITTER ROSEMOUNT 1153GB9 ECCS RX PRESSURE-LOW s

PT-042-1N0900 TRANSMITTER ROSEMOUNT 1153GB9 ECCS RX PRESSURE-LOW PT-042-1N090E TRANSMITTER ROSEMOUNT 1153GB9 ECCS RX PRESSURE-LOW PT-042-1N090F TRANSMITTER ROSEMOUNT 1153GB9 ECCS RX PRESSURE-LOW PT-042-1N090G TRANSMITTER ROSEMOUNT 1153GB9 ECCS RX PRESSURE-LOW PT-042-1N090H TRANSMITTER ROSEMOUNT 1153GB9 ECCS RX PRESSURE-LOW PT-042-2N090A TRANSMITTER ROSEMOUNT 1151GP9 ECCS RX PRESSURE-LOW PT-042-2N0908 TRANSMITTER ROSEMOUNT 1151GP9 ECCS RX PRESSURE-LOW PT-042-2N090C TRANSMITTER ROSEMOUNT 1153GB9 ECCS RX PRESSURE-LOW PT-042-2N090D TRANSMITTER ROSEMOUNT 1153GB9 ECCS RX PRESSURE-LOW PT-042-2N090E TRANSMITTER ROSEMOUNT 1151GP9 ECCS RX PRESSURE-LOW PT-042-2N090F TRANSMITTER ROSEMOUNT 1151GP9 ECCS RX PRESSURE-LOW PT-042-2N090G TRANSMITTER ROSEMOUNT 1151GP9 ECCS RX PRESSURE-LOW PT-042-2N090H TRANSMITTER ROSEMOUNT 1151GP9 ECCS RX PRESSURE-LOW 4

=

1 a

q 4

i h

i i

)

1 1

4 a

4 i

EXHIBIT 2 1

I LISTING OF PLANT EQUIPMENT ASSOCIATED WITH TECHNICAL SPECIFICATIONS CHANGE REQUEST NO. 96 09-0 l

(ITEMS 9-13 OF AUGUST 8,1996 SUBMITTAL) j i

I 4

t i

1 1

1 l

i I'

4 4

4 e

i i

d E

1 4

4 J

E i

i

I

~

NSSSS RWCU DIFFERENTIAL FLOW-HIGH (Safety Function)

TABLE I (Equipment Associated With Item 9 in August 8,19% Submittal)

Page I cf 2 COMPONENT ID COMPONENT TYPE MANUFACTURER MODEL NUMBER B212-K6A RELAY AMERACE GPI B21B-K6A RELAY AMERACE GPI B21B-K6D RELAY AMERACE GPI B21B-K6D RELAY AMERACE GPI FDS-044-IN603A SWITCH BAILEY 745 FDS-044-IN603A SWITCH BAILEY 745 FDS444-IN603D SWITCH BAILEY 745 FDS444-IN603D SWITCH BAILEY 745 FDS-044-2N603A SWITCH BAILEY 745 FDS-044-2N603A SWITCH BAILEY 745 FDS-044-2N603D SWITCH BAILEY 745 FDS-044-2N603D SWITCH BAILEY 745 FT-044-1N012A TRANSMITTER ROSEMOUNT I153DB5 FT-044-1N012D TRANSMITFER ROSEMOUNT I153DB5 FT-044-IN041 A TRANSMITTER ROSEMOUNT ll53DB5 FT-044-1N041D TRANSMITTER ROSEMOUNT I153DB5

NSSSS RWCU DIFFERENTIAL FLOW-HIGH (Safety Function)

TABLE 1 (Equipment Associated With Item 9 in August 8,1996 Submittal)

Page 2 of 2 COMPONENTID COMPONENT TYPE MANUFACTURER MODEL NUMBER FT-044-2NO12A TRANSMITTER ROSEMOUNT 1153DB5 FT-044-2N012D TRANSMTITER ROSEMOUNT ll53DB5 FT-044-2N041 A TRANSMFITER ROSEMOUNT ll53DB5 FT-044-2N041D TRANSMTITER ROSEMOUNT I153DB5 FY-044-tK604A CONVERTER BAILEY 752 FY-044-lK604D CONVERTER BAILEY 752 FY-044-1K605A SQUARE ROOTER BAILEY 750 FY-044-1K605D SQUARE ROOTER BAILEY 750 FY-044-2K604A CONVERTER BAILEY 752 FY-044-2K604D CONVERTER BAILEY 752 FY-044-2K605A SQUARE ROOTER BAILEY 750 FY-044-2K605D SQUARE ROOTER BAILEY 750 G31-R616A P.ELAY GE CR2940 G31-R616A RELAY GE CR2940 G31-R616D RELAY GE CR2940 G31-R616D RELAY-GE CR2940

NSSSS HPCI STEAM LINE DP-HIGII (Safety Function)

TABLE 2 (Equipment Associated With Item 10 of August 8,1996 Submittal)

Page i:l!

COMPONENT ID COMPONENT TYPE MANUFACTURER MODEL NUMBER E41A-K158 RELAY AMERACE ETR E41A-K15B RELAY AMERACE ETR E41A-K15D RELAY AMERACE ETR

.E41A-K15D RELAY AMERACE ETR PDIS-055-IN657B SWITCH ROSEMOUNT 510DU PDIS-055-IN657D SWITCH ROSEMOUNT 510DU PDIS-055-2N657B SWITCH ROSEMOUNT 510DU PDIS-055-2N657D SWITCH ROSEMOUNT 510DU PDS-055-IN660B SWITCH ROSEMOUNT 510DU PDS-055-IN660D SWITCH ROSEMOUNT 510DU PDS-055-2N660B SWITCH ROSEMOUNT 710DU PDS-055-2N660D SWITCH ROSEMOUNT 710DU PDT-055-1N057B TRANSMITTER ROSEMOUNT 1153DB6 PDT-055-IN057D TRANSMITTER ROSEMOUNT ll53DB6 PDT-055-2N057B TRANSMITTER ROSEMOUNT ll53DB6 PDT-055-2N057D TRANSMITTER ROSEMOUhT ll53DB6

NSSSS HPCI STEAM SUPPLY PRESSURE-LOW (Safety Function)

TABLE 3 (Equipment Associated With Item 10 in August 8,1996 Submittal)

Page 1 of 2 COMPONENTID COMPONENTTYPE MANUFACTURER MODEL NUMBER E41A-K16B RELAY AhERACE EGP E41A-K16B RELAY AMERACE EGP E41A-K16D RELAY AMERACE EGP E41A-K16D RELAY AMERACE EGP E41A-K178 RELAY AMERACE EGP E41A-K17B RELAY AMERACE EGP E41A-K17D RELAY AMERACE EGP E41A-K17D RELAY AMERACE EGP PIS-055-IN658B SWITCH ROSEMOUNT 510DU PIS-055-IN658D SWITCH ROSEMOUNT 710DU PIS-055-IN658F SWITCH ROSEMOUNT 510DU PIS 055-IN658H SWITCH ROSEMOUNT 510DU PIS-055-2N658B SWITCH ROSEMOUNT 510DU PIS-055-2N658D SWITCH ROSEMOUNT 510DU PIS-055-2N658F SWITCH ROSEMOUNT 510DU PIS-055-2N658H SWITCH ROSEMOUNT 510DU

~

NSSSS HPCI STEAM SUPPLY PRESSURE-LOW (Safety Function)

TABLE 3 (Equipment Associated With Item 10 in August 8,1996 Submittal)

Page 2 of 2 COMPONENT ID COMPONENT TYPE MANUFACTURER MODEL NUMBER FT-055-1N058B TRANSMITTER ROSEMOUNT I153GB7 PT-055-IN058D TRANSMTITER ROSEMOUNT ll53GB7 FT-055-IN058F TRANSMTITER ROSEMOUNT ll53GB7 FT-055-1N058H TRANSMITTER ROSEMOUNT 1153GB7 FT-055-2N058B TRANSMITTER ROSEMOUNT ll51GP7 PT-055-2N058D TRANSMITTER ROSEMOUNT 115IGP7 FT-055-2N058F TRANSMrlTER ROSEMOUKr ll51GP7 FT-055-2N058H TRANSMITTER ROSEMOUNT 1151GP7 f

NSSSS RCIC STEAM LINE DP-HIGH (Safety Function)

TABLE 4 (Equipment Associated With Item 11 in August 8,19% Submittal)

PageiofI COMPONENT ID COMPONENT TYPE MANUFACTURER MODEL NUMBER E51A-K15A RELAY AMERACE ETR E51A-K15A RELAY AMERACE ETR E51A-K15C RELAY AMERACE ETR E51A-K15C RELAY AMERACE ETR PDIS-049-IN657A SWITCH ROSEMOUNT 510DU PDIS-049-IN657C SWITCH ROSEMOUNT 510DU PDIS-049-2N657A SWITCH ROSEMOUNT 710DU PDIS-049-2N657C SWITCH ROSEMOUNT 510DU PDS-049-IN660A SWITCH ROSEMOUNT 510DU PDS-049-IN660C SWITCH ROSEMOUNT 510DU PDS-049-2N660A SWITCH ROSEMOUNT 710DU PDS-049-2N660C SWITCH ROSEMOUNT 710DU PDT-049-IN057A TRANSMITTER ROSEMOUNT ll53DB5 h

PDT-049-IN057C TRANSMITTER ROSEMOUNT ll53DB5 PDT-049-2N057A TRANSMITTER ROSEMOUNT ll53DB6 PDT-049-2N057C TRANSMITTER ROSEMOUNT I153DB6

NSSSS RCIC STEAM SUPPLY PRESSURE-LOW (Safety Function)

TABLE 5 (Equipment Associated With Item 11 in August 8,1996 Submittal)

Page 1 of2 COMPONENT ID COMPONENT TYPE MANUFACTURER MODEL NUMBER E51A-K16A RELAY AMERACE EGP E51A-K16A RELAY AMERACE EGP E51A-K16C RELAY AMERACE EGP E51A-K16C RELAY AMERACE EGP E51A-K17A RELAY AMERACE EGP E51A-K17A RELAY AMERACE EGP E51A-K17C RELAY AMERACE EGP E51A-K17C RELAY AMERACE EGP PIS-049-IN658A SWITCH ROSEMOUNT 510DU PIS-049-IN658C SWITCH ROSEMOUNT 710DU PIS-049-IN658E SWITCH ROSEMOUNT 510DU PIS-049-IN658G SWITCH ROSEMOUNT 510DU PIS-049-2N658A SWITCH ROSEMOUNT 510DU PIS-049-2N658C SWITCH ROSEMOUNT 510DU PIS-049-2N658E SWITCH ROSEMOUNT 510DU PIS-049-2N658G SWITCH ROSEMOUNT 710DUOTT

?

NSSSS RCIC STEAM SUPPLY PRESSURE-LOW (Safety Function)

TABLE 5 (Equipment Associated With Item 11 in August 8,1996 Submittal)

~

Page 2 of2 COMPONENTID COMPONENT TYPE MANUFACTURER MODEL NUMBER FT-049-1N058A TRANSMITTER ROSEMOUNT 1153GB7PBN0016 FT-049-1N058B TRANSMrlTER ROSEMOUNT 1153GB7PBN0016 FT-049-1N058C TRANSMrlTER ROSEMOUNT 1153GB7PBN0016 FT-049-IN058D TRANSMITTER ROSEMOUNT I153GB7PBN0016 PT-049-1N058A TRANSMFITER ROSEMOUNr 115IGP7D22PB-M PT-049-2P 058B TRANSMTITER '

ROSEMOUNT 115IGP7D22PB-M FT-049-2).058C TRANSMITTER ROSEMOUNT I151GP7D22PB-M FT-049-2N058D TRANSMITTER ROSEMOUNT I15IGP7D22PB-M

NSSSS-RPS DRYWELL PRESSURE-HIGH (Safety Function)

~

TABLE 6 (Equipment Associated With Item 12 in August 8,1996 Submittal)

Page 1 of 2 COMPONENT ID COMPONENT TYPE MANUFACTURER MODEL NUMBER B21H-KilA RELAY AMERACE EGP B21H-KilA RELAY AMERACE EGP B21H-KilB RELAY AhERACE EGP B21H-KilB RELAY AMERACE EGP B21H-KilC RELAY AMERACE EGP B21H-K11C RELAY AhERACE EGP B21H-KilD RELAY AMERACE EGP B21H-KllD RELAY AhERACE EGP C71 A-K4A RELAY AhERACE EGP C71A-K4A RELAY AhERACE EGP C71A-K4B RELAY AhERACE EGP C71A-K4B RELAY Ah-ERACE EGP C71A-K4C RELAY AhERACE EGP C71A-K4C RELAY AhERACE EGP C71 A-K4D RELAY AhERACE EGP C71A-K4D RELAY AMERACE EGP

T NSSSS-RPS DRYWELL PRESSURE-HIGH (Safety Function)

TABLE 6 (Equipment Associated With Item 12 in August 8,1996 Submittal)

Page 2 of 2 COMPONENTID COMPONENT TYPE MANUFACTURER MODEL NUMBER C71A-K4D RELAY AMERACE EGP PIS--042-IN650A SWITCH ROSEMOUNT 510DU PIS--042-IN650B S%TTCH ROSEMOUNT SIODU PIS--042-IN650C SWITCH ROSEMOUNT SIODU PIS--042-IN650D SWITCH ROSEMOUNT 510DU PIS--042-2N650A SWfrCH ROSEMOUNT 710DU PIS--042-2N650B SWTFCH ROSEMOUNT 710DU PIS--042-2N650C SWITCH ROSEMOUNT 710DU PIS--042-2N650D SWITCH ROSEMOUNT 710DU FT-042-IN050A TRANSMITTER ROSEMOUNT I153GB5 PT-042-IN050B TRANSMITER ROSEMOUNT ll53GB5 FT-042-IN050C TRANSMITTER ROSEMOUNT I153GB5 FT-042-IN050D TRANSMITTER ROSEMOUNT ll53GB5 PT-042-2N050A TRANSMITTER ROSEMOUNT II51GP5 PT-042-2N050B TRANSMITTER ROSEMOUNT I151GP5 PT-042-2N050C TRANSMITTER ROSEMOUNT I15IGP5 FT-042-2N050D TRANSMITTER ROSEMOUNT I15IGP5 N.

e ECCS RX LEVEL LOW-LEVEL 1,2; DRYWELL PRESSURE-HIGH, RX PRESSURE LOW (Safety Function)

TABLE 7 (Equipment Associated With Item 13 in August 8,1996 Submittal)

Page 1 of 9 COMPONENT ID COMPONENT TYPE MANUFACTURER MODEL NUMBER SAFETY FUNCTION -

ElIA-KISA RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH ElIA-K15A RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH ElIA-KISB RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH ElIA-KISB RELAY AMERACE EGP ECCS DRYWELL PRESSURE-1DGH ElIA-K15C RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH ElIA-K15C RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH ElIA-KISD RELAY AMERACE EGP ECCS DRYWELL PRESSURE-lEGH El1A-K15D RELAY AhERACE EGP ECCS DRYWELL PRESSURE-HIGH ElIA-K16A RELAY ANERACE EGP ECCS DRYWELL PRESSURE-HIGH ElI A-K16A RELAY AMERACE EGP FCCS DRYWELL PRESSURE-lHGH ElIA-K16B RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH ElIA-K16B RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH El1A-K16C RELAY AhERACE EGP ECCS DRYWELL PRESSURE-lEGH ElIA-K16C RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH

l ECCS RX LEVEL LOW-LEVEL 1,2; DRYWELL PRESSURE-HIGH, RX PRESSURE LOW (Safety Function)

~

TABLE 7 (Equipment Associated With Item 13 in August 8,1996 Subnaittal)

Page 2 of 9 COMPONENTID COMPONENT TYPE MANUFACTURER MODEL NUMBER SAFETY FUNCTION El1A-Kl6D RELAY AMERAG EGP ECCS DRYWELL PRESSURE-HIGH L

ElIA-K16D RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E21A-K11A RELAY AMERAG EGP ECCS DRYWELL PRESSURE-HIGH E21A-K11A RELAY AMERACE EGP ECCS DRYWELL PRE.c4URE-HIGH E21A-K1IB RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E21A-KilB RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E21A-K1IC RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E21A-KilC RELAY AMERAG EGP ECCS DP,YWELL PRESSURE-HIGH E21A-K1ID RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E21A-K1ID RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E21 A-K12A RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E21 A-K12A RELAY AhERACE EGP ECCS DRYWELL PRESSURE-HIGH E21A-K12B RELAY AMERA EGP ECCS DRYWELL PRESSURE-HIGH E21A-K12B RELAY AMERAG EGP ECCS DRYWELL PRESSURE-HIGH t

m

ECCS RX LEVEL LOW-LEVEL 1,2; DRYWELL PRESSURE-HIGH, RX PRESSURE LOW (Safety Function)

TABLE 7 (Equipment Associated With Item 13 in August 8,1996 Submittal)

~

Page 3 of 9 COMPONENT ID COMPONENT TYPE MANUFACTURER MODEL NUMBER SAFETY FUNCTION E21A-K12C RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E21A-K12C RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E21A-K12D RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E21A-K12D RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E41A-K5B RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E41A-K5B RELAY AhERACE EGP ECCS DRYWELL PRESSURE-HIGH E41A-K5D RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E41A-K5D RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E41A-K6B RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E41A-K6B RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E41A-K6D RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E41A-K6D RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E41A-K74 RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E41A-K74 RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH

s ECCS RX LEVEL LOW-LEVEL 1,2; DRYWEL~L PRESSURE-HIGH, RX PRESSURE LOW (Safety Function)

TABLE 7 (Equipment Associated With Item 13 in August 8,1996 Submittal)

Page 4 of 9 COMPONENT ID COMPONENT TYPE MANUFACTURER MODEL NUMBER SAFETY FUNCTION E41A-K75 RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E41A-K75 RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E51A-Kl8A RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E51A-Kl8A RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E51A-Kl8C RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH E51A-Kl8C RELAY AMERACE EGP ECCS DRYWELL PRESSURE-HIGH LIS-042-2N691 A SWITCH ROSEMOUNT 710DU ECCS RX PRESSURE-LOW LIS-042-2N691B SWITCH ROSEMOUNT 710DU ECCS RX PRESSURE-LOW LIS-042-2N691C SWITCH ROSEMOUNT 710DU ECCS RX PRESSURE-LOW LIS-042-2N691D SWITCH ROSEMOUNT 710DU ECCS RX PRESSURE-LOW LIS-042-2N691E SWITCH ROSEMOUNT 710DU ECCS & NSSSS RX WATER-LEVEL 1,2,8 LIS-042-2N691F SWITCH ROSEMOUNT 710DU ECCS & NSSSS RX WATER-LEVEL 1,2,8 LIS-042-2N691G SWITCH ROSEMOUNT 710D0 ECCS & NSSSS RX WAHIR-LEVEL 1,2,8 LIS-042-2N691H SWITCH ROSEMOUNT 710DU ECCS & NSSSS RX WATER-LEVEL 1,2,8

ECCS RX LEVEL LOW-LEVEL 1,2; DRYWELL PRESSURE-HIGH, RX PRESSURE LOW (Safety Function)

(

TABLE 7 (Equipment Associated With Item 13 in August 8,1996 Submittal)

Page 5 of 9 COMPONENT ID COMPONENT TYPE MANUFACTURER MODEL NUMBER SAFETY FUNCTION PIS442-IN690A SWITCH ROSEMOUNT 510DU ECCS RX PRESSURE-LOW PIS-042-IN690B SWTTCH ROSEMOUNT 510DU ECCS RX PRESSURE-LOW PIS-042-IN690C SWITCH ROSEMOUNT 510DU ECCS RX PRESSURE-LOW PIS442-1N690D SWITCH ROSEMOUNT 510DU ECCS RX PRESSURE-LOW PIS-042-1N690E SWITCH ROSEMOUNT 510DU ECCS RX PRESSURE-LOW PIS-042-IN690F SWITCH ROSEMOUNT 510DU ECCS RX PRESSURE-LOW PIS-042-IN690G SWITCH ROSEMOUNT 510DU ECCS RX PRESSURE-LOW PIS-042-IN690H SWITCH ROSEMOUNT 510DU ECCS RX PRESSURE-LOW PIS-042-IN694A SWITCH ROSEMOUNT 510DU ECCS DRYWELL PRESSURE-HIGH PIS-042-1N6948 SWITCH ROSEMOUNT 510DU ECCS DRYWELL PRESSURE-HIGH PIS442-1N694C SWITCH ROSEMOUNT 510DU ECCS DRYWELL PRESSURE-HIGH PIS-042-IN694D SWITCH ROSEMOUNT 710DU ECCS DRYWELL PRESSURE-HIGH PIS-042-IN694E SWITCH ROSEMOUNT 510DU ECCS DRYWELL PRESSURE-HIGH PIS442-IN694F SWITCH ROSEMOUNT 510DU ECCS DRYWELL PRESSURE-HIGH

ECCS RX LEVEL LOW-LEVEL 1,2; DRYWELL PRESSURE-HIGH, RX PRESSURE LOW (Safety Function)

~

TABLE 7 (Equipment Associated With Item 13 in August 8,1996 Submittal)

Page 6 of 9 COMPONENTID COMPONENT TYPE MANUFACTURER MODEL NUMBER SAFETY FUNCTION PIS-042-IN694G SWITCH ROSEMOUNT 510DU ECCS DRYWELL PRESSURE-HIGH PIS-042-1N694H SWTTCH ROSEMOUNT 5ICO'i ECCS DRYWEli PRESSURE-HIGH PIS442-2N690A SWITCH ROSEMOUNT 710DU ECCS RX PRESSURE-LOW PIS-042-2N690B SWITCH ROSEMOUNT 510DU ECCS RX PRESSURE-LOW PIS-042-2N690C SWITCH ROSEMOUNT 510DU ECCS RX PRESSURE-LOW PIS442-2N690D SWITCH ROSEMOUNT 510DU ECCS RX PRESSURE-LOW PIS-042-2N690E SWITCH ROSEMOUNT 510DU ECCS RX PRESSURE-LOW PIS-042-2N690F SWITCH ROSEMOUNT 510DU ECCS RX PRESSURE-LOW PIS-042-2N690G SWITCH ROSEMOUNT 510DU ECCS RX PRESSURE-LOW PIS-042-2N690H SWITCH ROSEMOUNT 510DU ECCS RX PRESSURE-LOW PIS-042-2N694A SWITCH ROSEMOUNT 710DU ECCS DRYWELL PRESSURE-HIGH PIS-042-2N694B SWITCH ROSEMOUNT 510DU ECCS DRYWELL PRESSURE-HIGH PIS-042-2N694C SWITCH ROSEMOUNT 510DU ECCS DRYWELL PRESSURE-HIGH PIS-042-2N694D SWITCH ROSEMOUNT 510DU ECCS DRYWELL PRESSURE-HIGH

D

^

ECCS RX LEVEL LOW-LEVEL 1,2; DRYWELL PRESSURE-HIGII, RX PRESSURE LOW (Safety Function)

TABLE 7 (Equipment Associated With Item 13 in August 8,1996 Submittal)

Page 7 of 9 COMPONENT ID COMPONENT TYPE MANUFACTURER MODEL NUMBER SAFETY FUNCTION PIS-042-2N694E SWITCH ROSEMOUNT 510DU ECCS DRYWELL PRESSURE-HIGH PIS-042-2N694F SWITCH ROSEMOUNT 510DU ECCS DRYWELL PRESSURE-HIGH

[

PIS442-2N694G SWITCH ROSEMOUNT 510DU ECCS DRYWELL PRESSURE-HIGH PIS-042-2N694H SWITCH ROSEMOUNT 710DU ECCS DRYWELL PRESSURE-HIGH I

FT-042-1N090A TRANSMITTER ROSEMOUNT I153GB9 ECCS RX PRESSURE-LOW PT-042-IN090B TRANSMTITER ROSEMOUNT I153GR9 ECCS RX PRESSURE-LOW PT-042-IN090C TRANSMITTER ROSEMOUNT I153GB9 ECCS RX PRESSURE-LOW PT-042-IN090D TRANSMIFTER ROSEMOUNT I153GB9 ECCS RX PRESSURE-LOW i

PT-042-1N090E TRANSMrITER ROSEMOUNr 1153GB9 ECCS RX PRESSURE-LOW FT-012-1N090F TRANSMITTER ROSEMOUNT 1153GB9 ECCS RX PPESSURE-LOW

[

PT-042-1N090G TRANSMrlTER ROSEMOUNT I153GB9 ECCS RX PRESSURE-LOW PT-042-IN090H TRANSMTITER ROSEMOUNT 1153GB9 ECCS RX PRESSURE-LOW PT-042-1N094A TRANSMFITER ROSEMOUNT I153GB5 ECCS DRYWELL PRESSURE-HIGH PT-042-IN094B TRANSMITTER ROSEMOUNT I153GB5 ECCS DRYWELL PRESSURE-HIGH a

m

i ECCS RX LEVEL LOW-LEVEL 1,2; DRYWELL PRESSURE-HIGH, RX PRESSURE LOW (Safety Function)

TABLE 7 (Equipment Associated With Item 13 in August 8,1996 Submittal)

Page 8 of 9 COMPONENT ID COMPONENT TYPE MANUFACTURER MODEL NUMBER SAFETY FUNCTION FT-042-lN094C TRANSMITTER ROSEMOUNT 1153GB5 ECCS DRYWELL PRESSURE-HIGH PT-042-IN094D TRANSMITTER ROSEMOUNT I153GB5 ECCS DRYWELL PRESSURE-HIGH t

PT-042-IN094E TRANSMITER ROSEMOUNT I153GB5 ECCS DRYWELL PRESSURE-HIGH L

FT-042-1N094F TRANSMITTER ROSEMOUNT 1153GB5 ECCS DRYWELL PRESSURE HIGH FT-042-IN094G TRANSMITTER ROSEMOUNT I153GB5 ECCS DRYWELL PRESSURE-HIGH FT-042-IN094H 1RANSMITTER ROSEMOUNT I153GB5 ECCS DRYWELL PRESSURE-HIGH FT-042-2N090A

'IRANSMITTER ROSEMOUNT I151GP9 ECCS RX PRESSURE-LOW FT-042-2N090B TRANSMITTER ROSEMOUNT 1151GP9 ECCS RX PRESSURE-LOW FT-042-2N090C TRANSMITTER ROSEMOUNT 1153GB9 ECCS RX PRESSURE-LOW l

PT4)42-2N090D TRANSMITTER ROSEMOUNT 1153GB9 ECCS RX PRESSURE-LOW PT-042-2N090E TRANSMITER ROSEMOUNT I151GP9 ECCS RX PRESSURE-LOW FT-042-2N090F TRANSMTITER ROSEMOUNT 1151GP9 ECCS RX PRESSURE-LOW PT-042-2N090G TRANSMTITER ROSEMOUNT I151GP9 ECCS RX PPESSURE-LOW PT-042-2N090H TRANSMTITER ROSEMOUNT I151GP9 ECCS RX PRESSURE-LOW I

o-ECCS RX LEVEL LOW-LEVEL 1,2; DRYWELL PRESSURE-HIGH, RX PRESSURE LOW (Safety Function)

TABLE 7 (Equipment Associated With Item 13 in August 8,1996 Submittal)

Page 9 d 9 COMPONENT ID COMPONENT TYPE MANUFACTURER MODEL NUMBER SAFETY FUNCTION FT-042-2N094A TRANSMITTER ROSEMOUNT I153GB5 ECCS DRYWELL PRESSURE-HIGH PT-042-2N094B TRANSMITTER ROSEMOUNT I151GB5 ECCS DRYWELL PRESSURE-HIGH FT-042-2N094C TRANSMITTER ROSEMOUNT 1151GB5 ECCS DPdM PRESSURE-HIGH FT-042-2N094D TRANSMITTER ROSEMOUNT ll51GB5 ECCS DRYWELL PRESSURE-HIGH PT-042-2N094E TRANSMITTER ROSEMOUNT I151GB5 ECCS DRYWELL PRESSURE-HIGH FT-042-2N094F TRANSMTITER ROSEMOUNT I151GB5 ECCS DRYWELL PRESSURE-HIGH PT-042-2N094G TRANSMITTER ROSEMOUNT 1151GB5 ECCS DRYWELL PRESSURE-HIGH FT-042-2N094H TRANSMITTER ROSEMOUNT I151GB5 ECCS DRYWELLPRESSURE-HIGH t

-