Responds to 781031 NRC Ltr Re Violations Noted in Inspec Repts 50-254/78-21 & 50-265/78-22.Corrective Actions:Areas Req Housekeeping Were Cleaned,No Smoking Rules Enforced, Procedure QAP 200-13 Is Being Rev
ML20148T703
Person / Time
Site: Quad Cities  
Issue date: 11/20/1978
From: Reed C
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
NUDOCS 7812060020
Download: ML20148T703 (2)


Text

,

@ One First National Plaza, Chicago, Ilhnoi Commonwonith Edisen

[

Address Reply to: Post Othee Box 767 Chicago. Illinois 60690 November 20, 1978 Mr. James G.

Keppler, Director Directorate of Inspection and Enforcement - Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137

Subject:

Quad-Cities Station Units 1 & 2 Response to IE Inspection Report Nos. 50-254/78-21 and 50-265/78-22 NRC Docket Nos. 50-254/265 Reference (a) :

G.

Fiorelli letter to B. Lee, Jr.

dated October 31, 1978

Dear Mr. Kepp3er:

The following is in response to an inspection conducted by Messrs.

I.

N.

Jackiw, N. J. Chrissotimos and C..H.

Brown on August 21-25, 31, September 1, 6-7, 13-14 and October 3-4, 1978 of activities at Quad-citier; Station Units 1

& 2.

Reference (a) indicated that some activities appeared not to be in conformance with commitments to the Commission.

Our response to this item is enclosed in the attachment to this letter.

Please address any additional questions on this matter to this office.

Very truly yours, N. s. &eed rdell R W

v Assistant Vice-President attachment

":V 311978 78120goaz0 2060

,w

Commonwealth Edison ' NRC Docket Nos. 50-254/265 V

DEVIATION Contrary to the licensee's commitments made in CE-1-A Topical Report Revision 4 (March 10, 1978) to comply with the requirements of. Appendix B to 10 CFR Part. 50 and to follow the QA guidance provided by the NRC in Regulatory Guide 1.39, Revision 2; and other Regulatory Guides, and ANSI Standard N45.2.12, Draft 3, Revision 4, 2-74, the control procedures for housekeeping and control of transient flammable material appeared tx) be deficient as shown by the following ' examples and other items pointed out to the licensee representatives during the review:

1.

Excessive amounts of oil (new and used) stored without protection near vital cabling; 2.

Smoking in vital areas, marked as No Smoking Area; t

3.

Welding areas set up near vital cabling.

i Discussion This item was brought up as a result of the in-plant tour conducted by the NRC Fire Protection Evaluation Team during their site' visit.

This was a non-routine inspection; and although a few areas were found where housekeeping was deficient, the majority of the areas of the facility were clean, and so adverse reactor safety conditions were present.

Corrective Action The areas found to be in need of better housekeeping have been cleaned.

The space between the control room panels has

,been cleaned up, as has the cable spreading room.

Control of the i

non-smoking areas is being more closely monitored.

Bulk drum oil storage has been discontinued in the reactor building where vital cabling exists.

However, oil is being stored in smaller metal containers to facilitate proper maintenance of running equipment.

j Welding areas in the plant are set up sufficiently away from vital cabling, and procedure. QMP 100-3, Fire Prevention for Welding and cutting, provides adequate fire prevention control.

Further, procedure QAP 200-13, Station Housekeeping Organization, is being revised so as to be more up-to-date and inclusive.