IE Inspec Repts 50-566/78-7 & 50-567/78-7 on 780927-28 During Which No Items of Noncompliance Were Noted.Major Areas Inspected Incl:Overall Construction Status,Observation of LWA Activities,Review of Receiving Inspec Documents
ML20148Q144
Person / Time
Site: Yellow Creek  
Issue date: 10/18/1978
From: Gouge M, Wright R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20148Q141 List:
References
50-566-78-07, 50-566-78-7, NUDOCS 7811290323
Download: ML20148Q144 (4)


Text

.

UNITED STATES

\\

- [f. 40 NGog (9

NUCLEAR REGULATORY COMMISSION 4

4o REGloN il 5

c 101 M ARIETT A STREET, N.W.

ATL ANT A, GEORGI A 30303 k

p Report Nos.:

50-566/78-7 and 50-567/78-7 Docket Nos.:

50-566 and 50-567 License Nos.:

LWA 1 and 2 Category:

A1, Al Licensee: Tennessee Valley Authority 830 Power Building Chattanooga, Tennessee 37401 Facility Name:

Yellow Creek Nuclear Plant, Units 1 and 2 Inspection at:

Yellow Creek Site, Tishomingo County, Mississippi Inspection Conducted:

September 27-28, 1978 Inspectors:

R. W. Wright M. J ou e Reviewed by:

[

/d 8/78 A. R. Herdt, Chief

'Da t'e Projects Section Reactor Construction and Engineering Support Branch Inspection Summary Inspection on September 27-28, 1978 (Report No. 50-566/78-7 and 50-567/78-7)

Areas Inspected:

Announced inspection to transfer principal inspector duties; overall construction status; observation of LWA activities; review of receiving inspection documents (reinforcing steel). Inspection involved 16 inspector-hours on site by two NRC inspectors.

Results: No items of noncompliance or deviations were identified.

7-811299323

{

- ~ -

RII Rpt. Nos. 50-566/78-7 and 50-567/78-7 I-1

'l[

/6[////f DETAILS I Prepared M. J. Gouge, Principal Inspector date Projects Section Reactor Con truction and Engineering Support Branch Al

/0 R. W. Wrigfit, Principal Inspector a te l

Projects Section i

Reactor Construction and Engineering Support Branch Dates of Inspect eptember 27-28, 1978 Reviewed by:

8 A[

/0 A. R.~Herdt, Chief ate Projects Section Reactor Construction and Engineering Support Branch 1.

Persons Contacted

  • M. M. Price, Project Manager
  • L. C. Cox, Construction Engineer
  • S. Carr, Assistant Construction Engineer (PE)
  • C. G. Wages, Assistant Construction Engineer (QC)
  • R.

Delay, Supervisor, Materials and Civil QC Unit J. N. Holladay, Supervisor, Project QA Unit D. Briggs, Supervisor, Mechanical QC Unit G. Livingston, Supervisor, Electrical QC Unit

  • S. E. Alge, Supervisor, Document Control Unit
  • J. R. Daniel, Materials QC Unit J. Johnson, Materials QC Unit
  • S. Watson, Document Control Unit
  • J. B. Nelson, Project QA Unit
  • Denotes those present at the exit interview conducted September 28, 1978.

2.

Licensee Action on Previous Inspection Findings This area was not inspected.

3.

Unresolved Items

e 2

RII Rpt. Nos. 50-566/78-7 and 50-567/78-7 I-2 No new unresolved items were identified during the inspection.

4.

Independent Inspection Effort a.

Transfer of Principal Inspector Duties Principal Inspector duties were transferred from R. W. Wright to M. J. Gouge. Mr. Gouge was introduced to key personnel in the TVA site organization. The responsibilities of key personnel and the progress of construction personnel staffing were reviewed.

b.

Construction Status The inspectors made a visual inspection of the Yellow Creek Nuclear Plant (YCNP) construction activities in progress to observe current construction status and to ascertain that the licensee was continuing to work within the scope of activities authorized by 10 CFR Sections 50.10(e)(1) (LWA-1) and 50.10(e)(3)

(LWA-2) as granted by NRR's letter dated February 9, 1978.

Upgrading of onsite roads, construction of drainage facilities, warehouse, office, shop and storage facilities are continuing operations. Blasting of bedrock is in progress for Units 1 and 2 reactor buildings at approximately elevation 461 feet. Condenser Circulating Water (CCW) system piping is being assembled in the vicinity of Unit 1 turbine building excavation. Some forms have been erected for Units 1 and 2 turbine building foundations. The central-mix batch concrete plant has been erected but not qualified. The four onsite desilting ponds are completed and in operation.

c.

Review of Receiving inspection Documents (Reinforcing Steel)

Receiving Inspection Checklists (form TVA 10152) and Certified Mill Test Reports were reviewed for various heats of grade 60 reinforcing steel that had been received on site.

The above records were checked for compliance with Receiving Inspection, Storage and Preventive Maintenance Procedure C-301 (Reinforcing Steel).

No deviations 'or items of noncompliance were identified within the above areas examined.

'.(II Rpt. Nos. 50-566/78-7 4

and 50-567/78-7 I-3 5.

Exit Interview The inspectors met with licensee representatives listed in paragraph I at the conclusion of the inspection on September 28, 1978.

The new principal inspector was formally introduced to site management and the licensee was apprised of the scope of the findings of the inspection which included construction status, observation of LWA activities, and receiving inspection documentation (reinforcing steel). No deviations or items of noncompliance were disclosed.

1 m

0 e

f