N GENERAL:

) ELECTRIC NUCLEAR ENERCfY

~ g imCM) vr sx,

3 PRODUCTS DIVISION WILMINCTON MANUF ACTURING CASTLE HAYNE ROAD e P. O. DoX 780. WILMINGTON, N. C. 28401. (9 A* ' 'pd...,

EM October 19, 1978 uy

}U' Director 4.

"OTlCH Office of Nuclear Material Safety & Safeguards WP U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Rnosvgo sy LFMu !

Attention: Mr. L. C. Rouse, Chief 1ca:e,.(0/,'.Tph,,,,

Fual Processing & Fabrication Branch

]

gg

,. g...

Dear Sir:

{cy,,, Q,,,,,,,,

References:

(1) NRC License SNM-1097, Docket #70-1113 I, Orig.'

(2) Application Amendment N-1 dated 8/3/78 t

Acuc...:c mpi............

Subject:

MODIFICATION 1 TO APPLICATION AMENDMENT N-1 With reference to activities authorized by SNM-1097, on 8/3/78 General Electric Company requested authorization to use a particular canister with full face masks which is currently being evaluated for approval by the National Institute of Occupational Safety & Health (NIOSH). The canister identification given in this request was incorrect.

The correct identification for the canister is 88182 GMR, to be used with the MSA chin-type gas mask with Ultravue or Clearvue Face Piece #457111.

With respect to the request by your staff for information related to the application made by the Mine Safety Appliance Corporation (MSA) to NIOSH, attached is a copy of that application letter including references to the actual d,ata supplied by NIOSH.

Your staff further requested that a copy of the data sent to NIOSH in support of the attached application also be submitted in order to complete evaluation of our request. Therefore, we will request a copy of the data from MSA and forward to you upon receipt.

Very truly yours, 8

GENERAL ELECTRIC COMPANY [3 ana n

/,'

m~ 003 0

u

~'

7 43?" 3

,n Arthur L. Kaplan, Manager \\

7

~m Licensing & Compliance Audits.

rf 4

M/C J26 h

ALK:bmw f -

Attachment y-gy;1 ;{/ n.M. '

,i'id Sg4Mid n NSD-L*

L.1,.".scj<n 781127 o 7 6

vv v

July 28, 1978 I

Hr. Richard H. Ronk Testing and Certification Branch 944 Chestnut Ride,e Road,,

Horgantown, West Virginia 26505

~,

l

SUBJECT:

NIOSU Approval for itSA Chin l

Style Gas Hask Dear Mr. Rook It is hereby respectfully requested that NIOS!! approval certification under 30 CFR, Part 11 is Granted to the following MSA clearvue and ultra-vue full facopiece gas mask assemblies which consist of a facepiece and i

l e chin canister.

1.

G11C-C Chin style Gas Mask

, Pa r t No._

m.,r,.ineenn 466227 Gas Flask, Clearvue, Glic-C, Chin Style 466228 Cao Mask, Ultravue, Gt!C-C, Chin "tyle 466350 Gas Haak, Ultravue, GMC-C, Chin Style, in case 466351 Gas Mask, Cicorvue, GMC-C, Chin Style, in case

)

', 466222 Canister, Gt!C-C The GitC-C full faceptoca, chin style gaa masks are equipped with replace-oble chio mounted canistera and are designed for use as respiratory pro-tection during entry into and escape from or escape only from harsrdous eteespheres containf ng at 1 cast 19.57, oxygen, up to 0.57. organic vapora or

)

ocid Canes, and/or (

'ta and mists haviog an air contamination level not i

less than 0.05 milli, 2ms per cubic meter of air.

l These GHC-C gas ensk assemblica have boa s subjected to the required tests l

described in Subparta 1 and K of Title 30 CFR, Part 11. The following tables of data are attached:

l Table LA - 0.5% Carbon Tetrachloride Tests Table 1B - 0.51 Chlorine Toots Table IC - 0.5% Sulfur Dioxide Tests Table ID - Silica Dust Tects Tablo 1E - Silica Hist. Tests 2.

CHR-1 Chin Style Gas 11ssks

{

i

?.

I

-i.es nee se==*

+w~

,s w-4 4

s<-

9 m

4

m.=. -

n.na.w. a. a

.w._.-

e.

y e

f O.

O 6

0 Fase'2 Hr. Richard H. Reak July 28,1978 tMoeription Pnrt No..

466229 Gas 11ask, Clearvue, G.'R-1, Chin Style 466230 Cas Hank, tJitrevue, C E -1, Chin Style 466220.

Canister, GMR-1 The CMR-I full facepiece, chin style gas masks are equippped with replace-able chin mounted canisters and are designed for use as respiratory pro-

,4 tection during entry into and escape from or escape only from bazardous atmospheres containing.at least 19,5%. oxygen, up to 0.5% organte vapors,-

, and/or. dust's, mists and fumeis having an air contamination level less than

/

$'(

0.05 milligrams per cubic meter, or against radionuclides, s

(

These C)m-1 gas mask assemblies have been ' subjected to the required tests se J

l described in Subparts I and K of Title 30 CFR, Part 11. The following

.]'

I tables of data are attached

~

,t.

Table 2A '- 0.5% Carbon Tetrachloride Tests

/p' Table 25 - Silica Dust Testa

,a Table 2C, DOP Tests s

p 6

t-CMR-S Chin Style Gas Masks,

j

. ' ' M

.3..

~

1 3'

'r 2

[

' 'Part No._

'6eseription l

466231,

. Gas Ibsk, Cic,orvue, G)2-S, Chin Sty e

]

jc j

' [,

466232

' Gas linck, Ultravue, GMR-S,. Chin Style

+

466219 Canister, Gem-S j.

N The GE-S full facepieco, chin style gas masks are equipped with replace-k able chin nountad canisters and are designed for use as respiratory pro-tcction during entry into and escape from or escapo only from ha::ardous s,

'[

atmospheres containing at least 19.5% oxygen, up to 0.5% chlorino, and/or g ',:,

dust, mists,and furr.ac having an air contamination level less than 0.05 N/-

milligrams per cubic' motor or,against radionue11 des.

't

i, The Gla-S gas manks assemblies have been subjected'to the required tests

.l

[

described in Subparts I and K of Title 30, Part 11. The following tables are attached:

j Table 3A - 0.5% Chlorine Tests 3~

7#*

Table 3D - Silica Dust Tests Table '3C - DOP Tests j

j } {.

$l:

h:

9

- 4.

CIR-C Chin Style Gas Maska U

y a?

Part Mo'.

Tvreription

~

,I 1f,g, 457111

'466225 cas Itawk, clearvum, G M-C, Chin Style 457111 - 466226-Can Monk, Ultravuo, GMa-C, Chin Style 88182 - 466221-CHR-C Canister 7:1 ;

ff.

h.

1 0[

9 4

.,.n

,n..,

x

..m...

7

,, g.

}&. Richard H. R k July 28,1978 The CHR-C full facepiece chin atyle gas maoks are equipped with replace-able chin mounted canisters sad are designed for use ao respiratory pro-taction during entry into and escape from or escape only from hszardous atmosphores containing at least '19.5% oxygen, up to 0.51 chlorine, and/or dusts, mists and fumes having an air contamination level less than 0.05 milligrams per cubic meter, or against radionuclides.

These GKR-C Gas Fbsks assemblies have been subjected to the required tests i

described in Subparts I and K of Title 3D CFR, Part 11. The following tables of dato are attached; Table 4A - 0.5% Chlorine Tests s

Table 4D - Silica Dust Tests Table 4C - DOP Tests The following tables of data, which are relevant to all of the assemblies are attached:

Tablo 5 - DOP Han Work Testo, Clearvue Facepiece Table 6 - DOP tbn Work Tosts, Ultravue Facepiece Table 7 - Exhalation Valve Tests, Ultravue and Cicarvue Facepieces An engineering package of drawing lists, drawings and specifications not previously cubmitted on other packages, and test data is attached for each of the assemblics listed in Sections 1 through 4.

The basic clearvue f ace-piece, 7-223 and the banic ultravue facepiece, 7-203 were previously approved by NIOSH. The canisters are new approvals.

The quality control procedures (C/D'a) have not been completely written and will be nupplied by Quality Control when they are available.

Those which are available and have not been previously submitted are attached to the package.

All parto of the gas mask assemblies are production parts.

Samples of canisters being submitted to'NIOSil for approval are available from Engineering.

Please advise the feo required for this approval and if any additions 1 information is needed, please contact the undersigned.

Very truly yours, I. D. McConnell Defenom Products Department TDticcidsp Att.

.k fpe' i.

9 *

-