Fuel Melt Review Group Meeting The WRSR Fuel Melt Review Group will meet on Monday and Tuesday, November 27 and 28,1978, at Sandia National Laboratory, Albuquergee, New Mexico.' The purpose of this meeting will be to review the Sandia steam explosion and molten core / concrete interaction research programs.
Safety researchers from the Federal Republic of Germany will also be participating in this meeting as part of our bilateral information exchange agreement.
The preliminary agenda for this meeting and a partial list of meeting participants is attached.
Please inform me at (301) 427-4266 by Friday, November 15, 1978, if you plan on attending so that the necessary arrangements can be made.
Sincerely, D
R'ichard Sherry, Chai ia n Fuel Melt Review Group Fuel Behavior Research Branch Division of Reactor Safety Research
Enclosure:
As stated 7811220L E
^
FUEL MELTDOWN PROGRAM REVIEW AND USA /FRG INFORMATION EXCHANGE MEETING PRELIMINARY AGENDA Monday, November 27, 1978 Morning
- Tour Sandia Experimental Facilities Afternoon - Overview of FRG and USA Fuel Meltdown Research, W. Johnston
& R. Sherry, NRC, E. Herkommer & F. Mayinger, FRG
- Steam Explosion Research Sandia Steam Explosion Program, L. Nelson & L. Buxton, Sandia o Review of small scale tests o Review of intennediate scale low instrumented tests o Preliminary design, instrumentation and planned experi-ments for intermediate scale instrumented tests Steam Explosion Research in the FRG, M. Peehs, KWU, et.al.
Status of Steam Explosion Research, R. Henry, ANL Tuesday, November 28, 1978 Mo rning
- Melt / Concrete Interactions Studies Sandia Melt / Concrete Interactions Experiments, D. Powers, Sandia Melt / Concrete Interactions and Melt Composition Research in the FRG, M. Peehs, et.al.
Sandia Advanced Melt / Concrete Interactions Code, J. Muir, Sandia Molten Fuel Heat Transfer Phenomena, F. Mayinger, T. U. Hannover Afternoon - Fuel Meltdown Overview Battelle Meltdown and Fission Product Transport Code Develop-ment (MARCH / CORRAL, TRAP), P. Cybulskis, BCL German Mel tdown Code Development, K. Hassman, KWU, et.al.
Summary Discussion of Fuel Meltdown Research Wednesday, November 29, 1978 Morning
- Informal Meeting NRC Research Staff and FRG Representatives
_2-Pa rticipants Federal Republic of Germany Prof. Mayinger, T. U. Hannover Dr. Herkomer, GRS Dr. Peehs, KWU, Erlangen Dr. Hassman, KWU, Erlangen United States of America R. Sherry, NRC Dr. Johnston, NRC Dr. Powers, Sandia Dr. Buxton, Sandia Dr. Nelson, Sandia l
Dr. Muir, Sandia i
Dr. Henry, ANL Dr. Cybulskis, BCL l
NRC Water Reactor Safety Research Fuel Melt Review Group 1