' Form N 418 U.S. RUCLEAR R3oULATORY COMMISSION h2;731, CERTIFICATE OF COMPLIANCE g7
,g For Radioactive Materials Packages 1.ta) Certificate Number 1.(b) Revisica nio.
1.(c) Package identification No.
1.(d) Pages No 1 (e) Total No. Paget 9100 1
USA /9100/A 1
3
- 2. PREAMBLE 2 (a) This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardou Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.
2.(b)
The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 71, " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."
2.(c)
This carr:ficato does not relieve the consynor from compliance with any 'Quirement of the regulations of 'the U.S. Department of Transportation or other applicable regulatory agencies, including the gove.nment of any country through or into which the package will be transported.
- 3. This certificace is issued on the basis cf a safety analysis report of the package design or applicatiord-3.(a)
Prepared by (Name and address):
3.(b)
Title and identification of report or application:
Kerr-McGee Nuclear Corporation Kerr-McGee Nuclear Corporation applicaticn Kerr-McGee Center dated March 16, 1978, as supplemented.
Oklahoma City, Oklahoma 73125 3.(c)
Docket No. 71-9100
- 4. CONDITIONS This certificate is corditional upon thw fulfilling of the requirements of Subpart O of to CFR 71, as applicable, and the conditions specified in item 5 below.
- 5. Description of Pxkaging and Authorized Contents, Model f' umber, Fissile Class, Other Conditions, and
References:
(a) Packaging (1) Model No.:
KKP-20-4950 (2) Description The container is a 4950 gallon stainless steel cylindrical tank supported by a trusa-type #ramework on a motor vehicle trailer.
The 1/4" thick tank is 82-1/2" in diameter with an overall length of 229" including the torispherical end bulkheads.
Seven flanged, asbestos-gasketed access ports and a rupture disk are provided on the top surface. The tank is covered with an aluminum shell enclosing 3" fiberglass insulation.
The tank is supported by bolsters attached to a 238-1/2" x.96" x 96" angle, channel and I-beam frame which is attached to a trailer at four points.
Excluding the trailer, the gross weight of the packaging is 55,000 pounds.
(3) Drawings The phkaging is fabricated according to Fruehauf Corporation Drawing No. BKY 9010-1, Revision A.
The container chassis is described in Fruehauf Corporation Drawing No. B-ND4798, Revision B.
7811200 64
- Page 2 - Certificate No. 9100 - Revision No.1 - Docket No. 71-9100 5.
(Continued)
(b) Contents (1) Type and form of material Uranium ore concentrate in a water slurry form which meets the requirements as low specific activity radioactive material as aefined in 10 CFR 571.4(g).
(2) ilaximun quantity of material per package 42,000 pounds 6.
Prior to each shipment, an inspection of the tank anJ support frame shall be conducted according to the procedures stated in the Kerr-McGee Nuclear Corporation letter dated April 28, 1978. If the inspection reveals any deformation or weld cracking, the package shall be removed from service until repaired.
In addition, a liquid penetrant test of the entire length of the ring to tank weld at the bolsters shall be conducted in accordance with ASME,Section V, Article 6, at least every 10,000 miles (loaded).
If any cracks, as defined in accordance with ASME,Section VIII, Division 1, Appendix 8, Paragraph UA-93(a), are detected, the packaging shall be repaired and reinspected prior to use and shall be inspected prior to each shipment thereafter.
Any defect", shall be reported in accordance with 10 CFR 571.61.
7.
If loaded, the container hall not be lifted.
8.
The package authorized by this certificate shall be transported or, a motor vehicle assigned for the sole use of the licensee.
9.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).
10.
Expiration date: May 31, 1983 O
m'l 9
0 g
~
I Page 3 - Certificate No. 9100 - Revision No.1 - Docket No. 71-9100 REFERENCES Kerr-McGee Nuclear Corporation Application dated March 16, 1978.
Supplements dated: April 10 and 28, 1978.
Ranchers Exploration and Development Corporation application dated October 19, 1978.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION
<E Charles E. MacDonald, Chief Transportation Branch Division of Fuel Cycle and Material Safety.
Date:
.,