N:rthzst t 7 sei&o s=s saim, er 06037 Utiliti:s System sonhe t untie. suvice company a

P.O. Bos 270 Hartford,CT06 410270 (203) 665 5000 May 28,1997 Dil129 Central Permit Processing Unit Department of Environmental Protection 79 Elm Street Hartford,CT 06106 l

I

Dear Sir or Madam:

Millstone Nuclear Power Station J.glividual Permit Application for Diesel Comoressor Northeast Nuclear Energy Company (NNECO) herein submits an individual permit application for the temporary operation of a Detroit Diesel #PTMS 900 compressor. The compressor will be used during maintenance activities of the service air system at Millstone Nuclear Power Station's (MNPS) Unit 3.

The installation date of the compressor will be on or about July 20,1997 and it is expected to operate 24 l

hours per day for five to ten days. When the compressor is no longer necessary, NNECO expects to submit to the Department of Environmental Protection (DEP) a written request to withdraw the individual permit.

i Check No. 211215 for $500.00 is enclosed to cover the application fee. NNECO requests that DEP l

expedite the processing of this application in light.of the shon lead time before the scheduled service air system maintenance activities take place.

J If you have any questions on this individual permit application, or if there is any problem with i

expediting, please contact Mr. Paul Jacobson, Manager, Environmental Services-Nuclear at (860) 447-1791 extension 2335.

Very truly yours, i

i l

Jayphayer

/

l Recovery Officer - Nuclear Engineering and Support Overview

\\

\\

q0 (

j Enclosures 0

l cc:

w/o enclosures S. Scace, Director Nuclear Engineering Programs NRC w/ enclosures Mr. Rickey L. Bouffard, DEP l

1f;0002 lIllMil 9706180433 970528 1l1111llllfll Illy llsu lmllluullml0lplll llll llH1 jll PDR ADOCK 05000423

a p

PDR.

f

i ATTACHMENT 1 PERMIT APPLICATION FORM EPAC-22A-1 TEMPORARY USE OF ATLAS COPCO l

DIESEL COMPRESSOR

  1. PTMS900 AT l

MILLSTONE NUCLEAR POWER STATION UNIT 3 l

MAINTENANCE OF SERVICE AIR SYSTEM l

o l

l i

l

PAGE 1 OF 4

..[.' '

PERMIT APPI_1 CATION FOR FPAC-22A-1 (Rev'.

10/92)

PERMIT TO CONSTRUCT / OPERATE FUEL BURNING EQUIPhENT STATE OF CONNECT 1 CUT DEPARThlENT OF ENV1RONhENTAL PROTECTION i

liUREAU OF AI R htANAGEhfENT sirriON A Northeast Nucler Tnergy Company 860-665-5000 l

a l

1. LEGAL FIRM.NAAE:

Phone:

r.0. Box z/u nartiord, c1 06141-0270

2. ADDRESS:

Millstone Nuclear Power Station - Watertord, cI

3. EQUIPMENT LOCATION:
4. EOUIPMENT DESCRIPTION (DOILER & BURNER ADDEL.

I.D. *)-

l Tortable Compressor - Atlas COPCO Detroit Diesel PTMS #900

5. EQUIPMENT IS:

l

  • New Installation Replacement Modification Previous Permit / Reg. No.

6.

-LIST OTHER SOURCES VENTED TO STACK:

7. ESTIARTE TIIE FOLLOWING DATES:

Approx.. July 20, 1997 Start-up of Construction Approx. July 20. 1997 Comple:lon of ConstructionApprox. July 20, lyy/

Start-up of Equipment l

8. DIESEL GENERATORS ONLY:

(

EQUIPMENT IS:

X

_.__ Emergency Non-emergency sFr* TION B PART l.

OPERATIONAL-CONT) t TI ON S Diesel l

l

a. Fuel Type (s) (List all):

15.7 gallons per nr.

b. Maximum Fue1 Firing Rnte(s):

2 15)

c. Design Gross Ileat Input (hN BTUH) :
d. Minimum Hourly Exhaust Gas Flow Rate (ACFM):

2140 at 3W'F 500( f t ) D 5 8.0 Stack Height (ft):

I.D.

e.f. Minimum Distance to Property Line (ft):3147 gallons

g. Maximum Annual Fuel Consumption (s):

0.05

h. Sulfur in Fuel (% by weight):

24 240

1. Maximum Hours of Operation:

Daily Annually t

= =.

I.

Office Use Only - EPE No:

3 1

l 1

        • 8 g

e.

l

W

~~

1

~

l

',a s.

PERMIT APPI_1 CATION FOR EPAC-22A-1 (Rev. 7/92) e' PART II. - AIR PO1.1.11 TION CONTROL. FOlli PAGNT

't NOTE:

Indicate range if applicable b one

_.Serubber Make and Model:

Reagent.

Reagent Flowrate :

Pressure Drop (in M 0):

Minimum Gas Flowrtte at Maximum Rated Capacity (acfm):

Pil:

Design Outlet Grain Loading (gr/dsef):

Design Removal Efficiency (%):

Electrostatic Precipitator (ESP)

Make and Model:

Number of Fields:

Minimum Gas Flowrate at Maximum Rated Capacity (acfm):

Design Outlet Grain Loading (gr/dscf):

Design Removal Efficiency (%):

i i

_ Cyclone

_ Multicyclone 1

l Make and Model:

Pressure Drop ( i n 11. 0 ) :

Minimum Gas Flowrate at Maximum Rated Capacity (acfm):

_ Selective Non-catalytic Reduction (SNCR)

.__ Urea Ammonia Make and Model:

Injection Rate at Maximum Rated Capacity (Ib/br):

Operating Temperature Range (*F):

)

Slip Rate (ppm):

Minimum Gas Flow Rate at Maximum Rated Capacity (acfm):

Design Remova1 Effieiency (%):

l Selective Catalytic Reduction (SCR)

Make and Model:

Catalyst Type:

Minimum Gas Flow Rate at Maximum Rated Capacity (acfm):

Pressure Drop (in H.0):

Anmonia Injection Rate at Maximum Rated Capacity (Ib/hr):

Anano n i a Siip (ppm):

l Design Removal Efficiency (%):

EPE No:

Office Use Only 8' l) e

=g

.>e e*

0,' N ' [,,,

Page 3 of 4

PFRMIT APPLICAT16k FOR FPAC-2?A-1 (Rev. 7/92)

I.ow NOx Burner Make anti Mode 1:

Guaransce1 Nux Emi s s i o n It a t e ( i b /ht i BTU) :

i' Design it emi.

I Effi icncy (%):

~~

Particulate Trap Make and Model:

Design Removal Efficiency (%):

Fabric Filter Make and Model:

Number of Bags in Use:

Air / Cloth Ratio:

Bag Material:

Cleaning Method:

Pressure Drop (in 11:0):

Minimum Gas Flowrate at Maximum Rated Capacity (acfm):

(%)gr/dscf):

(

Design Outlet Grain Loading Design Removal Efficiency Other CFDTIFICATION:

I certify that I have examined the above information and that to the best of by knowledge it is true and complete.

(Signature subjects signer to the General Statutes provisions regarding false and misleading statemen s.)

"Y #

"Y Name (Printed):

Signed:

co ery m icer Date:

Title:

Nuclear Engineering and Support Overview TY) NOT WR1TF EFT (TV TH1 R 1iNF OFFiPF URE ONIY It has been determined that (applicable only if checked):

This source does not meet the applicability requirements of Sections 22a-174-3(a) and -29(b)(1), and therefore an application is not required.

~'

Signature Date Supervising Air Pollution Control Engineer i

Office Use Only - EPE No:

ATTACHMENT 2 t

CRITERIA POLLUTANT EMISSION CALCULATIONS l

TEMPORARY USE OF ATLAS COPCO DIESEL COMPRESSOR l

  1. PTMS900 AT MILLSTONE NUCLEAR POWER STATION UNIT 3 MAINTENANCE OF SERVICE AIR SYSTEM l

l l

l f

i 1

i