ML20148J130

From kanterella
Jump to navigation Jump to search
Finds Changes to Topical Rept B&R-002a Rev 3 Quality Assurance Prog for Nuc Pwr Plants 1977 Acceptable.Changes Should Be Incorp Into Next Major Revision That Is Submitted
ML20148J130
Person / Time
Issue date: 11/07/1978
From: Haass W
Office of Nuclear Reactor Regulation
To: Gamon T
BROWN & ROOT, INC. (SUBS. OF HALLIBURTON CO.)
Shared Package
ML20148J133 List:
References
NUDOCS 7811150138
Download: ML20148J130 (1)


Text

_

DISTRIBUTI0'l (with incoming letter):

Centrai FTle~~

DSkovholt, DPH LMFB DSE QAB Project File RES DSS SB QAB Chron. File DEisenhut, AD/0T 00R DTIE NOV 0i 1%

Dross, Jr., DPM QAB (3)

ORB #1 flSIC JSpraul, QAB ACRS (16)

ORB #2 ASLB JAilray, QAB DPM ORB #3 M4RC PDR ISEP ORB #4 I&E (6)

OLB EB SD LWR #1 PSYB ASLAP LWR #2 RSB Silanauer, ED0 LWR #3 EEB Mr. T. it. Gamon Quality Assurance Manager Brown & Root, Inc.

P.O. Box 3 Houston, Texa.

77001

Dear Mr. Gamon:

SUBJECT:

CllANGES TO B&R-002A We have reviewed your letter of October 17, 1978, cor.cerning changes to the Brown & Root (B&R) Topical Report Br.R-002A, Revision 3, " Quality Assurance Progran for Nuclear Power Plants."

September 3,1977. We agree with your assessment that the changes are nonsubstantial, and we find the changes acceptable.

Please incorporate these changes 'into the topical report when you submit the next major revision.

Sincerely, Original L.;.1ed by Walter P. Haass Walter P. Ilaass, Chief Quality Assurance Branch Division of Project Management

?81115013 l

}

.\\s\\(h/

y m,

...D.P.M. :..Q..A... P..M..:18.....

M

...J S, E, I ',,(,

_,,, @,1,,,a,y,,,,,,,,,,, [,a,,,s,,,,,,,,

,,,,,,,,,,,,,,,,l

..1.1../...... 7. 8.....

... 1 1../..../. 7. 8.....

1 1./. 7../.. 7 8.....

i

. :nc rom m o.m aux em i