ML20148H695

From kanterella
Jump to navigation Jump to search
Informs That on 970306,NRC Completed Semiannual Plant Performance Review of CPS Re Concerns W/Recent Decline in Performance.Cps Implemented Several Matl Condition Improvements & Actions to Address Performance Issues
ML20148H695
Person / Time
Site: Clinton 
Issue date: 06/03/1997
From: Caldwell J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Connell W
ILLINOIS POWER CO.
References
NUDOCS 9706110035
Download: ML20148H695 (2)


Text

.

,.__-m-

.m..

. -,...~

..<w

~:a, n

s

}'..

l

/* "'44 UNITED CTATES k

NUCLEAR REGULATORY COMMISSION

]

y N[*(v o

REGloN 111

.t E

E 801 WARRENVILLE ROAD l

/

usg. ILUNOIS 60532-4351

\\

-June 3, 1997 i

i Mr. Wilfred Connell, Vice President Clinton Power Station i

Illinois Power Company Mail Code V-275 i

P. O. Box 678 Clinton, IL 61727 l

Dear Mr. Connell:

l On March 6,1997, the NRC staff completed the semiannual Plant Performance Review l

(PPR) of the Clinton Power Station (CPS). The staff conducts these reviews for all l

operating nuclear power plants to develop an integrated understanding of safety performance. The results are used by NRC inanagement for planning and allocation of inspection resources. The PPR for CPS involved the participation of all technical divisions 2

and NRR in evaluating inspection results and safety performance information for the period of October 1996 through March 1997. PPRs provide NRC management with a current summary of licensee performance and serve as inputs to the NRC Systematic Assessment i

of Licensee Performance (SALP) and senior management meeting reviews.

l Following the last Senior Management Meeting held January 14-15,1997, you were sent a letter on January 27,1997, informing you of the NRC's concerns with the recent decline i

in performance at CPS. In our March 13,1997, letter issued after the previous PPR, we, described the formation of a Clinton oversight panel and the development of an Oversight Plan. These actions were taken to assure close NRC oversight of your actions to address performance issues. During the most recent PPR assessment period, CPS implemented several material condition improvements and actions to address plant performance issues.

l The oversight panel will continue its review of your staff's preparations for CPS restart.

4 i

Our specialist inspections scheduled for the next six months are shown on the attached inspection plan. Resident and Region-based project engineer inspections are not listed on the schedule due to their ongoing and continuous nature. In addition, we plan to evaluate j

your actions pursuant to the commitments in CAL Rill-96-013 and CAL Rill-97-OO1, and j

this may involve inspection activities in addition to those indicated.

i t

I

(

h 9706110035 970603 k

h g.

k PDR ADOCK 05000461 P

PDR

W. Connell i We plan to continue to meet with CPS management approximately every two weeks prior to the Unit restart to discuss our inspection results and progress on your performance improvement initiatives. We will inform you of any major changes to the inspection plan.

If you have any questions, please contact Geoff Wright at (630) 829-9602.

i

prely, g'.

Ja

. Caldwe(1, Dir 6r l

D' ision of Reactor Projects Docket Nos. 50-461 License Nos. NPF-62 1

Enclosure:

Inspection Plan l

cc w/ encl:

l W. D. Romberg, Assistant Vice President l

P. Yocum, Plant Manager Clinton Power Station i

R. Phares, Managar-Nuclear Assessment P. J. Telthorst, Director - Licensing Nathan Schloss, Economist Office of the Attorney General l

G. Stramback, Regulatory Licensing Services Project Manager General Electric Company Chairman, DeWitt County Board State Liaison Officer Chairman, Illinois Commerce Commission Docket File DRP OC/LFDCB PUBLIC IE-01 SRI Clinton, Dresden, RlllPRR LaSalle, Quad Cities Project Manager, NRR A. B. Beach Rill Enf. Coordinator Deputy RA DOCUMENT NAME: R:\\lN SPE CT.PLN\\CLINTO N\\2iN SPPLAN.C LI v.

.e es. 4

=,i e

i. m. m.: c om wm.m m.~

m r - em wim.n n w i v - es.

/f Rill V Rill Rijf/g OFFICE Riligy R,Ill j NAME Ring /Ga%Jile:dp KdneMSpd Leach /Kozal(VWright N

@l$ dell DATE 05/6 /97 05/ls/97 f) 05/(p/97 05/1 /97 05pt/97 OFFICIAL RECORD COPY l

l

ENCLOSURE s

CLINTON POWER STATION INSPECTION PLAN INSPECTION TITLE /

NUMBER OF PLANNED TYPE OF INSPECTION -

PROGRAM AREA INSPECTORS INSPECT!ON DATES COMMENTS i

IP 40500 Special Restart inspection - Follow-up to 4-6 TBD, Based on Restart Restart inspection and Training / Human Performance inspection Schedule Assessment (RI)

IP 83750 Radiation Protection /

2 5/19-23/97; Routine Radiation Plant Support 7/14-18/97 Protection (Cl) 10/6-10/97 IP 81700 Security / Plant Support 1

9/15-19/97 Security inspection (Cl)

IP 62706 Maintenance Rule / Maintenance 6-10 November (tentative)

Maintenance Rule inspection (RI)

IP 64704 Fire Protection Functional inspection 4-5 July - August Headquarters initiative IPs 37550 &

Corrective Actions / Quality Assurance 4-5 October / November Engineering and Quality 40500 Assurance inspections (Cl)

IP - Inspection Procedure Cl - Cora inspection - Minimum NRC Program (mandatory all plants)

RI - R gional Initiative n

~ -

- -- - -