i e
'e
'r Northem States Power Company Monticello Nuclear Generating Plant 2807 West Hw/ 75 Monticello. Minnesota 55362 9637 May 8,1997 U S Nuclear Regulatory Commission 10 CFR Part 50 Attn: Document Control Desk Section 50.90 Washington, DC 20555 MONTICELLO NUCLEAR GENERATING PLANT Docket No. 50-263 License No. DPR-22 May 8,1997 Supplement to License Amendment Request Dated November 25,1996 Safety Limit Minimum Critical Power Ratio Exhibit A of this letter provides response to question #4 as requested by the NRC regarding Monticello's License Amendment Request Dated November 25,1996 titled " Safety Limit Minimum Critical Power Ratio." This question was:
" Discuss SLMCPR determination for the Siemens fuel (8 bundles) currently in the Monticello core."
This submittal contains no new NRC commitments, nor does it modify any prior commitments.
Please contact Sam Shirey, Sr Licensing Engineer, at (612) 295-1449 if you require additional information related to this request.
//H&n' if4'
/
William J ill Plant Manager
/
Monticello Nuclear Generating Plant f'o l pi c:
Regional Administrator-Ill, NRC NRR Project Manager, NRC Resident inspector, NRC State of Minnesota Attn: Kris Sanda L.73 C dl;h
/
J Silberg
^ ^V,'
pp4 }
I *g0 f"P Attachments:
NSP Affidavit to the US Nuclear Regulatory Commission Exhibit A: May 5,1997 letter from K. V. Walters of Siemens Power l
Corporation to Kirk Schnoebelen titled, "MCPR Safety Limit for SPC QFA's in Monticello."
Exhibit B: Siemens Power Corporation Proprietary Affidavit 9706060306 970508 PDR ADOCK 05000263 l l lfllflll hhfllll smas nucmsrunauer t.ucen stu
l USNRC NORTHERN STATES POWER COMPANY May 8,1997 Page 1 l
UNITED STATES NUCLEAR REGULATORY COMMISSION NORTHERN STATES POWER COMPANY MONTICELLO NUCLEAR GENERATING PLANT DOCKET NO. 50-263 REQUEST FOR AMENDMENT TO OPERATING LICENSE DPR-22 MAY 8,1997 SUPPLEMENT TO LICENSE AMENDMENT REQUEST DATED NOVEMBER 25,1996 Northern States Power Company, a Minnesota corporation, is submitting additionalinformation to support License Amendment Request dated November 25,1996. This supplement responds to an NRC Staff question.
This letter contains restricted information as indicated by the attached Siemens Power Corporation Proprietary Notice.
NORTHERN STATES POWER COMPANY By
/dS<
l William J Hillf Plant Manager Monticello Nuclear Generating Plant 4
On this30 ay of Sw M9'? before me a notary public in and for said County, d
personally appeared Willidm J Hill, Plant Manager, Monticello Nuclear Generating Plant, and being first duly sworn acknowledged that he is authorized to execute this document on behalf of Northern States Power Company, that he k:.ows the contents thereof, and that to the best of his knowledge, information, and belief the statements made in it are true and that it is not interposed for delay.
l Samuel 1. Shirey SAMUEL 1. SHIREY l
Notary Public - Minnesota l
sooTARYPutuc. -
~~Mr Comm. Es. Jan. 31,0000 l
Sherbume County JJ ' ~ ~
~ ~ 7 ^~ ~
i l
My Commission Expires January 31,2000 i
1 9
r a
i Exhibit B i
i h
MONTICELLO NUCLEAR GENERATING PLANT i
Siemens Power Corporation Proprietary Affidavit dated May 8,1997 j
I L
f i
5 l
i l
t 9
l.
i 1
i 4
i I
e i
1 i
l l
!~
e f
l t
=
- _ _. ~.. _.. _.. - _,.. _ _
SI:m:n3 Pcw;r Ccrp:rati:n Pr:pri;tiry
~
SIEMENS D
l-
\\
i May 8,1997 KVW:97:104
+
Mr. Kirk Schnoebelen Northern States Power Comp'any 414 Nicollet Mall Minneapolis, Minnesota 55401-1927 i
l
Dear Kirk:
i j
Proprietary information Affidavit i
Enclosed is the SPC Proprietary Information Affidavit for the MCPR Safety Limit for SPC OFA's in Monticello.
i Very truly yours, I
l g
K. V. Walters i
Project Manager l
[
i I
1 l
L l
l I
l i
l l
i l
l, r
A F FlD AVIT STATE OF WASHINGTON )
) ss.
COUNTY OF BENTON
)
I, R. A. Copeland being duly sworn, hereby say and depose:
1.
I am in Product Licensing, for Siemens Power Corporation ("SPC"), and as such I am authorized to execute this Affidavit.
2.
I am familiar with SPC's detailed document control system and policies which govern the protection and control of information.
3.
I am familiar with the attachment to the letter from Mr. W. J. Hill (Northern States Power) to the Document Control Desk of the U. S. Nuclear Regulatory Commission dated May 8, 1997, entitled "May 8, 1997 supplement to License Amendment Request Dated November 25, 1996, Safety Limit Minimum Critical Power Ratio," referred to as " Document." Information contained in this Document has been classified by SPC as proprietary in accordance with the control system and policies established by SPC for the control and protection of information.
4.
The Document contains information of a proprietary and confidential nature and is of the type customarily held in confidence by SPC and not made available to the public. Based on my expwience, I am aware that other companies regard information of the kind contained in the Document as proprietary and confidential.
l l
l
i
- 5.
The Document has been made available to the U.S. Nuclear Regulatory Commission in confidence, with the request that the information contained in the Document will not be disclosed or divulged.
6.
The Document contains information which is vital to a competitive advantage of SPC and would be helpful to competitors of SPC when competing with SPC.
7.
The information contained in the Document is considered to be proprietary by SPC because it reveals certain distinguishing aspects of SPC licensing i
methodology which secure competitive advantage to SPC for fuel design optimization and marketability, and includes information utilized by SPC in its business which affords SPC an opportunity to obtain a competitive advantage over its competitors who do not or may not know or use the information contained in the Document.
8.
The disclosure of the proprietary information contained in the Document to a competitor would permit the competitor to reduce its expenditure of money and manpower and to improve its competitive position by giving it valuable insights into SPC licensing methodology and would result in substantial harm to the competitive position of i
SPC.
9.
The Document contains proprietary information which is held in confidence by SPC and is not available in public sources.
10.
In accordance with SPC's policies governing the protection and control of information, proprietary information contained in the Document has been made available, l
on a limited basis, to others outside SPC only as required and under suitable agreement l
providing for nondisclosure and limited use of the information.
l 11.
SPC policy requires that proprietary information be kept in a secured file or area and distributed on a need-to-know basis, i
i
i l
12.
Information in this Document provides insight into SPC licensing i
j methodology developed by SPC. SPC has invested significant resources in developing the l
methodology as well as the strategy for this application. Assuming a competitor had l
l available the same background data and incentives as SPC, the competitor might, at a l
1 l
minimum, develop the information for the same expenditure of manpower and money as l
l l
SPC.
l THAT the statements made hereinabove are, to the best of my knowledge, information, and belief, truthful and complete.
FURTHER AFFIANT SAYETH NOT.
SUBSCRIBED before me this Y N.
day of I
,1997.
m J
()
sc'4W
.=
0, Op.
4
]'
Q[{
4 sHnWO 4
Susan K. McCoy NOTARY PUBLIC, STATE OF WASHINGTON MY COMMISSION EXPIRES: 1/10/00 l