J Page 1 of 12 Pemit No.

OH 0001392 Application No. OH 0001392 AUTHORIZATION TO DISCHARGE UNDER THE NATIONAL POLLUTANT DISCHARCC ELIMINATION SYSTEM In compliance with the provisions of the Cletn Water.Act of 1977, NATIONAL AERONAUTICS AND SPACE ADMINISTRATION i

is authorized by the United States Environmental Protection Agency, Region V, to discharge from a f acility located at Lewis Research Center, Plum Brook Station, Sandusky, Ohio 44870 to receiving water named Kuebler Ditch (discharges 001 and 005), Ransom Bbok (dis-charges 002 and 006), Plum Brook (discharges 003,004 and 007).

in accordance with effluent limitations, monitoring recuirements and other concitions set forth in Parts 1,11, and 111 hereof.

This permit and the authorization to discharge shall expire at

midnight, Ma rch 31,1985 Permittee shall nnt discharge after the above date of expiration.

In orcer to receive autnorization to discharge beyond tne date of expiration, the per.uittee snail submit such infermation, forms, and fees, as are required by the Agency authori:ed to issue NPDES permits no later than 180 days prior to the above date of expiration.

This permit shall become effective 30 days from this date of signature. This pemit supercedes NPDES Permit Number OH 0001392 dated June 12,1975 and modified pemit dated October 13, 1978.

Signec thi.s AllG 2 5 6?D '

' rt i

/

~!" ~

pDirector,EnfortementDiv1Ticn 8011140

/j7 l

Page 2 of 12

..' )

Permit N0.0110001392~

i PART I l

A.

EFFLUEti! LIMITAT10:15 AND !!07:ITGP.ING RrQUIREMEnf5 Durin the period beginnin; on the effective date ard las t ir.g unti1 Narch 31,1985 the p raittee is euthor.' zed to discnarge frsa oatf all seria! ::::nber 001 Such discharges shall be limited end tonitcred by the permittee as specified belew:

EFFtHE:f f Cl!PACTERISTIC DISC!!A2CE i_! PIT ^i!0NS i;0.'lllGRI.':G REQUIPy'E ;TS kg/ day Other Un. ts

( eg/1) lleasurccent

  • Sarple Daily Avq Da ily Ma x Daily _Ayn Daily Max Frequency _

Tyre Flow (MGD)

Monthly Instantaneous Suspended Solids 7.58 11.37 20 30 Weekly **

24-Hr. Composite Ni trate (N) 3.79 7.58 10 20 Weekly **

24-llr. Composite Phosphorus (P) 0.38 0.57 1.0 1.5 Wee Ely *

  • 24-ilr. Compos i te Iron (Total) 0.19

. 0.38 0.5 1.0 Weekly **

24-Hr. Compos i te c

Zinc (Total) 0.15 0.23 0.4 0.6 Weekly **

24-ifr. Composi te 011 and Grease (Freon Extractables) 3.79 5.68 10

-15 Monthly 24-Hr. Composi te C00 15.16 22.74 40 60 Weekly **

24-Hr. Composite Chromium +6 0.02 0.04 0.05 0.10.

Weekly **

24-ilr. Composite-Copper (Total) 0.08 0.11 0.2 0.3 Weekly **

24-llr. Composite lead (Total) 0.02 0.04 0.05 0.10 Weekly **

24-Hr. Composi te Total Chromium 0.04 0.08 0.1 0.2 Weekly **

24-ilr. Composite Weight limitations are baded upon a design flow of 0.10 mgd.

See Part III, Paragraph 2.

Monitoring is required only when the Space Power facility (SPF) is in operation.

If the SPF is not operating the Discharge Ibnitoring Reports must indicate that the facility is inactive

. the reporting period.

and no discharge occurred d'uring The p!! shall n,t be less than 6.5 nor greater than 9,0 cnd shall be monitored on a monthly grab sample.

There shall be no discharge of floating solids or visible' foam in other than trace amounts.

Sunales taken in coupliance with the monitor {ng requirements specified above shall be tel:en at the fallu ine location:

At a point rtpresent.3tive of toe disch;rge but prior to mi xi'na wit'h the waters in

~

Kuebler Ditch at 41" 21'01" Latitude and 82" 38'39" Longitude.

e e

Page 3 of 12 -

2-Permit f;o. 011 0001392 PART I A.

EFFLt!EifT LIMITATI07;S At;D M0;ilTORit;G REQUIRDtEt!T5 l

Curi.ng the period beginning on the effective date the termittee is authorized to discharge from outfall serial n and lasting until March 31, 1985, umber 002.

Such discharges shall be limited and monitored by the permittee as EFFLL'ENT CHMACTEP.ISTIC specified below:

DISCHARGE LIMITT.T!O'2S kg/ day Other units

( mg/l)

MONITORI% REQUIR9*.E:;TS Daily Avq Oaily Max Daily Ava Da ily t'a x

_frecuency Heasurement*

Savple Flow (MGD)

Type Iron Nitra te' (N) 0.04 0.08 0.5 1.0 Monthly Ins tan taneous 0.76 1.52 10 20 Phosphorus (p)

Weekly **

24-ilr. Composite-Oil and Grease 0.08 0.11 1.0 1.5 Week ly *

  • 24-Hr. Composite 0.76 1.14 10 15 24-ilr. Composite

. Suspended Sol'ds Weekly **

1.52 2.27 20 Monthly 24-ilr. Composite Zin- (Total)

C0D 0.03 0.05 0.4 0.6 30 Weekly **

24-Hr. Compos i te 3.03 4.55 40 60 Copper (4To tal)

Weekly **

24-Hr. Composite Chromium 6 0.015 0.02 0.2 0.3 Month 1y**

24-llr. Composite Lead (Total) 0.004 0.008 0.05 0.10 Weekly **

24-lir. Composite Weekly **

24-Hr. Composite 0.004 0.008 Total Chromium 0.05 0.10 Weekly **

24-Hr. Composite 0.008 0.015 0.1 0.2 Weight li Weekly **

24-Hr. Composi te atgons are bgsed upon a design flow of 0.02 mgd.

O See Part,

a ragraph Monitoring is required only when the Hypersonic Tunnel Facility (HT facilties are inactive and no discharge occurred during the rep eports must indicate that the ortihg period.

The pfl shall not be less than 6.5 nor greater than 9 0 cod shall be monitored on a nonthly grab sample.

The e shall be no discharge of floating solids or visible fo'am in other tha n trace amounts.

Samples taken in compliance with the monitoring requirer.er.ts specified above sh ll b following location:

At a poir.t rep. esentative of the dischar.Jc, but prior to mixing with the in Ransom Brook a t 41 a

e taken at the 23'43" Latitude and 82 41'10" Longi tude.

waters

~

Page 4 of 12

~

=.

Permit No. Oil 0001392 PART I Ae EFFLUEllT Lil1ITAT10?t5 All3 !!0filiORIt:G REQUIREB1[f:TS

~

During the period beginning on the effective date and lasting until March 31, 1985, the permittee is authorized to discharge from outfall serial number 003.

Sbch discharges shall be limited and monitored by the permittee as specified below:

EFFLUENT! HARACTEolsilC DISCHARGE LI:tITAi!0:15 M0!ilTORit:S REC'JIREME ;T3 C

~

kgiday Other Units (mg/l)

~

Heasurement*

Sarple Da ily Avg Daily Max Daily Avg _

Daily Max Frequency Type Flow (MGD)

Monthly Continuous Chrom 16m+b 0.35 0.71 0.05 0.10.

Weekly **

24-ilr. Comosite Iron (Total) 3.54 7.09 0.5 1.0 Weekly **

24-Hr. Composi te lead (Total) 0.35 0.71 0.05 0.10 Weekly,**

24-Hr. Composite Mitrate (N) 70.89 141.78 10 20 Weekly **

24-Hr. Compos t te 011 and Grease (Freon Extractables) 70.89. 106.34 10 15 Monthly 24-Hr. Composite-Phosphorus (P) 7.089 10.63 1.0 1.5 leekly**

24-Hr. Composi te

~

141.78 212.67 20 30 Weekly **

24-Itr. Composite Suspended Solids

~

283.56 425.34 40 60 Monthly **

24-Ilr. Composi te C00 Copper 1.42 2.13 n.2 0.3 Weekly *4 24-Hr. Composite Dissolved Solids 5316 7089 750 100.0 Weekly **

24-Itr. Composite Total Chromium 0.71 1.42 0.1 0.2-Wee kly *

  • 24-Hr. Compos i te Weight limitations are based upon a design flow of 1.87 mgd.

4 See Part III. Paragraph 2 Monitoring is required only when the B-2 environmental chamber and the Plum Brook Nuclear Test Reactor or other CO facilities are in operation.

If these facilities are not coerating, the Discharge Monitoring Reports must indicate that the facilities are inactive and no occurred during the reporting period.

The p:1 shall not be less than 6.5 nor greater than 9.0 and shall be monitored on a monthly grab sarple.

lhere shall be no discharge of floating solids or visible foam in other than trace amounts.

Samples taken in compliance w!th the monitoring requiremer.ts specified above shall be taken at the At a noint representative of the di, charge but prior to mixing with the waters in (0110wina location:

Plum Brook at 41 23'11" Latitude and 82 39'59'" Longitude.

W i-m,e,.

w--

w.m e-y-,

S

-=

y+

e m.

u

I s

t Pag.e 5 of 12 j- -

~

' Permi t flo. 011 0001392 PART I -

A.

EfflUEtif LIMITAT10ti5 ATID N0ftITORiflG REQUIRE!!Lt{IS e

+

During the period beginning on the effective date and lasting until. March 31, 1985, the permittee is authorized to discharge from outfall serial number 004 (Sanitary Treatreent Plant).

Such discharges shall be limited and monitored by the permittee as specified below:

EFFLUENT CilARACTERISTIC DISCilARGE LIMITATI0ftS M0tilTORl!G REQUIREMEtlTS kg/ day Other Units

( mg/l )

Heasurement Sample 30-Day Avq 7-Day Avo 30-Da'v Avo.

7-D'ay Avg frequency Type,

Flow (MGD)

Weekly Ins tan taneous B00-5 Day 4.17 6.26 10 15 Weekly 24-ilr. Composi te l

Suspended Solids 4.17 6.26 10 15 Weekly 24-ilr. Corrpos i te ^

Fecal Collform Bacteria (Counts) -

1000 2000 Weekly Grab 100 ml Dissolveo Oxygen (Minimum Value) -

5.0 Weekly Grab

. Residual Chlorine 0.5 Weekly Grab Ammonia (fi)

Summer (May '1' thru October 31) 2.4 (daily maxirnum)

Weekly Grab Winter (flovertber. I thru April 30) 6.8 (daily maxir,num)

Weekly Grab Weight Ilmitations are based upon a ' design flow of 0.11 ngd.

' ~

i e The pil shall not be less than 6.5 nor greater than 9.0 and shall be monitored 'on a weekly grab sartple.

There shall be no discharge of floating solids or visible foam in other than trace amounts.

Samples taken in compilance with the monitoring requirements specified above shall be taken at the following location: At a point representative of the discharge but prior to mixing with the waters in Plum Brook.

+

+, -

e.,

...=v-

.etr~

www-,-,o-.yee-e,

-w t-se..-w w=

w,w-%

.m

,,r.

we ow r - -,

%..-,r.---emw,-

ew..

+e.-%.-new,-i,

, w w.-

4ew+y-e ee, es

-www-r-s--e w

ws-,.ew e4 c-er

---e-we+=e,

.-e,--e.

. -. wn

3.

Page 6 of 12 Pernit flo. Oli 0001392 i'

~

\\

PART I -

A.

EFFLUEtiT.Lill!IAT10 tis AfiD N0!ilTORitiG REQUIRtMEllis Durli(g the period beginning on the ef fective date and lasting until March 31, 1985, the permittee is authorized to discharge from outfall serial number 005 (Space Power Facility SPF).

Such discharges shall be limited and monitored by the permittee as specified below:

EFFLUEllT CilARACTERISTIC DISCl!ARGE LIMITATIDtiS M0filTORitiG REQUIREMENTS kg/ day 0ther Units

( mg/l )

Heasurement sample 30-Day Avq 7-Day Ava 30-Da'y Avg.

7 Day Ayq Frequency Type Flow-(MGD)

_ ~ ~

Weekly

  • Instantanecus 800-5 Day 0.57 0.85 10 15

' Weekly

  • Grab Suspended Solids 0.57 0.85 10 IS~

Weekly

  • Grab i000 2000 Weekly
  • Grab Fecal Colidonn Bacteria (Counts) -

lDO ml 0.5 Weekly

  • Monitoring is required only when there is a discharge.

If there is no discharge, the Discharge Monitoring Reports shall indicate zero flow.

Weight limitations are based upon a design flow of 0.015 mgd.

. The pil shall not be less than 6.5 nor greater than 9.0 and shall be monitored. o~n a weekly

O There shall be no discharge of floating sollds or visible foam in other than trace amounts.

Samples taken in compliance with the monitoring requirements specified above shall be taken at the following location: At a point representative of the discharge of the Package Treatment Plant prior to mixing with the waters in the drainage system flewing to Kuebler Ditch.

a-m

..--e 4.

-. ~..,..-... ---

m

.~~.....,........-.,.--.4

-.--.-....cm...

,,.c.~

.,-..m.,.

. -........ - -,.. ~,

Page 7 of 12

.~..-

~

' Pennit flo. o!! 0001392 PART I -

A.

EffLUErlT I,lHIIAT10 tis Arlo MorillonittG REqulREMErlTS Durtrig the period beginning on the effective date and lasting until March 31, 1985, the permittee is authorized to discharge from outfall serial number 006 (J Site Package Sanitary Plant).

Such discharges shall be limited and n:onitored by the permittee as specified below:

EFFLUEllT CIIARACTERISTIC D.,utARGE I. If11 T AT I0t15 M0tlITORitiG REQUIREMEtiTS kg/ day 6ther Units

( mg/l )

Heas urement Sample 30 Day Avg 7-Day Avo 30Dai,Avn.

7-Day Avq frequency Type Flow (MGD)

BOD-5 Day 0.06 0.09 10 15 _

Monthly Instantaneous Monthly Grab Suspended Solids 0.06 0.09 10 15 Monthly Grab Fecal Colldorm Dacteria (Coun ts ) -

1000 2000 Monthly Grab 100 ml Residual Chlorine 0.5 Monthly Grab Weight limitations are based upon a design flow of 0.0015 mgd.

. The pil shall not be less than 6.5 nor greater than9.0 and shall be monitored on a n:onthly grab sample.

There shall be no discharge of floating solids or visible foam in other than trace amounts.

Samples taken in compliance with the monitoring requirements specified above shall be taken at the following location: At a point representative of the discharge of the J. Site Package Sanitary Plant and prior

~

to mixing with the waters in the drainace system rinwinn to Ransom nrnnk

~

- " ' ~ -

"'4"--"

Page 8 of 12

~

Permit flo. 011 0001392 PART I A.

EffLUErli L/ft! TAT 10tl5 AtlD MotilTORiflG REQUIREliEllIS During the period beginning on the effective date and lasting until March 31, 1985, the permittee is authorized to discharge from outfall serial number 007 (B-2 Site Package Sanitary Plant).

Such discharges shall be limited and monitored by the permittee as specified below:

EFFLUEflT CilARACTERIST1C DISCllARGE LIf4II AI10 tis

' M0tilTORIitG REQUIREMEtiTS kg/ day 6ther Units

( mg/l )

Heasurenent Sample 30 Day Avq 7 Day Avg 30 D[v Avg.

7 0'ay Avq Freouency Type Monthly

  • Instantaneous Flow-(MGD) 800-5 Day 0.06 0.09 10 15 Monthly
  • Grab Suspended Solids 0.06 0.09 10 15 Monthly
  • Grab 1000 2000 Monthly
  • Grab Fecal Collform Bacteria (Counts) 100 ml 0.5 Monthly
  • Monitoring is required only when there is a discharge.

If there is no discharge, the Discharge Monitoring Report shall indicate zero flow.

Weight limitations are based upon a design flow of 0.0015 mgd.

. The pil shall not he less than 6.5 nor greater than 9.0 and shall be monitored on a monthly

There shall be no discharge of floating sollds or visibic foam in other than trace amounts.

Samples taken in compliance with the monitoring requirements specified above shall be taken at the following location: At a point representative of the discharge of the B-2 Site Package Sanitary Plant prior to mixing wi th the waters in the drainage system flowing to Plum Brook,

^

s-

.. _. - - ~ -.,

a e - gs A,.

.w.

page 9

of 12 permit no. OH 0001392 PART !

N0h!TORING AND RIPORTING 1.

Repreter.tative Saerltnt Samples and seasurements taken as required herein shall be representative of the voi6me ano nature of the monitored discharge.

1.

Reaortint

  • The permittee shall record monitornng results on Discharge Monttoring Report forms, using one such (ora for each dtscharge each month. The completed monthly forts shall be retained by peratttee for a period of three sonths beginning with each calendar quarter, and the forms f rom those three sonthe shall be sailed to U$1PA no later than the 18th dav of the following month; 1.e.

(a) Janua ry, F e b rua ry,

j Harch (subsit April 18); (b) April, May, June (subett July 18); (c) July. August, September (subatt j

October 14)1 October, November, December (submit January 28).

The permittee shall retain a copv of all reports submitted. All reports shall be submitted tot U. 5. Environ

  • mental Protection Agency Attentiont Chtef, Compliance Unit l

210 South Dearborn Street Chicago, Illinois 60604 The permittee shall submit these monitoring reports tc tt,e state for infonration only, Ohio Environnental Protection Agency Attention:

Permits and Approval Section i

361 E. Broad St., P.0If, Box 1049, Columbus!mitteeOhio 43216 s

3.

NoncoralLance Nottf! cation -

for any reason, the pe does not corply with or wi!! be unable to conpir witn any dati, eazimum ef fluent itsttation specified in this permit, the permittee shall provide the Regional Administrator and the $ tate with the following information, in writing, within five (5) davs of becoming aware of such condition: (4) a description of the discharge; (b) cause of nonconpliance; (c) the period of noncomp!!ance. including exact dates and times;'(d) if not corrected, the anttcipated time the noncompliance is expected to continue, and (e) steps being taken to reduce, eliminate and prevent recurrence of the noncomplying discharge, 4

Definitions a.

" Daily Average" Discharge 1.

aestit nas s. The "J.nly avera;e" discharge means the total discharge by weight during a cala endar month Jivided bv the number of days in the month that the production or concercial facility was operating. *here less than daily sanpling ts required by this perr.it. the daily average dis.

charge shall be determined bv the summatton of the measured daily discharges by weight divided by

=

the nuampe nr dave durine the calendar month when the measurements were made.

1.

Concent rat ten 3 atis The " daily average" concentration means the arithmette average (weighted by f;c. va;ue, og all the daily deteretnations of concentration made during a calendar =ont?.

Daily determination of concentration made using a co=postte sample shall be the concentration et the composite sample, ahen grab samples are used, the daily deterr.ination of concentration shall be the arithmetic average (weighted by flow value) of all the samples collected duttng the calendat

day, b.

" Daily Maximum" Discharge 1.

neitit Easta The " daily maximum" discharge means the mastnum total discharge by weight p e rm i t t e d during any calendar day.

1 Cencentration las t s. The "Jaily maxicum" concentration means tt.e maximum value in terms of concentration perzatted in the discharge durang any calendar day.

3.

Test Proceoures Test procedures for the analysts of pollutants shall conf orn to regulations published pursuant to section 104(g) of the Act, under which such procedures may be required.

6.

Recordtat of Results for each measurement or saeple taken pursuant to the recuirements of this permit the per:sitee snalF record the following information: (a) the esact place, date, and time of sampling; (b) the dates the analyses were performed: (c) the person (s) who performed the analyses; (d) the analytacal techniques of methods used; and (e) the results of all requiced analyses.

7.

Adcittonal wenitoring bv Permittee If the permittee monitors any pollutant at the location (s) d e s i g r.s t e d herein more frequentir than reqwared bv this perett, ustog approved analytacal cethods as specified aoose.

the results of such monitoring shall be included an the calculation.nd reporting of the values recuared in the Dascharge Monitoring Report Fore (LPA No. 33:0 1).

Such increased frequency shall also be indicated.

4.

Records Retentien All records and infor atson resulting from the monitoring activities required by thia all records permat anc;using of analyses performed and calibration and maintenance of instrumentation and recordings f rom continuous monitoring instrumentation sha!! be retained for a etnisue of three (3) years, or longer if requested by the Regional Admanistrator or the State mater Pollution Control Agency.

HANACIET R.IQUIRDDTS

~

1.

Cha'ee in Discharre All discharges authort:ed herein shall be consistent n

with the terms and condittens og inas permat, Ine dischstge of any pollutant tJentified in thts permit more frequently than or at a 1evel in eacess of that authorased shall' constitute a violation of the perant.

faci 1[ty expansions, production increases. or process modifications which will resultAny antacapated to new, different.

or increased discharges of pollutants must be reported by submission of a new NpD15 applacation tr If such changes will not violate the effluent Itaitatsons specified in this pe rmit, by notice to the p e rmi t issuing authority of such chaotes. Following sud notice. the permit may be modified to specif y mad ILaat say pollutaata met preciously lialted.

n,

.,-----e.

arm.

m v -,,,,.., -

2 Page 10 of 12 Permi t No.

OH 0001392 i

2.

Facilities Oeeration The permittee shall at all times maintain in good working order and operate as es s ic aently as possible all treatment or control facilities or systems installed or used by the i

permittee to achieve compliance with the terms and condittens of this permit.

+

3.

Adverse :rraet The termittee shall take all reasonable steps to minimi:e any adverse trpact to nasagacie waters resulting from noncompliance with any effluent limitations specifted in this permat. Including such accelerated or. additional monatoring as necessary to deteranne the nature and impact of the noncomplying discharge.

Any diversion from or bypass of facilities necessary to maintain compliance with the 4

Bvrastint terms ans conditions of thts permit as prohnbated, except (i) where unavoidable to prevent loss of isfe or severe property damage, or (11) wnere excessive storm drainage or runof f would damage any I

facilities necessary for compliance with the effluent limitations and prohibitions of this perunt, The permtttee shall promptly notify the Regional Administrator and the State in writing of each such diversion or bypass.

5.

Reaeved Substances Solids, sludges, filter Backwash, or other pollutants removed from or resulting tron treatment or control of wastewaters shall be disposed of an a manner such as to prevent any

)

pollutant from such materials from entering navigable waters.

84 Power Faltures th etder to maintain toepliance bith the effluent limitations and prohibitions of i

tnis permit, the permittee shall either! (a) in accordance with the Schedule of Compliance con-tanned in.Part 1 provide an alternative power source sufficient to operate the wastewater cont. i facilities; or, if no date implementation appears in Part ! (b) halt. reduce or otherwise contros production and/or all discharges upon the reduction. loss, or failure of one or more of the primary sources of power to the wastewater control facilities.

L 5.

RESPON5!8it!?MS i

),

stat o' f atey the oemittee shall allew the 8ectonal adataistrator or nis sutnerited recrestatatives, ppm creseatation of cre:eatials: (a) to eater con tae :e -ittee's a*emises waere an ef % eat socce is located or in wntch sey recoros are aeoered to be keot uncer the te-s sad conoit ons or tnis oeest; and (t) at reascasble times to nave access to and cooy any reCo*ds 'ecuired to be he9 unde

  • t*e te*s tad condit'ons of Inis aemit; to insDect any monitoring ecuipment or moattoring aeteod reovired in tnis r* emit; ano to saanle arv af senaree of cellutants.
2.. Transfer of o f rsPis er Centrol In the event of any changes in centrol or ownership 6f facilities l

from wnica inc wtr.ori:ew cascharges enanate, the permittee shall notify the succeeding owner or controller of ne existence of this permit by letter. a copy of which shall be f orwarded to the r

Regional Admirc.strator and the State mater Pollution Control Agency.

3.

Ava!:sdilitv of terart s - Except for data deter:tned to be cenfidential.under Section lot of the

[

Ae:, a;; repor:s prepared in accordance with the te rms of this permit shall be available for p;o;2c snspection at the offices of tne State sater Pollution Control Agen y and the Regtenal A:r:ntstrator. As required by the Act, effl.ent data shall not be constdered confidential.

i knowingly making any false state ent on any such report may result in the imposition of criminal penalties as provided for in Section 309 of the Act.

After notice and opportunity for a hearing, this permit may be modified, 4.

Per :t "ed:ficatten s u s; e:..e d, or revcaed in whole or in part during its term f or cause inclucing, but not 11=ited to.

(

the following- (a) violation of any terns of conditions of this permit; (b) obtainsng tnis permit 5

bs -tsrerresentatten or failure to disclose fully all relevant facts; or (c) a change in any l

condit:on that requires either a teoporary or permanent reduction or elimination of the authorized rl discharge.

F 5.

Tox:e Po!!utants Notwithstanding Part II 3 4 above, if a toxic effluent standard or prohibition i.nc..cAng a r.s schedule of cc=pliance specified in such effluent standard of prohibataon) as sl established under Section 30?(a) of the Act for a toxic pollutant whten is present in the discharge and such standard or prohibition is =cre strangent than any limitation for such pollutant in this per :t. this permit shall be revised or modified in accordance with the rJxic effluent standard or prohibition and the permittee so notified.

i 6.

Civil and Crintnal Listilitv - Except as provided in permit conditions on "3rpassing" (Part !!.

[

A.4) anc rower ranlare~ giart II. A-6). nothing in this permit shall be construed to relieve i

the pe rmittee from cay 11 or criminal penalties for nonccepliance.

7.

Ot; snd Hatardous Substance Lisbility - Nothint in this permit shall be construed to preclude the anst.t.: ion of any legai action or relieve the permittee from any responsibilities. liabilities, i

of penalties to which the permattee is,or may be subject under Section 311 of the Act.

l

?

g.

State Law Nothing in this permit shall be construed to preclude the institution of anv legal action or relieve the per ittee from any responsibilities, liabilities. or penalties established pursuant to any applicable State law or regulation under authority preserved by Section 510 of

[

the Act.

p 9.

Procerty althts The issuance of this permit does not convev any property rights in either real or personal property, of any exclussve privileges, nor does it authorite any injury to prsvate i

property or any invasion of personal rights, nor any infringement of Federal, state or local j

laws or regulations.

l The provisions of this permit are severable, and if any provision of this permit.

[

10.

severabt!ity or tne appiscation of any provision of thas perna t to any circums tance. is held Lavalid, th e applicatnon of such provision to other circumstances, and the remainder of this pe rmit. shall l

set be affected LAereby.

i e

~

'. i.-

Page 11 of 12 Permit No. OH 0001392 PAR 1 III OTHER REQUIREMENTS i

1.

All radioactive effluents must como.lv with the.acolicable Federal standards as specified in Section 4(a)(6) of Executive Order 11752 and Section 4(f) of Circualr No. A-106(12-31-74). The annual repore showing the radioactive levels in the discharges shou?d be forwarded to the Permit Branch, U.S. EPA by Decerber 31, 1980. A copy should also be sent to the Ohio Environmental Protection Agency for their information.

2.

When the applicant has established compliance with the discharge limitations, he may apply to the Regional Administrator for possible modi-fication of the monitoring frequency for one or more parameters.

~

3.

There shall be no discharge of polychlorinated biphenyls such as is comonly found in transformer fluids.

L DISCHARGE DESCRIPTION Discharce 001 - to _Xuebler Ditch The principle sources are: Space PNer Facility (SPF)

(1) 8000 gpm blowdown from air conditioning cooling tower.

(2) Backwash frcm a mixed bed demineralizer 2 or 3 tines per year.

i (3) Discharge from subsurface sumps, i

Discharce 002 - to Ranson Brook i

The discharges are from Hypersonic Tunnel Facility and consist of:

(1) Demineralizer backwash 4 or 5 tires per year.

(!

(2) 600 gpm blowdown from induced draf t cooling tower.

ij le Discharge 003 - to Plum Brook

'i

?

The main process is nuclear reactor facility for production of neutron and garma radiation. The discharge is mainly from the cooling tower which l

removes heat from the 60,000 kilowatt thermal nuclear reactor.

Discharge also occurs from the B-2 environmental chamber.

l Discharge 004 - to Plum Brook The effluent is from the sanitary treatment plant, i

D'ischarge 005 - to Kuebler Ditch via drainace system The effluent is from the Space Power Facility package sanitary plant.

t 1

PART III i

Page 12 of 12

[

Permit No. OH 0001392 i

DISCHARGE DESCRIPTION (Con't.)

i

~ Discharge 006 - to Ransom Brook via drainage system

- j f

The effluent is from J Site package sanitary plant.

l t

Discharge 007 - to Plum Brook via drainace system i

The effluent is frem 8-2 Site package sanitary plant.

f l

E e

i l

t

-i I

s I

i

- 1 i

]

1 i

l i

I

,. = _ ~ ~ _ _

~ % --

.' l

.4.

.'e

[

t ATTACHMENT TO LETTER OF_

6 85 1980 As a condition for State certification, the following changes were made to the permit:

1.

The daily average and daily maximum effluent limits for zinc were changed to 0.4 and 0.6 mg/l respectively.

t

2. 'The daily average and daily maximum effluent limits for copper i

were changed to 0.2 and 0.3 mg/l respectively.

i 5

3.

The daily average and daily maxjmum effluent limits for total t'

chromium were changed to 0.1 and 0.2 mg/l respectively.

i 4.

Mass limitations were included in the permit.

5.

Flow limitations were deleted from the permit.

1 l

t

6.. The 30 and 7 day averages 'for fecal coliform were changed to 1,000 and 2,000 counts /100 mi respectively.

t t

7.

The monitoring requireccent for radioactive was deleted from the

, pe rmi t.

i e

t b

8 h

W (b

9 i

1 L

i e

i i

t 71A t

i l

i l)-.

\\,

I\\

1 e/

/

)

\\

x e

\\

t r-

\\

'fl

{

\\

,/

l q

g 7,s

(

l.....o,,.e

  • a i

)

{

i 6

l l,

,s S'

.i

\\

N/

\\

/

e' u.i,... /

i s'

\\

g s

\\

i 3

s N

\\

'i N'N

'\\\\

N

\\

N.S Y

  • 85 Air $omples

.. wo,., som,i.,

+

Figure 10 - Location of PBS Sampling Stations