ML20148G625

From kanterella
Jump to navigation Jump to search
Suppl to 960717 TS Change Request NPF-38-179,providing Updated Info Based on Min Required Level in Condensate Storage Pool.Attachment a Contains Original Vortexing Calculation & Attachment B Contains Revised Calculation
Date released: 06/10/2020 Download: ML20148G625


Proposed Tech Specs,Requesting Minimum Required Level in Condensate Storage Pool Be Increased from 82% to 91% to Account for Vortexing & Instrumentation Measurement Uncertainties
ML20148G663
Person / Time
Site: Waterford 
Issue date: 06/03/1997
From:
ENTERGY OPERATIONS, INC.
To:
References
Download: ML20148G663 (2)
Rev 1 to Minimum Pipe Submergence to Prevent Vortexing Calculation.
ML20148G645
Person / Time
Site: Waterford 
Issue date: 05/07/1997
From: Gilmore R
ENTERGY OPERATIONS, INC.
To:
References
Download: ML20148G645 (16)
Rev 0 to Minimum Pipe Submergence to Prevent Vortexing Calculation.
ML20148G637
Person / Time
Site: Waterford 
Issue date: 12/01/1995
From:
ENTERGY OPERATIONS, INC.
To:
References
Download: ML20148G637 (14)
Suppl to 960717 TS Change Request NPF-38-179,providing Updated Info Based on Min Required Level in Condensate Storage Pool.Attachment a Contains Original Vortexing Calculation & Attachment B Contains Revised Calculation
ML20148G622
Person / Time
Site: Waterford 
Issue date: 06/03/1997
From: Dugger C
ENTERGY OPERATIONS, INC.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML20148G622 (5)