Submits Request for Verification of Final Survey & Issuance of Order to Terminate License R-127 Per 880126 Order. Certificate of Calibration Encl
ML20148G448
Person / Time
Site: 05000538
Issue date: 03/24/1988
From: Oliphant V
MEMPHIS STATE UNIV., MEMPHIS, TN
To: Alexander Adams
Office of Nuclear Reactor Regulation
References
NUDOCS 8803290151
Download: ML20148G448 (6)


Text

l~

3 GATE g t

MEMPHIS STATE UNIVERSITY t

{

j MEMPHIS, TENNESSEE 38152 I

4 l

4.c M ODice of the Vice President Tekphone: 90ll4544991 for Planning and Public Service I

March 24, 1988 Mr. Alexander Adams, Jr.,

Project Manager Standardization and Non-Power Reactor Project Directorate Division of Reactor Projects III, IV, V and Special Projects Office of Nuclear Reactor Regulation United States Nuclear Regulatory Commission Washington, DC 20555

Dear Mr. Adams:

SUBJECT:

REQUEST FOR VERIFICATION OF FINAL SURVEY AND ISSUANCE OF ORDER TO TERMINATE LICENSE NO. R-127 (Docket No. 50-538)

In accordance with your order dated January 26,1988, we have moved the defueled components of the AGN-201 training reactor approximately one (1) foot to allow for survey readings of the reactor and all surrounding areas. All components will remain in their present locations until an order to terminate the license and remove components is received from the N.R.C..

The following radiological surveys were made:

1.

Survey of Building #113. This building houses the reactor and all related activities. (See attachment #1)

2. Survey of rooms 140, 140A, 140A1, and 140A2. These rooms make up the reactor room and control room as well as a closet containing the air conditioning unit for this area. (See attachment #2) 3.

Smearable surface contamination of AGN-201 components.

(See attachment #2-Upper right corner)

The surveys were conducted using a Ludlum, Model-19, serial no. 32881, Micro R Meter. This instrument was calibrated by Radiation Service Organization of Laurel, Maryland. (See attachment #3)

OY 8803290151 880324 ADOCK 05000538 bl!

DR p

oco An EqualOpportunity/Affirmalise AcIlon l'niwisay

Mr. Alexander Adams, Jr.

Page 2 March 24, 1988 The smearable surface contamination counting was obtained using a shielded G-M counting system consisting of a thin window GM tube (serial no. 7181), a shielded counting pig (Gamma Products Lab.-

Model G40-serial no. 557) and a Nucleus-Model 550 Scaler / Timer (serial no.8304-071). This system was calibrated by Assistant Professor Lewis O' Kelly of the Memphis State University Physics Department. The swipes were checked for alpha contamination using a Ludlum-Model 3-G.C. serial no. 5011) and a Ludlum-Model 43-5 Alpha Probe (serial no. 11115). This unit was calibrated by Ludlum Instruments on 6/5/87.

Attachment #1 shows the results of a survey of Building #113 which houses the AGN-201 and all related activities. All readings were taken approximately one (1) meter from the floor using a Ludlum-Model 19-Micro R Meter. This instrument was calibrated by RSO Inc.

on October 26, 1987. (See attached Calibration Certificate--

dttaChment #3)

Attachment #2 shows a survey of the AGN-201 facility and control room, specifically rooms 140, 140A, 140A1 and 140A2. All readings were taken approximately one (1) meter from the floor, with the exception of the three readings taken inside the AGN-201. A reading of 10 micro R/ hour was obtained by suspending the meter inside the empty shield tank. A reading of 8 micro R/ hour was obtained by placing the meter atop the second lead shielding ring after removing the top ring. A reading of 4 micro R/ hour was obtained by suspending the meter to Glory Hole level in the center of the graphite reflector ring with the Aluminum core tank remove..

The table in the upper right corner of attachment #2 shows the locations and results of swipe tests done to detect the presence of removable surface contamination on varjous AGN-201 components as well as several swipes of the facility such as floor, table, etc.

All swipes were read for Beta and Gamma contamination using a Shielded G-M Counting System consisting of a thin window GM tube (serial no. 7181), a shielded counting pig (Gamma Products Lab.-

Model G40- serial no. 557) and a Nucleus-Model 550- Scaler / Timer (serial no. 8204-071). This counting system was calibrated by Assistant Professor Lewis B. O' Kelly of the Memphis State An Equal Opp 3rtunityl Affirmathe Action Unhtrsity

Mr. Alexander Adams, Jr.

Page 3 March 24, 1988 University Physics Department.

The swipes were then read for Alpha contamination using a Ludlum-Model 3-G.C. (serial no. 5011) and a Ludlum-Model 43-5 Alpha Frobe (serial no. 11115). This unit was calibrated by Ludlum Instruments on 6/5/87. The grid lines depicted on attachment #2 have been physically marked on the floor of the reactor facility and control room to facilitate verification.

If there is any further information we may supply or assistance we may render to expedite verification of this survey and speed the issuance of an order to terminate this licence please contact Mr. Bob Riley at (901) 454-4672.

Sincerely,

,lj s

Van N. Oliphant Vice President Planning and Public Service 11 Enclosures l

l l

l t

r.

An Equal Opportunity / Affirmative Action Uniwisity

C BUILDING 113 FIRST lLOOR 0

A{ofes:

~,,,a

.,,,, ni,,,w

-,, n w FACTOR 80074 EACTOR COtJTR OOM d

i M

Ins}<an<os0 p

  1. ]

(

e 4d4 F

A"$l"'* ~ M*A*l A ~MNO$/hlO~

REACTOR

[\\g 140 A 14 0,.

$oryne b:

I'Y' g

fRM h

140A

~~

~

y 3,//y 8%

    1. //#f/j h -vun l'?,n,

,n/n,,

(8-hTORAGE 40 de o

/

STORAGE TELEPHONE l h [f-142 gt M STORAGEf EQUIPMENT p/ 40 130 A ROOM

['[p e

)

f E

136i 146 944

- yyypp, yyyf }$2

[/3 g~

1 N

p s

/ g<

, h r

138 A" -

i d===

v l

Y

- -. - - ~ ~ ~ - - -

==

- ypo

-W-1 PJEUTROrd GEtJERATOR I

ff l

o2j

?

STORAGE

' ts g.,,p g}$

147s i.

'i g.7)

. r:EuInota

~

~

[b

,[g

{

'T'~~~~~~~-~~~~'

==E 9 IP

==

y.7, l Y

$) /?LMf),wnlt h

cIb5

~

88

~'-

3,

,3 S.

u

~~,

~

X-RAY ROOrd STORAGE STORAGE

[# A m=3-145A 143 i

,mo

_. 141 139A 135 A 133

'Y7 STA TIOtt J

  1. 3

"" g g

fg; M8lf,}

@ll,S,

~

(93, f5usww////

envud'un Mi/u, A wuxif//- vub

/6 l

w/w1 ft

<a R

qr l

e Attachment #1

r DATd _J[Ly[.ht ROUTINE RADIATION SUP.VEY : AGft-201 smearable Surface Contanination 8

C 0

E g

g B$$$fM

?.?

^

La M,

'(,/$

.?",,a,__ip u,, u,g,gy, 14

,ss p

.ito

.u ca,io iy I

os

,,c,,,,

. ~^

s t.

{ b 9, vf 2

T~

~"

/3 Os'/ >rcest

/7 17

/C

/4

/4 it te jj l'/4 g a.,4;5,,n _ m.;

,, y,,

,,c,,

~3 4

Alw w S G/.m ar g7%y > geiy

/y is

-/g

,7

/.,

/7 1

ennu mas.,

C li,da AC11 {ad j6 (1,)))

> ycp,,y

'f

._Y b

had be,Us.?d 'd'

8 t'//g

> seriri l~/C

/3 I

'?. /3

/3

/4 13 I

1%e 6 ef}/i

>sem q.L 3

y

'9 detG d 46N 9 d$p1 7 sc.ein

{

h gIS' is Vio_

,3,/3

/s

/4

[!Il 9

.ste,me Gwt

,7 y,y

> fe,,,,,

(

f tu.2;a,4. /1CtJ rn,e

/oefor

> ree,ii fi I/ Mis top e rfijj

> scent h

/8'

/7

/d AC

/5'

/ S'

/ 8' Ito

~

Area P Monitor :

?.OR mr/hr

s.. u.., n,,,

g

(- l/7

-l /7

\\?

,/ 7 h.<

'" r I I

/7,

/f

/t

[^

610 j rp Portable Instrument used:

m c,n.

/fl l9 1.ud/a,. Mdel 19-ix,ero R mete,-

b 3

/ >'

/Y

/d 1

Cal biuled by 250 z;,a.so.u q;

.)

  • 2b

/4

-)&

Kccwed ggyy.ggs m ogne,,y,,3 y,

-w.

g

,,,~ m m,7 l

p

/S'

/8

/7

/9

/7

/7

/7 REl' ARKS:

d i

/7

/4 Ai if i f/7 2e,lG A/IQW-yaobjsm irticro 2 f,.

Al h, emissp eb/s,,,el A., so,nw

'1 n asms l'

5 5 a kJ/aan n!sh,)_3'M *& GdI"'"#'i p

I *'~E I.-

l.' / 0

/d

//

/f

/8

/g

/7 1 f a gwbc, $c "cd nek, p /lele,.3Cil, (?cLc. - Ill/S-h tti f

. f;

%, pa,sf.xs chlck,nlt) 1.f k *dIvm i tWlw'u sY On

l W "

&' / 6'

/7

/7

/?

M

/S

/y '4 lY l5

/Y

/f

/d Vf

./ / f g / a.,o r, w Perrormed:

j7)lY Y:si

' (time)

I rr

/S

/7

/7

/7

/7

/d

! d $.$

l !! 20 QR 20 ao ao On "L. a j

0

=-

l Attachment #2 l

pr1Ec.

P.O. Box 1526 R50 0RDDR ol553 i

Laurel MD 20707 CONTROL NUMBER l 9378 (301)953-2482 Pa N c CERTIFICATE OF CALIBRATION ISSUEDTO INSTRUMENT Customer: Radiation service Orgentzation Make: Ludlum Tyke: uR Meter Actress: 711 Gortnan Avenue City: Laurel State: f10 Ztp: 20707 Model: 19

Contact:

Greo Srnith Phone: (301)953-2482 Sertal#- 32881 DETECTORS Make Tvoe Model SerialNumber Voltace (V) Radionuclide Efficiency 1,

Inter. Scint.

2.

3 RADI ATION SERVICE ORGANIZATION certifies that on 10/2S/S7 the above described instru was calibrated with an open field 137Cs beam calibrator (662 kev) with the results tabulated below.

Scale or Ran@ Calculated (uR/h) Observed (pR/h)

ENVIRONMENTALCONDITIONS 25 5

' 5.2 Temperature:

25 'C 25 20

+20 Pressure:

751 mmHg 50 10

+11 Humidity:

46 %

50 40

+40 CIIECK SOURCE I tM l

l 250 50

+53 250 200

  • 200 500 100

+110 L< C-e4 < -

7 ak (

r 500 400

  • 400

/

5000 1000 1100 T j. (:

' r%

5000 4000 400Q

-v%. - ).

C.t, w '.. ;

j

-- ? s \\

C.

y f

p

( ry 3 loco

,g n ID 30 0

2. r,i 15 8 ii, iD

\\Cc l

n l

COMMENTS:

I

  • Eletronically pulsed 1

lo S,.

29 l

This equipment should be returned for recollbration no later than I 4/27/88 I i

Collt,rsted try: Kr/:n PerrYh Ruiewed By:

ude b Date. 10/28/87 Merylend License MD-33-021-01

//

1

$//wlo:.n.l#3 1