ML20148F569

From kanterella
Jump to navigation Jump to search
Supplemental Deficiency Rept CP-87-131 Re Steam Generator Cubicle Steel Platform Framing & Pressurizer Support Slab. Initially Reported on 880205.Completion of Unit 1 Corrective Actions Rescheduled for 881001
ML20148F569
Person / Time
Site: Comanche Peak  
Issue date: 03/21/1988
From: Counsil W
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
CP-87-131, TXX-88331, NUDOCS 8803280219
Download: ML20148F569 (1)


Text

_

o - ?:a '

N FE Log # TXX-88331 File # 10110

=

r 903.8

.a nlELECTRIC March 21, 1988 w n.. c. counsa Enerweve hce Pressdent U. S. Nuclear Regulatory Connission Attn: Document Control Desk Washington, D.C.

20555

SUBJECT:

COMANCllE PEAK STEAM ELECTRIC STATION DOCKET NOS. 50-445 AND 50-446 DEFICIENCIES IN STEAM GENERATOR CUBICLE STEEL PLATFORM FRAMING AND PRESSURIZER SUPPORT SLAB SDAR:

CP-87-131 (SUPPLEMENTAL REPORT)

Gentlemen:

On' February 5, 1988, we notified you by our letter logged TXX-88177 of a deficiency involving unacceptable subcompartment pressurization effects resulting from a postulated pressurizer surge line break which we deemed reportable under the provisions of 10CFR50.55(e).

This report is sutmitted to update our corrective action completion schedule.

In our latest report on this issue (TXX-88177), we noted an analysis of the pressurizer surge line was being performed to eliminate the need to consider the dynamic effects associated with the postulated break.

This analysis would be in accordance with the modified General Design Criterion (GOC) 4, using leak-before-break methodology.

The completion of the corrective actions for Unit I has been rescheduled for completion by October 1,1988.

The analysis for Unit 2 will be completed prior to Unit 2 Het Functional Test.

Very truly yours, M

W. G. Counsil HAM /grr c-Mr. R. D. Martin, Region IV Resident inspectors, CPSES (3) 8803280219 880321 1 Q PDR ADOCK 05000445 g

DCD 400 hrth Ohw Street LB81 Dallas. Texas 73.'01

.........