SEQUOYAH FUELS CORPORAil0N
' ' " ~ ~ " " " * * " " " * " "
RETURN TN 39bSS November 19,1987 n.
CERTIFIED MAIL s3D RETURN RECEIPT RD2UESTED C3 Mr. Charles E. MacDonald, Chief n
Transportation Branch Division of Safeguards and Transportation, NMSS U. S. Nuclear Regulatory Conunission Washington, D.C. 20555 Re: Certificate No. 9100; Docket No. 71-9100 Request for Certificate of Conpliance Renewal
Dear Mr. MacDonald:
he certificate of Conpliance for Radioactive Materials Packages, Certificate No. 9100 was issued by the NRC to Kerr-McGee Nuclear Corporation on Septenber 26, 1983. The certificate expires May 31, 1988 (copy enclosed).
Sequoyah Puels Corporation, formerly Kerr-McGee Nuclear Corporation, is currently preparing an order for a number of slurry transport packages conforming to the certificate of Compliance, Section 5(a)(2) requirements.
In this regard SPC requests early renewal of the Certificate of Ccapliance so that it may be attached to the purchase requisition for these tanks. Your timely review at this time is greatly appreciated.
As part of the renewal SFC requests that tt[e follosing changes be made to the Certificate of Conpliance:
q 2
(
- 1) Section 3.a.
i h is section should be revised to read:
gg'*
Sequoyah Puels Corporation 3
jEg yb Kerr-McGee Center Oklahcma City, Oklahce.a 73125
/ 0,[
A O"4g
- 2) Section 5, paragraph 6 7//bt/f/
he first sentence of this paragraph should be revised to read g
"Prior to each shipment, an inspection of the tank and support
\\
DM frame shall be conducted in accordance with Addendum A, attached l
- o the renewal application dated Sevefcer, 1987."
l 6
NOV2 91987 ) T l
b, vi sscy
/,\\ C3:w a m 8801260234 871119
' 8"8 8 0 " * """ "" #"'* **
,q C
/ I;y^.y ppg 3 726
J Rs y m e D J, 5 5R/
7 Pag) 2 Should you have any questions concerning this renewal application, please contact me at (405) 270-2623 at your earliest convenience.
Sincerely, C -J f,~u t -
John C. Stauter, Director Nuclear Licensing and Regulation JCS:at Attachments 4
Yu.
CERTIFICATE OF COMPT. LANCE
C' a "
FOR AADl3 ACTIVE MATERIALS PACKAGES l
i s comun wa
. =mo. mia
<.ac u m os m cat a w a e mx mea.rs' - a.aou j 9100 4
USA /9100/A 1
3 j
~]
b,
, omta m t ta cvia.cv...... e i. cena, => = o.cuoco coawaii ene.+.o - ar s o.* m m m aw.cw. w, mao.,
.oonn e im io Coo.
I 0 F eoc.i Aegvui.oa. P n fi P.cug.ag of A.ocecin. M.i.,i.es so, f r.aaoo,i.a. f r.a. con.i.on of A ococ1=e Wei.e.el uno., Cena a Coaod.ons -
g' 8
I o in. cena.cn oo. aa,v
~ cmao, en.i cm ace.<n.a,
,.e c = r.coui.oai e m o s o. nm e tr a.oon.i.oa o, o.a.,
)I I,
am.cm.,.99 ror, eg.ac.=.acivo.ag = eo am.at on ar cou ir, in, oven o, mio -a ca in o.o.oe w w ir.asoon.o i
a I
I
- 7'SI.'fe%^.','i'".JM, ' ' "" "".*b' "' Eo'50',"cNo'.*8% #" cffE*.ato.
l I;
Kerr-McGee Nuclear Corporation Kerr-McGee Nuclear Corporation application 1;
Kerr-McGee Center dated Itarch 16, 1978, as supplemented.
I
[
Oklahoma City, OK 73125 I
I:
Il c ooce -
71-9100 I
l E. co oto s
[!
I rn cena.c=
cono. ion.i opon ion.n, in. e, nes or so era P n ti n.w.c.o=.ao a cono.cas so.ca..o e,co.
I Ij 5 l
[
(a) Packaging 1
l (1) Model No.:
KXP-20-4950 I
r l'
(2) Description J
~
I
.I l:
The container is a 4,950 gallon stainless steel cylindrical tank lll supported by a truss-type framework on a motor vehicle trailer. The I
1/4" thick tank is 82-1/2" in diameter with an overall length of 229" ll including the torispherical end bulkheads. Seven flanged, asbestos-l I
l ll gasketed access ports and a, rupture disk are provided on the top ll t;
surface. The tank is covered with an aluminum shell enclosing 3" l j h
fiberglass insulation. The tank is supported by bolsters attached to l
i I
g!
a 238-1/2" x 96" x 96" angle, channel and I-beam frame which is attached l
si to a trailer at four points. Excluding the trailer, the gross weight I
of the packaging is 55,000 pounds.
l (3) Drawings I
I g,
g!
The packaging is fabricated according to Fruehauf Corporation Drawing Il No. BKY 9010-1, Revision A.
The container chassis is described in l
I I!
Fruehauf Corporation Drawing No. B-ND4798. Revision B.
I I
l ll 1
n, l
Ij I
g, l
Ij l
I l
ti'
<l i
d l
l I!,
i I g
I,I
.1 L - - -
426
-t
-s.
c->
.i 1
N f'~..
co m m stwne w i
I Pa9e 2 Certificate No. 9100 - Revision No. 4 - Docket No. 71 9100 l
l' Y
l J
i I
.i l
5.
(b) Contents
\\
49
\\
\\
l (1) Type and fonn of material I
l l
l (1) Uranium ore concentrate in a water slurry form which meets the i
i requirements as low specific activity material.
i i
l i
i I
(ii) Solid residues in a water slurry form resulting from the chemical I
1 processing of natural uranium concentrates to produce uranium l
I compounds. The chemica sidue meets the requirements as low i
between 5 an (7)e **
Q.th aqueous solution has a pH l!
specific activi 6 ate i
(f/
i s
g i
bP
- s s !
.i g
I I
(2) Maximum quantity of naterial per package l
I t
l N:
l 42,000peups Prior to each shhent, in;4pspection of the tan -and support' frame shall be d
l 6.
p i
conducted according to thevocedures stated e Kerr-McGee Nuclear Corporation lI l
letter dated Apr0 28, 1978.. lf the i @ ti
'eals any deformation or weld
-l i
I e ice until repaired. In addition, l
i 1
cracking, the package shall tie rernoveddrdm h
a liquid penetrant test of.the entire.jppith e ring to tank weld at the l
l bolsters shall be conducted ~ ~1n accor'damnM Section V, Article 6, at least every 10,000 miles (loaded).,1fgry,
s', as defined in accordance with j\\
,l A91E,Section VIII, Division 1. Apptodl E, Paragraph UA-93(a), are detected, il I
ll I,
the packaging shall be repaired and.W pecMd prior to use:and shall be inspected prior to each shipment thereaf ter, j i 2
h Any defects shall be reported in accoNd$ce wi.th 10 CFR 971.95.
j l
u If loaded, the container shall not be' Nfed.
ll I
l I!
7.
l
.P ll il I
8.
The package authorized by this certificate shal', be transported on e Otor
[
vehicle assigned for the sole use of lynste.
The package authorized by this certificate is hereby approved for use under the ll 9.
general license provisions of 10 CFR 671.12.
't I
tf I.
ll
- 10. Expiration date: May 31,1988.
j i
1:
)
ll R,
J I.
I l
i lI
'D s
g h
0 e
9 0
427 d
exr m m e m u s eu m m e r u r m r.e x er:r.r m s m u u A
m CONDIT)ONS (cooMue#J g(
Pa'ge 3 - Certificate No. 9100 - Revision No. 4 - Docket No.
p 71-9100 h
Ni REFERENCES I
Kerr-ticGee Nuclear Corporation Application dated March 16. 1978.
1 l
Supplenents dated: April 10 and 28, 1978; and August 3, 1983.
Ranchers Exploration and Development Corporation supplement dated October l'
19, 1978.
l l
p1 FOR THE U.S. NUCLEAR REGULATORY COMMI t
l i
BREGy n'
,b Charles E. MacDona
. Chief p
Q Transportation CertiWeation Branch I
I g
Division of Fuel CycVAd I
l SEP 2 6 % \\s Material Safety.-ftiS9' 4
Q (p t '
fl p-g Da te; ar a
sw z u w.
m v
'l l.ff,,p s,n.e % g
~
l
\\
(). * '
D
~
!,L&* g.. '
g
'.s..
l'.
jjl 0)
"*f. CA
~
l "0.x
' yNT
,f l.
?
1l v',
e 0#f/
l
'4
+O s
O i,
Y k***
l i
pI I
I I,
l I
l l
i
,1 i
f i
I 1
1, il~
i I
l
]
c I L I,
}I' l!
I l'
I I
I 428 l
..................................._.......at
Addendum A Certificate of Compliance for Radioactive Materials Packages Certificate No. 9100 Docket No. 71-9100 Prior to each
- shipment, the tank and support frame shall be inspected as noted below.*
- a. Area for Inspection Each of the ten welded truss joints per side of the cargo tank frame and the interior for each of the six main support bolsters where they are attached to the vertical strength rings onto the vessel wall (four inspection ports per side
- eight total) will be inspected.
b.
Frequency The complete inspection delineated above will be conducted prior to each shipment of the ore concentrate slurry on public highway.
- c. Inspectors The OA inspector will personally conduct each required inapection.
- d. Recordkeeping The
- attached, detailed inspection
- form, will be followed for each inspection and kept on file for future reference.
- Reference Kerr-McGee Nuclear Corporation letter dated April 28, 1978 noted in Certificate of Compliance dated September 26, 1983, Section 5, paragraph 6.
~
s V
~ be carofully inspected prior to cach highway shipt:ent.
NOTE Tankor nuot D
P I
A, F -
3 t
\\
g r
\\
i 1
h\\
REAR FRohlT l
\\
)
\\\\'
f
' H J
6 Q
Ci A E G
-3.;..,_-
, - _a 5,
- >w, : s,-___-_,.
w
- s..,
45 [5-6
[1-E[2-5 BOLSTER NSPECTION
'. PORTS Inspection concents (OK, hairline crack,, slight bend, etc.):
TRUSS JOINTS Right Side Initials Left Side Initials A
B C
D E
F G
H I
J BOLSTER INSPECTION PARTS
- l 1-2 i
2-3 I
4-5 l
5-6 Use long-handled inspection mirror and light source.
- NOTE:
SU"." ARY_: (Check and sign appropria te state:ent)
All inspections indicate no sign of per=anent deformation of weld cracking, I
I Date I ns p ec to r_.-
Unusual or abnormal inspection results noted above have been reported.
I Date Inspector Name 1
c -
D3CKEl NO. ___
b
~
C0!iIiiOL H 0.
M77 DAIE OF 000.
._O If
=_.
DATE RCVD. __.2[ 8_.
[,'
FC U F._ _ __
PDR _ -
fCAF _ -
LPDR ___._.,
1I, E RFL _
S'sFEGUARDS FCTC __ V _
Oilier _
auen 7mn W y,