ML20148E575

From kanterella
Jump to navigation Jump to search
Responds to NRC 760422 Request for Addl Info Re IE Insp Rept 50-010/76-03.First Aid Supply Area Will Be Provided Near Decontamination Facility.Describes Supplemental Emergency Procedure Availability,Locations & Organization
ML20148E575
Person / Time
Site: Dresden  
Issue date: 06/07/1976
From: Bolger R
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20148E580 List:
References
NUDOCS 8010270581
Download: ML20148E575 (2)


Text

~

1

=

+.

Csmmsnwealth Edison gg J

One First Nanonal Plaza, cNeago. filinois

  1. a Address Reply to: Post Office Box 767 Chicago, filinois 60690 i,

June 7, 1976 Mr. James G. Keppler, Director Directorato of Inspection and Enforcement - Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road i

Glen Ellyn, Illinois f,013 7

Subject:

Dresden Station Unit 1 IE Inspection Repo t No. 50-10/76-03 NRC Docket No. 50-10 Reference (a) :

J. M. Allan's letter'to Byron Lee, Jr.,

dated April 22, 1976 Daar Mr. Keppler:

The following is a supplemental reply to the subject IE inspection report requested by reference (a).

Decontamination /First Aid Facilities It is important to clarify that our plans are to provide a permanent area for first aid supplies near the decontamination facility.

Until this. permanent facility is available, a standard Commonwealth Edison Company first aid kit will be maintained in the area of the present decontamination facility.

In our judgement, these provisions will meet the GSEP requirement, although they are not optimum.

Emergency Plan Implementing Procedures To clarify our intent relative to supplemental emergency procedures, it is our intent to include references only in the Emergency Plan Implementing Procedures for subjects covered by other urcaden Station Procedures.

Dresden Station Procedures are can-trolled and copies a"e maintained in numerous locations including the Control Room, the Shift Engineer's Office, the Assistant Superintendent's Office, and the Technical Staff Supervisor's Office.

Copies of these procedures are also sent to the Production

(

TlllS DOCUMENT CONTAINS

@ H270 N /

hj

.P00R QUAUTY PAGP^'

l

' ~ ~ ~ ~

'b Commonwealth Edison Mr. James 1G. Koppler June 7, 1976 4

System Analysis' Department and the NRC Region III office.

In these locations, they are readily available for reference in the event of an emergency and they are available for your review.

We agree that during an emergency, these referenced proce-dures must be available without sever:hing.

Incorporating the appropriate reference in the Supplemental Emergency Procedures ensures that the applicable procedure will be identified quickly.

The numerous locations and orbanization of these procedures ensures

- they will be quickly hnplemented after identification.

We would like to take this opportunity to comment on paragraph 7.a.2, page 11 of'the subject inspection report.

The third sentence should read "New Rad-Men receive a 10-hour first aid training course."

Please contact this office if irou hr.ve any additional questions on this matter.

Very truly yours, 8

R.

L. Bolge Assistant Vice President l

.