Summarizes File Documentation Re Elimination of Insp of shim-safety Rod Position Potentiometer Based on Success of Hardware Mod
ML20148E007
Person / Time
Site: University of Iowa
Issue date: 10/28/1978
From: Hendrickson R
IOWA STATE UNIV., AMES, IA
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20148E010 List:
References
NUDOCS 7811060073
Download: ML20148E007 (2)


Text

., 2 a

Department of Nuclear Engineering 261 Swecocy Hall IOWA STATE ^" io* 5* "

~

UNIVERSITY Telephone 515 294-5840 October 28, 1978 DOCKET No. 50-116 Director of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D.C. 20555

Dear Sir:

This report summarizes documentation on file at the UTR-10 facility which has been reviewed and approved by the Radiation Safety Committee at Iowa State University.

SUBJECT:

Elimination of Inspection of Shim-safety Rod Position Potentiometer.

Ref: Letter to A. Giambusso, dated September 27, 1973, enclosed.

An inspection of the mounting hardware which attaches the shim-safety position potentiometer to the drive mechanism has been pe.rformed at six-month intervals since September, 1973. This inspectica procedure has now been eliminated for the following reasons:

1. No evidence of malfunction or any eendency to malfunction has been found in ten inspections; the success of the hardware modification has been proven.
2. The inspection procedure itself was potentially harmful to the drive mechanism since complete removal of the drive mechanism was required.
3. Elimination of this inspection procedure is supported by the Radiation Safety Committee.

0 781?.06 007,3 0 7

  • \s

, Director of Nuclear Reactor Regulation October 17, 1978 Page 2 Yhe change in procedure does not involve a change in the Technical Specifi-cations nor does it constitute an unreviewed safety question. The change is necessary to reduce the wear and tear on a safety system unit.

Sincerely,

~

4c( -

.< C(,u 4lae,J Richard A. Hendrickson Reactor Supervisor Approved:

Y W[j]

A. F. Voigt, Chairman Radiation Safety Committee RAH:jes Enclosure cc: G. Burnet NRC/0IE/ Region III i