Text
-
v i
y
- 7 p g g g__
,9)
L MMITTIVIAB4 1256 N. CHURCH STREET RETURN TO 396-Sj MoORESTOWN, NJ 08057 NUCLEAR (609) 722-5700 Db
- /
yr e :.. p
/
d 5d rri
.' 2//x Su -
c>
4; to January 26, 1988
$^
,17 l', " q / :c?/ /
\\ ',
4 w.
l s
Mr. Charles E. MacDonald, Chief M T o\\
. pf
~ ux Transportation Certification Branch 4
h'
' ?),'?o L7 U.
S.
Nuclear Regulatory Commission M
~
Washington, DC 20555
\\M (3 \\? iaj S x >
-d
SUBJECT:
CERTIFICATION OF THE HN-215H SHIPPING PACKAGE DOCKET NO. 71-9222
'O P
Reference:
Hittman Nuclear Letter dated December 14, 1987 (Application for a Certificate of Compliance for the HN-215H Shipping Package)
Dear Mr. MacDonald:
Enclosed are eight (8) copies of the following Hittman document for your review in support of our application for a Certificate of Compliance for the HN-215H Shipping Package:
Hittman Drawing STD-02-077, Rev.
3, "HN-215H Cask Assembly" Revision 2
of the HN-215H Cask Assembly drawing was previously submitted to you for your review in the above referenced letter.
This drawing has been revised to provide additional fabrication and fastening details for the ratchet binder bolts / pins.
It has also been revised to raflect
- various, circumferential locations of the vent.
These changes to the HN--215H Cask Assembly drawing do not affect the safe operation of the package and no changes to the cask Safety Analysis Report are required.
The
$150 application fee associated with the processing of this application for a Certificate of Compliance was forwarded to you with'.
our July 13, 1987, letter.
It is noted that the attached documents are stamped "PROPRIETARY" and bear notices relative to the further dissemination of this infor-mation.
Hittman has no objection to the fil'ing of this material in the Nuclear Regulatory Commission Public Document Room, provided that the notices remain on file with this material ~.:
- EE NO REQU R D 8803240403 880126 f
.. (@. 3[f y
{DR ADOCK 0710 2
m j
' ~
fart of the Ifadiological Services Division 'of WEstingNOuss.
U#
m E
- ' ' ~ - ' ' - - - ' " ' - - ~ - ~ '
- Mr. Charles E. MacDonald, Chief January 26, 1988 Page 2 Your expeditious review of. this request for the issuance of a Certificate of Compliance for the HN-215H cask would be much appreci-
- ated, given the. similarity of this program with those already ap-proved for certificate of compliance No. 71-9176.
Very truly yours, Bryan A. Roy Manager, Design and-Process Engineering DJW/raj Enclosures As Stated cc:'D. Wozniak D. Neely K.
Salvage
-Cask File t
HITTNIAN 1256 N. CHURCH STREET I
NUCLEAR MOORESTOWN, NJ 08057 (609) 722-5700 SAFETY ANALYSIS REPORT FOR THE HN-215H RADWASTE SHIPPING CASK f
Part of thg Radiological Services Division:'of' Westinghouse
'['
l ATTACHMENT
,73 1
Dissimilarities.between Hittman Document STD-R-02-016 and S.A.R.
associated with~ Certificate of Compliance No. 71-9176 Added~page i, "To the User".
. Describes
- document, its. intent, and primary sources of informa-tion used.
Section 1.0, General-Information Section has been rewritten for clarity and to solely reflect the HN-215H cask.
Section 2.4.3.1, Packaae Liftina Luas Actual weight of HN-215H cask used in calculations.
Margins of safety increased.
Section 2.4.3.2, Primary and Secondarv Lid Liftino Luas 1
Actual weight of HN-215H cask lid used in calculations.
Mergins of safety increased.
f-%
Section 2.4.4, Tiedowns Section has been revised to solely reflect the HN-215H cask.
All margins of safety increased.
The finite element analysis used to determine the stresses induced into the outer shell by the tie-down lugs has not been revised.
This analysis utilizes a cable tension load which is conservatively higher than those calculated l
for the HN-215H cash.
Section 2.5.1, Load Resi stance l'
Actual weight and outer shell height of HN-215H cask used in calculations.
Margin of safety increased.
Section 2.5.2, External Pressure Actual weight and dimensions of HN-215H casks used in calcula-i l
tions.
Margins of safety increased.
l Section 2.6, Normal Conditions of Transport Opening paragraph has been rewritten for clarity and to solely
[
reflect the HN-215H cask.
I Section 2.6.3, Prescure i
l [)
Actual dimension of HN-215H cask used in calculation of end plate
(_/
stress.
Margin of safety increased.
Page 1 of 2
Section 2.6.6.1, Flat End Droo
-,s e
Section has been revised to solely reflect the.HN-215H cask eval-uation.
Margins of safety previously provided in tabular form unchanged.
Section 2.6.6.2, Side Droo Section has been revised to solely reflect.the HN-215H cask eval-uati on.
Margins cf safety previously provided in tabular form unchanged.
Section 2.6.'.3, Corner Droo 6
Section has been. revised to solely reflect the HN-215H cask.
Margins of safety increased.
Section 3.0 Thermal Evaluation Section has been revised to solely reflect the HN-215H cask eval-uation.
Results for the cask remain unchanged.
Section 4.0, Containment Section has been revised to solely reference the HN-215H cask.
No other changes have been made.
Section 5.0, Shieldino Section has been revised to Tolely reference the HN-215H cask.
No other changes have been mado.
Section 6.0, Criticality Evaluation Section has been revised to solely reference the HN-215H cask.
No other changes have been made.
Section 7.0, Operation Procedures Section ~has been completely rewritten.
This section was previ-ously transmitted to the NRC as a portion of Westinghouse Docu-ment STD-D-02-OO6.
It has been revised to include the informa-tion which you requested in your letter dated September 1,
1987 (Letter SGTD: RHO, 71-9176)
Section 8.0, Acceptanc.e and Maintenance Section has bnen completely rewritten.
This section was previ-ously transmitted to the NRC as a portion of Westinghouse Docu-ment STD-D-02-OO6.
It has been revised to include the informa-tion which you requested in your letter dated September 1,
1987
[
(Letter SGTD: RHO, 71-9176) s-Page 2 of 2
.,......