4 pn ma%g UNITED STATES p
t NUCLEAR REGULATORY COMMISSION u
o
{
REGloN IV 0
4'+9 * * * * *,o['
611 RYAN PLAZA DRIVE, SUITE 400 AR LINGToN, TEXAS 760118064 REVISED REVISED REVISED REVISED REVISED REVISED REVISION TO MEETING LOCATION ISSUED ON MAY 1,1997 May 28,1997 i
NOTICE OF LICENSEE MEETING Name of Licensee:
Entergy Operations, Inc Name of Facility:
Waterford 3 Docket:
50-382 4
1 Date and Time May 29,1997 of Meeting:
10 a.m. to noon d
Location of Meeting:
Waterford 3 James M. Cain Entergy Education Center Auditorium Taft, Louisiana l
Purpose of Meeting:
Discuss licensee progresa in implementing their FOCUS Plan NRC Attendees:
E. Mershoff, Regional Administrator K. Perkins,~ Director, Walnut Creek Field Office F. Miralgia, Deputy Director, Office of Nuclear Reactor Regulation (NRR)
P. Harrell, Chief, Project Branch D, Division of Reactor Projects (DRP)
C. Patel, Project Manager, Project Directorate IV-1, NRR L. Keller, Senior Resident inspector, Project Branch D, DRP Licensee Attendees:
C. Dugger, Vice President Operations T. Leonard, General Manager Plant Operations A. Wrape, Director, Design Engineering i
F. Drummond, Director, Site Support E. Ewing, Director, Nuclear Safety D. Matheny, Operations Manager R. Azzarello, Maintenance Manager
/
D. Vinci, Systems Engineering Manager
~7 T. Gaudet, Licensing Manager NOTE:
This meeting is open to attendance by members of the general public, y
J y,\\ n Approved By:
(ru Thomas P. Gwynn,/Dir ctor Division of Reactor jects 9706020114 970528 ADOCK0500g2 PDR P
l Nlillplpl?l
Entergy Operations, Inc. E-Mail To:
FOR
(
)
NRC Attendees PMNS Mtg Announcement Coordinator JKR E. L. Jordan, DEDO PAB H. L. Thompson, DEDR ACT A. C. Thadani, ADT/NRR RPZ R. P. Zimmerman, ADP/NRR OEMAll J. Lieberman, D/OE LJC L. J. Chandler, OGC CAH C. A. Hackney, RSLO DMK1 D. M. Kunihiro, WCFO GFS G. F. Sanborn, EO BWH B. Henderson, PAO MFH2 M. Hammond, PAO JAC1, CMS, CJG RA Secretaries LAT, DLF, CAM 3 DRP Division cc:
[ DMB (IE 45)1)
OEDO RIV Coordinator (17G21)
ORA File RIV File DRP File To receive copy of document. Indicate in box: "C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy RIV:PE:DRP/D C:DRP/D l RSLO l
PAO l
D:DRP l
GEWerner;dif PHHarrell CAHackney BWHenderson TPGwynn 5/28/97 (NA)
(NA)
(NA) 5/28/97 OFFICIAL RECORD COPY