ATWS MEETING NOTICE DISTRIBUTION l
S. Hanauer P. Check R. Mattson G. Lainas F. Schroeder D. Ziemann l D. Ross A. Schwencer T. Novak Z. Rosztoczy D. Skovholt X. Kniel D. Vassallo V. Benaroya W. Gammill R. Satterfield D. Eisenhut F. Rosa B. Grimes W. Butler J.R.. Miller G. Lear J.P. Knight B.J. Youngblood R. Tedesco A. Buhl R. Vollmer E. Imbro V. Moore P. Baranowsky M. Er nst D. Crutchfield R. Denise G. Knighton T. Speis D. Bunch J. Stolz F. Cherny
- 0. Parr D. Tondi S. Varga V. Rooney R. Baer W. Minners R. Minogue (NL 5650)
L. Crocker G. Arlotto (NL 5650)
G. Mazet:s S. Levine (1130 SS)
A. Thadani L.S. Tong (1130 SS)
R. Woods L. Shotkin (1130SS)
ACRS (16) (H-1016)
Central File IE (3) (E N Towers)
NRR Rdg. File Receptionist ,Phillips Blg.
RSB Rdg. File .. . ,~ n - ,w - . - . .
(H-1016) (Lobby-),a )
( NRC PDR 781102 o469
-- o ,,
/
y' UNITE D STATES
, NUCLEAR FlEGULATORY COMMisslON
{ $ WASHING TON, D. C, 20555
- /
OCT 2 31978 MEMORANDUM FOR: T. M. Novak, Chief, Reactor Systems Branch, DSS FROM: A. C. Thadani, Reactor Systems Branch, DSS
SUBJECT:
FORTHCOMING MEETING WITH GE ON ATWS DATE: Tuesday, November 7,1978 TUT- 9:00 a.m.
LOCATION: P-130A, Phillips Bldg.
Bethesda, MD PURPOSE: (See attached list)
PARTICIPANTS: NRC: R. Mattson, V. Stello, D. Ross, T. Novak, P. Check, W. Minners, S. Hanauer, R. Woods,.R. Satterfield, M. Ernst, J. Youngblood, A. Thadani , _ et 61.
-GE: E. Fuller, H. Pfefferlen, J. Weis, et al.
l f ., .b,2 / >J*"
Asho C. Thadani Reactor Systems Branch Division of Systems Safety
Attachment:
Items of Discussion i cc: (See attsched list) 1
Contact:
Ashok Thadani, NRR l 49-27341
ATTACHMENT Items of Discussion GE has been asked to discuss the following items:
- 1. Description of plant changes considered
- 2. Reasons for differences between new analyses a..d earlier (NED0-10349) analyses
- 3. Impact of logic changes on plant safety
- 4. Role of Standby Liquid Control System Operator Pool Temperature Hi Temp Effects on Other Equipment Boron Mixing and Effectiveness
- 5. Improved S/R Valves and HPCI Data Base
- 6. Cost of this fix
- 7. Event Tree Analysis k - _ _ _ _ _