May 21, 1997 Mr. Thomas Rowland, Director i

U. S. Department of Energy Ohio Field Office West Valley Demonstration Project PO Box 191 l

West Valley, NY 14171 1

SUBJECT:

NRC TLD MONITORING AT WEST VALLEY, FIRST QUARTER,1997

Dear Mr. Rowland:

.i Enclosed is a copy of the TLD monitoring results around the subject facility for the first J

quarter of 1997. The large value noted for Station #11 is due to the proximity of this

]

dosimeter to a waste storage facility located at the site. Similar results have been noted for each monitoring period.

Sincerely, Richard K. Struckmeyer Senior Radiation Specialist j

Emergency Preparedness and l

Safeguards Branch j

Division of Reactor Safety f

a

'y.

/\\'

. d I

Docket No.

99990081 i

[

Enclosure:

As stated cc w/ encl:

I P. Piciulo, NYSERDA State of New York f

11.8185191Ellllll am 300010 9706020055 970521 REG 1 GA999 EUSDOE 99990081 PDR

/

1 T. Rowland Distribp_tirm w/ encl:

Region I Docket Room (with concurrences)

R. Struckmeyer, DRS G. C. Comfort, NMSS W. Dean, OEDO D. Screnci, PAO PUBLIC Nuclear Safety Information Center (NSIC)

DRS File a

DOCUMENT NAME: A:\\WVALLTTR.971 To recehe a copy of this decuawat,indkate is the bes: 'C' = Copy widem anachmem/enckawe 'E' = Copy with anachmem/encloswe

  • N' = No copy 0FFICE RI/DRS E RI/DRS u(MD l

NAME RStruckmeyer24/2 MModes V V

DATE 05/19/97-05#7,M97 0FFIClic RECORD COPY t

.._m

(

i-I WEST VALLEY TLD DIRECT ENVIRONMENTAL RADIATION MONITORING RESULTS Anneal date

12/11/ %

l Field placement date

01/09/97 Retrieval date
04/02/97 Readout date
04/15/97 Gross Monitoring Period 126 days (12/11/% - 04/15/97)

Field Monitoring Period 84 days (01/09/97 - 04/02/97) l l

Transit Period 42 days i

Station Distance Direction Gross Exposure Net Exposure l

Number (miles)

(degrees)

(mR /126 days)

(mR / 90 days)-

1 4.0 350 19.0 +/- 0.6 ; 2.9 15.4 +/- 0.7 ; 4.3

.2 3.6 144 19.3 +/- 0.6 ; 2.9 15.7 +/- 0.7 ; 4.3 3

1.5 92 18.9 +/- 0.6 ; 2.8 15.2 +/- 0.7 ; 4.3 i

4 1.2 51 18.1 +/- 0.5 ; 2.7 14.4 +/- 0.7 ; 4.2 5

2.1 10 18.6 +/- 0.6 ; 2.8.

14.9 +/- 0.7 ; 4.3 6

1.7 319 20.4 +/- 0.6 ; 3.1 16.8 +/- 0.8 ; 4.5 7

1.2 262 19.6 +/- 0.6 ; 2.9 15.9 +/- 0.7 ; 4.4 l

8 1.4 234 19.0 +/- 0.6 ; 2.9 15.3 +/- 0.7 ; 4.3 9

0.3 300 28.1 +/- 0.8 ; 4.2 25.0 +/- 1.0 ; 5.4 10 on-site 43 26.0 +/- 0.8 ; 3.9 22.8 +/- 0.9 ; 5.2 l

11 on-site 334 699 +/- 21 ; 105 744 +/- 23 ; 113 12 on-site 83 66.7 +/- 2.0 ;10.0 66.5 +/- 2.2 ;11.1 1

Transit Dose 4.7 +/- 0.3 ; 2.8

=

l Results are reported as Measurement +/- Random error ; Total error (Total error = Random + Systematic) 4 l

l