FORM NT.C-591 @,g, QU)(ciQfM;;j Qf . 3 m OFFICE OF INSPECTION AND ENFortCEMENT INSPECTION FINDINGS AND LICENSEE ACKNOWLEDGMENT i.uCanSEE a. usanu. o rrica  !,

l Milwaukee School of Engineering US Nuclear Regulatory Commission 1025 N. Milwaukee Street Office of Inspection & Enforcement Milwaukee, Wisconsin 53201 799 Roosevelt Road Glen Ellyn, Illinois 60137 Assist by RV

s. DOCKET MUMSER{S) 4. L.ICENSE MUM SER(S) 5. D ATE OF iMSPECTION i

SNM-997 Aug. 31, 1978

e. INSPECTION FINDiMOS The inspection was an examination of the activities conducted under your license as they relate to radiation sar ty and to compliance with the Commission's rules and regulations and the conditions of your license. The inspection consisted of selective examinations of procedures and repte.

sentative records, interviews with personnel, and obserystions by the inspector. The findings as a result of this inspection are as follows:

Cil No items of noncompliance or unsafe conditions were found.

The following items of noncompliance related to records, signs, and labels were found:

O A. Rooms or areas were not properly posted to indicate the presence of a RADI ATION AREA.10 CFR 20.203(b)or 34.42 O B, Rooms or areas were not properly posted to indicate the presence of a HIGH RADIATION AREA.

10 CFR 20.203(c)(1) or 34.42 O C. Rooms or areas were not properly posted to indicate the presence of an AIRBORNE RADIOACTIVITY AREA.

10 CFR 20.203(d) ,

I O D. Rooms or areas were not properly posted to indicate the presence of RADIOACTIVE M ATERIAL.10 CFR 20.203(c)

C E. Containers were not properly labeled te indicate the presence of RADIOACTIVE MATERIAL.

10 CFR 20.203(f)(1) or (f)(2) l O F. A current copy of 10 CFR 20, a copy of the license, or a copy of the operating procedures was not properly posted or  !

made available.10 CFR 20.206(b) l i

O G. FormNRC 3 was not properly posted.10 CFR 20.206(c)

O H. Records of the radiation exposure ofindividuals were not properly maintained.10 CFR 20.401(a) or 34.33(b) l O l. Records of surveys or disposals were not properly maintained.10 CFR 20.401(b) or 34.43(d) l, i

O L Records of receipt, transfer, disposal, export or inventory oflicensed material were not properly maintained.  !'

10 CFR 30.51,40.6I or 70.51 l:

s t.

O K. Records of leak tests were not maintained as prescribed in your license, or 10 CFR 34.25(c)  !

~

O L. Records ofinventories were not maintained.10 CFR 34.26 j C M. Utilization logs were not maintained.10 CFR 34.27 O N. Records of radiation survey instrument calibration were not maintained.10 CFR 34.24 O O. Records of teletherapy electrical interlock tests were not maintained as prescribed in your license.

O P. Other .

l f,\RC Insoector) 7' The NRC Inspector has explained and I understand the items of noncompliance listed above. The items of l I

noncompliatice will be corrected within the next 30 days.

j (Datel (Licensee Representatt~e - Title or Position)

ORIGINAL TO LICENSEE 75H@ on a v